• Title/Summary/Keyword: 방사선검출기

Search Result 569, Processing Time 0.028 seconds

Technical Status of Environmental Radiation Monitoring using a UAV and Its Field Application to the Aerial Survey (무인기를 이용한 광역부지 환경방사선측정 기술 현황 및 현장 적용 연구)

  • Ji, Young-Yong;Min, Byung Il;Suh, Kyung-Suk;Joung, Sungyeop;Kim, Kyoung-Pyo;Park, Jin-Ho
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.25 no.5
    • /
    • pp.31-39
    • /
    • 2020
  • According to lessons learned from an accident of Fukushima Daiichi nuclear power plant, it is advisable to make a comprehensive radiation survey by the accident phase for efficient response and risk management using diverse survey platforms. This study focuses on the technical status of environmental radiation monitoring using a UAV (Unmanned aerial vehicle) and the performance test of developed aerial survey system based on two detectors with an high energy resolution through the field application to contaminated areas. Finally, the performance of aerial survey at diverse flight heights was successfully achieved by introducing the correction factor to represent the results into ambient dose rate at 1m above the ground.

Semiconductor Detectors for Radiation Imaging Applications (방사선 영상 장치용 반도체 검출기)

  • Park, K.S.;Park, J.M.;Yoon, Y.S.;Kim, B.W.;Kang, J.Y.
    • Electronics and Telecommunications Trends
    • /
    • v.22 no.5
    • /
    • pp.95-107
    • /
    • 2007
  • X-선 측정 및 영상장치를 포함한 다양한 응용분야에서 방사선에 대한 고해상도의 영상을 얻기 위한 목적으로 반도체 검출기에 대한 개발이 활발히 진행되고 있다. 본 고에서는 방사선 검출을 위해 요구되는 반도체 물질의 주요 특성에 대해서 조사하였다. 또한 반도체를 이용한 플랫 패널(flat panel) 시스템, 픽셀 디텍터(pixel detector)와 스트립 디텍터(strip detector) 등의 혼성형 디텍터(hybrid detector), MAPS와 DEPFET 등의 단일형 픽셀 디텍터(monolithic pixel detector)의 디바이스 동작 원리 및 특성과 국내외 기술 동향에 대하여 살펴보았다.

In Vivo Dosimetry with MOSFET Detector during Radiotherapy (방사선 치료 중 MOSFET 검출기를 이용한 체표면 선량측정법)

  • Kim Won-Taek;Ki Yong-Gan;Kwon Soo-Il;Lim Sang-Wook;Huh Hyun-Do;Lee Suk;Kwon Byung-Hyun;Kim Dong-Won;Cho Sam-Ju
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.17-23
    • /
    • 2006
  • In Vivo dosimetry is a method to evaluate the radiotherapy; it is used to find the dosimetric and mechanical errors of radiotherapy unit. In this study, on-line In Vivo dosimetry was enabled by measuring the skin dose with MOSFET detectors attached to patient's skin during treatment. MOSFET dosimeters were found to be reproducible and independent on beam directions. MOSFET detectors were positioned on patient's skin underneath of the dose build-up material which was used to minimize dosimetric error. Delivered dose calculated by the plan verification function embedded in the radiotherapy treatment planning system (RTPs), was compared with measured data point by point. The dependency of MOSFET detector used in this study for energy and dose rate agrees with the specification provided by manufacturer within 2% error. Comparing the measured and the calculated point doses of each patient, discrepancy was within 5%. It was enabled to verify the IMRT by using MOSFET detector. However, skin dosimetry using conventional ion chamber and diode detector is limited to the simple radiotherapy.

  • PDF

Study on Improvement of Signal to Noise Ratio for HgI2 Radiation Conversion Sensor Using Blocking Layer (Blocking layer 적용을 통한 HgI2 방사선 변환센서의 신호대 잡음비 향상에 관한 연구)

  • Park, Ji-Koon;Yoon, In-Chan;Choi, Su-Rim;Yoon, Ju-Sun;Lee, Young-Kyu;Kang, Sang-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.2
    • /
    • pp.97-101
    • /
    • 2011
  • In this study, the basic research verifying possibility of applications as radiology image sensor in Digital Radiography was performed, the radiology image sensor was fabricated using double layer technique tio decrease dark current. High efficiency material in substitution for a-Se have been studied as a direct method of imaging detector in Digital Radiography to decrease dark current by using Hetero junction already used as solar cell, semiconductor. Particle-In-Binder method is used to fabricate radiology image sensor because it has a lot of advantages such as fabrication convenient, high yield, suitability for large area sensor. But high leakage current is one of main problem in PIB method. To make up for the weak points, double layer technique is used, and it is considered that high efficient digital radiation sensor can be fabricated with easy and convenient process. In this study, electrical properties such as leakage current, sensitivity is measured to evaluate double layer radiation sensor material.

Development of a Portable Device Based Wireless Medical Radiation Monitoring System (휴대용 단말 기반 의료용 무선 방사선 모니터링 시스템 개발)

  • Park, Hye Min;Hong, Hyun Seong;Kim, Jeong Ho;Joo, Koan Sik
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.3
    • /
    • pp.150-158
    • /
    • 2014
  • Radiation-related practitioners and radiation-treated patients at medical institutions are inevitably exposed to radiation for diagnosis and treatment. Although standards for maximum doses are recommended by the International Commission on Radiological Protection (ICPR) and the International Atomic Energy Agency (IAEA), more direct and available measurement and analytical methods are necessary for optimal exposure management for potential exposure subjects such as practitioners and patients. Thus, in this study we developed a system for real-time radiation monitoring at a distance that works with existing portable device. The monitoring system comprises three parts for detection, imaging, and transmission. For miniaturization of the detection part, a scintillation detector was designed based on a silicon photomultiplier (SiPM). The imaging part uses a wireless charge-coupled device (CCD) camera module along with the detection part to transmit a radiation image and measured data through the transmission part using a Bluetooth-enabled portable device. To evaluate the performance of the developed system, diagnostic X-ray generators and sources of $^{137}Cs$, $^{22}Na$, $^{60}Co$, $^{204}Tl$, and $^{90}Sr$ were used. We checked the results for reactivity to gamma, beta, and X-ray radiation and determined that the error range in the response linearity is less than 3% with regard to radiation strength and in the detection accuracy evaluation with regard to measured distance using MCNPX Code. We hope that the results of this study will contribute to cost savings for radiation detection system configuration and to individual exposure management.

A Study on the Validation of Effective Angle of Particle Deposition according to the Detection Efficiency of High-purity Germanium Gamma-ray Detector (고순도 저마늄 감마선 검출기의 검출효율에 따른 유효입체각 검증에 관한 연구)

  • Chang, Boseok
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.487-494
    • /
    • 2020
  • The distance between the source and the detector, the diameter of the detector, and the volume effect of the radiation source result in a change in solid angle at the detector entrance, which affects the determination of detection efficiency by causing a difference in path length within the detector. A typical analysis method for calculating solid angles was useful only for a source (60Co) with a simple geometric structure, so in this experiment, the distance between the detector and the source was measured by switching on for up to 25 cm with the reference point of window cap 0.5 cm. In addition, 450 and 1000 ㎖ Marinelli beaker of standard volumetric sources were closely adhered to the detector. For circular point sources co-axial with the detector, the change in the solid angle to the distance from the detector window is equal to half the square radius of the source versus the square radius of the detector, if the resulting relationship of the calculation analysis results in the detector being less than the radius of the source. Since the solid angular difference is 0.5 the result of Monte Carlo is acceptable. The relationship between detector and source distance is shown. Solid angles have been verified to decrease rapidly with distance. Measurement and simulation results for a volumetric source show a difference of ±1.01% from a distance of 0 cm and less than 4 % when the distance is reduced to 5 and 10 cm. It can be seen that the longer distance, the smaller efficiency angle, and the exponential increase in attenuation as the energy decreases, is reflected in the calculation of efficiency. Thus, the detection efficiency has proved sufficient for the use of solid angle and Monte Carlo codes.

Feasibility Study of Parallel- Plate Detector Using Dielectric film for 6 MV X-ray (6MV X-선 검출특성 조사를 위하여 유전체 필름을 이용하여 제작한 평행판 검출기의 유용성)

  • 조문준;김용은;이병용;김정기;임상욱;김현수;김기환
    • Progress in Medical Physics
    • /
    • v.15 no.2
    • /
    • pp.105-111
    • /
    • 2004
  • The parallel plate detector with dielectric film for dosimetry was designed to measure detection characteristic of 6 MV X-ray with medical linear accelerator. PTFE film was inserted into FEP films that are made by two one-side metal coated materials for ion source. The thicknesses of PTFE dielectric film was 100 ${\mu}{\textrm}{m}$ and the thickness of FEP dielectric film was 100 ${\mu}{\textrm}{m}$, respectively. This detector was fixed by two acrylic plate for physical hardness ad geometrical consistency. The geometrical condition for measurement with parallel-plate for detector was below; SSD=100 cm and the 5 cm depth between detector and phantom surface The major parameter of detector characteristics such as zero drift current, leakage current, charge response by applied voltage, reproducibility, linearity, TMR measurement, dose rate effect were measured. The zero drift currents are 8.3 pA and leakage currents are 10 pA. The charge response of applied voltage is showing linearity in 414 voltage. The measurement deviation of reproducibility in this detector is within 1% for dose and the linearity of applied dose shows in this detector. The TMR curves in phantom between this parallel plate detector and reference detector are matched within 3% deviation from maximum dose depth to 7.5 cm depth. It is considered that this dosimetric system is satisfactory for the purpose of the constancy check of the 6 MV x-ray from medical linear accelerator.

  • PDF

The Analysis of the Collimator & Radiation Shield for the Radiation Sensor for the 3Dimension Radiation Detection (3차원 방사선 탐지장치용 검출센서의 차폐체 및 Collimator 구조 분석 연구)

  • Hwang, Young-Gwan;Lee, Nam-Ho;Park, Sumg-Hun;Jeong, Sang-Hun;Kim, Jong-Ryul;Choi, Myung-Jin
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.707-709
    • /
    • 2014
  • The radiation sources leaked from large-scale radiation leak accident like the Fukushima nuclear power plant accident or nuclear explosions can cause to the very large damage for us. So that the damage can be minimized, we have being developed a detector that can providing information about the location of the source to remove dangerous substances quickly than the conventional single detector. In this paper, we designed and implemented the radiation shield and the collimator for the development of the stereo radiation detector to detect contamination things using MCNP Simulation. And we analysed the test results of the radiation shield and collimator using the radiation source. The results of this paper will be used as the basis for improving the efficiency of the stereo radiation detector being studied currently.

  • PDF