• Title/Summary/Keyword: 방사능센서

Search Result 30, Processing Time 0.027 seconds

Development of a Ranging Inspection Technique in a Sodium-cooled Fast Reactor Using a Plate-type Ultrasonic Waveguide Sensor (판형 웨이브가이드 초음파 센서를 이용한 소듐냉각고속로 원격주사 검사기법 개발)

  • Kim, Hoe Woong;Kim, Sang Hwal;Han, Jae Won;Joo, Young Sang;Park, Chang Gyu;Kim, Jong Bum
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.1
    • /
    • pp.48-57
    • /
    • 2015
  • In a sodium-cooled fast reactor, which is a Generation-IV reactor, refueling is conducted by rotating, but not opening, the reactor head to prevent a reaction between the sodium, water and air. Therefore, an inspection technique that checks for the presence of any obstacles between the reactor core and the upper internal structure, which could disturb the rotation of the reactor head, is essential prior to the refueling of a sodium-cooled fast reactor. To this end, an ultrasound-based inspection technique should be employed because the opacity of the sodium prevents conventional optical inspection techniques from being applied to the monitoring of obstacles. In this study, a ranging inspection technique using a plate-type ultrasonic waveguide sensor was developed to monitor the presence of any obstacles between the reactor core and the upper internal structure in the opaque sodium. Because the waveguide sensor installs an ultrasonic transducer in a relatively cold region and transmits the ultrasonic waves into the hot radioactive liquid sodium through a long waveguide, it offers better reliability and is less susceptible to thermal or radiation damage. A 10 m horizontal beam waveguide sensor capable of radiating an ultrasonic wave horizontally was developed, and beam profile measurements and basic experiments were carried out to investigate the characteristics of the developed sensor. The beam width and propagation distance of the ultrasonic wave radiated from the sensor were assessed based on the experimental results. Finally, a feasibility test using cylindrical targets (corresponding to the shape of possible obstacles) was also conducted to evaluate the applicability of the developed ranging inspection technique to actual applications.

Space Radiation Effect on Si Solar Cells (우주 방사능에 의한 실리콘 태양 전지의 특성 변화)

  • Lee, Jae-Jin;Kwak, Young-Sil;Hwang, Jung-A;Bong, Su-Chang;Cho, Kyung-Seok;Jeong, Seong-In;Kim, Kyung-Hee;Choi, Han-Woo;Han, Young-Hwan;Choi, Yong-Woon;Seong, Baek-Il
    • Journal of Astronomy and Space Sciences
    • /
    • v.25 no.4
    • /
    • pp.435-444
    • /
    • 2008
  • High energy charged particles are trapped by geomagnetic field in the region named Van Allen Belt. These particles can move to low altitude along magnetic field and threaten even low altitude spacecraft. Space Radiation can cause equipment failures and on occasions can even destroy operations of satellites in orbit. Sun sensors aboard Science and Technology Satellite (STSAT-l) was designed to detect sun light with silicon solar cells which performance was degraded during satellite operation. In this study, we try to identify which particle contribute to the solar cell degradation with ground based radiation facilities. We measured the short circuit current after bombarding electrons and protons on the solar cells same as STSAT-1 sun sensors. Also we estimated particle flux on the STSAT-l orbit with analyzing NOAA POES particle data. Our result clearly shows STSAT-l solar cell degradation was caused by energetic protons which energy is about 700keV to 1.5MeV. Our result can be applied to estimate solar cell conditions of other satellites.

A Study of Smart Robot Architecture and Movement for Observation of Dangerous Region (위험지역 감시스마트로봇의 설계와 동작에 관한 연구)

  • Koo, Kyung-Wan;Baek, Dong-Hyun
    • Fire Science and Engineering
    • /
    • v.27 no.6
    • /
    • pp.83-88
    • /
    • 2013
  • Catastrophic disasters are sprouting out recently, i.e., the radiation leaks and the hydrofluoric acid gas leaks, etc. The restoration work for these kinds of disasters is very harmful and dangerous for human beings to handle themselves, thus allowing manless robots to fly the reconnaissance planes over to the disaster stricken areas and do the necessary work instead. For this endeavor and purpose, we created and tested an intelligent robot that can inspect those areas, using Mbed (ARM processor) technology temperature sensors and gas sensors aided by CAM (Computer-Aided Manufacturing) cameras. Also, HTTP Server, PC, androids and their combined efforts allow their remote controlled operation from far away with timing control. These intelligent robots can be on duty for 24 hours, minimizing the accidents and crimes and what not, and can respond more quickly when these misfortunes actually happen. We can anticipate the economic effects as well, derived from the reduced needs for hiring human resources.

The Study for the Fast Detection of the Stereo Radiation Detector using the Image Processing (영상처리기반 스테레오 감마선 탐지장치의 고속탐지에 관한 연구)

  • Hwang, Young-gwan;Lee, Nam-ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.1103-1105
    • /
    • 2015
  • Leaked Radioactive source in nuclear power station, radiation related facilities and the aging nuclear power plant for the dismantling must need to detect and remove early to prevent major accidents. In this paper, we implemented a single sensor-based gamma-ray detectors stereo which can provide the distance to the radiation source, a direction and doserate information for fast and efficient decontamination work the radiation source. And we have carried out an algorithm development for high-speed detection of the detection equipment. Two detectors are required for stereo structure for obtaining the distance information of the radioactive source, but we designed the only sensor-based detection device for the weight reduction. We have extracted the region of interest and obtained the distance calculation result and distribution of radiation source in order to minimize a stereo image acquisition time. Detection time of the algorithm showed a shorter time of about 41%.

  • PDF

A study on the radiation effect of silicon solar cells in a low Earth orbit satellite by using high energy electron beams (고에너지 전자빔을 이용하여 저궤도 인공위성의 실리콘 태양센서의 내방사선 특성 연구)

  • Chung, Sung-In;Lee, Jae-Jin;Lee, Heung-Ho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.3
    • /
    • pp.1-5
    • /
    • 2008
  • This paper analyzes on the radiation effect of silicon solar cells in a low Earth orbit satellite by using high energy electron beams. Generally, the satellite circling round in a low orbit go through Van Allen belt, in which electronic components are easily damaged and shortened by charged particles moving in a cycle between the South Pole and the North Pole. For example, Single Event Upset (SEU) by radiation could cause electronic devices on satellite to malfunction. From the ground experiment in which we used the high energy electron beam facility at Knrea Atomic Energy Research Institute (KAERI), we tried to explain sun sensor degradations on orbit could he caused by high energy electrons. While we focused on the solar cells used for light detectors, We convince our research also contributes to understand the radiation effect of solar cells generating electric powers on satellites.

Development of Three-Dimensional Gamma-ray Camera (방사선원 3차원 위치탐지를 위한 방사선 영상장치 개발)

  • Lee, Nam-Ho;Hwang, Young-Gwan;Park, Soon-Yong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.2
    • /
    • pp.486-492
    • /
    • 2015
  • Radiation source imaging system is essential for protecting of radiation leakage accidents and minimizing damages from the radioactive materials, and is expected to play an important role in the nuclear plant decommissioning area. In this study, the stereoscopic camera principle was applied to develop a new radiation imaging device technology that can extract the radiation three-dimensional position information. This radiation three-dimensional imaging device (K3-RIS) was designed as a compact structure consisting of a radiation sensor, a CCD camera, and a pan-tilt only. It features the acquisition of stereoscopic radiation images by position change control, high-resolution detection by continuous scan mode control, and stereoscopic image signal processing. The performance analysis test of K3-RIS was conducted for a gamma-ray source(Cs-137) in radiation calibration facility. The test result showed that a performance error with less than 3% regardless of distances of the objects.

A Study on the Management and Application for Prevention Information Communication System (방재정보통신시스템 관리 운용 및 응용에 관한 연구)

  • Kang, Heau-Jo
    • Journal of Advanced Navigation Technology
    • /
    • v.12 no.6
    • /
    • pp.611-618
    • /
    • 2008
  • The development of information society together with information telecommunication's influence on the human society is a ripple effect and getting wider. Among those ripple effects the disaster prevention is in the public eye in the present day. On the way to the ubiquitous society the main techniques to be concerned in ubiquitous sensor networks are the field of damage of storm and flood, safety facilities, traffic safety, industrial safety, energy safety, fire fighting, specific safety of radioactivity escape incident, environmental pollution, sea pollution, mountain and forrest disaster so on. In this paper the USN technique based on the disaster prevention communication technology service and its requirement technology and application are studied.

  • PDF

Housing Analysis for Ocean Radiation Detection (해양 방사선 탐지를 위한 하우징 분석)

  • Park, Gang-teak;Kim, Jong-Yeol;Jung, Hyun-kyu;Lee, Nam-ho;Hwang, Young-gwan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.10a
    • /
    • pp.714-715
    • /
    • 2017
  • Much of the interest in ocean radiation detection has been heightened as a lot of radioactivity has leaked to the ocean due to the accident at the Fukushima nuclear power plant in Japan. In the study, MCNP simulation for radiation detection in the ocean was performed. Unlike in the air, the marine environment must ensure the stability of the sensor from water depth, temperature, pressure, and salinity. In the marine environment, too much radiation is shielded. Therefore, it is an object to select a housing with a low radiation shielding ratio.

  • PDF

Development of Neutron, Gamma ray, X-ray Radiation Measurement and Integrated Control System (중성자, 감마선, 엑스선 방사선 측정 및 통합 제어 시스템 개발)

  • Ko, Tae-Young;Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.21 no.4
    • /
    • pp.408-411
    • /
    • 2017
  • In this paper, we propose an integrated control system that measures neutrons, gamma ray, and x-ray. The proposed system is able to monitor and control the data measured and analyzed on the remote or network, and can monitor and control the status of each part of the system remotely without remote control. The proposed system consists of a gamma ray/x-ray sensor part, a neutron sensor part, a main control embedded system part, a dedicated display device and GUI part, and a remote UI part. The gamma ray/x-ray sensor part measures gamma ray and x-ray of low level by using NaI(Tl) scintillation detector. The neutron sensor part measures neutrons using Proportional Counter Detector(low-level neutron) and Ion Chamber Type Detector(high-level neutron). The main control embedded system part detects radiation, samples it in seconds, and converts it into radiation dose for accumulated pulse and current values. The dedicated display device and the GUI part output the radiation measurement result and the converted radiation amount and radiation amount measurement value and provide the user with the control condition setting and the calibration function for the detection part. The remote UI unit collects and stores the measured values and transmits them to the remote monitoring system. In order to evaluate the performance of the proposed system, the measurement uncertainty of the neutron detector was measured to less than ${\pm}8.2%$ and the gamma ray and x-ray detector had the uncertainty of less than 7.5%. It was confirmed that the normal operation was not less than ${\pm}15$ percent of the international standard.

Development of ZnS(Ag)/plastic dual scintillator sheet for simultaneous alpha- and beta-ray counting (알파 및 베타선 동시측정용 ZnS(Ag)/플라스틱 이중섬광체 검출센서 개발)

  • Seo, Bum-Kyoung;Woo, Zu-Hee;Kim, Gye-Hong;Lee, Kune-Woo;Lee, Dong-Gyu;jung, Chong-Hun
    • Analytical Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.117-122
    • /
    • 2008
  • Dual scintillator for simultaneous alpha- and beta-ray counting used by detection materials of a surface contamination monitor was developed. In this study, preparation method was not a heat melting method but a solvent method, by which the counting material was manufactured by dissolving the polymer materials with solvent. It was simplified the preparation process. Plastic scintillator for beta-ray counting was prepared by solidifying the casting solution mixed with organic scintillator, polymer, and solvent. ZnS(Ag) scintillator layer was prepared by screen printing the paste solution mixed with ZnS(Ag), paste, and solvent onto the plastic layer. The good counting ability for alpha- and beta-ray using the ZnS(Ag)/plastic dual scintillator prepared and possibility for the counting material of surface contamination monitor was confirmed.