• Title/Summary/Keyword: 방사선노출

Search Result 455, Processing Time 0.037 seconds

Analysis of breast shielding rate of bismuth shield (비스무스 차폐체의 유방 차폐율 분석)

  • Kim, Jae Seok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.9
    • /
    • pp.1132-1137
    • /
    • 2020
  • In order to reduce unnecessary exposure doses generated when mammography is performed using a mammography device, a shielding ratio analysis was performed when a self-made shielding body made of bismuth was applied to the breast opposite to the imaging site. In order to determine the scattering dose of uncompressed breasts during CC and MLO tests when the right and left are compressed, the experiment is divided into when bismuth is not shielded (Not used: NU group) and when shielded (Used: U group). Proceeded. The average dose of the NU group was 9.568μSv, and the average dose of the U group was 1.038μSv. The average measured dose before and after the use of the bismuth shield was reduced by 89.15%. The use of a bismuth shield for mammography can shield scattered radiation and keep exposure to radiation to a minimum.

A Study of Below Knee Surrounding Dose depends on whether Using Collimator Shielding or not while Percutaneous Coronary Intervention (경피적 관상동맥 중재술 시 차폐 유·무에 따른 슬 하부 주변부 선량에 관한 연구)

  • Park, Jae Jin;Ko, Seong Jin;Kang, Se Sik;Kim, Chang Soo;Kim, Jung Hoon;Kim, Dong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.5
    • /
    • pp.353-358
    • /
    • 2013
  • Recently, the Percutaneous Coronary Intervention has become a main treatment for treating Coronary because of increase of Circulatory Disease. Because of this reason, the increase of intervention using radiation causes the radiation exposure to workers. Therefore, the latent radiation injury can be increased. Thus, this study/experiment measured around under knee whether using radiation collimator shielding or not. We measured the exposure does by the experiment methods which are using 60kV, 200mA, and 10ms of Automatic exposure conditions and using the major method of the Cinefluography of Coronary in our hospital. As the result of right coronary artery test cases, LAO $30^{\circ}$ when the curtains if you use lead 98.4%, $Cranial30^{\circ}$ 98.3% have a protective effect of the radiation. left circumflex coronary artery test cases, Caudal $30^{\circ}$ if the shielding effect of 90.2%, Caudal $30^{\circ}LAO$ $30^{\circ}$ 88.7% have a protective effect of the radiation. left anterior descending artery test cases, Cranial $30^{\circ}$ 98.3%, Cranial $30^{\circ}RAO$ $30^{\circ}$ 80.3%, Cranial $30^{\circ}$LAO $30^{\circ}$ 98% of the radiation has a protective effect. OS(Spider view) in the case of test Caudal $40^{\circ}LAO$ $40^{\circ}$ 71.2% appeared to have the effect of radiation shielding. For these reasons, radiation workers need to be aware on taking care of their radiation exposure by using the radiation collimator shielding even though it is uncomfortable for them.

Quality Properties of the Refrigerated or Frozen Irradiated Beef Patty (방사선조사된 패티용 분쇄우육의 가열전 품질특성)

  • Jeon, Ki-Hong;Oh, Se-Wook;Lee, Nam-Hyouck;Kim, Yun-Ji;Park, Ki-Jae;Kim, Young-Ho
    • the MEAT Journal
    • /
    • s.36 summer
    • /
    • pp.72-86
    • /
    • 2009
  • Microbial reduction, physicochemical property, and sensory evaluation of irradiated beef patty were investigated. The microbial counts of refrigerated beef patty were reduced to below the number of 3 logs after irradiation at 3 kGy. But no viable microorganism was detected in frozen beef patty irradiated at 3 kGy. Food additives such as nitrite, salt, phosphate and ascorbic acid did not affect on the inactivation of microorganism by irradiation. The irradiation effect on the water holding capacity was not significant, but frozen irradiated beef patty showed higher water holding capacity than refrigerated beef patty. The drip loss of irradiated beef patty did not show significant differences according to irradiation doses. Considering the influence of food additives, the irradiated beef patty mixed with salt and phosphate showed lower drip loss than that without food additives. In refrigerated beef patty, TBARS values were increased with increase of irradiation doses and showed lower values in the beef patty mixed with food additives than that without food additives. The redness of refrigerated beef patty showed highest values at 3 kGy of irradiation and then decreased with increasing irradiation doses, while in the frozen beef patty did not show distinct tendency according to the irradiation doses or food additives. In sensory evaluation. the irradiated beef patty showed unpleasant smell as compared with the non irradiated beef patty, but showed somewhat higher score in smell at the sample contained ascorbic acid regardless of irradiation doses.

  • PDF

Quality Properties of the Refrigerated or Frozen Irradiated Beef Patty (방사선조사된 패티용 분쇄우육의 가열전 품질특성)

  • Jeon, Ki-Hong;Oh, Se-Wook;Lee, Nam-Hyouck;Kim, Yun-Ji;Park, Ki-Jae;Kim, Young-Ho
    • Food Science of Animal Resources
    • /
    • v.28 no.4
    • /
    • pp.437-444
    • /
    • 2008
  • Microbial reduction, physicochemical property, and sensory evaluation of irradiated beef patty were investigated. The microbial counts of refrigerated beef patty were reduced to below the number of 3 logs after irradiation at 3 kGy. But no viable microorganism was detected in frozen beef patty irradiated at 3 kGy. Food additives such as nitrite, salt, phosphate and ascorbic acid did not affect on the inactivation of microorganism by irradiation. The irradiation effect on the water holding capacity was not significant, but frozen irradiated beef patty showed higher water holding capacity than refrigerated beef patty. The drip loss of irradiated beef patty did not show significant differences according to irradiation doses. Considering the influence of food additives, the irradiated beef patty mixed with salt and phosphate showed lower drip loss than that without food additives. In refrigerated beef patty, TBARS values were increased with increase of irradiation doses and showed lower values in the beer patty mixed with food additives than that without food additives. The redness of refrigerated beef patty showed highest values at 3 kGy of irradiation and then decreased with increasing irradiation doses, while in the frozen beef patty did not show distinct tendency according to the irradiation doses or food additives. In sensory evaluation, the irradiated beef patty showed unpleasant smell as compared with the non irradiated beef patty, but showed some-what higher score in smell at the sample contained ascorbic acid regardless of irradiation doses.

Measuring external Radiation dose Ratio by Traits of Patients during Positron Emission Tomography(PET) (양전자단층촬영(PET)시 환자의 특성에 따른 외부 방사선량률 측정)

  • Cho, Yong-Gwi;Kim, Sung-Chul;Ahn, Sung-Min
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.12
    • /
    • pp.860-868
    • /
    • 2013
  • The purpose of this study is to ensure safety by measuring External radiation dose ratio (ERDR) by traits of patients in many ways after administering radiopharmaceutical($^{18}F$-FDG) for PET Torso scan, and to decrease ERDR of those to RI technologist, caretakers, and those who frequently exposed to radiation by arousing attention to radiation dose. Radiopharmaceutical was administered to 80 patients who conducted PET Torso from January to June, 2013. Radiation dose emitted from the patients was measured according to body shape(BMI), water hydration, height, amount of radiation administration. From the moment immediately after the radiopharmaceutical was administered, ERDR was measured by personal traits of patients. The radiation dose increased in proportion to the administered amount of the radiopharmaceutical, and there was no significant difference depending on the body shape of the patients. When water was supplied and the height was normal, the radiation dose was lower compared with the cases where water was not supplied and height was not normal. There is a need for making efforts to minimize the working time through sufficient education and mock training before those who RI technologist with sources of radiation for complying the radiation safety management rule. And they should minimize the ERDR by wearing a protective gear.

Relationship of Admission Type, College-Life Satisfaction and College Student Academic Achievement of Radiologic Science(Technology) Students (방사선(학)과 학생들의 대학입학유형, 학업성취도, 대학생활만족도의 상관관계에 관한 연구)

  • Cho, Young-Kwon
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.12
    • /
    • pp.124-131
    • /
    • 2016
  • This study was conducted to serve as a basis for education by identifying the correlation of college admission type, college-life satisfaction and academic achievement of radiologic science students. Data were collected from 2 universities and 2 colleges located in Gyeonggi Provice, North Chungcheong Province, North Gyeongsang Province. A total of 371 questionnaires were collected, 363 of which were included in this study. The results showed that there were no differences in academic achievement according to the type of college admission. It could be able to interpret that since department of radiologic science is popular, students with high academic records applies the department of radiologic science and there are less deviation of academic records among students. A correlation analysis of academic achievement showed learning attitude is a statistically valid factor. Learning attitudes can be changed by exposure to the environment. This will require a variety of program development for improving learning attitudes. In addition, academic achievement of radiologic science students is associated with license acquisition. It need to be made together research on determinants and development of learning method to improve the learning attitude.

Assessment of Entrance Surface Dose and Image Distortion in Accordance with Abdominal Obesity in the Chest Radiography (흉부 X-선 검사에서 복부비만에 따른 입사표면선량과 영상 왜곡도 평가)

  • Kim, Boo Soon;Park, Jeong Kyu;Kwon, Soon Mu
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.7
    • /
    • pp.473-478
    • /
    • 2015
  • Abdominal obesity is one of the most influential index to predict of insulin resistance syndrome/metabolic syndrome in social demographic characteristics. It is matter of fact that radiation dose are increasing with development of medical treatment and device. In this study, we estimated distortion between reference image and entrance surface dose when take a chest radiography forward chest phantom assumed abdominal obesity. When angle of chest phantom incline $5^{\circ}$ forward, thoracic transverse and longitudinal diameter increase 1.22% and 0.44% each. Also cardiac transverse diameter increase 1.01% and cardio-throracic ratio (CTR) decrease 0.27% in the same situation of incline to $5^{\circ}$ forward. Thoracic transverse diameter shows the largest increase, and CTR was decreased. But entrance surface dose to phantom increase significantly 6.12% when angle of chest phantom incline $5^{\circ}$ forward. In conclusion, we have to pay attention to accurate positioning, to prevent a distortion of image through incline, and make patients not to expose to additional radiation.

Evaluation of Biological Effects of Low Concentrations of Mercury Chloride (II) and Ionizing Radiation in the Prepubertal Male Rats (미성숙 웅성 흰쥐를 이용한 이온화 방사선 조사 및 저농도 염화수은(II)의 음용에 따른 위해성 비교 평가)

  • Kim Ji Hyang;Kim Jin Kyu;Yoon Yong Dal
    • Korean Journal of Environmental Biology
    • /
    • v.22 no.3
    • /
    • pp.411-418
    • /
    • 2004
  • Mercury, one of the most diffused and hazardous organ-specific environmental contaminants, exists in a wide variety of physical and chemical states. The murcury with the nature which evaporates easily can cause an acute or chronic mercury poisoning to workers at mercury-handling workplaces. Although many studies indicate that mercury induces a deleterious damage, little has been reported from the investigations of mercury effects at surrounding levels in living things. The purpose of this study was to evaluate the biological effects of mercury chloride and ionizing radiation. Prepubertal male F344 rats were administered mercury chloride in drinking water throughout the experimental period or were given wholebody irradiation with a dose of 6.5 Gy. The amount changed of body weight during the experimental period showed a 4.9% rise in the mercury-treated group and 14.4% decline in the irradiated group compared with the level of the control group. The results of hematological analysis (red blood cells, white blood cells, hemoglobin, and hematocrit) indicated the differential effects of mercury chloride and ionizing radiation. However the concentration of cortisol as assessed by radioimmunoassay increased in both of the groups. Relative expressions of mRNA related to mitochondrion-mediated apoptosis were investigated using semiquantitative reverse transcription polymerase chain reaction on gonad and urinary organs of the experimental groups. While the expression of Bcl-2 mRNA exhibited different patterns depending on the organs or the experimental groups, both of the experimental groups showed a conspicuous expressions of Bax mRNA. In conclusion, the target organ of mercury chloride seems to be a urinary organ and the pattern of damage induced by mercury chloride differs from that by ionizing radiation.

The Comparison of Image Quality between Computed Radiography(CR) and Direct Digital Radiography(DDR) which Follows the Proper Exposure Conditions in General Photographing under the Digital Radiography(DR) (Digital Radiography 환경하에서 일반촬영시 적정 노출조건에 따른 CR과 DDR의 Image Quality 비교)

  • Kim, Jin-Bae;Kang, Chung-Hwan;Kang, Sung-Jin;Park, Soo-In;Park, Jong-Won;Kim, Yeong-Su;Kim, Seung-Sik
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.5 no.1
    • /
    • pp.64-77
    • /
    • 2002
  • DR has had an important fact not only in the department of radiology but also in productivity or work efficiency of a whole hospital. The environment of DR has more various parameter than CR, so it is able to supply high quality of medical services. The current environment of radiology department in each hospital has been changed from Film-Screen system to DR through Full-PACS. This hospital which uses Full-PACS became to study the proper condition of CR and DDR and how the image quality of them is expressed among general photographing systems in the DR environment. From this experiment, the image quality of DDR is better than CR under the same exposure condition. And in the DDR system, the score of image which uses AEC is a little higher than the score which doesn't use it. Especially it can be known that the function of AEC of DDR is useful to improve the image quality in the part of skull and chest. (The function of AEC : It is the tool that detects the ionized current of x-ray which goes through objects with using the ion chamber which is in the detector. Also it controls the examination of X-ray when the proper density is reached.) Because the proper degree of density can be represented by this system, the photographing can be taken much easily without consideration of the exposure condition with the thickness of various objects. From the result of this experiment, it can be known that the selection of proper exposure condition plays an important rule to gain good Image Quality. More researches will be necessary about DDR system which has potential ability in the future.

  • PDF

Heteroepitaxial Growth of ZnO Thin Films by PLD (레이저증착법을 이용한 ZnO 이종에피탁시 박막성장)

  • 박재영;이병택;김상섭;이재목;제정호
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.113-113
    • /
    • 2003
  • ZnO 박막은 p형 도핑방법이 점차 알려 지면서 최근 차세대 발광소자 재료로서 주목을 받고 있으며, 우수한 전자 이동도, 우수한 홀 이동도, 발광 스펙트럼(PL) 피크의 날카로움, 높은 free exciton binding energy, 방사선 노출에 대한 큰 내구성, 습식 식각이 가능, 동종 기판 사용이 가능함으로써 박막의 품질을 개선할 수 있고 제조공정을 간소화할 수 있는 등의 장점을 지니고 있어 이에 관련된 많은 연구들이 진행되고 있다. 특히 ZnO 박막을 차세대 발광소자로 응용하기 위해서는 고품질의 에피탁시 박막을 성장시켜야 하며 이를 위하여 MBE, MOCVD, PLD법 등 다양한 에피탁시 박막증착이 시도되고 있다. 또한 보다 양질의 ZnO 박막을 성장시키기 위해 적절한 단결정 기판 및 버퍼층의 탐색과 각 기판에 따른 ZnO 박막의 물성평가 작업도 진행되고 있다.

  • PDF