• Title/Summary/Keyword: 반복가력

Search Result 152, Processing Time 0.023 seconds

FEA of Beam-Column Connection with Bolted Web (웨브를 볼트로 접합한 보-기둥 접합부의 유한요소해석)

  • Shin, Kyung-Jae;Lim, Bo-Hyuk;Lee, Swoo-Heon;Choi, Sung-Mo
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.3
    • /
    • pp.305-316
    • /
    • 2011
  • As the building structures are higher and bigger, the high-performance steels of high strength, toughness, and low yield ratio had been required and developed. In this paper the behavior of the moment connection with bolted web and high strength steel was studied by using the finite-element analysis computer program of ABAQUS. The analysis model is based on the test results and the same cyclic load history was applied at the FE(Finite Element) model until it failed in the test. Through the FEA, several indicators hardly measured from the test were acquired. These indicators related to stress and strain were selected from three plastic rotation stages: 0.003 rad, 0.03 rad, and final failure rotation. Specifically, at the final failure stage, the strain indicators producing the full plastic behavior were suggested as a mechanical property for steel.

Structural Performance Evaluation of Seismic Wide-flanged Beam-to-Rectangular Steel Tube Column Connection Details (내진 각형강관 기둥-H형강 보 접합상세의 구조성능평가)

  • Jang, Bo-Ra;Shim, Hyun-Ju;Kim, Yong-Ick;Chung, Jin-An;Oh, Young-Suk;Kim, Sang-Seup;Choi, Byong-Jeong;Lee, Eun-Taik
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.4
    • /
    • pp.305-312
    • /
    • 2010
  • The objective of this paper is to examine the structural performance of steel moment-resisting frames on the various connection details of Seismic Wide-flanged Beam-to-Rectangular Steel Tube Column connections. Although compared to an H-shaped steel tube, a rectangular steel tube has many advantages and is more efficient, its application is limited due to the lack of experience in using it and the connection details. Existing steel moment connections using the rectangular steel tube are mainly used through plate diaphragms. The processing of construction of the rectangular steel tube is so complicated that it is hard to apply it in the field. In this study, the structural performance and the earthquake capacity of the connection details that do not cut the rectangular steel tube column were investigated. A comparative analysis of the strength, rigidity, and energy absorption capacity of the welded connection details using an end-plate and a haunch was also performed.

Seismic Performance of RC Column-Steel Beam Connections for Large Columns (대형기둥 적용을 위한 철근콘크리트기둥-강재보 접합부의 내진성능)

  • Park, Hong Gun;Lee, Ho Jun;Kim, Chang Soo;Hwang, Hyeon Jong
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.4
    • /
    • pp.231-242
    • /
    • 2016
  • Earthquake resistance of RC column-steel beam (RCS) joints with simplified details were studied. Simplified details are necessary for large columns to improve the productivity and constructability. To strengthen the beam-column joint, the effects of transverse beams, studs, and U-cross ties were used. Four 2/3 scale interior RCS connections were tested under cyclic lateral loading. The specimens generally exhibited good deformation capacity exceeding 4.0% story drift ratio after yielding of both beam and beam-column joint. Ultimately, the specimens failed by shear mechanism of the joint panel. The test strengths were compared with the predictions of existing design methods.

Experimental Study on Ductility of RC Columns According to Configuration of Transverse Reinforcement (횡보강근 배근형상에 따른 RC 기둥의 연성에 관한 실험적 연구)

  • Kim, Min Jun;Kim, Do Jin;Kim, Sang Woo;Lee, Jung Yoon;Kim, Kil Hee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.6
    • /
    • pp.18-25
    • /
    • 2012
  • This paper estimates the ductility of reinforced concrete columns according to configurations of transverse reinforcement. A total of 8 reinforced concrete columns were cast and tested in flexure. The test variables in this study were the configurations, yield strength, and amount of transverse reinforcement. The specimens had a cross-section of $250{\times}250mm$ and had a shear span-to-depth ratio of 4.1 to induce flexural failure. In the test, cyclic lateral load was applied to the specimens with a constant axial load. The experimental result indicated that the specimens with proposed configurations of transverse reinforcement showed higher ductility and energy dissipation capacity than the specimens with rectangular tie.

Evaluation of the Seismic Performance for Domestic URM Buildings Using Nonlinear Dynamic Analysis (비선형 동적해석을 통한 국내 비보강 조적조 건축물의 내진성능 평가)

  • Baek, Eun-Rim;Kim, Jung-Hyun;Lee, Sang-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.3
    • /
    • pp.83-92
    • /
    • 2016
  • The purpose of this study is to evaluate the seismic performance of domestic unreinforced masonry(URM) buildings using nonlinear dynamic analysis. For that, the nonlinear hysteresis models suggested in the previous research were validated for the dynamic analysis. The results of the shaking table test were compared with the dynamic analysis results using the suggested nonlinear hysteresis models. As a result, the nonlinear hysteresis models were expected to be applicable to the dynamic analysis of URM buildings. Based on the models, the dynamic analysis of domestic URM buildings varying the number of stories and opening ratio was carried out. The analysis results showed that most of the domestic URM buildings were very vulnerable to design earthquake in Korea.

Displacement Ductility of Circular RC Column According to the Spacing of Spirals (나선철근 간격에 따른 원형 RC 기둥의 변위연성도)

  • Ko, Seong Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.2
    • /
    • pp.71-82
    • /
    • 2013
  • Eight small scale circular reinforced concrete columns (4.5 aspect ratio) were tested under cyclic lateral load with constant axial load. The selected test variables are longitudinal steel ratio (2.017%, 3.161%), transverse steel ratio, and axial load ratio (0, 0.07, 0.15). Volumetric ratio of spirals of all the columns is 0.335~0.894% in the plastic hinge region. It corresponds to 39.7~122.3% of the minimum requirement of confining steel by Korean Bridge Design Specifications, which represent existing columns not designed by the current seismic design specifications or designed by seismic concept. The final objectives of this study are to provide quantitative reference data and tendency for performance or damage assessment based on the performance levels such as cracking, yielding, steel fracture, etc. In this paper, describes mainly failure behavior, strength degradation behaviour, displacement ductility of circular reinforced concrete bridge columns with respect to test variables.

Seismic Performance Evaluation of Beam-Column Connection for Panel Zone Strength (패널존의 강도비에 따른 기둥-보 접합부의 내진성능 평가)

  • Kim, Sung-Young;Shin, Chang-Hoon
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.7 no.1 s.24
    • /
    • pp.11-20
    • /
    • 2007
  • The study proposes the method to cancel the scallop to avoid fracture of the circumstance of the scallop at H shape column-to-beam connection and reinforce at beam flange two faces with the cover plates and rib. A total of four specimens were tested to enhance seismic performance of building structure by reducing the frequency of stress concentration and preventing the brittle fracture of scallop. For this purpose, four full-scale test specimens were made and loaded with quasi-static reversed cyclic loading. The main analytical parameters are panel-zone-strength ratio, yield strengths, initial stiffness, total plastic rotation, contribution of each element to total plastic rotation and energy dissipation capability. For the specimens tested under repeated loading, the experimental result was satisfied with seismic performance requirement as the Special Moment Frames (SMF). The analysis results show that all of the test specimens were found to have good performance to 4% story drift and satisfied the criteria for the plastic roation capacity of SMFs that is 0.03 rad. according to the 1997 AISC seismic provision.

Experiments on the Performance of a Thin-Plate Damper Attached to a Coupling Beam (연결보에 부착된 박판형 금속 감쇠기의 성능실험)

  • Lee, Young-Wook;Chae, Ji-Yong;Park, Tae-Jun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.16 no.2
    • /
    • pp.25-33
    • /
    • 2012
  • To examine the performance of a thin plate damper attached to coupling beam of bearing wall system, 5 specimens were designed with the variable parameters of the thickness and length of a thin steel plate, which was constructed and tested with a lateral load with up to a 5% drift ratio. The result was that the total amount of the energy dissipation of the specimen with the thin plate damper was greater than that of the standard RC specimen, and the plate buckling and plastic deformation could be seen in steel plate. The shorter the length of the damper, the higher was the lateral resistant force, but there was no apparent increase in the energy dissipation. By comparison of the experiments with the elastic buckling analysis, it was shown that the buckling force from the analysis could properly estimate the maximum value of the linear elastic range.

Seismic Performance and Flexural Over-strength of Circular RC Column (원형 RC 기둥의 내진성능과 휨 초과강도)

  • Ko, Seong-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.5
    • /
    • pp.49-58
    • /
    • 2013
  • Eight small scale circular reinforced concrete columns were tested under cyclic lateral load with constant axial load. Test specimens were designed with 4.5 aspect ratio. The selected test variables are longitudinal steel ratio, transverse steel ratio, yielding strength of longitudinal steel and axial load ratio. The test results of columns with different longitudinal steel ratio, transverse steel ratio and axial load ratio showed different seismic performance such as equivalent damping ratio, residual displacement and effective stiffness. It was found that the column with low strength of longitudinal steel showed significantly reduced seismic performance, especially for equivalent damping ratio and residual displacement. The regulation of flexural over-strength is adopted by Korea Bridge Design Specifications (Limited state design, 2012). The test results are compared with nominal strength, result of nonlinear moment-curvature analysis and the design specifications such as AASHTO LRFD and Korea Bridge Design Specifications (Limited state design).

Limit State Assessment of SCH80 3-inch Steel Pipe Elbows Using Moment-Deformation Angle Relationship (모멘트-변형각의 관계를 이용한 SCH80 3인치 강재배관엘보의 한계상태 평가)

  • Kim, Sung-Wan;Yun, Da-Woon;Cheung, Jin-Hwan;Kim, Seong-Do
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.3
    • /
    • pp.122-129
    • /
    • 2020
  • To conduct probabilistic seismic fragility analysis for nuclear power plants, it is very important to define the failure modes and criteria that can represent actual serious accidents. The seismic design criteria for piping systems, however, cannot fully reflect serious accidents because they are based on plastic collapse and cannot express leakage, which is the actual limit state. Therefore, it is necessary to clearly define the limit state for reliable probabilistic seismic fragility analysis. Therefore, in this study, the limit state of the SCH80 3-inch steel pipe elbow, the vulnerable part of piping systems, was defined as leakage, and the in-plane cyclic loading test was conducted. Moreover, an attempt was made to quantify the failure criteria for the steel pipe elbow using the damage index, which was based on the dissipated energy that used the moment-deformation angle relationship.