• Title/Summary/Keyword: 밀폐형 공간

Search Result 55, Processing Time 0.021 seconds

Types of Smart Bus Stop and Their Impacts on Reducing Fine Dust Concentrations in Seoul (스마트버스정류장 유형에 따른 미세먼지 농도 저감효과)

  • Seo, Jeongki;Kim, Hyungkyoo
    • Land and Housing Review
    • /
    • v.12 no.3
    • /
    • pp.39-50
    • /
    • 2021
  • This research aims to provide guidelines with the appropriate type of smart bus stop to reduce the concentration of fine dust. To this end, we divided smart bus stops into two types: closed and open bus stops. The estimated reduction effect was compared and analysed by measuring the estimated PM10 and the estimated PM2.5 at five locations inside and outside a smart bus stop located in Gangnam gu, Seoul. The effect of reducing the amount of the fine dust concentration in external space was insignificant for both types of bus stops. The different effect of reducing the concentration of the amount between in internal space was relatively significant: the fine dust concentration was 26.0 ㎍/m3 for PM10 and 20.2 ㎍/m3 for PM2.5 at open-type bus stops; whilst was 2.4 ㎍/m3 for PM10 and 1.8 ㎍/m3 for PM2.5 at closed type bus stops. Based on the findings, a closed type bus stop is recommended when considering the cost of reducing fine dust. In addition, due to the ineffectiveness of reducing the amount of fine dust from the outside of the bus stop, additional provision of smart bus stops is required particularly in locations where demand exceeds the capacity of the inside. A clear definition of smart bus stop and it's minimum standard should also be considered.

Measurement and evaluation of speech privacy in university office rooms (대학 내 사무실의 스피치 프라이버시 측정 및 평가)

  • Lim, Jae-Seop;Choi, Young-Ji
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.4
    • /
    • pp.396-405
    • /
    • 2019
  • The speech privacy of closed office rooms located in a university campus was measured and assessed in terms of SPC (Speech Privacy Class) values. The measurements of two quantities, the LD (Level Difference) between a source and a receiving room, and the background noise level ($L_b$) at the receiving room were carried out in 5 rooms located in 3 different buildings in the university campus. Each of the 5 rooms was adjacent to both offices and corridors through walls. The TL (Transmission Loss) between the source and the receiver room was also measured to compare the difference of two standard methods, ASTM E2836-10 and KS F 2809. The present results show that the speech privacy of the 5 office rooms is not met the requirement for a minimum SPC values of 70. A minimum LD value of 41 dB between the source and the receiver room should be achieved for having a SPC value of 70 when the mean measured value of $L_b$ at the receiving room is 29.2 dB. That is, the TL(avg) value averaged over the octave bands from 160 Hz to 5000 Hz between the source and the receiver room should be or greater than 40 dB. The most important architectural factor influencing the LD value is the presence of openings, such as doors, and windows, on the adjacent walls between the source and receiving room. Therefore, if the opening of the adjacent wall is replaced by an opening with high sound insulation, the appropriate SPC value of the research and office rooms can be achieved.

Screw 치형의 특성값에 관한 연구

  • 오형식;최상훈
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1993.04b
    • /
    • pp.146-150
    • /
    • 1993
  • screw압축기는 진동이 적고, 소형이면도 그효율 유지가 용이하다는 특징을 가지고있으며, 왕복압축기와 같은 crank가 없고 원통형 밀폐용기 내에 암,수 로타가 서로 반대 방향으로 맞물려 회전하면서 로타홈과 케이싱 사이에 생기는 공간의 용적이 로타의 회전에 의해서 가스를 연속적으로 흡입, 압축, 배출하는 용적형압축기이다. 본 연구는 screw 압축기의 성능에 큰 영향을 미치는 로타의 치형함수의 기하학적성질 및 제한사항을 서술하였고, 로타의 형상이 특성값에 미치는 영향을 이론적으로 해석 하기 위하여, 임의의 치형을 갖는 로타를 만들고, 이것과 맞물리는 상대로타의 치형을 설계하여 seal line length와 blow hole area을 계산하였다.

에어컨용 냉매압축기

  • 이승갑;소순갑;최영민
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.31 no.11
    • /
    • pp.8-14
    • /
    • 2002
  • 가정용 룸에어컨이나 가정, 점포, 사무실에 사용하는 패키지에어컨은 쾌적한 주거 사무공간을 실현할 수 있기 때문에 최근 10년 동안에 광범위하게 보급되었고, 그 기술도 해마다 진보하고 있다. 그림 1에서 나타나듯이 2001년 가정용 룸에어컨의 국내생산 수량은 연간 600만대 수준이며, 패키지에어컨은 연간 약 80만대 수준이다. 2001년 기준으로 에어컨의 국내시장규모는 약 130만대로 세대 보급률이 약 40%에 도달하고 있다. 비록 패키지에어컨은 생산 수량면에서는 룸에어컨과 비교할 수 없지만, 한대의 냉방능력이 룸에어컨의 수배에서 수십배로 크기 때문에 전력에너지소비, 환경 등에 미치는 영향은 룸에어컨과 비견될 수 있다. 공조장치 보급에 따른 환경, 에너지 측면에서의 사회적 영향과 관심이 점차 커지고 있고, 이것을 개선하기 위한 기술개발이 활발하게 진행되고 있다. 에어컨을 포함한 공조장치의 다수는 효율이 좋은 증기 압축식 냉동사이클로써 구성되어 있으며, 증기 압축식 사이클에서 냉매가스를 압축하여 순환시키는 심장역할을 하고 있는 것이 압축기이다. 또한 압축기는 공조장치 전체의 전력소비의 80%에서 90%을 차지하고 있어 에너지절감 기술개발과 환경기술개발의 포인트가 되는 기구이다. 최근에 에어컨용 냉매압축기의 기술적인 개발동향을 정리하면 다음과 같은 경향으로 진행되고 있다. (1)오존층 파괴 지수가 제로인 친환경 HFC계와 자연냉매용 밀폐형 압축기기술 (2)로터리압축기의 성능향상 및 대용량화 기술 (3)압축기용 모터의 DC화통에 의한 모터 효율 향상 및 압축기 효율 향상 기술 (4)스크롤압축기의 압축비 변화의 대응, 고효율 유지, 대용량화 등 성능향상기술 (5)로터리, 스크롤, 왕복동 압축기를 이용한 용량가변기술 본 논고에서는 룸에어컨과 패키지에어컨에서 사용되고 있는 밀폐형 압축기에 대해서 그림 2에서 나타내고 있는 냉방능력 10tons(120,000Btu/h) 이하를 중심으로 상기의 최근 기술 동향을 간략하게 소개하고자 한다.

  • PDF

A Study on the Correlation between Inflowing Air Discharge and Smoke Control Performance through TAB (TAB를 통한 유입공기 배출과 제연성능 상관관계 연구)

  • Lee, Hye-Young
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2022.10a
    • /
    • pp.215-216
    • /
    • 2022
  • 유입된 공기가 배출될 때 중앙코어형 건축물이나 지하층처럼 밀폐된 공간의 경우 옥내에 부압이 형성되며 제연구역과 과도한 압력차이로 출입문 개방에 필요한 힘을 초과하는 등 많은 문제들을 야기할 수 있다. 유입공기 배출댐퍼가 적용된 ◯◯오피스텔을 사례로 실제 TAB(Testing, Aejuwting, Balancing)를 수행하여 유입공기 배출에 따른 영향과 제연성능의 개선방안을 알아보고자 하였다. 유입공기 배출댐퍼를 순차적으로 개방해 가며 차압 및 방연풍속 등의 변화를 기록한 결과 밀폐된 복도에서 유입 공기 배출댐퍼가 개방되면 복도에 부압이 형성되고 제연구역에 과도한 압력이 발생하여 출입문 개방에 필요한 힘을 초과하였다. 유입공기 배출댐퍼 개방 층수를 증가시켜 TAB를 수행한 결과 3개층 까지 개방하여도 방연풍속이 확보되었다.

  • PDF

A Study on the Application of Thermal Insulation Composite Frame for Welding in Enclosed Space (밀폐 공간에서 용접작업을 위한 단열 복합재 프레임의 설계 적용 연구)

  • Lee, Jae-Youl;Jeong, Kwang-Woo;Hong, Sung-Ho;Shin, Kwang-Bok
    • Composites Research
    • /
    • v.31 no.5
    • /
    • pp.227-237
    • /
    • 2018
  • In this paper, the design application for the lightweight and insulation of the manipulator of the mobile welding robot for the closed/narrow space is presented. A variety of robotic platforms have been developed for weld-worker using a welding robot outside a workpiece for welding work in a complex and narrow space such as a ship or an offshore plant. Normally, The development process of robots consists of machine development, electronic device development, control algorithm development and integration verification considering application environment and requirements. In order to develop the robustness of the welding robot, the lightweight design of the robot manipulator considering the environmental conditions was performed in the basic design of the robot platform. Also, The results of the robot selection and validation, analysis and testing for the insulation performance and cooling performance and the results of the research are shown.

A Fundamental Study on Development of a Wall Structure type Thermal Diode for Energy Saving (에너지 절약을 위한 벽체형 열다이오드 개발에 관한 기초)

  • Pak, E.T.;Chang, Y.G.;Chea, S.S.
    • Solar Energy
    • /
    • v.17 no.3
    • /
    • pp.67-73
    • /
    • 1997
  • In order to development of a new wall structure type thermal diode for energy saving, the numerical studies have been performed for natural convection across an rectangular enclosure with the various lengthes of the heat source and sink plate. The governing equations for the two-dimensional, laminar, natural convection process in an enclosure are discretized by the control volume approach which insures the conservative characteristics to be satisfied in the calculation domain, and solved by a elliptic SIMPLE algorithm. The momentum and energy equations are coupled through the buoyancy term.

  • PDF

A Study on the Turbulent Natural Convection - Radiative Heat Transfer In a Partitioned Enclosure (차폐막이 있는 밀폐공간 내에서의 난류 자연대류 - 복사열전달에 관한 연구)

  • 박경우;이주형;박희용
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.10
    • /
    • pp.2738-2750
    • /
    • 1994
  • The Effects of radiative heat transfer on turbulent flow in a partitioned enclosure is studied numerically. The enclosure is partially divided by a thin, poorly conducting vertical divider projecting from the ceiling of the enclosure. The low Reynolds number $k-{\epsilon}$ model is adopted to calculate the turbulent flow field. The solutions to the radiative transfer equations are obtained by the discrete ordinates method(DOM). This method is based on control volume method and is compatible with the SIMPLER algorithm used to solve the momentum and energy equations. The effects of optical thickness and Planck number on the flow, temperature fields and heat transfer rates are investigated for a moderate Rayleigh number($=10^9$). The changes in buoyant flow fields and temperature distributions due to the variation of baffle length are also analyzed. From the predictions, radiant heat exchange between the baffle and the sidewalls strongly influences the temperature distribution in the baffle and its vicinity and total heat transfer increases as the optical thickness and the baffle length decrease. It is possible to neglect the radiative heat transfer effect when Planck number is over one.

Analysis of Spatial and Vertical Variability of Environmental Parameters in a Greenhouse and Comparison of Carbon Dioxide Concentration in Two Different Types of Greenhouses (온실 환경요인의 공간적 및 수직적 특성 분석과 온실 종류에 따른 이산화탄소 농도 비교)

  • Jeong, Young Ae;Jang, Dong Cheol;Kwon, Jin Kyung;Kim, Dae Hyun;Choi, Eun Young
    • Journal of Bio-Environment Control
    • /
    • v.31 no.3
    • /
    • pp.221-229
    • /
    • 2022
  • This study was aimed to investigate spatial and vertical characteristics of greenhouse environments according to the location of the environmental sensors, and to investigate the correlations between temperature, light intensity, and carbon dioxide (CO2) concentration according to the type of greenhouse. Temperature, relative humidity (RH), CO2, and light sensors were installed in the four-different vertical positions of the whole canopy as well as ground and roof space at the five spatial locations of the Venlo greenhouse. Also, correlations between temperature, light intensity, and CO2 concentration in Venlo and semi-closed greenhouses were analyzed using the Curve Expert Professional program. The deviations among the spatial locations were larger in the CO2 concentration than other environmental factors in the Venlo greenhouse. The average CO2 concentration ranged from 465 to 761 µmol·mol-1 with the highest value (646 µmol·mol-1) at the Middle End (4ME) close to the main pipe (50Ø) of the liquefied CO2 gas supply and lowest (436 µmol·mol-1) at the Left Middle (5LM). The deviation among the vertical positions was greater in temperature and relative humidity than other environments. The time zone with the largest deviation in average temperature was 2 p.m. with the highest temperature (26.51℃) at the Upper Air (UA) and the lowest temperature (25.62℃) at the Lower Canopy (LC). The time zone with the largest deviation in average RH was 1 p.m. with the highest RH (76.90%) at the LC and the lowest RH (71.74%) at the UA. The highest average CO2 concentration at each hour was Roof Air (RF) and Ground (GD). The coefficient of correlations between temperature, light intensity, and CO2 concentration were 0.07 for semi-closed greenhouse and 0.66 for Venlo greenhouse. All the results indicate that while the CO2 concentration in the greenhouse needs to be analyzed in the spatial locations, temperature and humidity needs to be analyzed in the vertical positions of canopy. The target CO2 fertilization concentration for the semi-closed greenhouse with low ventilation rate should be different from that of general greenhouses.

Natural Convection Within a Wedge-Shaped Enclosure (쐐기형 밀폐 공간 내에서의 자연 대류 열전달)

  • Bae, T.Y.;Kwon, S.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.3
    • /
    • pp.259-266
    • /
    • 1994
  • Natural convection within a wedge-shaped enclosure has been studied numerically by finite difference method. Radial surfaces of the wedge are isothermally hot and cold while circumferential surfaces are insulated. Results show isotherms, streamlines and velocity profiles as well as Nusselt number distributions for a Rayleigh number range of $10^3$ to $10^5$. In addition, it is found that there is a wedge angle as shown the minimum mean Nusselt number for using an insulated enclosure.

  • PDF