• 제목/요약/키워드: 바깥 반경

Search Result 20, Processing Time 0.251 seconds

Investigation on backscatter According to Changed in Components of Linear Accelerator Using Monte Carlo Simulation (몬테카를로 시뮬레이션을 이용한 선형가속기 구성요소 변화에 따른 후방산란에 관한 연구)

  • Kim, Hwein;Chon, Kwonsu
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.4
    • /
    • pp.239-247
    • /
    • 2015
  • It should be accurate dose calculation to increase the efficiency of radiation therapy, and it is priority to figure out the beam characteristics for this purpose. The target and primary collimator in head components of the linear accelerator have the greatest influence on determining the beam characteristics which is caused by backscatter and it is the factor to consider the shielding structures and equipment management. In this study, we made modeling of the linear accelerator through the Geant4 Monte Carlo simulation and investigated backscatter according to the change of the size and shape in head components. For the scattered electrons, it showed the greatest number of distributions inside of the inner radius at primary collimator. But, for the scattered photons which have the high energy, it was mostly located outside of the inner radius at primary collimator. Scattered positrons showed a small occurrence in about 0.03%. According to the change of the inner radius at primary collimator, it was great changes in the inside of inner radius for all three scattered particles. According to the change of the outer radius at primary collimator, it was shown some considerable effects from more than 60 mm outer radius. It was no significant effect according to the change of target thickness. In this study, we found that backscatter should be considered, and figured out that geometric size and shape of the peripheral components are the factors that influences the backscatter effect.

Phase Asymmetry Effect on Vesicle Fusion Induced by Phospholipase D (인지질분해효소D에 의해 유도된 소낭 융합에 대한 상 비대칭의 영향)

  • Park, Jin-Won
    • Korean Chemical Engineering Research
    • /
    • v.53 no.6
    • /
    • pp.672-676
    • /
    • 2015
  • Spherical phospholipid bilayers, vesicles, were formed with respect to phase of each layer via a double emulsion technique. The conversion of phosphatidylcholine (PC) to phosphatidic acid (PA) at the outer layer, caused by phospholipase D (PLD), induced a curvature change in the vesicles, which eventually led them to fuse each other. The effect of the lipid layer physical-properties on the PLD-induced vesicle fusion was investigated using the fluorescence intensity change. 8-Aminonaphthalene-1,3,6-trisulfonic acid disodium salt(ANTS) and p-Xylene-bis(N-pyridinium bromide)(DPX) were encapsulated in the vesicles, respectively, for the quantification of the fusion. The fluorescence scale was calibrated with the fluorescence of a 1/1 mixture of ANTS and DPX vesicles in NaCl buffer taken as 100% fluorescence (0% fusion) and the vesicles containing both ANTS and DPX as 0% fluorescence (100% fusion), considering the leakage into the medium studied directly in a separate experiment using vesicles containing both ANTS and DPX. It was observed that the fusion occurred to the liquid-phase of the inner layer only. The fusion behaviors were very similar for both solid and liquid of the outer layer. However, the leakage was faster for the solid-phase outer-layer than the liquid-phase outer-layer. The difference in the leakage seems to be caused by the lipid concentration and the lateral diffusivity in the layer.

대칭 및 비대칭 binary filter가 수차를 포함한 광학계의 축상 GAIN에 미치는 영향

  • 최기준;정창섭;심상현
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.3
    • /
    • pp.165-171
    • /
    • 2001
  • We discuss the influence of annular binary filters on the axial PSF of imaging systems which are apodized by a radiallysymmetric filter and have spherical aberration and coma. In this paper we consider a whole family of annular binary fIlters in two cases. First, the binary filters are composed of two transparent annuli of the same area. Second, the binary filters are composed of a central clear circle and a concentric annular aperture with area bigger than that of the inner circle. In order to investigate the influence of the proposed filters on the axial PSF, we may use the axial resolution gains, which evaluate in terms of the FWHM of the intensity in the focal region of an apodized imaging system in comparison with that corresponding to a nonapodized one. We evaluate the PSF for the conventional and confocal systems having an aberration. ation.

  • PDF

Development of the blade shape design (밭 농업 제초날 형상 설계)

  • Kim, T.W.;Lee, H.J.;Lee, S.H.;Kim, T.W.;Kim, J.H.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.83-83
    • /
    • 2017
  • 국내에 유통되는 제초날은 대부분 금속으로 제작되며, 금속 날의 대부분 탄소공구강(SK-3~5)으로 제작되고, 날 수 및 날 형태에 따라 2도 날, 3도 날, 4도 날, 8도 날, 톱날로 구분된다. 대부분 평지 제초작업에 사용되고, 고랑 제초 작업에 알맞은 제초날의 없어 고랑 제초 작업의 효율이 떨어진다. 본 연구는 굴곡이 있는 밭의 고랑 제초 작업에 효율적인 원형 제초날을 설계 하고자 한다. 밭작물의 제초작업은 굴곡이 있는 이랑과 고랑 사이의 잡초를 제거해야 하기 때문에 평지의 잡초를 제거하는 제초날로는 제초작업이 거의 불가능하다. 따라서 고랑 형상에 맞는 원형 제초날을 설계 하였으며, 회전 균형 및 무게의 균일성 설계가 쉬운 뼈대형 원형 제초날을 설계한 후 데이터를 이용하여 원형 제초날을 설계하였다. 또한 고랑의 잡초 뿌리부분을 제거하기 위해 원형 제초날에 돌출부를 추가하는 방법으로 설계하였다. 제초날은 밭작물 고랑폭을 기준으로 하여 높이는 85mm 직경은 300mm로 설계하였으며, 제초날 설계시 원형 제초날은 뼈대형 원형 제초날과 같이 고랑폭을 기준으로 하여 높이 및 직경을 뼈대형 원형 제초날과 동일한 치수로 설계하였다. 원형 제초날 설계에서 돌출부를 볼트 결착방식으로 설계하였으며, 회전중 돌출부의 파손 혹은 이탈을 방지하기 위하여 직경 5mm이상의 볼트 결착이 필요하였다. 볼트 결착방식은 제초날 조립후 제초날 회전시 고랑의 잡초를 효과적으로 제거하기 위한 작업공간 확보가 어려울 것으로 판단되었다. 따라서 제초날 원형부에 돌출부를 절단 절곡하는 방식으로 돌출부를 재설계하였으며, 돌출부 길이는 안쪽 부분 15mm, 바깥 부분 20mm로 설계하고, 돌출부 회전반경은 안쪽 날 20mm, 바깥 날 10mm로 설계하였다. 일반적인 제초날 과 달리 원형 제초날을 개발하기 위해서 회전균형과 안전이 제초날 설계에 중요한 요인이 된다. 뼈대형 제초날을 통하여 제초날의 균형 데이터를 분석하였고 이를 바탕으로 원형 제초날을 설계하였다. 또한 발란싱 머신을 이용한 회전시험에서 unbalance 정도가 3,600rpm에서 4.51/47.1deg로 나타나 제초기에 적용 가능할 것으로 판단되었다.

  • PDF

Attenuation Structure of the Mt. Fuji Region, Japan (일본 후지산의 감쇠구조)

  • Chung, Tae-Woong;Lees, Jonathan M.;Yoshimoto, Kazuo;Fujita, Eisuke;Ukawa, Motoo
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.97-100
    • /
    • 2008
  • Mount Fuji is the focus of intense study because of its potential hazard signaled by seismic, geologic and historical activity. Based on extensive seismic data recorded in the vicinity of Mt. Fuji, coda quality factor ($Q_c^{-1}$) using a single scattering model hypothesis, and intrinsic and scattering quality factor $(Q_i^{-1}$ and $Q_s^{-1})$ using the Multiple Lapse Time Window Analysis (MLTW) method was measured. To focus the study on the magmatic structure below Mt. Fuji, to the data were separated into two groups: a near-Fuji region of rays traversing an area with radius 5 km around the summit (R < 5 km), and a far-Fuji region of rays beyond a radius of 20 km around the summit (R > 20 km). The results of the study have a small error range due to the large data sample, showing that all $Q^{-1}$ values in near-Fuji area are greater than those of far-Fuji area, and $Q_i^{-1}$ for both the near and far-Fuji area is higher than $Q_s^{-1}$ at high frequencies. The $Q_i^{-1}$ values of the near-Fuji area are lower than those of the other volcanic areas considered, while values of $Q_s^{-1}$ are not. The low $Q_i^{-1}$ for the volcanic region of near-Fuji suggests that the magmatic activity, or percent of partial melt, at Mt. Fuji is not as active as hot spot volcanoes such as Kilauea, Hawaii.

  • PDF

Development of a model to predict Operating Speed (주행속도 예측을 위한 모형 개발 (2차로 지방부 도로 중심으로))

  • 이종필;김성호
    • Journal of Korean Society of Transportation
    • /
    • v.20 no.1
    • /
    • pp.131-139
    • /
    • 2002
  • This study introduces a developed artificial neural networks(ANN) model as a more efficient and reliable prediction model in operating speed Prediction with the 85th percentile horizontal curve of two-way rural highway in the aspect of evaluating highway design consistency. On the assumption that the speed is decided by highway geometry features, total 30 survey sites were selected. Data include currie radius, curve length, intersection angle, sight distance, lane width, and lane of those sites and were used as input layer data of the ANN. The optimized model structure was drawn by number of unit of hidden layer, learning coefficient, momentum coefficient, and change in learning frequency in multi-layer a ANN model. To verify learning Performance of ANN, 30 survey sites were selected while data in obtained from the 20 cites were used as learning data and those from the remaining 10 sites were used as predictive data. As a result of statistical verification, the model D of 4 types of ANN was evaluated as the most similar model to the actual operating speed value: R2 was 85% and %RMSE was 0.0204.

Flow of Non-Newtonian Fluids in an Annulus with Rotation of the Inner Cylinder (안쪽축이 회전하는 환형관내 비뉴튼유체 유동 연구)

  • 김영주;우남섭;황영규
    • Tunnel and Underground Space
    • /
    • v.12 no.4
    • /
    • pp.277-283
    • /
    • 2002
  • This experimental study concerns the characteristics of a helical flow in a concentric annulus with a diameter ratio of 0.52, whose outer cylinder is stationary and inner one is rotating. The pressure losses and skin friction coefficients have been measured for the fully developed flow of Non-Newtonian fluid, aqueous solution of sodium carbomethyl cellulose (CMC) and bentonite with inner cylinder rotational speed of 0~400 prm. Also, the visualization of helical flows has been performed to observe the unstable waves. The results of present study reveal the relation of the Reynolds number Re and Rossby number Ro with respect to the skin friction coefficients. In somehow, they show the existence of flow instability mechanism. The pressure losses increase as the rotational speed increases, but the gradient of pressure losses decreases as the Reynolds number increases in the regime of transition and turbulence. And the increase of flow disturbance by Taylor vortex in a concentric annulus with rotating inner cylinder results in the decrease of the critical Reynolds number with the increase of skin friction coefficient.

Application of Transverse Flow Profile to Two Dimensional Models in Open Channels (개수로에서 이차원 모델의 이차류 유속분포 적용에 관한 연구)

  • Seo, Il Won;Shin, Jaehyun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.68-68
    • /
    • 2016
  • 하천의 사행 및 합류 형상은 복잡한 나선 흐름을 발생시킨다. 그 중 이차류는 사행에 의한 편수위 형성과 횡단 압력의 불균형, 그리고 수심에 따라서 변화하는 원심력에 의하여 형성된다. 이러한 흐름은 주로 3차원 모형으로 재현할 수 있으며 이에 관련된 연구는 계속 이루어졌으나 3차원 모형의 구성과 사용에는 상당한 시간 및 노력이 요구된다. 본 연구에서는 이러한 이차류의 영향을 수심적분된 2차원 모형으로 구현하고자 하였으며 이를 위해 이차류 연직 분포에 대한 기존 연구를 확인하고, 이러한 연직 분포를 표현할 수 있는 경험식을 3차원 모형인 FLOW3D를 통해 모의하고 개발하였다. 3차원 모형을 다양한 사행반경을 갖는 실험 사행수로에 적용하여 사행도에 따른 민감도를 분석하고 경험식을 개발하였다. 개발된 식은 2차원 수리해석 모형인 RAMS(River Analysis and Modeling System)에 적용되었다. RAMS는 수심 적분된 2차원 천수 방정식을 지배방정식으로 사용하는 수리해석모형인 HDM-2D를 해석엔진으로 사용하며, 이차류의 영향을 반영하기 위하여 개발한 수직분포 경험식을 분산 응력항 형태로 적용하였다. 모형의 적용성 확인을 위하여 사행 실험수로 및 합류수로에 모의를 수행하였다. 사행수로 및 합류수로는 실험 경계조건과 동일한 상류 입력 유량과 하류 경계조건을 사용하여 결과를 비교하였다. 사행수로 모의 결과 유속분포의 거동이 실험수로의 사행으로 인하여 2차류 효과로 주 흐름이 바깥쪽으로 기울어짐을 일부 재현하였다. 합류수로의 경우 기존 모형에 비하여 분산 응력항이 포함된 본 모형이 실측값에 근접하였는데 이는 이차류가 발생하는 영향으로 하류에 유속편차가 줄어드는 영향을 더 정확히 묘사한 것으로 판단된다.

  • PDF

Vibration of Contact Lenses (콘택트 렌즈의 진동에 관한 연구)

  • Kim, Dae Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.1
    • /
    • pp.13-29
    • /
    • 2001
  • A mathematical model was proposed to analyze the vibration of diaphragm, such as the contact lenses fitted on the eyes, being subjected to the external sinusoidal pressure. The model incorporates the differential equations and their numerical solution program, based on the wave equations. Turbo-C and graphic software, formulated to describe the dependence of the various parameters involved in the vibration. The model predicts the radial distribution of amplitude, frequency dependence of both average displacement amplitude and the power of diaphragm whose edge is being either simply supported or rigidly clamped in vibration. The effect of variables such as thickness, radius, damping coefficients on the vibration characteristics was illustrated by the computer simulation of the derived program. As the frequency of driving pressure increases above the certain value determined by the boundary conditions and parameters the wave shape or pattern changes from simple arc to belly or loops having double antinode. It seems that the effect of outer antinode progressively increases as the frequency increases. If this kind of phenomena occurs to the contact lens on the cornea in vivo, it may cause an abnormal correction power in the lenses or pull off the eye due the increased rise of outer part of the lens.

  • PDF

Performance Characteristics of MicroPET R4 Scanner for Small Animal Imaging (소동물 영상을 위한 MicroPET R4스캐너의 특성평가)

  • Lee, Byeong-Il;Lee, Jae-Sung;Kim, Jin-Su;Lee, Dong-Soo;Choi, Chang-Un;Lim, Sang-Moo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.1
    • /
    • pp.49-56
    • /
    • 2005
  • Purpose: Dedicated animal PET is useful equipment for the study of new PET tracer. recently, microPET R4 was installed in the Korea institute of radiology and medical science. In this study, we measured the characteristics of scanner. Materials and methods: Resolution was measured using a line source (F-18:65 ${\mu}Ci$, inner diameter: 0.5 mm). The line source was put in the axial direction and was moved from the center of field of view to outside with 1 mm interval. PET images were reconstructed using a filtered back-protection and ordered subset expectation maximization. line source (16.5 ${\mu}Ci$, 78 mm) was put on the tenter of axial direction to measure the sensitivity when the deadtime was under 1%. Images were acquired during 4 minutes respectively from center to 39 mm outward. Delayed count was subtracted from total count and then decay was corrected for the calculation of sensitivity. Noise equivalent count ratio and scatter fraction were calculated using cylindrical phantom. Results: Spatial resolution of reconstructed image using filtered back-projection was 1.86 mm(radial), 1.95 mm(tangential), 1.95 mm(axial) in the tenter of field of view, and 2.54 mm, 2.8 mm, 1.61 mm in 2 cm away from the center respectively. Sensitivity was 2.36% at the center of transaxial field of view. Scatter fraction was 20%. Maximal noise equivalent count ratio was 66.4 kcps at 242 kBq/mL. Small animal images were acquired for confirmation of performance. Conclusion: Performance characteristics of microPET R4 were similar with reported value. So this will be a useful tool for small animal imaging.