• Title/Summary/Keyword: 미진동

Search Result 86, Processing Time 0.032 seconds

PZT stack actuator-based hybrid mount system for mitigating micro-vibration of vibration isolation table (제진 테이블의 미진동 저감을 위한 PZT stack 가력기 기반 복합형 마운트 시스템)

  • Moon, Yeong-Jong;Jang, Dong-Doo;Moon, Seok-Jun;Choi, Sang-Min;Jung, Hyung-Jo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.292-298
    • /
    • 2009
  • This paper investigates the control performance of the proposed hybrid mount system for vibration isolation table. The hybrid mount system consists of an air spring as a passive device and a PZT stack actuator as an active device in series. The feasibility of the PZT stack actuator as an active actuator was examined through the simple experiments. After that, a series of numerical simulations were carried out to evaluate the control performance of the proposed hybrid mount system. The equations of motion of the table with a set of hybrid mount systems consisting of four devices are derived. The air spring is considered as a 1 spring and 1 dashpot elements, and PID control algorithm is adopted to estimate the control force. The results of the numerical simulations presents that the proposed hybrid mount system could be the promising control system for vibration isolation table.

  • PDF

A Study on the Measurement of Natural Frequency for Seismic Design of High Rise Buildings (고층건물의 내진설계를 위한 고유진동수 측정에 관한 연구)

  • Kim, Dong-Baek;Lee, Byeong-Hoon;Lee, In-Duk;Lee, Kwang-Jae
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2015.11a
    • /
    • pp.127-129
    • /
    • 2015
  • 최근 도심의 건물들은 수요자의 요구에 따라 평면이 다양화 되어가고 토지의 효율을 높이기 위하여 초고층화 되어가는 경향이 있다. 심지어 전통적인 공동주택의 개념으로 지어지는 아파트도 그 높이가 100m를 상회하는 경우가 대부분이다. 현재 국내의 구조설계 시 구조물의 동적특성 요소를 반영하는 고유 진동수는 주로 미국의 지진자료를 바탕으로 계산되게 되어있으며, 기존 연구결과 실측결과가 상당한 차이를 보이고 있어 이에 대한 검토가 요구되고 있다. 이에 본 연구에서는 내진설계의 기본이 되는 건물의 고유주기를 측정하고 내진성능을 평가하여, 보다 경제적인 내진설계 방안에 대한 제시하고자 한다. 또한, 벽식구조건물의 경우 구조설계 기준에서 제시하는 지진하중을 산정할 때, 실무자들이 구조형식을 선택하기가 곤란하여 어떤 주기산정 식을 사용해야 할지 혼란스러워 하는 경우가 많으므로, 기타 골조 식과 전단벽 식을 고려하는 경우를 구조물의 상시 미진동을 측정하여 고유 진동수 및 고유 주기를 비교하여 제시하였다. 연구결과 기타 골조 식에 의해 계산된 값은 매우 보수적으로 나타나서 이에 대한 검토도 필요하다고 사료된다.

  • PDF

A Study on the Dynamic Design of Structure for Sub-Vibration Control of Precision Measuring System (극 초정밀 측정시스템의 미진동제어를 위한 구조물의 동적 설계에 관한 연구)

  • 김강부;김현식;전종균;김기현
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.863-868
    • /
    • 2001
  • It is necessary to design th anti-vibration system of precision machinery for a sound operation and a quality assurance. However, in general. the allowable vibration limit is not well known. In the paper, the vibration criteria for foundation of vibration sensitive machinery is proposed and anti-vibration system is designed by using vibration measurement results of foundation. Also, the F.E. analysis is performed to verify the effectiveness of a designed anti-vibration system and to determine allowable dynamic load of machinery

  • PDF

A Study on the Optimal Operation of Step Voltage Regulator(SVR) in the Distribution Feeders(2) (고압배전선로의 선로전압조정장치(SVR)의 최적운용에 관한 연구(2))

  • Lee, Eun-Mi;Rho, Dae-Seok;Kim, Mi-Young;Kim, Jae-On;Choi, Jae-Seok;Park, Chang-Ho;Kim, Eung-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.27-29
    • /
    • 2003
  • 최근, 배전계통의 고압 배전선로의 전압강하가 5%를 초과하는 장거리 선로에 대한 효율적인 전압관리가 미흡한 상태이며, 배전선로의 전압을 제어하기 설치하는 선로 전압조정장치(Step Voltage Regulator : SVR)의 잦은 고장 및 설치공간 과다점유로 전압조정장치의 설치 사용실적이 미진하고, 동 기기의 운용 및 설치기준에 정립이 시급한 실정이다. 따라서 전압강하 5% 초과 지역에 대한 효율적인 전압관리 개선방안을 강구하기 위하여, 현재 배전사업소에 도입, 설치되고 있는 전압조정 장치(SVR)의 운용기준 제정은 물론, 적정용량 및 최적 위치선정에 대한 방안을 제시하는 연구가 필요하다.

  • PDF

Application of Smart Isolation Platform for Microvibration Control of High-Tech Industry Facilities (첨단기술산업 시설물의 미진동제어를 위한 스마트 면진플랫폼의 적용)

  • Kim, Hyun-Su;Kang, Joo-Won;Kim, Young-Sik
    • Journal of Korean Association for Spatial Structures
    • /
    • v.14 no.2
    • /
    • pp.87-94
    • /
    • 2014
  • In this study, a smart isolation platform has been developed for control of microvibration of high-technology facilities, such as semi-conductor plants and TFT-LCD plants. Previously, microvibration control performance of a smart base isolation system has been investigated. This study compared microvibration control performance of a smart isolation platform with that of conventional base isolation and fixed base. For this purpose, train-induced ground acceleration is used for time history analysis. An MR damper was used to compose a smart isolation platform. A fuzzy logic controller was used as a control algorithm and it was optimized by a multi-objective genetic algorithm. Numerical analysis shows that a smart isolation platform can effectively control microvibration of a high-technology facility subjected to train-induced excitation compared with other models.

안내-행자부, 지방계약민원 종합상담센타 개관

  • Korea Mechanical Construction Contractors Association
    • 월간 기계설비
    • /
    • no.2 s.199
    • /
    • pp.81-81
    • /
    • 2007
  • 행정자치부(장관 박명재)가 지역예산을 집행하는 계약과정에서 발생하는 문제의 해결을 돕기 위해 마포구 공덕동에 소재한 한국지방재정회관에서「지방계약민원 종합상담센타」를 개설, 지난 1월 22일부터 민원상담서비스에 들어갔다. 이 센타는 2006년‘지방자치단체를 당사자로 하는 계약에 관한 법령’시행 이후 폭발적으로 증가하는 민원상담을 소화하는 한편, 서비스의 질을 높여 체계적·능동적인 민원서비스를 위해 개설 됐으며 △상담신청 → 1차상담서비스 → 진행상황 파악 → 미진한부분에 대한 사후 서비스 → 수범사례 전파의 순으로 서비스가 진행된다.「지방계약민원 종합상담센타」는 앞으로 자치단체, 교육행정기관, 건설업체 등에 대한 신속하고 품질 높은 민원상담서를 제공, 고객만족을 확대하고 제도적 건의사항이나 문제점을 즉시 파악해 정책에 반영할 계획이다. 한편 이날 현판 제막식에는 김경회 대한설비건설협회 상임이사를 비롯한 건설단체 임원 및 지방자치단체 시·도 계약담당 사무관, 시·도 교육청 계약담당 사무관, 행자부 산하기관 임원 등이 참석했다.

  • PDF

A Study on Safety Blasting Design with Blast Vibration Analysis Urban Area (도심지 미진동 제어 발파에서 진동분석을 통한 안전발파설계에 관한 연구)

  • 안명석;박종남;배상근
    • Explosives and Blasting
    • /
    • v.17 no.2
    • /
    • pp.36-44
    • /
    • 1999
  • A study was made on the design of the prediction model concerning blasting vibration in a constraction site, Namgu, Daegu City. The geology in this area consists of hornfels of shale and mud underlain by quartize, of which the main strike of the geological structure is NW direction. Measurements were carried out on the top of the wall concrete water storage tank, which is burried in the ground earth. The attenuation due to the vertical wall of the concrete structure may be experted because of spherical divergency at the bottom corner of the wall by the Huygens principle. For design of blasting prediction model, thus among scaled distance(SD) may be preferable to use in the regression model, since they represents most likely the average ground condition. Judging from the regression results, the cube root method may be more suitable for this area. The SD values for the maximum allowable vibration velocity of 0.5 cm/s, in this area are 22.5, 28.0 and 30.6 for the significance level of 50%, 95% and 99%, respectively.

  • PDF

A Experimental Study of Rock Fragmentation with Plasma Method (플라즈마 공법에 의한 암석파괴의 실험적 연구)

  • Yoon, Ji-Son;Kim, Sang-Hoon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.4 no.1
    • /
    • pp.27-35
    • /
    • 2002
  • For the excavation of the rock, blast method is put into operation in most of the construction site in Korea. In comparison to other methods of excavation, blast method has many merits such as improvement in efficiency in operation, reducement of operation period, and etc. However, blast operation also creates much loss due to the blast vibration, noise, and fly rocks. Thus, in this study, we have examined main features, rock fragmentation effect and the application of plasma method the one of shallow vibration method. In this study, the attenuation exponent of blast method operated in the site was 1.39~1.40 and that of the plasma method was analysed to be 1.45~2.23. From the location where the distance between excavation location and observation location was over 15 m, most of excavation vibration were measured to be less than 0.2 kine(cm/sec), which is also the allowed standard value of sensitive buildings, such as cultural assets and computer facilities. According to the result of FFT(Fast Fourier Transform) analysis, the frequency measured through blast method in this site was 30~50 Hz and the frequency of plasma method ranges in between 30~130 Hz.

  • PDF

A Study on Experimental Vibration pre-estimation Techniques of Structure (구조물의 실험적 진동예측 기술에 관한 연구)

  • 이홍기;권형오
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1992.10a
    • /
    • pp.48-52
    • /
    • 1992
  • 진동원을 가진 장비를 임의의 구조물에 설치할 경우 관심이 되는 문제는 구 조물의 임의의 위치에서의 진동 수준을 추정하는 일이다. 특히 정밀장비를 다루는 반도체 공장에서 크린룸이나, 정밀측정, 분석 실험실등 미진동을 제 어해야 하는 분야에서는 더욱 그 필요성이 대두되고 있다. 진동제어가 필요 한 공간에 대한 진동수준의 예측이 가능할 경우 진동윈이나 수진점(active and passive type)방진에서 최적화된 전달률(transmissibility)을 명확히 결정 할 수 있어 설계와 시행오차를 최소화 할 수 있다. 그러나 이러한 실제문제 를 다룰 경우 대부분 진동제어 구조물은 복잡하고 설치 운용되는 장비들은 대형, 복합장비가 사용되는 것이 일반적이고 수행기간도 여러가지 공정상 단 시간에 이루어져야 하는 현실적인 어려움이 있다. 진동제어가 필요한 구조물 에 대한 임의의 공간에서 진동수준을 신속하고 정확하게 예측하기 위해서는 최소한 두 가지 정보만이라도 명확히 해야 한다. 하나는 장비의 주파수별 정 확한 가진력의 산정이고 다른 하나는 장비가 설치되고 진동제어가 필요한 구조물에 대한 동적특성(dynamic property)이다. 가진력에 대한 정보는 일반 적으로 장비제작사가 제시하는 것이 원칙이나 그렇지 못할 경우 구조해석 기술자(structure engineer)가 해석적으로 추정하거나 또는 명확히 가진 특성 을 알지 못하는 복잡한 장비는 실험적으로 결정해야 한다. 구조물의 동적 특 성을 나타내는 모빌리티(mobility)를 구하는 방법은 해석적인 방법과 실험적 인 방법이 있으나 복합재료, 복잡한 구조형태나, 지지조건, 다양한 결합부의 동적 특성을 정의하여 해석적으로 정확히 해결하기에는 어려움이 있다. 이러 한 제한조건을 손쉽게 해결하는 방법은 실 구조물에 대한 동적실험(dynamic test)을 통하여 단기간에 동적특성을 결정하고 SDM(structure dynamic modification)이나 FRS(force response simulation)를 수행하여 임의의 좌표 공간에 대한 진동수준을 해석적으로 예측할 뿐만 아니라 구조물의 진동제어 를 위한 동적인자를 변경시킬 수 있는 정보를 제공하며 장비를 방진할 경우 신뢰성 있는 전달률을 결정할 수 있다. 실험적으로 철교, 교량이나 건물의 철골구조 및 2층 바닥 등 대,중형의 복잡한 구조물에 대항 동특성을 나타내 는 모빌리티를 결정할 경우 충격 가진 실험이 사용되는 실험장비 측면에서 나 실험을 수행하는 과정이 대체적으로 간편하다. 그러나 이 경우 대상 구조 물을 충분히 가진시킬수 있는 용량의 대형 충격기(large impact hammer)가 필요하게 된다. 이러한 동적실험은 약 길이 61m, 폭 16m의 4경간 교량에 대 하여 동적실험을 수행하여 가능성을 확인하였다. 여기서는 실험실 수준의 평 판모델을 제작하고 실제 현장에서 이루어질 수 있는 진동제어 구조물에 대 한 동적실험 및 FRS를 수행하는 과정과 동일하게 따름으로써 실제 발생할 수 있는 오차나 error를 실험실내의 차원에서 파악하여 진동원을 있는 구조 물에 대한 진동제어기술을 보유하고자 한다.

  • PDF

The Shear Wave Velocity Analysis using Passive Method MASW in the Center of the Metropolis, Gyeongsan (Passive Method MASW 방법을 이용한 경산시 도심구간에서의 전단파 속도 분석)

  • Lee, Hong-Gyu;Kim, Woo-Hyuk;Jang, Seung-Ik;Lee, Seog-Kyu
    • The Journal of Engineering Geology
    • /
    • v.17 no.4
    • /
    • pp.511-516
    • /
    • 2007
  • Active method MASW(Multi channel Analysis of Surface Waves), which is one of the surface wave exploration methods, has the difficulties to supply enough shear wave velocity log, caused by short spread length and lack of low frequency energy. To make up this defect, the passive method MASW survey is taked and analysised in Daeku subway construction site, Jungpyung-dong Gyeongsan city. The passive method MASW using the microtremor, improve the quality of the overtone record by applying the azimuth correction caused offline sources. And combing with active overtone record which is acquired by same geometry has the benefits of improve shallow depth resolution and extend possible investigation depth. To take the optimized acquisition parameters, the 2m, 4m, and 6m geophone spacing is tested. And 2m spacing overtone image could make the reliable shear wave velocity log.