• Title/Summary/Keyword: 밀도 측정

Search Result 2,910, Processing Time 0.031 seconds

Thermal Conductivity of Dry and Saturated Cores from Ulleung Island in a Constant Temperature and Humidity Condition (항온항습 환경에서 울릉도 시추코어의 건조·수포화 열전도도)

  • Lee, Keun-Soo;Lee, Sang Kyu;Lee, Tae Jong
    • Geophysics and Geophysical Exploration
    • /
    • v.21 no.4
    • /
    • pp.220-230
    • /
    • 2018
  • When thermal conductivity of rock is measured with PEDB (Portable Electronic Divided Bar) in a laboratory, it can be greatly influenced by the change of room temperature. Therefore, measuring the thermal conductivity in a thermo-hygrostat is necessary, where it can remain in its constant temperature and humidity condition. In this study, a system for thermal conductivity measurement in a thermo-hygrostat has been set up and the thermal conductivities for the 45 samples collected from GH3 and GH4 boreholes in Ulleung Island have been measured both in dry and saturated conditions. Also, the correlations between those thermal conductivities, density, and effective porosity have been discussed. As a result of correlation analysis among the thermal conductivity, density, and effective porosity, it showed higher correlation with dry samples than saturated samples. Especially, thermal conductivity ratio between saturated and dry conditions shows very high correlation ($R^2=0.90$) with effective porosity.

New Method of Volume Measurement for Reference Weights of a Pressure Balance Using a Gas Pycnometer (기체용적계를 이용한 분동식 압력계용 기준분동의 새로운 부피측정 방법)

  • Lee, Yong Jae;Lee, Woo Gab;Mohammed, Mohammed Abdurahman;Park, Yon-Kyu;Oh, Chae Yoon
    • Journal of the Korean Vacuum Society
    • /
    • v.22 no.5
    • /
    • pp.231-237
    • /
    • 2013
  • New method of volume measurement for reference weights of a pressure balance using a gas pycnometer is proposed. The result of volume measurement of proposed method shows the uncertainties of approximately 0.2% at the level of confidence of 95% for reference weights in the ranges of 1 kg, 2 kg, and 5 kg. This measuring system consists of a sample chamber, an expansion chamber, a precision pressure gage, a precison thermometer, a vacuum pump, and helium as a medium gas. The measurement principle of this proposed method is based on Boyle's law. This method will contribute a reliability of the volume measurements of reference weights for a pressure balance to the national measurement standard.

다양한 공정 주파수에서 유도 결합 플라즈마의 플라즈마 밀도와 에너지 전달 효율 측정

  • Lee, Jae-Won;Choe, Ik-Jin;Lee, Yeong-Gwang;Jeong, Jin-Uk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.242-242
    • /
    • 2011
  • 현재 반도체 및 디스플레이 장비들이 공정 매개변수 및 플라즈마 변수를 독립적으로 제어하기 위하여 전원 주파수를 다양하게 사용된다. 플라즈마의 상태나 에너지 전달 효율은 반도체 및 디스플레이 공정에 중요한 요소이다. 따라서 플라즈마 발생장치의 전원 주파수를 바꾸었을 때의 플라즈마 밀도와 에너지 전달 효율에 관하여 연구하였다. 공정용 유도 결합 플라즈마(ICP)를 발생시키기 위하여 신호 발생기에서 전력 증폭기와 임피던스 정합회로(Matcher)를 거쳐 반응 용기에서 플라즈마를 발생시켰다. 6 mTorr의 압력에서 주파수는 13.56 MHz에서부터 80 MHz까지, 15~60 W의 전력을 인가하였다. 플라즈마의 에너지 효율을 측정은 제작한 로고스키코일(Rogowski Coil)을 이용하여 시스템 전반을 등가회로로 계산하였으며, 플라즈마 밀도는 반응용기 중앙에서 부유 탐침법을 적용하여 도출하였다. 같은 전력 조건에서 주파수가 증가함에 따라 플라즈마 밀도가 증가함을 볼 수 있었다. 그러나 플라즈마 에너지 효율은 주파수가 높아짐에 따라 점점 커지다 작아지는 경향을 볼 수 있었다. 에너지 전달 효율의 변화는 정합회로의 표피효과(Skin effect)에 기인하며 플라즈마 밀도의 변화는 이온의 에너지 손실에 기인한다.

  • PDF

Noise Reduction for Dual-energy X-ray Absorptiometry Image using Sparse Representation (Sparse 표현을 이용한 이중 에너지 X 선 흡수 영상 잡음 제거)

  • Kim, Hyungil;Eom, Wonyong;Kim, Dae Hoe;Ro, Yong Man
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2012.04a
    • /
    • pp.369-372
    • /
    • 2012
  • 대사성 골 질환인 골다공증(Osteoporosis)의 조기 진단을 위한 골 밀도를 측정하는 방법이 최근 연구되고 있다. 골 밀도 영상은 이중 에너지 X 선 흡수법에 의해 측정되는데, 영상에 존재하는 잡음은 뼈 영역 추출과 골 밀도 계산에 어려움을 주고 있다. 따라서 본 논문에서는 최근 신호처리 분야에서 폭넓게 사용되고 있는 sparse 표현을 도입하여 X 선 영상의 잡음을 제거하는 방법을 제안한다. 실험을 통해 제안한 잡음 제거 방법의 결과가 기존의 방법에 비해 개선됨을 MSR(Mean to Standard deviation Ratio)과 CNR(Contrast to Noise Ratio)을 통해 확인하였다.

Three-dimensional measurement of electron temperature and plasma density in coplanar AC plasma display panels (면방전 AC-PDP에서의 전자온도와 플라스마 밀도의 3차원 진단)

  • Jeong, S.H.;Moon, M.W.;Park, W.B.;Lee, J.H.;Lim, J.E.;Lee, H.J.;Son, C.G.;Lee, S.B.;Yoo, N.L.;Han, Y.G.;Oh, P.Y.;Ko, B.D.;Jeoung, J.M.;Seo, Yoon-Ho;Cho, Guang-Sup;Choi, Eun-Ha
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.139-141
    • /
    • 2005
  • 이번 실험에서는 변방전형 교류 PDP에서의 3차원적인 전자온도와 이온밀도의 측정을 마이크로 랑뮈르 탐침법을 통해 실험적으로 연구하였다. 스테핑 모터에 연결된 마이크로 랑뮈르 탐침은 20um씩 움직이며 탐침에 인가하는 플러스와 마이너스의 직류전압을 통해 I-V곡선을 구할 수 있고 이를 통해서 전자온도와 플라스마 밀도를 구할 수 있다. Ne+Xe(4%) 200Torr의 혼합가스에서 전극의 테두리를 따라(X축) 전자온도 및 플라스마 밀도를 측정한 결과 중앙지점에서와 전극의 경계지역에서 이온밀도는 $7.69{\sim}11.1{\times}10^{11}cm^{-3}$ 까지 측정되었다. 또한 전자온도는 플라스마 밀도와 균형적인 관계에 있다는 것은 주목할 만하다. 전자온도는 전극 사이의 중심에서 가장 적게 1.3 ~ 3.15eV까지 측정되었다. Y축으로 측정했을 경우 이온 밀도와 전자온도는 전극 갭 중앙에서부터 약 80um 떨어진 지점에서 서로 교차하며 증가 및 감소였으며 이온밀도는 $8.3{\sim}11.1{\times}10^{11}cm^{-3}$로 측정되었고 전자온도는 이와 균형적인 관계를 가지고 1.2~1.6eV로 측정되었다. 또한 이러한 특성은 AC PDP 에서 나타나는 줄무늬 현상과 관련이 있는 것으로 보인다. Z축으로 측정했을 경우 약 125um높이에서 가장 높게 측정되었으며 $1.1{\times}10^{12}cm^{-3}$정도로 측정되었다.

  • PDF

A Study on Dielectrical Constant under Ground Conditions (지반조건에 따른 유전상수 변화에 관한 연구)

  • Cho, Jinwoo;Cho, Wonbeom;Kim, Jinman;Choi, Bonghyuck
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.12
    • /
    • pp.17-25
    • /
    • 2012
  • In this study, dielectrical constant of the ground was measured using TDR method and correlated with water contents and density of ground. In order to evaluate the applicability as a cavity exploration, model experiments were carried out to analyze the effects of cavity size on the dielectrical constant. Test result indicated that dielectrical constant of the ground tended to linearly increase with the increase in water contents and density, which can be represented in a certain relational expression. Also, the dielectrical constant of ground varied sensitively with the cavity size of ground. The results conclude that the dielectrical constant, water contents and density of the ground proved to have a correlation among them, and the dielectrical constant is expected to be a basic data on cavity exploration.

정밀단독측위를 이용한 저궤도위성의 궤도결정 정밀도 분석

  • Choe, Jong-Yeon;Lee, Sang-Jeong
    • Bulletin of the Korean Space Science Society
    • /
    • 2011.04a
    • /
    • pp.25.2-25.2
    • /
    • 2011
  • 저궤도위성의 정밀궤도결정은 GPS 위성과 수신기의 시계 공통오차를 제거하기 위해 이중 차분하는 방법으로 요구된 위치 정밀도를 충족시켜왔다. 그러나 빠른 속도로 지구를 회전하는 저궤도위성의 정밀궤도결정에 있어 이러한 이중 차분방법은 지구상에 광범위하게 분포된 지상 IGS 망 처리에 많은 계산 부담을 안고 있다. 그리고 지상 측지뿐만 아니라 저궤도위성을 이용한 기상관측 또는 긴급한 영상 처리 응용분야에서도 고정밀도 준실시간(Near Real Time-NRT) 처리가 요구되고 있다. 고정밀 준실시간 정밀궤도결정을 위한 대안은 이중주파수 GPS 수신기으로 IGS에서 제공되는 정밀궤도력을 갖고 고정밀 단독측위가 가능한 정밀단독측위(precise point positioning) 기법으로 상대측위와 버금가는 위치 정밀도를 얻을 수 있다. 다목적실용위성 5호는 고정밀 합성 레이더 영상 처리를 위해서 요구되는 20 cm 위성 위치 정밀도를 만족시키고, 대기 기상관측을 위해 GPS 전파 엄폐 측정값 수집을 목적으로 고정밀 이중주파수 GPS 수신기(Integrated GPS and Occultation Receiver, IGOR)를 탑재하고 있다. 이 논문에서는 IGOR의 이전 제품인 Blackjack 수신기를 탑재한 GRACE 위성의 실제 GPS 데이터를 사용하여 대략 3 ~ 5cm의 위치 정밀도를 얻었다. 준실시간 정밀궤도결정에서 정밀도 손실없이 궤도결정 처리 지연시간(latency)을 줄이는 것이 중요하다. 이 지연시간은 GPS 측정값의 양에 따라 크게 좌우되기에 GPS 측정값 샘플링 주기를 10초에서 640초까지 변화시켜가면서 정밀도를 분석한 결과, 위치 정밀도 손실없이도 궤도결정처리 지연시간을 단축시킬 수 있음을 제시하고 있다.

  • PDF

Analysis of the Physical Properties of Ground before and after Low Flowing Grouting (저유동성 그라우팅 시공전후 지반의 물성변화 분석)

  • Seo, Seok-Hyun;Lee, Jung-Sang;Kang, Won-Dong;Jung, Euiyoup
    • Journal of the Korean Geosynthetics Society
    • /
    • v.18 no.4
    • /
    • pp.115-127
    • /
    • 2019
  • The low-flow grouting injection technique, the target construction method for this study, is a method of pouring mortar into the ground by non-emission replacement principle, which can be expected to increase the density of the ground, and, in some cases, be used as a base file using the strength of the high injection solids, along with low noise, low pollution, and high durability. To verify that the dynamic characteristics of the ground are improved by the low-flow injection technique, the test work was conducted on the site and physical tests were performed, and the quality of the improvement formed in the ground was verified through the indoor test on the core and core recovery rate was analyzed. The density logs test layer calculated the volume density of the ground layer by using the Compton scattering of gamma-rays, and the sonic logs was tested on the ground around the drill hole using a detector consisting of sonar and receiver devices inside the drill hole. As a result of the measurement of the change in physical properties (density and sonic logs) before and after grouting, both properties were basically increased after infusion of grout agent. However, the variation in density increase was greater than the increase in speed after grouting, and the ground density measurement method was thought to be effective in measuring the fill effect of the filler. Strength and core recovery rates were measured from specimens taken after the age of 28 days, and the results of the test results of the diffusion and strength test of the improved products were verified to satisfy the design criteria, thereby satisfying the seismic performance reinforcement.

영구 자석을 이용한 다수 헬리콘 방전의 특성연구

  • An, Sang-Hyeok;Yu, Dae-Ho;Jang, Hong-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.111-111
    • /
    • 2010
  • 헬리콘 플라즈마는 자기장을 이용하여 높은 전자밀도를 가지게 하는 플라즈마 소스이다. 이러한 장점에도 불구하고, 전자석의 크기 때문에 설치가 어렵고, 전자석을 작동시키기 위해 추가 파워에 대한 추가 비용이 필요하며, 플라즈마의 균일도가 좋지 않아 공정에서는 많이 사용되지 못하였다. 이러한 난점은 UCLA의 Chen이 영구자석을 이용한 새로운 개념의 소스를 개발함으로써 풀릴 수 있다. 이 소스는 헬리콘 플라즈마의 높은 저항을 이용하여 여러 개의 헬리콘소스를 병렬로 연결이 가능하게끔 한다. 본 연구에서는 우선 Helic Code를 이용하여 밀도에 따른 헬리콘 플라즈마의 실저항을 계산해 보았다. 계산된 실저항값을 바탕으로, 한 개의 헬리콘 소스를 방전하여 헬리콘 플라즈마의 밀도와 전자온도 등 내부 파라미터 및 저항과 페이즈값 등 외부 파라미터들을 측정하여 계산된 결과와 비교해 보았다. 대면적화에 적합한 플라즈마 소스로써의 가능성을 알아보기 위해, 아르곤가스를 이용한 4개의 튜브로 병렬 방전을 시행해 보았다. Langmuir Probe를 이용하여 측정된 전자밀도를 통해 ICP에서 헬리콘 mode로의 전이 및 균일도를 측정하였다. 측정된 결과로부터, 입력된 파워가 플라즈마에 효과적으로 전달되기 위한 방법을 제시하고, 압력에 따른 헬리콘 mode의 전자밀도 경향성을 통해 어떤 범위에서 헬리콘 방전이 가능한지 알아보았다.

  • PDF

Investigation of Proton Irradiated Effect on n, p type Silicon by Positron Annihilation Method (양전자 소멸 측정에 의한 n, p형 실리콘 구조 특성)

  • Lee, C.Y.
    • Journal of the Korean Vacuum Society
    • /
    • v.21 no.5
    • /
    • pp.225-232
    • /
    • 2012
  • It is described that the proton beam induceds micro-size defects and electronic deep levels in n or p type single crystal silicon. Positron lifetime and Coincidence Doppler Broadening Positron Annihilation Spectroscopy were applied to study of characteristics of p type and n type silicon samples. In this investigation the numerical analysis of the Doppler spectra was employed to the determination of the shape parameter, S, defined as the ratio between the amount of counts in a central portion of the spectrum and the total counts of whole spectrum. The samples were exposed by 3.98 MeV proton beams ranging between 0 to ${\sim}10^{14}$ particles. The S-parameter values strongly depend on the irradiated proton beam, that indicated the defects generate more. Positron lifetime shows that positrons trapped in vacancies and lifetime ${\tau}_2$ increased according to proton irradiation.