• Title/Summary/Keyword: 미소신호 안정도

Search Result 43, Processing Time 0.036 seconds

A Study on the Effect of Controllers in Small Signal Stability of Power Systems (전력계통의 미소신호안정도에 미치는 제어기의 영향에 관한 연구)

  • 권세혁;김덕영
    • Journal of Energy Engineering
    • /
    • v.5 no.1
    • /
    • pp.72-79
    • /
    • 1996
  • The effect of controllers-Exciter, Power System Stabilizer, and Static Var Compensator-in one machine infinite bus system is investigated in this paper. The structure of generator state matrix with controllers is represented, while the Static Var Compensator is installed in generator terminal bus. Eigen-value analysis is performed and the effects of controllers to the dominant eigenvalue in one machine infinite bus system are represented by first order eigenvalue sensitivity coefficients while the operating conditions of the system are varied. Optimization of controller parameters using first order eigenvalue sensitivity coefficients is performed by the Simplex Method. It is proved that exciter control is the most efficient method to improve stability of the system and the effect of Static Var Compensator is small, in the case of one machine infinite bus system.

  • PDF

A study of Facts Application in power systems for the small signal Stablity Enhancement (전력계통에서의 유연송전시스템 적용에 의한 미소신호안정도향상)

  • Baik, Seung-Do;Lee, Byong-Jun;Jang, Byong-Hun
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.255-258
    • /
    • 2000
  • The supplementalγ controls of the FACTS are designed for the enhancement of the small signal stability in power system. The designed supplementary controllers using residue are applied to SVC or TCSC for the improving the damping ratio of dominant eigen value in the New England and 39 bus test system as the sample system. The results show the validation of the supplementary controller for the enhancement of the eigenvalues which have the low frequency oscillations with poor damping ratio as the unstable problem in the sample system.

  • PDF

Eigenvalue Perturbation for Controller Parameter and Small Signal Stability Analysis of Large Scale Power Systems (제어기정수에 대한 고유치 PERTURBATION과 대규모 전력계통의 미소신호안정도 해석)

  • Shim, Kwan-Shik;Song, Sung-Gun;Moon, Chae-Ju;Lee, Ki-Young;Nam, Hae-Kon
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.11
    • /
    • pp.577-584
    • /
    • 2002
  • This paper presents a novel approach based on eigenvalue perturbation of augmented matrix(AMEP) to estimate the eigenvalue for variation of controller parameter. AMEP is a useful tool in the analysis and design of large scale power systems containing many different types of exciters, governors and stabilizers. Also, it can be used to find possible sources of instability and to determine the most sensitivity parameters for low frequency oscillation modes. This paper describes the application results of AMEP algorithm with respect to all controller parameter of KEPCO systems. Simulation results for interarea and local mode show that the proposed AMEP algorithm can be used for turning controller parameter, and verifying system data and linear model.

Contingency Analysis of Small Signal Stability for MW Changes (발전량 변화와 미소신호안정도 상정사고 해석)

  • Shim, K.S.;Song, S.G.;Moon, C.J.;Kim, Y.G.;Nam, H.K.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.139-141
    • /
    • 2002
  • This paper describes a new contingency analysis methods for small signal security assessment based on the eigenvalue perturbation. The eigenvalue perturbation with respect to MW changes can be used to find possible sources of the low frequency oscillation, and to select contingency for small signal stability. The proposed algorithm has been successfully tested on the KEPCO systems.

  • PDF

Analysis of Small Signal Stability Considering Voltage Stability (전압안정도를 고려한 미소신호안정도 해석)

  • Kim, D.J.;Moon, Y.H.;Yoon, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.323-326
    • /
    • 2001
  • This paper describes the algorithm which can not only take account of voltage suability but also consider small signal stability. As for voltage stability both CPF and PoC methods are utilized to pinpoint the exact voltage collapse point. Then, using the converged load flow results full system matrix is configured and its eigenvalues are computed. The suggested algorithm is applied to the Two-area system, and verified its usefulness. In addition this paper also deals with the results of analyzing the two-area system in terms of voltage stability and small signal stability.

  • PDF

Small Small Signal Stability Anslysis by AMEP for Controller Parameter (제어기정수에 대한 AMEP와 대규모 전력계통에 미소신호안정도 해석)

  • Shim, K.S.;Song, S.G.;Nam, H.K.;Kim, Y.G.;Moon, C.J.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.112-115
    • /
    • 2001
  • Eigenvalue perturbation theory of augmented system matrix(AMEP) is a useful tool in the analysis and design of large scale power systems. This paper describes the application results of AMEP algorithm with respect to all controller parameter of KEPCO systems. AMEP for interarea and local mode can be used for turning controller parameter, and verifying system data and linear model of controller.

  • PDF

Effect of Load Characteristics in Small-Signal Stability Analysis in Multimachine Power Systems (다기계통의 미소신호안정도해석시 부하특성의 영향)

  • Kwon, Sae-Hyuk;Rho, Kyu-Min;Jang, Kil-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.189-191
    • /
    • 1993
  • A systematic procedure for the elements of system matrix in multimachine systems with loads is suggested for the small-signal stability studies. Synchronous machines are represented by either a two-axis model or classical model. The interrelationship of submatrices of system matrix is investigated. Once elements of one submatrix are determined, they can be used to calculate the elements of the other submatrix. It is illustrated for three machine and nine bus multimachine systems with constant impedance loads, constant MVA load, constant current and power factors.

  • PDF

A Study on Acoustic Emission and Micro Deformation Characteristics During Biaxial Compression Experiments of Underground Opening Damage (이축압축실험을 통한 지하공동 손상시 음향방출 및 미소변형 특성 연구)

  • Min-Jun Kim;Junhyung Choi;Taeyoo Na;Chan Park;Byung-Gon Chae;Eui-Seob Park
    • Tunnel and Underground Space
    • /
    • v.34 no.2
    • /
    • pp.169-184
    • /
    • 2024
  • This study investigates acoustic emission (AE) and micro-deformation characteristics of circular openings through biaxial compression experiments. The experimental results showed a significant increase in the frequency, count, energy, and amplitude of AE signals immediately before damage occurred in the circular opening. The differences in frequency and count between before and after damage initiation were significantly pronounced, indicating suitable factors for identifying damage occurrence in circular openings. The results for digital image correlation (DIC) technique revealed that micro-deformation was concentrated around the openings, as evidenced by the spatial distribution of strain. In addition, spalling was observed at the end of the experiments. The AE and micro-deformation characteristics presented in this study are expected to serve as fundamental data for evaluating the stability of underground openings and boreholes for deep subsurface projects.

Improvement of Microwave Water Surface Current Meter and its Commercialization (전자파표면유속계의 성능개선 및 실용화)

  • Kim, Young-Sung;Lee, Hyun-Seok
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.85-85
    • /
    • 2011
  • 홍수기에 안전하고 정확한 유량측정을 통하여 물관리에 필요한 기초수문자료를 확보하고자 한국수자원공사에서 1993년도부터 홍수유량측정기술 확보를 위한 연구를 시작하였다. 그간의 연구성과를 바탕으로 1999년도에 하천의 유속을 비접촉식으로 측정할 수 있는 홍수용 전자파표면유속계를 개발하여 특허등록하였고 그와 동시에 이의 상품화를 추진하여 2010년도까지 75대를 보급하여 실무에서 이용하고 있다. 이동식인 홍수용 전자파표면유속계를 바탕으로 2001년도에는 고정식 실시간 홍수유량측정측정시스템을 개발하여 특허등록하였고, 이 시제품을 현재 용담 수자원시험유역의 동향지점에서 시험운영하고 있다. 또한, 현장 유량측정실무자들의 홍수용 전자파표면유속계 개선요구에 따라 편각용 전자파표면유속계 시제품을 개발하였으며, 이는 임의의 한 지점에 설치한 한 대의 장비로 좌우 여러 측선의 유속을 동시에 측정할 수 있는 다점 측정기능을 갖도록 성능을 개선하였다. 이에 따라 홍수시 유량측정에 소요되는 시간이 줄어들어 신속하게 유량측정을 완료할 수 있는 계기를 마련하였다. 이와 더불어 유속측정 범위를 확장하여 홍수시의 고유속 뿐만 아니라 0.5 m/s 이하의 저유속까지 측정할 수 있는 범용 전자파표면유속계의 시제품을 추가로 개발하였다. 이 장비는 최저유속 0.03 m/s의 측정을 실내시험을 통하여 입증하였다. 범용 전자파표면유속계는 상품화 시제품의 개발을 목표로 기존 시제품의 현장시험을 통하여 현장적용상의 문제점에 대한 해결에 주력하였다. 첫째, 평갈수용 전자파표면유속계의 사용편의를 개선하기 위하여 소형화 및 경량화를 추진하였고, 이를 위하여 사용주파수를 기존의 10 GHz에서 24 GHz로 변경함으로써 $35{\times}35\;cm$ 크기의 기존안테나를 $22{\times}22\;cm$ 크기로 소형화하였으며 송수신부의 무게는 기존 18 kg에서 3.3 kg으로 혁신적으로 줄이는데 성공하였다. 이를 위하여 안테나는 기존의 반사형안테나에서 도파관슬롯배열안테나로 변경하였다. 둘째, 측정값의 안정화를 위하여 안테나의 특성을 개선하여 부엽(side-lobe) 레벨 30 dB 이하 그리고 전후방비(front-back ratio) 50 dB 이하로 개선하여 안테나가 지향하는 방향 이외의 위치에서 반사되는 불필요한 신호를 줄였다. 또한 적응형 이득제어(adaptive gain control)기법의 채택으로 미소 신호에 대한 안정적 측정 및 과다 신호에 대한 능동적 감쇄를 할 수 있도록 시스템을 구성하여 전 유속범위에 대한 안정적 측정을 가능토록 설계 및 제작하였다. 셋째, 자가점검 기능을 탑재하여 유속측정 전에 기기의 상태에 대한 self test기능을 통하여 측정자가 기기의 상태를 사전에 파악 가능토록함으로써, 기기 오작동에 대한 능동 대처할 수 있도록 하였다. 이외에도 저전력 회로설계를 통하여 배터리 사용시간을 확장하였고, 기존의 전자파표면유속계가 가지고 있던 방습 및 방수에도 내성을 갖는 제품으로 설계하였으며 스마트기기를 이용한 무선측정 및 세련된 디자인 등 사용자의 요구사항을 충분히 반영하였다.

  • PDF

Flow Signal Characteristics of Small Scale Electromagnetic Flowmeter in Low Conductivity Fluid Measurement (저전도율 유체 측정에서 소형 전자기유량계의 신호 특성)

  • Lim, Ki Won;Jung, Sung Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.9
    • /
    • pp.613-620
    • /
    • 2016
  • In order to scrutinize the fluid conductivity effects on the electromagnetic flowmeter(EMF) characteristics, a small scale EMF was designed and fabricated. The measuring tube has a $3mm{\times}4mm$ rectangular cross-section, 9 mm length, and a $2mm{\times}3mm$ plate electrode and a ${\Phi}1.5mm$ point electrode. The design parameters, such as the magnetizing frequency and the number of coil turns, and the diameter were optimized. The EMF was tested with a gravimetric calibrator and showed good linearity in the range of 0 to $1.17{\times}10^{-5}m^3/s$. The fluid conductivity was varied between 3 and $11{\mu}S/cm$, and the magnitude of the flow signal was proportional to the fluid conductivity and the wetted area of the electrode. The design information and the test results provide flow measurement techniques for very low flowrate.