• Title/Summary/Keyword: 바람 하중

Search Result 186, Processing Time 0.023 seconds

The Analysis of the Effect of .Wind Load on the Structural Stability of an Articulation type Container Crane (풍하중이 관절형 붐을 가진 컨테이너 크레인의 구조 안정성에 미치는 영향 분석)

  • Lee Jung-Myung;Lee Seong-Wook;Han Dong-Seop;Han Geun-Jo
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2005.10a
    • /
    • pp.235-240
    • /
    • 2005
  • Articulation type container cranes are the boom forms an inverted L shape when raise. The inner boom section is nearly vertical when raise and the outer boom section is nearly horizontal. Articulation type container cranes were developed as a lower height crane to meet aircraft clearance requirements. Because the height of an Articulation type container crane is about 70m, the crane is subjected to the effect of Wind load. Therefore, the problem on the effect of Wind load is receiving carefully study. The researches for the effect of wind load on the structural stability of a conventional container crane are conducted. In this study, we carried out the investigation for an articulation type container crane. When a wind load is applied to a container crane, we analyzed the reaction force distribution at each supporting point of a crane with respect to a wind load direction and the effect of the change of the machinery house location on the structural stability rf a crane by carrying out Finite Element Analysis.

  • PDF

Dynamic Responses of Offshore Meteorological Tower Under Wind and Wave (바람과 파랑을 받는 해상 풍력 기상탑의 동적 응답)

  • Kwon, Soon-Duck
    • Journal of the wind engineering institute of Korea
    • /
    • v.22 no.4
    • /
    • pp.171-177
    • /
    • 2018
  • In order to investigate the cause of damage of the offshore meteorological tower, the measured wind speed data were analyzed, the dynamic displacement due to fluctuating wind load and wave load was calculated, and the fatigue was examined for vortex-induced vibration. It was confirmed from the results that the vibration lasting for four hours occurred in the meteorological tower when the maximum wind speeds for 10 minutes were compared for both the vane anemometer and ultrasonic anemometer. The effect of the gust wind on the dynamic response of the meteorological tower was greater than the wave. However, the combined forces acting on the meteorological tower was much lower than the design force even though the wind and wave loads were simultaneously applied. The vortex-induced vibration seemed to be cause of the fatigue failure in the connecting bolts. The destruction of the offshore meteorological tower was considered to be a vortex-induced vibration, not a fluctuating fluid flows.

Theoretical Models for Predicting Racking Resistance of Shear Walls (전단벽의 전단성능 예측 모형)

  • Jang, Sang Sik
    • Journal of the Korean Wood Science and Technology
    • /
    • v.30 no.4
    • /
    • pp.96-105
    • /
    • 2002
  • Shear wall is the most important component resisting lateral loads imposed to a building by wind or earthquake. In shear walls, lateral load applied to framing is transmitted to sheathing panel through nailed joints between sheathing and framing so that the load is resisted by in-plane shear strength of sheathing. Therefore, nailed joints are the most basic and important component in the viewpoint of stiffness and strength of shear walls. In this study, stiffness and strength of single nailed joint were measured by single shear tests of nailed joints and used as input for theoretical models developed to estimate racking behavior of shear walls. And shear walls were tested to check the accuracy of theoretical models estimating racking resistance of shear walls. Stiffness of nailed joint was affected by grain direction of stud but direction of sheathing panel had little effect. Behavior of nailed joint and shear walls under lateral loads could be represented by three lines. Theoretical model II was more accurate than theoretical model I in estimating racking behavior of shear wall under loads.

Comparative Analysis on the Design Conditions for Offshore Wind Power Structures in the Coastal Sea of Korea (한국 연안 해상풍력 구조물의 설계조건 비교분석)

  • Ko, Dong Hui;Jeong, Shin Taek;Cho, Hongyeon;Kang, Keum Seok
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.26 no.1
    • /
    • pp.25-32
    • /
    • 2014
  • Offshore wind power structures are subject to coastal hydrodynamic loading such as wind and wave loads. A considerable number of turbines have been installed in Europe, but so far none in Korea. Interest in offshore wind energy is growing in Korea, and it is expected that projects will reach the design stage in the near future. This paper discusses the level of structural reliability implied by the design rules of ABS(2010, 2013) and IEC(2009). Metocean conditions in 4 Korean seas(Gunsan, HeMOSU 1, Mokpo, Jeju) were used in the calibrations to calculate the aerodynamic and hydrodynamic loads as well as the structural responses of the typical designs of offshore wind turbines. Due to the higher variability of the wind and wave climate in hurricane-prone areas, applying IEC strength design criteria in combination with Korea west sea conditions could result in a design with much lower reliability index than what is anticipated from a design in European waters. To achieve the same level of safety as those in European waters, application of ABS 100 year design standards are recommended. Level-1 reliability-based design suitable for the Korean sea state conditions should be introduced because the IEC standards does not consider the typhoon effects in depth and the ABS standards is a WSD design method. In addition, the design equation should be established based on the statistical characteristics of the wind and wave loads of the Korean sea areas.

Seismic Response of Spatial Structure Subjected to Multi-Support Earthquake Load (다중지점 지진하중을 고려한 대공간구조물의 지진응답 분석)

  • Kim, Gee Cheol;Kang, Joo Won
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.4
    • /
    • pp.399-407
    • /
    • 2013
  • Spatial structures have the different dynamic characteristics from general rahmen structures. Therefore, it is necessary to accurately analyze dynamic characteristics and seismic response for seismic design of spatial structure. Keel arch structure is used as an example structure because it has primary characteristics of spatial structures. In case of spatial structures with different ground condition and time lag, multiple support excitation may be subjected to supports of a keel arch structure. In this study, the response of the keel arch structure under multiple support excitation and with time lag are analyzed by means of the pseudo excitation method. Pseudo excitation method shows that the structural response is divided into two parts, ground displacement and structural dynamic response due to ground motion excitation. It is known that the seismic responses of spatial structure under multiple support excitation are different from those of spatial structure under simple excitation. And the seismic response of spatial structure with time lag are different from those of spatial structure without time lag. Therefore, it has to be necessary to analyze the seismic response of spatial structure under multiple support excitation and time lag because the spatial structure supports may be different and very long span. It is shown that the seismic response of spatial structure under multiple support seismic excitation are different from those of spatial structure under unique excitation.

Evaluation of the Moment Bearing Capacity of Offshore Bucket Platforms in Sand (사질토 지반에 설치된 해상 버켓작업대의 모멘트 지지력 산정)

  • Vicent, Ssenyondo;Gu, Kyo-Young;Kim, Sung-Ryul
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.12
    • /
    • pp.101-109
    • /
    • 2019
  • The bucket platform is a new structure suitable for construction of offshore bridge foundations and providing the temporary support for equipments and labour. The platform can be subjected to moment loading due to the eccentric loading or the horizontal load by wave and wind. Therefore, a three dimensional finite element analysis was performed to evaluate the moment bearing capacity of the bucket platform, varying soil density, the diameter and embedment depth of the bucket. The numerical modeling was verified and compared with the moment-rotation curve from a field loading test. The uniform sandy ground was assumed and the moment load was applied at the top plate of the platform, increasing bucket rotation. The moment-rotation relations were analyzed to determine the moment capacity, which was influenced by the embedment depth and diameter of the bucket. Finally, a preliminary design equation was suggested to estimate the moment bearing capacity.

Prediction of Biaxial Strength and Fatigue Life using the Concept of Equivalent Strength (등가강도 개념에 의한 탄소섬유 복합재료의 이축강도 및 피로수명 예측)

  • 이창수;황운봉
    • Composites Research
    • /
    • v.12 no.2
    • /
    • pp.53-61
    • /
    • 1999
  • A failure criterion must be considered in each failure mode and loading condition to provide easy determining strength parameters, flexibility and rational simplicity. In this study, new failure criterion was developed by introducing equivalent strength under biaxial loading of tension and torsion. The experimental results showed that the equivalent biaxial strength has a power law relation with respect to a parameter, cos($tan^{-1}R_b$). Failure strength under biaxial loadings could be predicted as a function of tensile strength, torsional strength and biaxial ratio. The scattering of experimental data could be predicted using a Weibull distribution function and the concept of equivalent biaxial strength. Also, in this study, a fatigue theory was developed based on a plane stress model which enabled the S-N curve for combined stress states to be predicted from the S-N data for uniaxial loading. The prediction models can be predicted a biaxial strength and fatigue life of general laminated composite naterials under multi-axial loadings.

  • PDF

Micro-vibration Control in Concrete Slabs (콘크리트 슬래브의 미진동 제어)

  • 노병철;변근주;양재성
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.2 no.4
    • /
    • pp.63-72
    • /
    • 1998
  • This study is to develop a technique for micro-vibration analysis and control of concrete slabs to fulfil the vibration criteria for working environments. The proposed technique is for determining the unknown forces from accelerance of two concerned points and the micro-vibration analysis and control of concrete slabs are then validated by numerical model and structural tests. And it is recommended that the natural frequency of structures for micro-vibration control design should be above 25 Hz~30 Hz, and 1.5 times forcing frequency in case of 3~5% structural damping ratio of concrete structures.

  • PDF

Application and development of Combustion Model for Fire Simulation in Building(III) (건축물 화재성상 시뮬레이션을 위한 연소확대 모델 개발 및 적용사례(III) - 외장재에 기인한 연소확대모델 -)

  • Kwon, Young-Jin;Kim, Dong-Eun;Hong, Hae-Ri;Kim, Se-Jong;Han, Jung-Chul;Seo, Yoon-Jeong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.32-36
    • /
    • 2011
  • 최근 건축물은 초고층화의 경향을 보이고 있으며 이에 따라 하중감소 및 에너지 절약을 위한 외장재를 사용하고 있으나 화재 안전성은 고려되지 않아 화재 위험성이 증가되고 있다. 또한 높은 층수에 의한 바람의 영향이 증가하여 화재 시 큰 변수로 작용될 위험성이 있다고 판단되었다. 이에 초고층에서의 화재 안전과 관련 규정이 추진되고 있으나 여전히 미흡한 실정이며 화재 안전 대책이 강구되고 있다. 이에 본 연구에서는 초고층건축물의 화재 시 외장재와 바람이 화재 성상에 미치는 영향을 알아보고자 2010년 부산에서 발생한 초고층 주상복합건축물의 화재 사고를 FDS를 통해 분석한 결과, 화재 시 풍속을 적용한 경우가 적용하지 않은 경우에 비해 빠른 수직, 수평 화염 확대를 보였으며, 높은 최대 HRR값을 보였다.

  • PDF

Control of Asymmetrical Tall Buildings under Wind Loading (비대칭 고층건물의 내풍 및 제진 해석)

  • 민경원;김진구;조한욱
    • Computational Structural Engineering
    • /
    • v.10 no.2
    • /
    • pp.203-211
    • /
    • 1997
  • In the design of tall building system, the wind loading can be more dominant factor than earthquake loading, and thus, it is important to check the stability and human comfort against wind. Experimental wind tunnel test is usually performed to predict wind behavior of a tall building, however, the test is not cost-effective in the preliminary stage for various structural models of tall building systems. In this regard, the study is focused on the numerical wind analysis of the tall building with and without tuned mass dampers based on the three dimensional model of wind loads and building behavior. As a numerical result, an asymmetrical 102-story tall building is presented to show the results of root mean squares of build responses with and without tuned mass dampers.

  • PDF