• Title/Summary/Keyword: 반투명도

Search Result 24, Processing Time 0.037 seconds

Difference of Translucency according to Drying Time after Staining of Dental Zirconia (치과용 지르코니아 착색 후 건조시간에 따른 반투명도의 차이)

  • Lee, Joo-Hee;Park, Jin-Young;Kim, Dong-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.4
    • /
    • pp.124-130
    • /
    • 2021
  • Dental prosthesis translucency importantly contributes to aesthetic outcomes. The purpose of this study was to investigate the effect of drying time and zirconia coloring agent type on translucency. For the experiment, 90 circular specimens were fabricated for each zirconia block. Then, zirconia specimens were treated with a coloring agent for 180 seconds and dried for 0 seconds (undried), 30 seconds (intermediate dry), or 30 minutes (complete dry). Then, a specimen was placed on a black standard tile or a white standard tile, and using a standard D65 light source reflected was measured using the light removal method. A total of three repeated measurements were obtained per specimen. One-way ANOVA was used to compare and analyze the relationship between zirconia translucency and drying time. Zirconia and coloring liquid types were significantly associated with translucency (P < 0.001). Although no significant difference was observed with respect to drying time (P > 0.922), zirconia in the completely dried (30 minutes) state was more translucent.

Per-Object Transparency in Visualization of Segmented Volumes (분할된 볼륨의 가시화에서 객체당 투명도)

  • Jeong Dongkyun;Shin Yeong Gil;Lee Cheol-Hi
    • Journal of Korea Multimedia Society
    • /
    • v.8 no.9
    • /
    • pp.1239-1247
    • /
    • 2005
  • Basically, objects are discriminated by transfer functions in volume rendering . However, in some cases objects cannot be discriminated only with transfer functions. In these cases, objects are pre-segmented with other methods, and visualized based on the segmentation information. In this paper we present a way of assigning per-object transparency in visualization of segmented volumes. Semi-transparent rendering is used to effectively give context information about the observed object. Per-object transparency can be used as a very effective visualization tool especially when it is difficult to adjust transfer functions to make the object semi-transparent. We present several interpretations of the meaning of per-object transparency, and corresponding variations of the algorithm. We show that efficient implementations for interactive use are possible, by presenting an implementation using general graphics hardware.

  • PDF

Fracture Strength and Translucency of CAD/CAM Zirconia Crown for Primary Anterior Tooth (CAD/CAM으로 제작한 유전치 지르코니아 전장관의 두께에 따른 파절강도와 반투명도 비교)

  • Ong, Seung-Hwan;Kim, Jongsoo;Kim, Jongbin;Shin, Jisun;Yoo, Seunghoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.47 no.2
    • /
    • pp.205-212
    • /
    • 2020
  • The purpose of this study is to evaluate the validity of primary anterior zirconia crown made with Computer Aided Design/Computer Aided Manufacturing (CAD/CAM) technology by analyzing fracture strength and translucency parameter. Zirconia crown was designed with CAD software, using 3D scanned data of #61 tooth model. Crown fabrication was performed with CAM machine using zirconia block. Zirconia crowns were divided into 3 groups according to thickness(0.3, 0.5, and 0.7 mm), and fracture strength was compared with 1.0 mm thickness of resin strip crown. The compressive force was applied with universal testing machine at 30° along the incisal edge at increments of 1 mm/min. For translucency evaluation, 0.3, 0.5, and 0.7 mm thickness of zirconia specimens were fabricated and translucency was measured with spectrophotometer. Among zirconia groups, there was a significant increase in fracture strength as thickness increased (p < 0.05). The fracture strength of zirconia crown was significantly higher than resin strip crown in all groups (p < 0.05). Translucency parameter was highest in 0.3 mm group, and significantly decreased as thickness increased to 0.5 and 0.7 mm (p < 0.05). Thin primary anterior zirconia crown can be designed and fabricated according to individual needs by using CAD/CAM. Restoration with thin crown would reduce the amount of tooth reduction, risk of pulp exposure, and make more esthetic restoration possible.

Review on factors affecting the optical properties of dental zirconia (치과용 지르코니아의 광학적 성질에 영향을 미치는 요소에 대한 문헌고찰)

  • Park, Chan-Ho;Ko, Kyung-Ho;Park, Chan-Jin;Cho, Lee-Ra;Huh, Yoon-Hyuk
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.37 no.4
    • /
    • pp.177-185
    • /
    • 2021
  • Clinical applications of translucent zirconia as well as traditional zirconia (3 mol% yttria stabilized tetragonal zirconia polycrystal, 3Y-TZP) are increasing. For this reason, studies on factors affecting the optical properties of dental zirconia have been continuously reported. The optical effect of dental zirconia may vary depending on the yttria content, the thickness of the prosthesis, the sintering process, polishing, glazing and cementation in laboratory and clinical procedures. Increasing the yttria concentration can reduce the masking effect. Translucency decreases as the thickness of the restoration increases, but the required thickness may vary depending on the properties of the zirconia block. The high-speed sintering method can shorten the manufacturing time, but in some cases, the translucency of the prosthesis may decrease. In addition, the optical properties can be affected by the surface roughness of zirconia and the polishing process. The use of an appropriate colored cement can help with the masking effect of zirconia and can be useful for color matching for more esthetic results.

진공조건에 따른 Parylene 코팅박막의 투명도 평가

  • Lee, Su-Min;Jo, Gyu-Seok;Lee, Ji-Yun;Lee, Yun-Jin;Heo, Seung-Uk;Nam, Sang-Hui
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.297-297
    • /
    • 2012
  • Parylene 코팅은 다결정인 고분자 유기물에 열을 가하여 기화시켜 진공상태에서 피사체를 코팅하는 것으로 마이크로 두께 단위의 유전체 증착하는 것이다. Parylene 코팅은 주로 Display를 비롯한 태양전지, 반도체 등에서 다양한 산업분야에서 이용되며, 이 때 외부로부터 침투하는 수분을 방지하고, 전기적 절연 및 불순물로부터 피사체를 보호하여 기계적인 안정성을 목적으로 사용된다. Display와 태양전지는 빛을 이용하는 분야로써 Parylene을 투과하여 들어오는 빛의 전달효율에 따른 영향이 크게 고려되어진다. 빛의 전달효율을 높이기 위해서는 Parylene의 높은 투명도가 중요한 요소로 작용한다. 본 연구에서는 Parylene 코팅 박막의 투명도 상승을 위해 증착 시 다양한 진공조건으로 실험을 진행하였다. Parylene 코팅 시, 진공도에 따른 투명도를 평가하기 위해 Substrate로는(100%)투과율을 가지는 재질의 glass를 이용하였다. Parylene 종류로는 반도체분야에 주로 이용되는 C-type의 Parylene Polymer 사용하였다. 증착 조건으로는 $7{\sim}8{\times}10^{-2}$ Torr, $4{\sim}6{\times}10^{-2}$ Torr, $2{\sim}3{\times}10^{-2}$ Torr의 각각 다른 진공 조건에서 120분간 증착시켜 Parylene 코팅막을 형성하였다. 또한 높은 투습방지력을 가짐과 동시에 고투명도 유지에 대해 신뢰성평가를 하기위해 각 조건별로 1회, 3회, 5회 반복 증착하였다. 제작된 각 시편의 투명도 측정을 위해 광도계(DX-100, TAKEMURA)를 이용하여 빛의 투과율을 관찰하였다. 그 결과 진공도 $2{\sim}3{\times}10^{-2}$ Torr, $4{\sim}6{\times}10^{-2}$ Torr, $7{\sim}8{\times}10^{-2}$ Torr순의 시편이 높은 투과율을 나타내었으며, 그 중 $2{\sim}3{\times}10^{-2}$ Torr의 1회 증착 한 시편이(97%)로 가장 높은 투과율을 나타내었다. 반대로 $7{\sim}8{\times}10^{-2}$ Torr의 5회 증착 한 시편이(78%)로 가장 낮은 투과율을 보였다. 따라서 진공도가 높을수록 투명도가 상승하며, 증착횟수가 늘어날수록 투명도가 감소하는 것을 알 수 있었다. 본 연구의 결과로 Parylene 코팅의 진공도에 따른 투명도를 평가함으로써 Parylene 코팅 증착조건 최적화를 위한 기초자료로 이용될 것이라 사료된다. 또한 후속 연구로써 substrate의 온도조절과 시료량의 조절이 이루어진다면 좀 더 효율적으로 최적화된 박막형성이 가능할 것이라 판단된다.

  • PDF

Influencing factors on the final color of laminate veneer restorations with various IPS Empress Esthetic$^{(R)}$ ingots (다양한 IPS Empress Esthetic$^{(R)}$ ingot으로 제작한 laminate veneer의 최종 색조에 대한 영향)

  • Yang, Mi-Seon;Kim, Seok-Gyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.4
    • /
    • pp.308-315
    • /
    • 2011
  • Purpose: The purpose of this study was to colorimetrically evaluate the masking effect of different opacity of ingots on the final shade of IPS Empress Esthetic$^{(R)}$ laminate veneer restorations using the CIE $L^*a^*b^*$ system. Materials and methods: Six porcelain disks of IPS Empress Esthetic$^{(R)}$ system (translucency: E 01, E 03, E 0C-1, E TC-1, E TC-2, E TC-3) were fabricated with 7 mm in diameter and 0.6 mm in thickness. Six extracted human incisors (shade: A1, A3, A4, B2, B3, C3) were used as the abutment specimens. The incisors were prepared using a diamond wheel and made with a flat labial surface on the middle 1/3. For each combination of different shades of abutments and copings, the change in color was measured with a colorimeter. CIE $L^*a^*b^*$ coordinates were recorded for each specimen. Color differences (${\Delta}E$) were calculated. Descriptive statistical analysis was done. Results: ${\Delta}E$ values were significantly affected by coping translucency and abutment shade (P<.05). The color differences (${\Delta}E$) of laminate veneers among abutments with A3, B3, C3, and A4 shade were mostly below 2.7 which was within the clinically acceptable range, while color differences between A4 and B2, A3 and B2, and A1 and A4 showed more than 2.7. Conclusion: The final color of IPS Empress Esthetic$^{(R)}$ laminate veneers were significantly influenced by translucency of the coping and shade of abutment teeth. The large value difference of abutment teeth limited the masking ability by laminate veneers.

Effect of translucency on CAD/CAM ceramic according to different core/veneer thickness (캐드캠 세라믹의 코어와 베니어의 서로 다른 두께가 반투명도에 미치는 영향)

  • Kang, Wol;Kim, Ji-Hwan
    • Journal of Korean society of Dental Hygiene
    • /
    • v.18 no.6
    • /
    • pp.1037-1045
    • /
    • 2018
  • Objectives: The purpose of this study was to evaluation the effect of translucency on CAD/CAM ceramic according to different core/veneer thicknesses. Methods: A total of 42 samples from 2 groups of 7 ceramic cores, each with 3 thickness values (0.8, 1.0, 1.2 mm) were manufactured. The veneers were also manufactured in 3 thicknesses (0.3, 0.5, 0.7 mm). The group names were based on the name of the ceramic core (IPS e.Max CAD; LD, and IPS Empress CAD; LR). The associated number was determined by the combined thickness of the core and veneer: 1 = (0.8 + 0.7); 2 = (1.0 + 0.5); 3 = (1.2 + 0.3). The translucency was measured using a spectrophotometer and defined via the contrast ratio (CR) and translucency parameter (TP). Two-way ANOVA was performed to compare the 2 groups (material and thickness). Results: As the core thickness increased, the TP value also increased, and the CR value (for LR group) decreased. The results of 2-way ANOVA demonstrated that the thicknesses of different core/veneer combinations significantly affected the translucency (p<0.05). Conclusions: The different core and veneer thicknesses affected the translucency of CAD/CAM ceramic.

Translucency of ceramic veneers on glazing effect (세라믹 비니어의 글레이징에 따른 반투명도 변화)

  • Kim, Sung-Joon;Kahm, Se Hoon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.2
    • /
    • pp.138-143
    • /
    • 2015
  • Purpose: The aim of this study was to compare the translucency of two different laminate ceramic veneers with and without glazing. Materials and methods: Ten millimeter side square-shaped specimens in 0.3 mm and 0.6 mm thick were fabricated for the following materials with and without glazing (n=80): A1 shade IPS e.maxPress (IEM) and Styleveneers (STV). The color coordinates (CIE $L^*a^*b^*$) of the specimens were measured with a colorimeter. The Translucency parameter (TP) was calculated from the color difference of the material on a black versus a white background. For comparisons between materials and between the 'not glazed' and 'glazed' groups, unpaired t-test was used to analyze the data (P=.05). Results: The TP ($Mean{\pm}SD$) of 'not-glazed' and 'glazed' group of IEM specimens at 0.3 mm thickness were $45.99{\pm}3.00$ and $49.53{\pm}2.28$ and the TP at 0.6 mm thickness were $32.82{\pm}2.59$ and $43.02{\pm}0.98$, respectively. Likewise, the TP of 'not-glazed' and 'glazed' group of STV specimens at 0.3 mm thickness were $47.03{\pm}3.65$ and $50.95{\pm}3.05$ and the TP at 0.6 mm thickness group were $34.48{\pm}1.28$ and $43.39{\pm}1.20$, respectively. As the glazing of ceramic veneer differed, the TP of each ceramic veneer showed statistically significant difference. But, the result between the products was not statistically different. Conclusion: Within the limitations of this study, we are concluded that the glazing process changed translucency of laminate ceramic veneers and the TP would not be affected by products.

Effects of Fabrication Conditions on Electro-optic Properties of UV-Cured Polymer/Liquid Crystal Composite Films (UV 경화형 고분자/액정 복합체의 제조 조건에 따른 전기광학적 특성)

  • Park, Se Kwang;Park, Lee Soon;Keum, Chang Dae;Seok, Jae Wook;Ahn, Won Sool
    • Applied Chemistry for Engineering
    • /
    • v.9 no.4
    • /
    • pp.579-584
    • /
    • 1998
  • Polymer dispersed liquid crystal(PDLC) composite films were made by polymerization induced phase separation method using UV-curing to investigate the effect of fabrication conditions, such as photoinitiator concentration, film thickness, polymerization temperature, and electric field during polymerization, etc., on the electro-optic properties. As the amount of photoinitiator increased, the driving voltage of PDLC device increased due to the increase of small-size liquid crystal phases. This was considered as the results from the increased interfacial area between liquid crystal (LC) and polymer matrix, since LC molecules at the interfacial regions were relatively difficult to response for the applied electric field. When the higher molecular weight oligomer (PTDA-1000) was used as matrix, the initial transmittance was observed to be relatively higher than that for the lower molecular weight oligomer (PTDA-250). Saturation transmittance for PTDA-1000 was observed at relatively lower voltage than that for PTDA-250, of which transmittance was not saturated even at 60 V. As polymerization temperature increased, the initial transmittance of resulting PDLC film increased due to the larger LC droplets formation and the more matched refractive index between LC and matrix than those cases for the lower polymerization temperature. Though driving voltage decreased for the thinner film, it was considered that optimum thickness of the film should be maintained to get some practical contrast, which is the ratio of off- and on-state transmittance. Furthermore, electro-optic properties such as initial transmittance, driving voltage, and response time were observed to be considerably affected by application of external field during polymerization.

  • PDF

Evaluation of water purification Ability using vegetation for water purification (수질정화를 위한 식생의 수질정화능력 평가)

  • Lee, Jong Jun;Kim, Byeong Jun;Choi, I Song;Park, Jae Ro;Oh, Jong Min
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.551-555
    • /
    • 2015
  • 본 연구는 수체 내 오염물질을 직접적으로 처리할 수 있는 친자연형 소재와 생물을 통한 처리의 다양한 기술 및 공법 중 식생을 이용한 수질의 정화효율에 대해 조사 하였다. 사용된 식생은 환경부 '하천식물자료집'을 바탕으로 수질정화능력이 있고 다년생으로 안정적인 생육특성을 갖는 식생으로 노랑꽃창포, 부들, 수크령, 질경이택사, 창포를 선정하여 약 13 L 크기의 원통형 반응조내에서 실험을 진행하였다. 선별된 식생들은 물가에 서식하는 식물로 15 cm 마사토를 식재 기반으로 하여 반침수 조건으로 실험을 진행하였다. 유입수는 경기도 용인시 기흥구에 위치한 기흥저수지 샘플과 경기도 화성시에 위치한 황구지천 샘플 혼합액 7 L를 주입하여 유입수 대비 유출수의 COD, T-N, T-P에 대한 저감 효율을 검토하였다. 노랑꽃 창포와 창포의 경우 침수된 부분에 플럭이 발생하여 투명도가 낮은 것으로 확인되었고, 수크령과 질경이택사의 경우 노랑꽃 창포와 창포에 비해 플럭의 발생은 적었지만 투명도는 비교적 높은 것으로 확인되었다. 특히 부들은 다른 식생에 비해 성장이 왕성한 것을 관찰할 수 있었으며, 수체의 탁도 또한 매우 낮아 투명한 것으로 확인되었다. 실험 종료 시점에는 창포의 경우 수체 내에서 잎 자체가 분해되어 식재기반 상부가 검정색으로 혐기화 된 것으로 나타났고, 부들의 경우 플럭이 약간 형성되었으나 투명도가 좋고 성장이 왕성한 특징을 나타내었다. 부들의 경우 COD, T-P의 평균 제거효율이 각각 47.1%, 46.0%로 조사되었고, 노랑꽃창포의 경우 T-N의 평균 제거효율이 63.9%로 선별 된 식생 중 가장 높게 조사되었다. 따라서 수질정화를 위한 공법으로는 부들과 노랑꽃창포가 적용 가능할 것으로 판단된다.

  • PDF