• 제목/요약/키워드: 바닥없는 표면

검색결과 241건 처리시간 0.026초

바닥복사 난방시스템의 밸브구동 특성을 고려한 실내 열환경 성능 개선 연구 (A Study on the Improvement of Indoor Thermal Performance of Floor Radiant Heating System Considering Valve Operation Characteristics)

  • 송재엽;안병천
    • 한국지열·수열에너지학회논문집
    • /
    • 제17권4호
    • /
    • pp.36-45
    • /
    • 2021
  • In this study, to improve the indoor thermal environment of the radiant floor heating system, a study was conducted on the temperature change characteristics and energy consumption according to the change of the indoor air set temperature, the supply hot water temperature and the outdoor temperature. As for the control method, the on/off control and the thermal difference proportional control method proposed through previous studies were applied. In addition, in consideration of field applicability, numerical analysis was performed for the case where the indoor air temperature sensor was affected by the wall temperature. As a result, it was found that the temperature difference proportional control method is more effective for thermal comfort and energy saving than on/off control.

고속도로 교량의 염소이온확산 특성과 공용수명 평가 (Diffusion of Chloride Ions and Evaluation of Lifetime in Highway Bridges)

  • 신재인;박창호;이병주;김형수
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제11권6호
    • /
    • pp.152-158
    • /
    • 2007
  • 염해는 구조물 열화의 원인이 되는 주요인자 중의 하나이다. 고속도로 교량에 있어서 제설제는 동결작용으로 인한 표면 스켈링을 매우 증가시킨다. 열화된 콘크리트는 염해환경에서 내구성이 저하된다. 본 연구에서는 147개 교량의 진단보고서를 조사하고 21개 교량 바닥판의 코어샘플에 대하여 실험과 분석을 실시하였다. 시험결과는 콘크리트 바닥판의 피복두께는 공용수명 30년 이상을 사용하려면 8cm이상이 필요하다는 것을 보여준다.

버블시트 피복양생법에 의한 소성 및 건조수축 균열저감 (Plastic and Drying Shrinkage Cracking Reduction by the Bubble Sheet Curing)

  • 이정교;한천구
    • 한국건축시공학회지
    • /
    • 제16권3호
    • /
    • pp.211-217
    • /
    • 2016
  • 본 연구에서는 2015년 가을철 실제 시공중인 고층 아파트를 대상으로 1중 백색 버블시트로 타설된 콘크리트의 표면을 덮어주는 버블시트 피복양생 공법과 표면을 노출한 채로 양생없이 유지하는 표면노출 방법간을 비교하여 소성 및 건조수축균열의 저감정도를 분석하였다. 실험 결과, 버블시트를 시공하였을 경우, 수화열 및 적산온도는 표면노출보다 약간 높았고, 바닥 균열의 갯수, 길이, 최대 균열폭, 균열 면적 모두 현저하게 적은 값이 측정되었다. 따라서 가을철 버블시트를 타설된 콘크리트 표면에 적용 할 경우에는 소성 및 건조수축균열을 획기적으로 방지할 수 있는 효과적인 표면피복 양생공법인 것으로 판단되었다.

접선유입방식의 여과집진장치 내에서의 내통이 유동장 및 입자거동에 미치는 영향 (Effect of Inner Tube on Flow Field and Particle Behavior inside Bag Filtration System with Tangential Inlet)

  • 박석주;김상도;최호경;박영옥
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2000년도 추계학술대회 논문집
    • /
    • pp.263-264
    • /
    • 2000
  • 여과포 표면상에 도달하는 입자의 농토를 낮추거나 균일하게 유지시킬 경우, 부착된 입자층 두께의 성장으로 인한 압력손실의 증가율을 줄일 수 있고 이로 인하여 탈진 주기 또한 감소시킬 수 있다. 탈진조작의 저감으로 인하여 여과포의 수명 증대로 여과포의 교체 시기를 연장시킬 수 있으므로 여과포 집진장치의 운전 및 유지 보수비의 저감을 이룰 수 있다. 본 연구에서는 집진용기의 중간부분에 위치한 접선 유입관을 통하여 오염입자를 함유한 기체유동을 유입시킨 후, 원심력과 난류확산에 의하여 집진용기 내벽과 내통(inner tube) 벽면에 부착된 입자는 중력에 의하여 용기 바닥으로 모인 후 바닥면에 설치된 스크래퍼(scraper)를 통하여 분리 처리될 수 있는 새로운 형상의 집진장치를 개발하고자 하였다. (중략)

  • PDF

기능성 실란 커플링제가 에폭시계 콘크리트 주차장 바닥용 마감재의 물리적 성능에 미치는 영향 (Effect on the Physical Performance of Functionalized Silane Coupling Agent on Epoxy-Based Concrete Surface Finishing Material for Parking Floor)

  • 채우병;성동연;서상교
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 춘계 학술논문 발표대회
    • /
    • pp.279-282
    • /
    • 2012
  • This study attempted to the effect on the physical performance of silane coupling agent on solventless epoxy-based concrete surface finishing material for parking floor. Tests were carried out in accordance with KS F 4041 and KS F 4937. The results of compressive strength, flexural compressive are 95.6N/㎟, 25.4N/㎟ and after wheel moving load testing, average abrasive depth is 0.96mm, these results satisfied the quality standard of KS F 4041, KS F 4937. As conclusion, this study confirmed that the silane coupling agent greatly effected on the physical performance of solventless epoxy resin.

  • PDF

경사인장형 바닥 미끄럼 시험방법의 표준화에 관한 연구 (A Study of Standardization of Floor Slip Test method using O-Y·PSM)

  • 신윤호;강용학;최수경
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.95-96
    • /
    • 2016
  • The floor slip test method using O-Y·PSM was developed based on the risk assessment and sense of slip by the users implementing actions such as changing walking direction on a floor. This test method is regulated under the Korea Industrial Standard KS M 3510, and in the Korea Industrial Standard KS F 3230, the article of KS M 3510 is cited. Yet, in the standard, the surface condition of test or slip adjustment method is merely mentioned or difficult to be found, and thus it creates confusion in floor slip test using O-Y·PSM. Therefore, this study is to provide the useful data to revise the relative standard through the standardization study including various surface conditions of sample and slip adjustment method used in floor slip test method using O-Y·PSM.

  • PDF

바닥온돌 매립형 환기덕트시스템의 온도변화에 대한 고찰 (The Changes of Temperature for Embedded Duct Ventilation System in Ondol)

  • 김옥;박진철;김남규;오재근
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.375-380
    • /
    • 2006
  • Embedded Duct Ventilation System in Ondol is embedded supply duct in Ondol. This system allows heat up outside air to inside temperature with out using heat exchanger and electric heating coiling in winter season. In this research, we measured temperature of inside and surface of Ondol, supply duct, and supply air temperature incorporate embedded duct ventilation system in Ondol in model house($110m^2$) & one room($23m^2$)

  • PDF

건축 내부 바닥 미장 자동화 로봇 플랫폼 개발 (Development of an Automated Indoor Floor Finish Robot Platform)

  • 문지윤;이동주
    • 한국전자통신학회논문지
    • /
    • 제18권5호
    • /
    • pp.853-858
    • /
    • 2023
  • 건설 산업에 다양한 종류의 로봇들이 활용되고 있다. 특히, 일관된 작업의 품질을 보장할 수 있는 미장 자동화에 적용할 수 있는 로봇에 관한 관심이 높다. 이에 본 논문에서는 wheel을 기반으로 미장 자동화를 위한 로봇 플랫폼을 제안한다. 실험을 통해 우리는 설계한 로봇을 이용하여 wheel의 공기압에 따른 표면 압력을 측정하였다. 그 결과, 설계한 로봇은 무른 모르타르 위에서 휠당 균일하고 낮은 압력으로 미장 작업이 가능할 것임을 확인할 수 있었다.

유한수심인 이상유체에서의 자유표면파의 수치모사 (Numerical Simulation of Wave Motions in Ideal Fluid of a Finite Depth)

  • Protopopov, Boris Ye.
    • 대한조선학회논문집
    • /
    • 제32권1호
    • /
    • pp.58-69
    • /
    • 1995
  • 본 논문에서는 이상유체모델에서의 비선형 자유표면파의 발생, 전파 및 상호간섭에 대한 비정상 문제의 수치해법을 개발하였다. 본 수치해법은 매 시간 스텝에서 비선형 축차해법을 이용한 음함수적(implicit)방법이다. 속도장함수를 구하기 위하여 경계접합좌표계를 도입한 유한차분법을 이용하였다. 본 수치해법의 유효성과 효율성의 검증을 위하여 타원형 유체의 변형과 바닥의 일부분이 올라옴으로서 발생하는 자유표면파의 생성에 대한 두 가지 계산결과를 보여준다.

  • PDF

필지논에서의 인(P) 과 산화환원전위(Eh)의 변화 특성 (Characteristics of Variation of Phosphorus and Redox Potential in an Experimental Paddy Field)

  • 김영현;김진수;장훈
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2009년도 학술발표회 초록집
    • /
    • pp.602-607
    • /
    • 2009
  • 논에서 수질변화특성에 관한 메카니즘은 매우 복잡하다. 영양물질의 농도특성을 정확히 파악하기 위해서는 영농활동에 따른 체계적인 모니터링을 통한 다양한 측정 자료가 필요하다. 그러나 현재 논에서 토양의 산화환원에 관한 연구 자료는 많지 않기 때문에 그의 특성을 파악하기에는 어려운 실정에 있다. 본 연구의 목적은 충북대학교 부속농장 필지논에서 2008년 영농기간을 중심으로 논에서의 영양물질인 총인(TP), 인산성 인($PO_4-P$) 및 산화환원전위(Eh)의 변화특성을 파악함으로써, 논으로부터의 영양물질 유출제어에 관한 기초 자료를 제공하는데 있다. 이 연구는 2008년 6월부터 10월까지 필지논에서 논 표면수의 TP 와 $PO_4-P$의 농도변화와 토양의 산화환원전위(Eh)와의 관계 특성을 파악하였다. 관개기의 논에서 인은 분얼비 시기에 인성분이 시비되지 않았는데도 불구하고 분얼비 직후와 분얼비 1주일 후에 TP농도가 높게 나타났는데 이는 담수의 영향으로 논이 환원상태로 되어, 논바닥에 침전된 철이온에 흡착되어 있던 인이 철이온의 환원으로 함께 용출하기 때문이라고 생각된다. 산화환원전위(Eh)는 높아지면 산화경향을, 낮아지면 환원경향을 나타낸다. 본 연구기간 동안의 산화환원전위(Eh) 값은 비 관개기에 $201^{\sim}405$ mV로 높게 나타났고, 관개기에는 $93^{\sim}195$ mV로 낮게 나타났다. 필지논 표면수의 인농도는 분얼비 직후 1주일후까지 TP 와 $PO_4-P$ 농도는 같이 상승하다가 TP농도는 약 2주일까지 더 상승하여 2008년 최대값을 나타냈고 $PO_4-P$농도는 하강하였는데 이는 논 토양이 환원상태로 되면서 바닥에 있던 입자성 인이 논 표면으로 떠올랐기 때문으로 사료된다. 그 후에 담수가 끝나는 시점까지 농도는 낮아졌다. 강우량이 적은 관개초기에 인의 농도는 비교적 높게 나타났지만 강우량이 많은 여름에는 작물의 생장에 필요한 영양물질 섭취 등으로 인농도가 낮게 나타나 논은 인의 유출을 억제하고 있는 것으로 나타났다. 이와 같이 인의 유출특성 및 산화환원전위(Eh)의 변화에 따른 논에서의 유출부하 특성이 규명된다면, 환경부하가 적은 효과적인 물관리가 가능해 질 것으로 판단된다.

  • PDF