• Title/Summary/Keyword: 반복적 영상재구성

Search Result 81, Processing Time 0.022 seconds

Glasses Removal from Facial Images with Recursive PCA Reconstruction (반복적인 PCA 재구성을 이용한 얼굴 영상에서의 안경 제거)

  • 오유화;안상철;김형곤;김익재;이성환
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.41 no.3
    • /
    • pp.35-49
    • /
    • 2004
  • This paper proposes a new glasses removal method from color frontal facial image to generate gray glassless facial image. The proposed method is based on recursive PCA reconstruction. For the generation of glassless images, the occluded region by glasses should be found, and a good reconstructed image to compensate with should be obtained. The recursive PCA reconstruction Provides us with both of them simultaneously, and finally produces glassless facial images. This paper shows the effectiveness of the proposed method by some experimental results. We believe that this method can be applied to removing other type of occlusion than the glasses with some modification and enhancing the performance of a face recognition system.

Comparison Study on Projection and Backprojection Methods for CT Simulation (투사 및 역투사 방법에 따른 컴퓨터단층촬영 영상 비교)

  • Oh, Ohsung;Lee, Seung Wook
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.323-330
    • /
    • 2014
  • Image reconstruction is one of the most important processes in CT (Computed tomography) technology. For fast scanning and low dose to the objects, iterative reconstruction is becoming more and more important. In the implementation of iterative reconstruction, projection and backprojection processes are considered to be indispensable parts. However, many approaches for projection and backprojection may result severe image artifacts due to their discrete characteristics and affects the reconstructed image quality. Thus, new approaches for projection and backprojection are highly demanded these days. In this paper, distance-driven approach was evaluated and compared with other conventional methods. The numerical simulator was developed to make the phantoms, and projection and backprojection images were compared using these approaches. As a result, it turned out that there are less artifacts during projection and backprojection in parallel and fan beam geometry.

Quantitative evaluation of iterative reconstruction algorithm for high quality computed tomography image acquisition with low dose radiation : Comparison with filtered back projection algorithm (저선량.고화질 CT 영상 획득을 위한 반복적 재구성 기법의 정량적 평가 : 필터보정 역투영법과의 비교 분석)

  • Ha, Seongmin;Shim, Hackjoon;Chang, Hyuk-Jae;Kim, Seonkyu
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2013.06a
    • /
    • pp.274-277
    • /
    • 2013
  • CT(Computed Tomography)영상에서 선량과 화질은 중요한 요소이다. 선량은 환자에게 직접적으로 악영향을 끼치는 요소이며, 화질은 환자의 병변을 판단하는데 매우 중요하게 작용한다. 반복적 재구성 알고리즘을 이용하면 저선량 영상에서도 고화질의 영상을 얻을 수 있는지 FBP와 정량적, 정성적으로 비교하였다. 촬영 프로토콜은 관전압 80, 100, 120kVp에서 관전류를 동일하게 200mA로 촬영하여 획득하였으며, 정량적 평가를 위해 SD(Standard Deviation), SNR(Signal to Noise Ratio), MTF(Modulation Transfer Function)를 측정하여 분석하였다. 선량은 80kVp일 때 가장 낮았으며, 120kVp일 때 가장 높았다. 80kVp의 영상을 Toshiba 사(社)의 AIDR 3D(Adaptive Iterative Reduction integrated into $^{SURE}Exposure$)로 재구성하고, 120kVp의 영상에 FBP로 재구성한 다음 정량적 비교를 한 결과 AIDR 3D를 적용한 영상의 SD가 낮게 나왔으며, SNR이 높게 나타났고, MTF 곡선은 유사하게 나타났다. 그리고 FWHM(Full Width at Half Maximum) 값의 오차가 거의 없었다. 결론적으로 AIDR 3D는 저선량에서도 높은 화질을 나타냄을 확인하였다.

  • PDF

Comparison of Weight Functions in Iterative Technique for Image Reconstruction of Gamma-ray CT (감마 CT 영상재구성을 위한 반복적인 방법의 가중치 함수비교)

  • Lee, Na-Young;Jung, Sung-Hee;Kim, Jong-Bum;Kim, Jin-Sup;Kim, Jae-Ho
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2007.10c
    • /
    • pp.480-484
    • /
    • 2007
  • 일반적으로 x선 CT는 물체 투과율이 짧기 때문에 대형 산업공정 내부의 영상진단 시 대상체는 금속으로 구성되어 있으며 내부는 액체, 고체, 기체 등 고밀도 물질이 포함되어 있어 계측이 어렵다. 따라서 본 논문에서는 물체 투과율이 x선에 비해 긴 감마선을 사용하였다. 대형 산업공정 내부의 단면영상을 재구성하기 위하여 반복적인 영상재구성 방법의 가중치 함수를 비교하였다. 실험 결과를 통하여 감마 CT 영상에서 빔 통과 여부에 따른 가중치 함수보다 빔 길이나 면적에 의한 가중치 함수로 복원할 경우, 원 영상과 유사함을 확인하였다.

  • PDF

Effects of Iterative Reconstruction Algorithm, Automatic Exposure Control on Image Quality, and Radiation Dose: Phantom Experiments with Coronary CT Angiography Protocols (반복적 재구성 알고리즘과 관전류 자동 노출 조정 기법의 CT 영상 화질과 선량에 미치는 영향: 관상동맥 CT 조영 영상 프로토콜 기반의 팬텀 실험)

  • Ha, Seongmin;Jung, Sunghee;Chang, Hyuk-Jae;Park, Eun-Ah;Shim, Hackjoon
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.28-35
    • /
    • 2015
  • In this study, we investigated the effects of an iterative reconstruction algorithm and an automatic exposure control (AEC) technique on image quality and radiation dose through phantom experiments with coronary computed tomography (CT) angiography protocols. We scanned the AAPM CT performance phantom using 320 multi-detector-row CT. At the tube voltages of 80, 100, and 120 kVp, the scanning was repeated with two settings of the AEC technique, i.e., with the target standard deviations (SD) values of 33 (the higher tube current) and 44 (the lower tube current). The scanned projection data were reconstructed also in two ways, with the filtered back projection (FBP) and with the iterative reconstruction technique (AIDR-3D). The image quality was evaluated quantitatively with the noise standard deviation, modulation transfer function, and the contrast to noise ratio (CNR). More specifically, we analyzed the influences of selection of a tube voltage and a reconstruction algorithm on tube current modulation and consequently on radiation dose. Reduction of image noise by the iterative reconstruction algorithm compared with the FBP was revealed eminently, especially with the lower tube current protocols, i.e., it was decreased by 46% and 38%, when the AEC was established with the lower dose (the target SD=44) and the higher dose (the target SD=33), respectively. As a side effect of iterative reconstruction, the spatial resolution was decreased by a degree that could not mar the remarkable gains in terms of noise reduction. Consequently, if coronary CT angiogprahy is scanned and reconstructed using both the automatic exposure control and iterative reconstruction techniques, it is anticipated that, in comparison with a conventional acquisition method, image noise can be reduced significantly with slight decrease in spatial resolution, implying clinical advantages of radiation dose reduction, still being faithful to the ALARA principle.

Iterative Data Completion for Limited Angle Tomography using Filtered Backprojection (각도 제한 단층영상재구성을 위한 여현 역투사 기반 반복적 데이터 완결 기법)

  • Lee, Nam-Yong
    • Journal of Korea Multimedia Society
    • /
    • v.12 no.3
    • /
    • pp.372-382
    • /
    • 2009
  • When the range of projection angles is limited, tomographic reconstruction suffers from artifacts caused by incomplete data. One can consider a data completion technique, which estimates projection data at unobserved angles using a prior knowledge or mathematical exploration, but the result is often not improved; the improvement by the data completion often undermined by the artifacts by inaccurate estimation, In this paper, we propose an iterative method, which computes projection data at unobserved angles by using the current estimate on the image, links the computed projection data to the observed ones by using the consistence condition of Radon transform, and reconstruct the next estimate on the image by filtered backprojection. The proposed method does not require a prior knowledge on the image, and has much faster approximation rate than the expectation maximization method. The performance of the proposed method was tested through several simulation studies.

  • PDF

Evaluation of Noise Level and Blind Quality in CT Images using Advanced Modeled Iterative Reconstruction (ADMIRE) (고급 모델 반복 재구성법 (ADMIRE)을 사용한 CT 영상에서의 노이즈 레벨 및 블라인드 화질 평가)

  • Shim, Jina;Kang, Seong-Hyeon;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.203-209
    • /
    • 2022
  • One of the typical methods for lowering radiation dose while maintaining image quality of computed tomography (CT) is the use of model-based iterative reconstruction (MBIR). This study is to evaluate the image quality by adjusting the strength of the advanced modeled iterative reconstruction (ADMIRE), which is well known as a representative model of MBIR. The study was conducted using phantom, and CT images were obtained while adjusting the strength of ADMIRE in units of 1 to 5. Quantitative evaluation includes noise levels using coefficient of variation (COV) and contrast to noise ratio (CNR), as well as natural image quality evaluation (NIQE) and blind/referenceless image spatial quality evaluator (BRISQUE). As a result, in both noise level and blind quality evaluation results, the higher the strength of ADMIRE, the better the results were derived. In particular, it was confirmed that COV and CNR were improved 1.89 and 1.75 times at ADMIRE 5 compared to ADMIRE 1, respectively, and NIQE and BRISQUE were proved to be improved 1.35 and 1.22 times at ADMIRE 5 compared to ADMIRE 1, respectively. In conclusion, this study was proved that the reconstruction strength of ADMIRE had a great influence on the noise level and overall image quality evaluation of CT images.

A Study on the Parallel Processing Architecture for the Real Time Image Reconstruction of X-ray CT (X-ray CT의 실시간 영상재구성을 위한 병렬처리 구조에 관한 연구)

  • Jin, Seung-Oh;Heo, Chang-Won;Huh, Young
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3153-3155
    • /
    • 1999
  • 최근 수년간 의료영상분야는 국내외적으로 급격한 발전을 거듭하고 있다. 특히 자기공명영상장치 (Magnetic Resonance Imaging), X-ray CT(Computed Tomography)와 단층촬영장치는 인체내부를 비침습적(non-invasive)으로 영상화함으로써 해부학적인 질병진단에 많은 장점을 가지고 있다. 이와같은 단층영상 재구성에는 역매트릭스법(matrix inversion). 반복재구성법(interative method), 역투영 법(back-projection), 2차원 Fourier 변환법(2D FFT), 중첩재구성법(Filtered back-projection) 등의 다양한 알고리즘을 사용하고 있다. 본 연구에서는 X-ray CT에서의 단층영상재구성 기법 중 널리 사용되고 있는 Filtered Back Projection 기법의 연산순서도와 연산량을 분석하고 이를 시뮬레이션을 통하여 확인하고 실시간 영상재구성을 위하여 범용 Digital Signal Processor의 병렬처리시스템 구성에 기반된 최적 Architecture를 선정하고자 한다.

  • PDF

Efficient Determination of Iteration Number for Algebraic Reconstruction Technique in CT (CT의 대수적재구성기법에서 효율적인 반복 횟수 결정)

  • Joon-Min, Gil;Kwon Su, Chon
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.141-148
    • /
    • 2023
  • The algebraic reconstruction technique is one of the reconstruction methods in CT and shows good image quality against noise-dominant conditions. The number of iteration is one of the key factors determining the execution time for the algebraic reconstruction technique. However, there are some rules for determining the number of iterations that result in more than a few hundred iterations. Thus, the rules are difficult to apply in practice. In this study, we proposed a method to determine the number of iterations for practical applications. The reconstructed image quality shows slow convergence as the number of iterations increases. Image quality 𝜖 < 0.001 was used to determine the optimal number of iteration. The Shepp-Logan head phantom was used to obtain noise-free projection and projections with noise for 360, 720, and 1440 views were obtained using Geant4 Monte Carlo simulation that has the same geometry dimension as a clinic CT system. Images reconstructed by around 10 iterations within the stop condition showed good quality. The method for determining the iteration number is an efficient way of replacing the best image-quality-based method, which brings over a few hundred iterations.

Regularized Adaptive High-Resolution Image Reconstruction (부정확한 부화소 단위의 위치 추정 오류에 적응적인 정규화된 고해상도 영상 재구성 연구)

  • Byun, Min;Lee, Eun-Sil;Kang, Moon-Gil
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.49-55
    • /
    • 2002
  • 기존의 영상 획득 시스템들이 어느 정도의 엘리어싱을 허용하도록 제작되어왔음에도 불구하고, 고해상도 영상에 대한 요구는 점점 더 증가하고 있다. 본 논문에서는 부정확한 부화소 단위의 위치추정 오류를 고려한 고해상도 재구성 알고리즘을 제안한다. 부정확한 부화소 위치 추정 오류로 인해 생기는 불량위치문제(ill-posedness)를 해결하기 위해 정규화된 반복 연산법을 적용하였다. 특히 여러장의 저해상도 영상들을 개별적으로 고려하기에 적합한 다중채널 영상 재구성 방법을 도입하였다. 각 저해상도 영상에서 발생하는 움직임 추정오류는 서로 다른 경향성을 나타내므로, 정규화 파라미터들은 각 채널에 맞게 결정되어야 한다. 이를 위채 정규화 파라미터들을 자동으로 결정하는 방법을 제안한다. 제안한 알고리즘은 움직임 추정 오류에 매우 안정하며, 원 영상과 잡음에 대한 사전정보를 필요로 하지 않는다. 또한 주관적인 측면과 객관적인 측면에서 모두 우수한 결과를 실험적으로 보인다.

  • PDF