• Title/Summary/Keyword: 반 전위

Search Result 68, Processing Time 0.02 seconds

Quantification of Half Cell Potential with Mix Properties in RC Member under Long-Term Chloride Exposure Conditions (장기 염해에 노출된 RC 부재의 배합 특성을 고려한 반 전위의 정량화)

  • Yoon, Yong-Sik;Jeong, Gi-Chan;Kwon, Seung-Jun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.3
    • /
    • pp.307-313
    • /
    • 2022
  • In this study, the correlation between Half Cell Potential(HCP) and the corrosion influencing factors was analyzed with considering three levels of water-cement ratio, the concentration of chloride solution, and cover depth. As a result of long-term corrosion monitoring, HCP behavior was close to the critical corrosion potential(-350 mV) in all water-cement ratios in the case of 3.5 % and 7.0 % chloride concentration. Regarding the passed charge test in 548 curing days, the passed charge results were improved to 'Moderate' grade. Multiple regression analysis was performed to evaluate the correlation between corrosion influencing factors and HCP, and it was evaluated that the effects of influencing factors to HCP were in the order of chloride concentration, water-cement ratio, and cover depth. In the case of the relationship between HCP and the passed charge, the coefficient of determination showed a high level of 0.9, which yielded a close correlation between the passed charge and HCP.

전위기어의 성능 및 강도설계

  • 박재춘
    • Journal of the KSME
    • /
    • v.25 no.1
    • /
    • pp.9-22
    • /
    • 1985
  • 재래의 표준기어방식으로는 여러 가지의 취약점이 있는데, 이러한 결점은 치형을 다시 교 정(correction)하는 전위기어방식으로 설계하여 성능이 개선되고 해결될 수 있다. Corrected tooth의 창성은 공구를 전위하여 절삭하므로 이루어지고, 이 방식은 치형곡선의 곡률반지름을 증가시키며, 미끄럼률을 감소시켜서 강도를 증가시키도록 설계할 수 있다. 본 해설에서는 전위 기어 영역에서 기어의 성능개선과 복잡한 강도의 설계방법등을 최근경향에 부합시키고 통일된 형식의 체계로 기어설계를 쉽게 발전시킬 수 있도록 시도한 것이다.

  • PDF

Stress Intensity Factors for Branched Edge Cracks (가지친 표면크랙의 응력확대계수)

  • 구인회
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.2
    • /
    • pp.257-264
    • /
    • 1986
  • 무한평판에 묻혀진 크랙에 대한 응력확대계수를 결정하는 전위분포법을 반무한 평판에서의 표면크랙에 확장 적용하였다. 이를 위해 반평면에서의 전위응력의 기본 해가 간단한 복소수 응력함수형태로 얻어졌다. 평형을 이루는 절편적인 분포로부터 응력확대의 계수를 계산하는 새로운 방식을 제안하였으며, 수직표면 크랙과 묻혀진 경사크랙에 대한 기존해와 이 방법의 결과가 상호 비교되었다. 경사진 표면크랙에 대한 계산결과는 유한평판에서의 기존하는 Mapping Collocation 해석과 비교되어 좋은 일치를 보여 주었다. 구부러진 크랙과 대칭으로 가지친 크랙에 대해서는 표면크랙과 묻혀진 크랙사이에 상당한 차이가 있음이 나타났다.

Dislocation analyses of semi-brittle fracture I

  • Chung, Soon-Kil;Lee, Byung-Ho
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.5 no.2
    • /
    • pp.101-109
    • /
    • 1981
  • 균일 인장하중하에 있는 고체 내부에 고립된 제 1형 탄소성 크랙의 반취성 파괴를 경사슬립밴드모델(inclined slip band model)로서 연속크랙전위(conticuum crack dislocation) 및 연속격자 전위(continum lattice dislocation)을 이용하여 이론적으로 연구하였다. 크랙전위 및 격자전위에 관한 힘평형을 나타애는 연립특이적분방정식의 해는크랙전위 및 격자전위에 관한 적정밀도함수를 가지고 특이함을 해소하는 조건을 부가하여 얻는다. 이특이항 해소조건의 타당성은 처음으로 소성영역의 크기를 그 판단기준으로 검토되었으며, 그결과 합당한 것으로 확인되었다. 또한 상기방법으로부터 산출된 COD는 소규모 성역을 넘어서도 선형적으로 .KAPPA.$^{2}$.EPSILON..sigma.$_{Y}$ 에 따라 변화함을 알게 된다. 상기모델에서 위축적분경로(Shrunk path) 상의 J 적분치를 J=.delta..sigma.$_{Y/}$sin2.theta.의 형태로 유도하였는데, 이것은 J 적분에 관한 Eshelby의 힘개념을 구체적으로 표현한다: J는 크랙전파방향으로 탄소성크랙정점에 작용하는 가상적인 힘이며, 1/2 J의 한 슬립편면상에서의 분력은 그 슬립정면사으이 보든 격자전위에 작용하는 전단력의 총화와 같다. 같다.

대기압 플라즈마 제트에서 플라즈마 Plume의 전압 변화량 측정

  • Gang, Han-Rim;Jeong, Jong-Yun;Kim, Yun-Jung;Kim, Jung-Gil;Kim, Jeong-Hyeon;Jo, Gwang-Seop
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.506-506
    • /
    • 2012
  • 플라즈마 제트 장치를 이용하여 두 개의 플라즈마 plume을 평행하게 발생시킨다. 두 개의 플라즈마 plume의 전위차를 전극에서부터 plume 끝단까지 위치별로 측정한다. 두 개의 플라즈마 제트 장치에 인가하는 전압의 위상이 서로 반대일 경우, 두 개의 플라즈마 plume의 전위차로 인하여 plume사이에 streamer가 발생한다. 대기압에서 streamer가 발생하려면 십여 kV 이상의 전위차가 있어야 한다. 반대로 동일한 위상의 전압을 인가할 경우, 두 개의 플라즈마 plume의 전위차는 없기 때문에 plume사이에 streamer가 발생하지 않는다. 두 개의 플라즈마 제트 장치를 등가회로로 구성하고 위상차로 인한 streamer 발생여부를 확인한다. 그리고 두 개의 플라즈마 plume 사이에 발생한 streamer와 플라즈마 제트 장치를 등가회로로 구성하여 발생시킨 streamer 양을 비교한다. 이를 통해 플라즈마 plume의 전위차를 확인한다.

  • PDF

A Study on the Computational Simulation of Cyclic Voltammetry using Semi-infinite Diffusion Model (반무한 확산모델을 이용한 순환전위법의 전산모사에 관한 연구)

  • Cho, Ha-Na;Kim, Tae-Yong;Yoon, Do-Young
    • Journal of the Korean Electrochemical Society
    • /
    • v.14 no.3
    • /
    • pp.138-144
    • /
    • 2011
  • The transport phenomena of electron and ion around the electrode have been analyzed, herein the computational program to simulate the electrochemical signal of cyclic voltammetry has been implemented. For the dominant mass-transfer system, the governing equation and its boundary conditions are confined to the semi-infinite diffusion model and the reversible reaction at the electrode. In order to obtain the numerical solutions of cyclic voltammetry, MATLAB was used for the explicit finite difference method. Experimental results from the cyclic voltammetry of electrochemical system(10 mM $K_3Fe(CN)_6$ and 0.1M KCl) upon the ITO glass substrate were compared with the numerical solutions. Present program explains the experimental results fairly well, where they approached the simulated ones closely with deceasing the scan rate. Furthermore, the effects of electrode area, electrochemical reaction constants and transfering coefficients in the cyclic voltammetry were discussed quantitatively.

Relationship Analysis between Half Cell Potential and Open Circuit Potential Considering Temperature Condition (온도 영향을 고려한 RC 구조의 반 전위 및 OCP의 상관성 분석)

  • Yoon, Yong-Sik;Kwon, Seung-Jun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.1
    • /
    • pp.124-132
    • /
    • 2022
  • The corrosion potential in concrete varies greatly with exposure and concrete mix conditions. In this study, RC (Reinforcement Concrete) samples were prepared considering cover depth, chloride concentration, and W/C(water to cement) ratio as variables, and HCP(Half Cell Potential) was measured, which evaluated comparative potential between embedded steel and concrete surface. In addition, OCP(Open Circuit Potential) was measured using buried steel and CE(Counter Electrode). Agar and NaOH solution were used as ion exchange materials and Hg/HgO was used for RE(Reference Electrode), which was more sensitive to temperature than HCP. Among the influencing factors, the exposure period and chloride concentration had a relatively greater effect than cover depth and w/c ratio. Additionally, the entire measured HCP and OCP showed a clearly linear relationship with increasing cover depth and w/c ratio. Through multiple regression analysis, the relationship between HCP and OCP was quantified, and an improved correlation was obtained with temperature effect.

Artificial Potential Function for Driving a Road with Traffic Light (신호등 신호에 따른 차량 주행 제어를 위한 인공 전위 함수)

  • Kim, Duksu
    • Journal of KIISE
    • /
    • v.42 no.10
    • /
    • pp.1231-1238
    • /
    • 2015
  • Traffic light rules are one among the most common and important safety rules as the directly correlate with the safety of pedestrians. Consequently, an algorithm is required to cause an automated (or semi-automated) vehicle to observe traffic light signals. We present a novel, artificial potential function to guide an automated vehicle through traffic lights. Our function consists of three potential function components representing the three traffic light colors: green, yellow, and red. The traffic light potential function smoothly changes an artificial potential field using the elapsed time for the current light and light conversion. Our traffic light potential function is combined with other potential functions to guide vehicles' movement and constructs the final artificial potential field. Using various simulations, we found or method successfully guided the vehicle to observe traffic lights while behaving like human-controlled cars.

Sliding Knots and the Effect of Additional Half-Hitch Knots on Optimal Knot-Holding Capacity (체이동 매듭과 추가적인 반 매듭 증가에 따른 매듭의 장력 변화와 최적 유지력)

  • Hur, Chang-Yong;Kim, Seung-Ho;Kim, Byung-Kwan;Yoo, Jae-Chul
    • Journal of the Korean Arthroscopy Society
    • /
    • v.8 no.1
    • /
    • pp.37-44
    • /
    • 2004
  • Purpose: To evaluate the optimal number of additional half hitches for achieving an optimal knot-holding capacity (KHC) of Lockable sliding knots. Methods: Four configurations of arthroscopic knots (Duncan loop, Field knot, Giant knot, and SMC knot) were tested for their knot-holding capacity. For each knot configuration, 6 sequential knots were made including the initial sliding knot and additional 5 knots by incrementing one half hitches at a time. Each added half-hitch were in reversing half-hitches with alternate posts (RHAPs) fashion. For each sequential knot configuration, 12 knots were made by No. 2 braided sutures. On the servo-hydraulic material testing system (Instron 8511, MTS, Minneapolis, MN), cyclic loading, load to clinical failure (3-mm displacement), load to ultimate failure, and mode of failure were measured. Results: Most of the initial loop without additional half-hitch showed dynamic failure with cyclic loading. The mean displacement after the end of cyclic loading decreased with each additional half-hitches. SMC and Giant knot reached plateau to 0.1 mm or less displacement after one additional half-hitch, shereas Field and Duncan loop needed 3 additional half-hitches. The SMC and Duncan knots needed 1 additional half-hitch to reach greater than 80N at clinical failure, whefeas the other 2 knots needed2 additional half-hitches. For the load exceeding 100N for clinical failure, the SMC knot required 3 additional half-hitches and the other three knots needed 4 additional half-hitches. As the number of additional half-hitches incremented, the mode of failure switched from pure loop failure (slippage) to material failure (breakage). Duncan loop showed poor loop security in that even with 5 additional half-hitches, some failed by slippage (17%). On the other hand, after 3 additional half-hitches, the 3 other knots showed greater than 75% of failure by material breakage mode (SMC and Field 92%, Giant 75%). Conclusion: Even with its own locking mechanism, lockable sliding knot alone does not withstand the initial dynamic cyclic load. For all tested variables, SMC knot requires a minimum of 2 additional half-hitches. Duncan knot may need more than 3 additional half-hitches for optimal security. All knots showed a mear plateau in knot security with 3 or more additional half-hitches.

  • PDF

Characteristic Analysis of Cyclic Voltammetry on a Self-Assembled Mono-layer Electrode (자가조립 단층 전극에 대한 순환전위법의 특성해석)

  • Cho, Hana;Yoon, Do-Young
    • Journal of the Korean Electrochemical Society
    • /
    • v.16 no.4
    • /
    • pp.217-224
    • /
    • 2013
  • In this paper, we have investigated the characteristics of cyclic voltammetry of a self-assembled mono-layer(SAM) electrode which was modified by 3-Mercaptopropionic acid (3-MPA) on gold nanoparticle(AuNP)-deposited electrode. Also, the transport phenomena of electrons and ions around the electrode have been analyzed. The governing equation and its boundary conditions by adopting the semi-infinite diffusion model were formulated for the mass-transfer dominant system. In order to obtain the numerical solutions of cyclic voltammetry(CV) on SAM electrodes, MATLAB program was implemented by applying the explicit finite difference method. Resulting CV program for the SAM-modified electrode was verified in good agreements with the experimental CV results for the 3-MPA on AuNP electrode.