• Title/Summary/Keyword: 미연 탄소

Search Result 113, Processing Time 0.025 seconds

Boiler Performance Characteristics Change by UC Contents Increase for Coal Fired Power Plant (석탄연소 화력발전소에서 미연탄소분 농도 증가가 보일러 성능에 미치는 영향에 관한 연구)

  • Kim, Taehyung;Park, Byungchul
    • 한국연소학회:학술대회논문집
    • /
    • 2015.12a
    • /
    • pp.99-102
    • /
    • 2015
  • To operate coal fired power plant efficiently is considered unburned carbon as important factor. But, unburned carbon contents change does not have an impact on Boiler performance simultaneously. we evaluated that unburned carbon contents change had an little influence on unburned carbon loss change for performance side at a real power plant.

  • PDF

Study on the Properties of Surface Treatmented Fly Ash using Arc Discharge (아크방전을 이용해 표면개질 된 플라이애시의 특성에 관한 연구)

  • Park, sun-gyu;Kim, sun-a;Kim, hyeon-sung
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2018.05a
    • /
    • pp.273-274
    • /
    • 2018
  • 플라이애시를 콘크리트의 혼화재로서 사용하기 위해서는 미연탄소 제거 및 알칼리 자극제의 첨가가 요구된다. 이러한 문제점을 해결하기 위해 현재까지 플라즈마를 이용한 플라이애시의 표면개질에 관한 연구가 진행되었으나, 플라즈마는 오존을 생성하는 문제점을 지니고 있다. 따라서 본 연구에서는 이와 같은 문제점을 해결하고자 아크방전을 이용해 플라이애시의 표면을 개질하는 연구를 진행하였다.

  • PDF

A Study on Heat and Mass Balance in a Coal Gasifier (석탄 가스화기 열 및 물질정산에 관한 연구)

  • Kim, Bong-Keun;Yoo, Jeong-Seok;Kim, You-Seok
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.424-428
    • /
    • 2007
  • In the current most tool using heat and mass balance in a coal gasifier is dependent on commercial code such as STANJAN, CHEMKIN. However, in order to keep the self-reliance technology, it is necessary to develop the original design tool available for comprehension and analysis on the spot. So in this study, its own heat and mass balance program is developed on the assumption that the process in a coal gasifier is adiabatic and quasi-equilibrium. The mass balance is calculated by using the chemical equilibrium principle. Also the heat and mass balance according to main operating factors such as temperature, pressure and O2/Coal ratio, was carried in this tool. This heat and mass balance was verified on the basis of the results simulated in STANJAN, commercial codes using similar logic.

  • PDF

Low NOx Combustors in a Industrial Gas Turbine (산업용 가스터빈의 저NOx 연소기)

  • 신동신
    • Journal of the KSME
    • /
    • v.34 no.12
    • /
    • pp.929-939
    • /
    • 1994
  • 최근 환경문제와 관련하여 정제된 석유 연료가 아닌 천연가스와 같은 연료의 사용이 증가하면서 산업용 가스터빈의 연소기술에 대한 관심이 집중되고 있다. 가스터빈 연소로 생성되는, 환경을 위협하는 오염물은 연기, 수증기, 일산화탄소(CO), 미연 탄화수소, $NO_{x}$, $SO_{x}$ 등이 있다. 수증기 및 일산화탄소는 지구 온실화에 영향을 미치고 있으나 그다지 심각한 정도는 아 니며, $SO_{x}$는 독성이 있으나 연료 정제시 제거되어질 수 있다. $NO_{x}$는 지구의 오 존층을 파괴하여 생태계를 위협하기 때문에 오염 배출물중 가장 심각하게 고려되어지고 있다. 미국에서는 법으로 산업용 가스터빈의 $NO_{x}$의 양을 규제하고 있는데 15% 산소배출농도에 대하여 1984년에 75ppm에서 1993년에 30ppm으로 낮추어 규제하고 있다. 일본도 미국과 비슷한 수준으로 규제하고 있으며, 따라서 최근의 가스터빈 연소기술은 저 $NO_{x}$연소기에 대한 것으로 저$NO_{x}$연소에 관한 개론 및 가스터빈 연소기의 저$NO_{x}$화 방법, 그리고 미 국과 일본의 최근의 저$NO_{x}$연소기 개발동향에 대하여 다루고자 한다.

  • PDF

Characteristics of UBC and NOx Emission in Air Staging Combustion (공기 다단 연소 기법 적용에 따른 미연탄소분 및 질소산화물 배출특성)

  • Kim, Jeong Woo;Lim, Ho;Go, Young Gun;Jeon, Chung Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.10
    • /
    • pp.637-644
    • /
    • 2016
  • The purpose of this study is to understand the characteristics of unburned carbon (UBC) and NOx emissions for pulverized coal when air staging combustion is applied. A two-staged drop tube furnace capable of applying air staging combustion was designed and installed. The combustion of sub-bituminous (Tanito) has been investigated. UBC and the NOx concentration were measured under various temperatures and stoichiometric ratios in unstaged and staged combustion. As a result, UBC decreased and the NOx concentration increased with an increase in stoichiometric ratio and temperature. In particular, the NOx reduction mechanism was activated when the temperature in the fuel rich zone increased. Both UBC and the NOx concentration decreased as the temperature increased in the fuel rich zone. A high NOx reduction effect was obtained, compared to the UBC increase, when the air staging technique was applied.

Air Fuel Ratio Determination Method for Alternative Fuel Based on Carbon Balance and Linear Equation (탄소 균형과 1차식에 의한 대체 연료의 공연비 산정법)

  • Lee, Jae-Won;Kwon, Soon-Tae;Park, Chan-Jun;Ohm, In-Young
    • Journal of Energy Engineering
    • /
    • v.17 no.4
    • /
    • pp.182-188
    • /
    • 2008
  • This paper is to compare the carbon-balanced and liner air-fuel ratio determination methods for alternative fuels. In the previous work, expansion of Eltinge chart, unburned hydrocarbon compensation, comparison of the results from various methods were discussed. It has been also concluded that Eltinge method might be regarded as the most general equation of AFR determination among the existing ones. In the recent years, however, increasing demand for the environmental preservation, including global warming-up protection, and energy conservation lead to introduce the alternative fuel to the internal combustion engine. Therefore, the exact calculations of AFR for these fuels are needed. Especially, for the fuel that contains oxygen, all AFR calculation equations except Eltinge have to be re-formulated. In this paper, the AFR for alternative fuel were calculated by re-formulated carbon balance, accuracy of which was already confirmed, and linear equations, which are newly proposed by statistical method for each fuel. The results show that AFRs based on carbon balance have a little more error compared with gasoline, however, the accuracy is enough for this formula to apply to various fuel. The proposed linear equation also have excellent accuracy below $\lambda=1.2$.

Empirical Study on water wall tube corrosion mechanism for Tangential type coal fired power plant boiler (석탄화력발전소 보일러의 수냉벽튜브 부식 메카니즘에 대한 실증적 고찰)

  • Baek, Sehyun;Kim, HyunHee;Park, Hoyoung;Ko, SungHo
    • Journal of Energy Engineering
    • /
    • v.23 no.4
    • /
    • pp.49-55
    • /
    • 2014
  • In this study, boiler tube thickness measurement and numerical analysis were conducted for standard 500MW coal-fired power plant in order to research the mechanism of tangential-fired boiler corrosion empirically. The most dominant corrosion mechanism of tangential-fired boiler waterwall was corrosion by sulfur contained in the unburned carbon. And the secondary mechanism was $H_2S$ gas corrosion at localized reducing atmosphere. It is required to decrease the air-stage combustion operation in order to mitigate the waterwall tube corrosion. Also stringent coal pulverization quality control and reinforcing work for corrosion susceptible area such as anti-corrosion coatings is required

A Study on the Function of Organic Admixture in Fly Ash Substituting Fresh Concrete (플라이애쉬를 혼합(混合)한 굳지않은 콘크리트에 있어서 유기혼화제(有機混和劑)의 기능(機能)에 관한 연구(研究))

  • Moon, Han Young;Sea, Joung Woo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.8 no.2
    • /
    • pp.117-124
    • /
    • 1988
  • From the test results of the adsorption characteristics of AE admixture, it was shown that the adsorption of AE admixture on fly ash was mearly completed in 30 minutes and the higher was ignition loss, the larger the quantity of saturation adsorption. Because most of the ignition loss of the fly ash was due to the unburned carbon, it could be said that the unburned carbon is the main reason of reduction of air content in AE concrete. On the other hand, in the case of superplasticizer, the amount of saturation adsorption in fly ash was lower than in cement and the same result was obtained in the dispersive effect. But, when using superplasticizer in fly ash substituting concrete, the fludity in the concrete was not decreased.

  • PDF

Effect of activated carbon on bloating properties of artificial lightweight aggregates containing coal reject ash and bottom ash (석탄 잔사회 및 바닥재가 포함된 인공경량골재의 발포특성에 미치는 활성탄소의 영향)

  • Kang, Min A;Kang, Seunggu
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.23 no.4
    • /
    • pp.201-206
    • /
    • 2013
  • The coal bottom ash and reject ash discharged from a coal-fired power plant are difficult to recycle so most of them are mainly landfill-disposed. In this study, the artificial aggregate were produced using reject ash, bottom ash and dredged soil emitted from the coal-fired power plant in Korea and the effect of experimental factors on the bloating behavior and the properties of the aggregates were analyzed. In particular, a lot of unburned carbon in the reject ash was removed by calcination and the activated carbon was added to batch powders then the dependence of those process upon bloating properties of artificial aggregate were investigated. For this purpose, the specific gravity and water absorption values of artificial aggregates were investigated in conjunction with microstructural observations. This study could contribute to increase the recycling rate of the reject ash.

Manufacture of Adsorbent from Fly-ash and Anthracite (비산회재 및 무연탄을 원료로 한 흡착제 제조)

  • Baek, Il-Hyung;Bin, Hyun-Suk;Roo, Wan-Ho;Kim, Tae-Young;Min, Byoung-Moo
    • Applied Chemistry for Engineering
    • /
    • v.10 no.4
    • /
    • pp.543-547
    • /
    • 1999
  • The utilization of fly-ash containing high levels of the unburned carbon was investigated. In this study adsorbents were manufactured from fly-ash ad a raw material and the manufactured adsorbents were applied to the waste-water treatment including heavy metals. Varying the anthracite(Jangsung coal) content, three types of pellet were made. The carbon content of pellet increased appreciably upon the addition of anthracite. After carbonization and activation using the pellets, adsorbents showed following characteristics; the range of hardness was between 85% and 96%, iodine number was from 100 mg/g to 300 mg/g. In proportion to the anthracite addition, hardness and iodine number increased. Through the adsorption experiments of heavy metals, removal efficiencies of Pb and Cr by manufactured adsorbents were over 90%. In case of fly-ash, removal efficiencies of Pb and Cr were 31.5% and 5.6% respectively. The reason why removal capacities of manufactured adsorbents were higher than fly-ash was postulated that adsorption capability was improved by unburned carbon and $SiO_2$ which included in fly-ash during steam activation.

  • PDF