Influence of Implant Fixture-Abutment Connection and Abutment Design on Mechanical Strength (임플란트 고정체-지대주 연결부 및 지대주 디자인이 기계적 강도에 미치는 영향)

  • Chun, Mi-Hyun;Jeong, Chang-Mo;Jeon, Young-Chan;Eom, Tae-Gwan;Yoon, Ji-Hoon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.3
    • /
    • pp.269-281
    • /
    • 2008
  • Fatigue or overload can result in mechanical problems of implant components. The mechanical strength in the implant system is dependent on several factors, such as screw and fixture diameters, material, and design of the fixture-abutment connection and abutment. In these factors, the last rules the strength and stability of the fixture-abutment assembly. There have been some previous reports on the mechanical strength of the fixture-abutment assembly with the compressive bending test or short-term cyclic loading test. However, it is restrictive to predict the long-term stability of the implant system with them. The purpose of this study was to evaluate the influence of the design of the fixture-abutment connection and abutment on the mechanical strength and failure mode by conducting the endurance limit test as well as the compressive bending strength test. Tests were performed according to a specified test(ISO/FDIS 14801) in 4 fixture-abutment assemblies of the Osstem implant system: an external butt joint with Cemented abutment (group BJT), an external butt joint with Safe abutment (group BJS), an internal conical joint with Solid abutment (group CJO), and an internal conical joint with ComOcta abutment (group CJT). The following conclusions were drawn within the limitation of this study. Compressive bending strengths were decreased in order of group BJS(1392.0N), group CJO(1261.8N), group BJT(1153.2N), and group CJT(1110.2N). There were no significant differences in compressive bending strengths between group BJT and group CJT(P>.05). Endurance limits were decreased in order of group CJO(600N), group CJT(453N), group BJS(360N), and group BJT(300N). 3. Compressive bending strengths were influenced by the connection and abutment design of the implant system, however endurance limits were affected more considerably by the connection design.

Mechanical strength of Zirconia Abutment in Implant Restoration (지르코니아 임플란트 지대주의 기계적 강도에 관한 연구)

  • Shin, Sung-ae;Kim, Chang-Seop;Cho, Wook;Jeong, Chang-Mo;Jeon, Young-Chan;Yun, Ji-Hoon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.4
    • /
    • pp.349-360
    • /
    • 2009
  • Purpose: As the esthetic demands of dental implant patients are increased, the demands of zirconia as implant abutment material are also increased. It has non-metalic color, good biocompatibility, high strength and high toughness. Even thought the advatage of zirconia abutment, there are a few studies about mechanical properties of zirconia abutment. This study evaluated the mecanical strength with compressive bending strength and endurance limit of implant-zirconia abutment assembly. Materials and Methods: Static and cyclic loading of implant-Zirconia abutment assembly were simulated under worst case condition according to ISO. Test groups were implants of external butt joint with straight regular diameter and angled regular diameter zirconia abutment, implant of external butt joint with narrow straight diameter zirconia abutment and implant of internal conical joint with straight narrow diameter zirconia abutment. All test group were evaluated the mecanical strength with compressive bending strength and endurance limit. After fatique testing, fracture surface were examined by SEM. Results: The compressive bending strengths exceed 927N. Regular diameter zirconia abutment were stronger than narrow diameter zirconia abutment(P<.05). The endurance limits ranged from 503N to 868N. Conclusion: Within the limitation of this study, zirconia implant abutment exceeded the estabilished values for maximum incisal biting forces reported in the literature.

유연성 소자 적용을 위한 $SiO_x$ 보호막의 특성 평가

  • Jeong, Yu-Jeong;Jeong, Jae-Hye;Yun, Jeong-Heum;Lee, Seong-Hun;Lee, Geon-Hwan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.452-452
    • /
    • 2010
  • 차세대 디스플레이로서 주목 받고 있는 유연성 정보표시 소자 개발에 대한 요구도가 날로 증대되고 있다. 유연성 정보표시 소자로서 플라스틱 기반 유연성 소자가 특히 주목 받고 있으나, 이의 실용화를 위해서는 플라스틱 기판에 적용 가능한 보호막 형성 기술 개발이 선행되어야 한다. 플라스틱 필름의 경우 높은 산소 및 수분 투과율 때문에 유연성 디스플레이의 응용에 걸림돌이 되고 있다. 플라스틱 기반 유연성 소자의 장수명화를 위해서는 수분과 산소의 투과를 방지하는 passivation layer 형성 기술이 필수적으로 요구된다. 본 연구에서는, polyethylene terephethalate (PET) 기판상에 증착된 $SiO_x$ 보호막의 합성에 있어서 중간층 유무에 따른 투습특성의 변화를 살펴보았다. 기화된 HMDSO (Hexamethyldisiloxane)와 Ar 및 $O_2$ 혼합기체를 이용하여 PECVD 방법으로 $SiO_x$ 박막을 합성하였다. 15 nm 두께의 $Al_2O_3$를 중간층으로 사용하여 중간층 유무에 따른 초기성장 거동 변화가 $SiO_x$ 박막의 투습 특성에 미치는 영향을 조사하였다. $SiO_x$ 박막 구조와 화학적 조성은 각각 FE-SEM과 FT-IR을 이용하여 분석하였으며, AFM을 이용하여 $SiO_x$ 박막 표면 미세 형상을 관찰하였다. 투습률은 MOCON사(社)의 Permatran-W 3/33 MA을 이용하여 측정하였다. 그리고 반복 굽힘 시험기를 이용하여 $SiO_x$ 보호막의 동적 투습 특성을 조사하였다. $Al_2O_3$ 중간층 유무에 따라 $SiO_x$ 박막의 투습률 (WVTR; water vapor transmission rate)은 ${\sim}10^{-1}g/m^2/day$(300 nm-thick $SiO_x$/PET)에서 ${\sim}5{\times}10^{-3}g/m^2/day$(300 nm-thick $SiO_x$/15 nm-thick $Al_2O_3$/PET)으로 변화하였다. 300 nm-thick $SiO_x$/15 nm-thick $Al_2O_3$/PET 시편의 경우 곡지름 50 mm에서 1,000회 반복 굽힘 후에도 투습률 변화를 보이지 않았다. 이와 같은 $SiO_x$ 박막의 투습 특성 변화는 $Al_2O_3$ 중간층 유무에 따른 초기 성장 거동의 변화로 해석된다. FE-SEM 및 AFM 표면 미세 구조 관찰을 통한 초기 성장 거동 변화 조사 결과, $Al_2O_3$ 중간층 없이 PET 기판위에 $SiO_x$ 박막 증착한 경우 3 차원 성장을 하는 반면, PET기판위에 $Al_2O_3$ 중간층 형성 후 $SiO_x$ 박막 증착하는 경우 2 차원 성장을 하게 됨을 관찰하였다. 따라서 본 연구를 통하여, 플라스틱 기반 유연성 표시 소자에 적용하기 위한 $SiO_x$ 보호막 합성 에 있어서 초기 성장 거동의 변화가 투습 특성에 민감한 영향을 미침을 알 수 있었다.

  • PDF

Room-temperature Bonding and Mechanical Characterization of Polymer Substrates using Microwave Heating of Carbon Nanotubes (CNT 마이크로파 가열을 이용한 고분자 기판의 상온 접합 및 기계적 특성평가)

  • Sohn, Minjeong;Kim, Min-Su;Ju, Byeong-Kwon;Lee, Tae-Ik
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.28 no.2
    • /
    • pp.89-94
    • /
    • 2021
  • The mechanical reliability of flexible devices has become a major concern on their commercialization, where the importance of reliable bonding is highlighted. In terms of component materials' properties, it is important to consider thermal damage of polymer substrates that occupy large area of the flexible device. Therefore, room temperature bonding process is highly advantageous for implementing flexible device assemblies with mechanical reliability. Conventional epoxy resins for the bonding still require curing at high temperatures. Even after the curing procedure, the bonding joint loses flexibility and exhibits poor fatigue durability. To solve this problems, low-temperature and adhesive-free bonding are required. In this work, we develop a room temperature bonding process for polymer substrates using carbon nanotube heated by microwave irradiations. After depositing multiple-wall carbon nanotubes (MWNTs) on PET polymer substrates, they are heated locally with by microwave while the entire bonding specimen maintains room temperature and the heating induces mechanical entanglement of CNT-PET. The room temperature bonding was conducted for a PET/CNT/PET specimen at 600 watt of microwave power for 10 seconds. Thickness of the CNT bonding joint was very thin that it obtains flexibility as well. In order to evaluate the mechanical reliability of the joint specimen, we performed lap shear test, three-point bending test, and dynamic bending test, and confirmed excellent joint strength, flexibility, and bending durability from each test.

Reliability of Cu Interconnect under Compressive Fatigue Deformation Varying Interfacial Adhesion Treatment (유연소자용 기판과의 접착 특성에 따른 구리 배선의 압축 피로 거동 및 신뢰성)

  • Min Ju Kim;Jeong A Heo;Jun Hyeok Hyun;So-Yeon Lee
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.30 no.4
    • /
    • pp.105-111
    • /
    • 2023
  • Electronic devices have been evolved to be mechanically flexible that can be endured repetitive deformation. This evolution emphasizes the importance of long-term reliability in metal wiring connecting electronic components, especially under bending fatigue in compressed environments. This study investigated methods to enhance adhesion between copper (Cu) and polyimide (PI) substrates, aiming to improve the reliability of copper wiring under such conditions. We applied oxygen plasma treatment and introduced a chromium (Cr) adhesion layer to the polyimide substrate. Our findings revealed that these adhesion enhancement methods significantly affect compression fatigue behavior. Notably, the chromium adhesion layer, while showing weaker fatigue characteristics at 1.5% strain, demonstrated superior performance at 2.0% strain with no delamination, outperforming other methods. These results offer valuable insights for improving the reliability of flexible electronic devices, including reducing crack occurrence and enhancing fatigue resistance in their typical usage environments.

A Modification in the Analysis of the Growth Rate of Short Fatigue Cracks in S45C Carbon Steel under Reversed Loading (반복하중조건 하에서의 S45C 탄소강에 대한 미소피로균열 성장속도 해석의 수정)

  • McEvily,A.J.
    • Journal of Welding and Joining
    • /
    • v.13 no.2
    • /
    • pp.96-105
    • /
    • 1995
  • A modified method for the analysis of short fatigue crack growth has been presented, and calculations based upon the modified method are compared with experimental results for S45C carbon steel. It is also shown that the modified method is in good agreement with experimental data. The proposed equation for the fatigue crack growth rates includes a material constant which relates the threshold level to the endurance limit, a correction for elastic-plastic behaviour and a means for dealing with the effects of crack closure. In this study one of the modifications is to substitute the Forman' s elastic expression of the stress intensity factor range into the geometrical factor The other is a consideration of the bending effect which is developed from the moment caused by the eccentric cross sectional geometry as the crack grows. Thus, this method is useful for residual life prediction of the mechanical structures as well as the welding structures.

  • PDF

A Study of Fatigue Lifetime Evaluation on the Interconnect of Semiconductor Pressure Sensor According to the Various Materials (재료에 따른 반도체 압력 센서 배선의 피로 수명 평가에 관한 연구)

  • Shim Jae-Joon;Han Dong-Seop;Han Geun-Jo;Lee Sang-Suk
    • Journal of Navigation and Port Research
    • /
    • v.29 no.10 s.106
    • /
    • pp.871-876
    • /
    • 2005
  • Application of semiconductor sensors has been widely spreaded into various industries because those have several merits like easy miniaturization and batch production comparison with previous mechanical sensors. But external conditions such as thermal and repetitive load have a bad effect on sensors's lifetime. Especially, this paper was focused on fatigue life of a interconnect made by various materials. Firstly we implemented the stress analysis for interconnect under thermal load and wording pressure. And the fatigue lifetime of each material was induced by Manson & Coffin Equation using the plastic stress-strain curve obtained by the plastic-elastic Finite Element Analysis. The Fatigue lifetime in its bottom is smaller than others and bending load have not an effect on the fatigue lifetime of the interconnect but the stress distribution.

Study of the high pressure hose assemblies by accelerated life test (고압호스 조립체의 가속수명시험에 관한 연구)

  • Lee, Gi Chun;Lee, Yong Bum
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.8
    • /
    • pp.886-892
    • /
    • 2013
  • Hydraulic hose assemblies are used as piping components for construction machinery, automobile, aircraft, industrial machinery, machine tools, and machinery for ships. Then the reliability of hose assemblies is important because total hydraulic system, which used to deliver the fluid power ($P^*Q$) needed to flexibility in the piping system, is not operated if the hose assembly failed in the system. The data of the accelerated life test estimated through the shape parameter(${\beta}$) resulting of the Weibull distribution analysis. This study has tried to reduce the test time resulting from varying impulse pressure range and the flexing diameter. Accelerated life test model for the test results was adopted the GLL(generalized log linear) and the accelerated indexes are identified as 6.64 for the pressure and 4.46 for flexing radius. Also, it found that shape parameter is 6.19, scale parameter(${\eta}$) is $1.035{\times}108$, which were adopted the pressure 35 MPa and the flexing diameter R100 mm in the used condition.

Statistical Analysis for Fatigue Life Evaluation of Vehicle Muffler (자동차용 머플러의 피로수명평가를 위한 통계적 분석)

  • Choi, Ji-Hun;Lee, Yong-Jun;Yoon, Jin-Ho;Kang, Sung-Su
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.3
    • /
    • pp.365-372
    • /
    • 2013
  • In this study, a statistical method for evaluating the fatigue life of a vehicle muffler was used to obtain reliable fatigue data using a limited number of specimens. Cyclic bending tests were conducted using specimens manufactured to be exactly the same as the mufflers installed in cars that are currently in use. To estimate the fatigue life by comparing the data obtained during the fatigue tests, the most suitable probability density function for the normal, lognormal, and Weibull distributions was selected. A goodness-of-fit test was performed on the probability distributions, and then a Weibull distribution using the least square method was selected. By using the selected Weibull distribution, the probability-moment-life curves (P-M-N curve) reflecting the fatigue characteristics were suggested as the data for the reliable design of a muffler.

Effects of Hot Isostatic Pressing on the Microstructure and High-Temperature Fatigue Life of the Ni-base Superalloy IN738LC (IN738LC 초내열합금에서 미세조직과 고온 피로수명에 미치는 고온등압압축(HIP) 공정의 영향)

  • Choi, Cheol;Kim, Doo-Soo;Lee, Young-Chan;Park, Young-Kyu;Kim, Gil-Moo;Kim, Jae-Cheol
    • Korean Journal of Materials Research
    • /
    • v.10 no.2
    • /
    • pp.128-137
    • /
    • 2000
  • A study has been made to investigate the effects of hot isostatic pressing(HIPing) on the microstructure and high temperature fatigue lives of the IN738LC, Ni-base superalloy used in turbine blades, with emphasis on the elimination of casting microporosity and fatigue damage through HIP treatments. Microstructure was observed using OM, SEM and the fatigue life was investigated with rotate bending fatigue tester. The results show that the fatigue lives of properly HIP-processed specimens could be extended be extended by a factor of about sixty. In contrast, no comparable life improvement was achieved with heat treatment only. The repetitive HIP treatment was shown to be very effective as a means of rejuvenating the fatigue life of intentionally fatigue-damaged IN738LC by restoration of the initial alloy microstructure and additional removal of fine casting defects which remained in the HIP-processed material.

  • PDF