• Title/Summary/Keyword: 방사선치료시설

Search Result 30, Processing Time 0.022 seconds

The Development of On-Line Statistics Program for Radiation Oncology (방사선종양학과 On-line 통계처리프로그램의 개발)

  • Kim Yoon-Jong;Lee Dong-Hoon;Ji Young-Hoon;Lee Dong-Han;Jo Chul-Ku;Kim Mi-Sook;Ru Sung-Rul;Hong Seung-Hong
    • Radiation Oncology Journal
    • /
    • v.19 no.4
    • /
    • pp.369-380
    • /
    • 2001
  • Purpose : By developing on-line statistics program to record the information of radiation oncology to share the information with internet. It is possible to supply basic reference data for administrative plans to improve radiation oncology. Materials and methods : The information of radiation oncology statistics had been collected by paper forms about 52 hospitals in the past. Now, we can input the data by internet web browsers. The statistics program used windows NT 4.0 operation system, Internal Information Server 4.0 (IIS4.0) as a web server and the Microsoft Access MDB. We used Structured Query Language (SQL), Visual Basic, VBScript and JAVAScript to display the statistics according to years and hospitals. Results : This program shows present conditions about man power, research, therapy machines, technics, brachytherapy, clinic statistics, radiation safety management, institution, quality assurance and radioisotopes in radiation oncology department. The database consists of 38 inputs and 6 outputs windows. Statistical output windows can be increased continuously according to user's need. Conclusion : We have developed statistics program to process all of the data in department of radiation oncology for reference information. Users easily could input the data by internet web browsers and share the information.

  • PDF

A Customized Cancer Radiation Treatment Planning Simulation (ccRTPs) System via Web and Network (웹과 네트워크 기술을 이용한 환자 맞춤식 암치료 계획 시뮬레이션 시스템)

  • Khm, O-Yeon
    • Progress in Medical Physics
    • /
    • v.17 no.3
    • /
    • pp.144-152
    • /
    • 2006
  • The telemedicine using independent client-server system via networks can provide high quality normalized services to many hospitals, specifically to local/rural area hospitals. This will eventually lead to a decreased medical cost because the centralized institute can handle big computer hardware systems and complicated software systems efficiently and economically, Customized cancer radiation treatment planning for each patient Is very useful for both a patient and a doctor because it makes possible for the most effective treatment with the least possible dose to patient. Radiation planners know that too small a dose to the tumor can result in recurrence of the cancer, while too large a dose to healthy tissue can cause complications or even death. The best solution is to build an accurate planning simulation system to provide better treatment strategies based on each patient's computerized tomography (CT) image. We are developing a web-based and a network-based customized cancer radiation therapy simulation system consisting of four Important computer codes; a CT managing code for preparing the patients target data from their CT image files, a parallel Monte Carlo high-energy beam code (PMCEPT code) for calculating doses against the target generated from the patient CT image, a parallel linear programming code for optimizing the treatment plan, and scientific data visualization code for efficient pre/post evaluation of the results. The whole softwares will run on a high performance Beowulf PC cluster of about 100-200 CPUs. Efficient management of the hardware and software systems is not an easy task for a hospital. Therefore, we integrated our system into the client-sewer system via network or web and provide high quality normalized services to many hospitals. Seamless communication with doctors is maintained via messenger function of the server-client system.

  • PDF

Frequency of Micronuclei in Lymphocytes Following Gamma and Fast-neutron Irradiations (방사선 조사량에 따른 인체 정상 림파구의 미세핵 발생빈도)

  • Kim Sung-Ho;Cho Chul-Koo;Kim Tae-Hwan;Chung In-Yong;Yoo Seong-Yul;Koh Kyoung-Hwan;Yun Hyong-Geun
    • Radiation Oncology Journal
    • /
    • v.11 no.1
    • /
    • pp.35-42
    • /
    • 1993
  • The dose response of the number of micronuclei in cytokinesis-blocked (CB) lymphocytes after in vitro irradiation with $\gamma$-rays and neutrons in the 5 dose ranges was studied for a heterogeneous population of 4 donors. One thousand binucleated cells were systematically scored for micronuclei. Measurements performed after irradiation showed a dose-dependent increase in micronuclei (MN) frequency in each of the donors studied. The dose-response curves were analyzed by a linear-quadratic model, frequencies per 1000 CB cells were ($0.31{\pm}0.049$)D+($0.0022{\pm}0.0002)D^2+(13.19{\pm}1.854) (r^2=1.000,\;X^2=0.7074,\;p=0.95$) following $\gamma$ irradiation, and ($0.99{\pm}0.528$)\;D+(0.0093{\pm}0.0047)\;D^2+(13.31{\pm}7.309)\;(r^2=0.996,\;X^2=7.6834,\;p=0.11) following neutrons irradiation (D is irradiation dose in cGy). The relative biological effectiveness (RBE) of neutrons compared with $\gamma$-rays was estimated by best fitting linear-quadratic model. In the micronuclei frequency between 0.05 and 0.8 per cell, the RBE of neutrons was $2.37{\pm}0.17$. Since the MN assay is simple and rapid, it may be a good tool for evaluating the $\gamma$-ray and neutron response.

  • PDF

400 MeV/nucleon 12C Ions Shielding Benchmark Calculations using MCNPX with Different Nuclear Data Libraries (400 MeV/nucleon 12C 이온의 MCNPX 와 핵자료를 이용한 차폐 벤치마킹 계산)

  • Shin, Yun Sung;Kim, yong min;Kim, dong hyun;Jung, nam suk;Lee, hee seock
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.5
    • /
    • pp.295-300
    • /
    • 2015
  • There are various type of particle accelerators such as Kyoungju 100-MeV proton beam accelerator in Korea. And Korea plans to build large particle accelerator such as heavy ion accelerator and 4th generation light source facility. The accelerated high energy particles of these facility produce 2nd neutron after nuclear reaction with target materials. And then these 2nd neutron activate structural materials and surrounding environment. Accordingly, it is important to consider the activation and shielding calculation on design of facility for safety operation. In this study, we tried to calculate and compare the neutron flux from the interaction $^{la}150$ beam with target material(Cu) according to thickness of iron and concrete shielding material by MCNPX 2.7 with nuclear library JENDL/HE 07and la150. To verify the properties of nuclear library, we compared computational results with experimental value. These results can be used for dose evaluation technology in planning of the shielding of large particle accelerator.

External Auditing on Absorbed Dose Using a Solid Water Phantom for Domestic Radiotherapy Facilities (고체팬텀을 이용한 국내 방사선 치료시설의 흡수선량에 대한 조사)

  • Choi, Chang-Heon;Kim, Jung-In;Park, Jong-Min;Park, Yang-Kyun;Cho, Kun-Woo;Cho, Woon-Kap;Lim, Chun-Il;Ye, Sung-Joon
    • Radiation Oncology Journal
    • /
    • v.28 no.1
    • /
    • pp.50-56
    • /
    • 2010
  • Purpose: We report the results of an external audit on the absorbed dose of radiotherapy beams independently performed by third parties. For this effort, we developed a method to measure the absorbed dose to water in an easy and convenient setup of solid water phantom. Materials and Methods: In 2008, 12 radiotherapy centers voluntarily participated in the external auditing program and 47 beams of X-ray and electron were independently calibrated by the third party’s American Association of Physicists in Medicine (AAPM) task group (TG)-51 protocol. Even though the AAPM TG-51 protocol recommended the use of water, water as a phantom has a few disadvantages, especially in a busy clinic. Instead, we used solid water phantom due to its reproducibility and convenience in terms of setup and transport. Dose conversion factors between solid water and water were determined for photon and electron beams of various energies by using a scaling method and experimental measurements. Results: Most of the beams (74%) were within ${\pm}2%$ of the deviation from the third party's protocol. However, two of 20 X-ray beams and three of 27 electron beams were out of the tolerance (${\pm}3%$), including two beams with a >10% deviation. X-ray beams of higher than 6 MV had no conversion factors, while a 6 MV absorbed dose to a solid water phantom was 0.4% less than the dose to water. The electron dose conversion factors between the solid water phantom and water were determined: The higher the electron energy, the less is the conversion factor. The total uncertainty of the TG-51 protocol measurement using a solid water phantom was determined to be ${\pm}1.5%$. Conclusion: The developed method was successfully applied for the external auditing program, which could be evolved into a credential program of multi-institutional clinical trials. This dosimetry saved time for measuring doses as well as decreased the uncertainty of measurement possibly resulting from the reference setup in water.

Implementation of Radiotherapy Educational Contents Using Virtual Reality (가상현실 기술을 활용한 방사선치료 교육 콘텐츠 제작 구현)

  • Kwon, Soon-Mu;Shim, Jae-Goo;Chon, Kwon-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.409-415
    • /
    • 2018
  • The development of smart devices has brought about significant changes in daily life and one of the most significant changes is the virtual reality zone. Virtual reality is a technology that creates the illusion that a 3D high-resolution image has already been created using a display device just like it does in itself. Unrealized subjects are forced to rely on audiovisual materials, resulting in a decline in the concentration of practices and the quality of classes. It used virtual reality to develop effective teaching materials for radiology students. In order to produce a video clip bridge using virtual reality, a radiology clinic was selected to conduct two exposures from July to September 2017. The video was produced taking into account the radiology and work flow chart and filming was carried out in two separate locations : in the computerized tomography unit and in the LINAC room. Prior to filming the scenario and the filming route were checked in advance to facilitate editing of the video. Modeling and mapping was performed in a PC environment using the Window XP operating system. Using two leading virtual reality camera Gopro Hero, CC pixels were produced using a 4K UHD, Adobe, followed by an 8 megapixel resolution of $3,840{\times}2,160/4,096{\times}2,160$. Total regeneration time was performed in about 5 minutes during the production of using virtual reality to prevent vomiting and dizziness. Currently developed virtual reality radiation and educational contents are being used to secure the market and extend the promotion process to be used by various institutions. The researchers will investigate the satisfaction level of radiation and educational contents using virtual reality and carry out supplementary tasks depending on the results.

Evaluation of Indoor Air Quality in a Department of Radiation Oncology Located Underground (지하에 위치한 방사선종양학과에서의 실내공기 질 평가)

  • Kim, Won-Taek;Shin, Yong-Chul;Kang, Dong-Mug;Ki, Yong-Kan;Kim, Dong-Won;Kwon, Byung-Hyun
    • Radiation Oncology Journal
    • /
    • v.23 no.4
    • /
    • pp.243-252
    • /
    • 2005
  • Purpose: Indoor air quality (IAQ) in the radiation treatment center which is generally located underground is important to the health of hospital workers and patients treated over a long period of time. this study was conducted to measure and analyze the factors related to IAQ and subjective symptoms of sick building syndrome, and to establish the causes influencing IAQ and find a solution to the problems. Methods and Materials : Self administrated questionnaire was conducted to check the workers' symptoms and understanding of the work environment. Based on a preliminary investigation, the factors related to IAQ such as temperature, humidity, fine particulate. carbon dioxide, carbon monoxide, formaldehyde, total volatile organic compounds (TVOC), and radon gas were selected and measured for a certain period of time in specific sites where hospital workers stay long in a day. And we also evaluated the surrounding environment and the efficiency of the ventilating system simultaneously, and measured the same factors at the first floor (outdoor) to compare with outdoor all quality, All collected data were assessed by the recommended standard for IAQ of the domestic and international environmental organizations. Results: Hospital workers were discontented with foul odors, humidity and particulate. They complained symptoms related to musculo-skeletal system, neurologic system, and mucosal-irritatation. Most of the factors were not greater than the recommended standard, but the level of TVOC was third or fourth times as much as the measuring level of some offices in the United States. The frequency and the amount of the ventilating system were adequate, however, the problem arising in the position of outdoor-air inlets and indoor-air outlets involved a risk of the indraft of contaminated air. A careful attention was a requirement in handling and keeping chemical substances including a developing solution which has a risk of TVOC emissions, and repositioning the ventilating system was needed to solve the contaminated-air circulation immediately Conclusion We verified that some IAQ-related factors and inadequate ventilating system could cause subjective symptoms in hospital workers. The evaluation of IAQ was surely needed to improve the underground working environments for hospital workers and patients. On the basis of these data, from now on, we should actively engage in designs of the department of radiation oncology or improvement in environments of the existing facilities.

A Study on the Analysis of Virus Barrier Materials in a Chest X-ray Laboratory to Respiratory and Droplet Infections Only Patients (호흡기 및 비말감염 환자 전용 흉부 X-선 검사실의 바이러스 차단제 분석에 관한 연구)

  • Kim, Hyeon-Ju;Lee, Jun-Ho;Choi, Kwan-Yong
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.2
    • /
    • pp.169-175
    • /
    • 2022
  • In this study, envisioned a laboratory equipped with virus blocking equipment for chest X-ray examinations of respiratory or droplet-transmitted virus-infected patients, and the material with the least deterioration in X-ray output and image quality among the proven blocking materials that block viruses in the design process. and experimented to find the thickness. As a result, when 1 cm of acrylic was applied, the X-ray output was reduced by only about 3.27 % compared to the absence of the barrier material, the SNR was 40.7 and CNR was 30.9, which was the best. The SSIM index result was analyzed as 0.891, which was analyzed to be implemented as the most similar image compared to the original image. The barrier material applied in the research method was objective in that it used a product approved by the Ministry of Food and Drug Safety. the results of this study are expected to provide useful information when installing X-ray examination facilities for the diagnosis and treatment of respiratory-related virus-infected patients in the future.

병원에서의 산업보건관리

  • Jeon, Gyeong-Ja
    • Korean Journal of Occupational Health Nursing
    • /
    • v.2
    • /
    • pp.40-51
    • /
    • 1992
  • 본 연구는 병원에서의 산업보건관리 실태를 파악하기 위하여 전국에 있는 병원을 대상으로 1992년 12월 1일부터 1993년 1월 23일까지 설문조사를 설시하였다. 설문조사에 응당한 병원은 41개병원으로 회수율은 51.9%였다. 조사에 이용된 설문지는 산업안전보건법 내용을 기초로 하여 본 연구자가 작성한 것이며 안전보전에 관한 제반 규정, 안전보건관리체계, 근로자건강관리, 작업환경관리, 보건교육, 보건관련시설, 질병 및 상해에 대한 보상 등에 관한 45개문항으로 구성되어 있다. 분석결과는 다음과 같다. 첫째, 전체 병원 중 68.3%가 안전보건관리 규정이 있다고 답하였으며, 77.5%의 병원이 단체협약 중 근로자의 안전과 보건에 관한 조항을 포함시키고 있는 것으로 나타났다. 단체협약에 포함된 내용 중에는 정기건강진단(23.7%)과 질병 및 상해에 대한 보상(20.9%), 안전보건위원회의 구성(18.1%)등이 많았다. 둘째, 대상 병원중 66.7%가 안전보건관리책임자, 관리감독자, 안전담당자를 두고 있는 것으로 나타났고, 근로자수가 1,000명 이상인 병원은 83.3%가 이들 인력을 선임하고 있다. 그러나, 보건관리자와 안전관리자를 전담으로 두고 있는 경우는 한 곳도 없었으며 50%이내에서 겸직으로 선임하고 있었다. 또한, 안전보건위원회를 운영하고 있거나 노사협의회로 이를 대치하고 있는 병원은 54.2%로 절반 수준에 머물렀고, 그나마 정기적으로 운영을 하고 있다고 답한 병원은 3개 병원 밖에 되지 않았다. 세째, 근로자 건강관리를 위한 건강진단 실시 현황을 보면, 채용시검진 97.6%, 일반건강진단 100.0%, 특수 건강진단 24.4%가 실시하고 있었다. 건강진단에서 주로 실시하고 있는 항목은 흉부 X선검사, 시력, 혈압, 혈청GOT/GPT, 체중, 신장등이었다. 그러나, 병원에서 감염될 수 있는 기회가 높은 간염항원/항체검사의 실시율은 85.7%로 아직도 실시하지 않는 병원이 있음을 알 수 있다. 네째, 작업환경관리를 위하여 정기적으로 환경측정을 실시하는 병원은 21.6%였고 주로 측정하는 항목은 방사선이었다. 특히 소음, 조명, 분진에 대한 측정이 이루어지지 않음은 근로자뿐아니라 환자의 안위에도부정적인 영향을 미칠 수 있다. 다섯째, 안전한 작업과 근로자의 건강을 위하여 정기적인 보건교육을 설시하고 있는 병원은 불과 5.6%였다. 교육내용은 주로 안전에 관한 것이었다. 여섯째, 근로자의 일상적인 건강문제를 해결해주는 의무실을 독립적으로 마련하고 있는 병원은 한 곳도 없었고, 교대근무자나 당직자를 위한 수면시설은 44.7%, 작업 후에 사용할 수 있는 샤워시설은 35.1%의 병원이 마련하고 있었다. 일곱째, 근무중 다치거나 병에 걸렸을 때 치료비에 대한 부담은 대체로 병원이 하고 있으며 치료기간 중 근무는 병가나 휴직으로 처리되고 있다. 이는 병원이 산재보상보험법에 적용을 받지 않은 사업으로 분류되어 있는 현실에 기인된 것으로 보상과 관련된 부담을 병원이나 근로자 모두가 안게 되는 결과를 초래하게 되는 것이다. 이상에서 볼 때 병원근로자를 위한 산업보건관리는 주로 건강진단과 질병 및 상해에 대한 보상제도가 이루어지고 있는 실정이다. 그러므로 질병의 예방이나 악화방지 나아가 건강증진을 도모하기 위한 지속적인 노력을 기울이고 있는 병원은 전무한 상태임을 알 수 있다. 이러한 현실을 병원근로자를 위한 산업보건관리에 대한 인식이 전반적으로 부족함을 드러내는 것으로 이를 개선하기 위한 보다 적극적인 노력이 시급히 요청되고 있다.

  • PDF

Evaluation on Management of Unified Health Subcenters (통합보건지소 운영 평가)

  • Kang, Pock-Soo;Lee, Kyeong-Soo;Hwang, Tae-Yoon;Kim, Chang-Yoon
    • Journal of agricultural medicine and community health
    • /
    • v.28 no.1
    • /
    • pp.67-77
    • /
    • 2003
  • Objectives: This study is designed to suggest the health service goals necessary for providing the more efficient services relevant to the requests of the community, through the evaluation on the operating status of the unified health subcenters. Methods: We visited total 5 unified health subcenters comprising 3 ones located in Gyeongsangbuk-do and 2 ones located in Gyeongsangnam-do from December 2000 to January 2001, and interviewed about the pre- and post-unified status related to manpower, facilities, equipment, medical service and health service quality, and the problems and improvement plans of the unified management. Results: According to the evaluation on the manpower before and after the unification of the health subcenters, the total employees increased by 2.8 persons on average from 6.8 to 9.6 persons in the investigated subjects. The numbers of doctors, dentists and nurses were almost the same as before. There were no clinical pathologic technician and radiological technician before but they were appointed to duty in 3 unified health subcenters later. The unification of the health subcenters has produced slight increases in the frequency of the medical service and dental treatment and considerable increases in that of the physical therapy and laboratory tests. In relating to the changes of the health service, the cases of visiting health care and ambulatory medical service, and the total number of health education participants were greatly increased after the unification. The number of cases undergoing the vaccination and cervical cancer screening was similar to that of the pre-unification while the patient number of the registration to hypertension or diabetes showed a tendency to increase a little. Since the unification of the health subcenters, the frequency of laboratory tests has been increased, but the quality of health service has not been improved yet. Nevertheless, the unification seems to be positive according to the result of the great improvement in visiting health care, ambulatory medical service and health education service. The problems of the unification of the health subcenters were indicated in indefiniteness of the service details between the workers; excessively large building hard to be effectively managed; insufficient medical instruments, inappropriation of working expenses, lack of professional training for the health education, etc. Conclusions: For further active functions of the unified health subcenters, the minimal allocation basis to appoint doctors, nurses and administrative workers to do the duty should be differentiated from the basis for a health subcenter, and the fundamental instruments needs to be expanded to improve the quality of the medical service and visiting health care service. Moreover, the unified health subcenter needs to have definite service details between the workers, and should improve the working efficiency through the development of service-related guidelines.

  • PDF