• Title/Summary/Keyword: 미세 박리

Search Result 102, Processing Time 0.02 seconds

Enhanced Electric Conductivity of Cement Composites by Functionalizing Graphene Oxide (산화그래핀 기능화에 의한 시멘트 복합체의 전기전도 특성 개선)

  • Jung-Geun Han;Jae-Hyeon Jeon;Young-Ho Kim;Jin Kim;Jong-Young Lee
    • Journal of the Korean Geosynthetics Society
    • /
    • v.22 no.1
    • /
    • pp.1-7
    • /
    • 2023
  • This study has utilized self-assembled monolayers technology to improve electrical property of graphene-oxide, which has been seperated graphine powder through a chemical exfoliation. Aluminum sulfate (Al2(SO4)3) was applied on graphene-oxide as a reactant, and the fundamental research was carried out to apply on the self-sensing of cement-based construction structures. Electric resistance measurement result has shown that cement-composites with GO and Al-GO can be used as a conductor, electric resistance of GO and Al-GO contained composites improved by 10.2% and 15.9% respectively when compared to the standard cement-composite. Microstructure analyzation shown the formation of Al(OH)3 gel when Al-GO was added, which is speculated to result the smooth flow of current by improving the density of cement-composite. This implies that graphene-oxide has a possibility to be utilized as smart building materials and construction structure itself rather than just a structure.

Chip-to-chip Bonding with Polymeric Insulators (고분자 절연체를 이용한 칩투칩 본딩)

  • Ye Jin Oh;Seongwoo Jeon;Jin Su Shin;Kee-Youn Yoo;Hyunsik Yoon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.31 no.3
    • /
    • pp.87-90
    • /
    • 2024
  • Currently, when oxides are used as insulators in hybrid bonding for 3D integration, they are prone to delamination due to their surface characteristics, and the RC delay value due to the resistance of the metal and the capacitance of the insulator increases as the wiring of the semiconductor chip becomes longer. To solve these problems, we studied the optimization of the conditions of the polymer insulator bonding method for hybrid bonding. To check the possibility of the de-wetting method, we coated a polymer film on the existing micro pillar and conducted hot-press bonding to remove the polymer between the metals. Through this study, it is expected that the introduction of polymers as insulators in hybrid bonding and fine-pitch metal bonding will improve signal transmission speed by reducing RC delay. It is also expected to be commercialized in the future to increase the number of I/O terminals by applying it to hybrid bonding.

Therapeutic Endoscopy-related Gastrointestinal Bleeding and Thromboembolic Events in Patients Using Warfarin or Direct Oral Anticoagulant (와파린 및 새로운 경구용 항응고제를 복용하는 환자에서의 치료 내시경과 관련된 위장관 출혈 및 혈전색전증의 위험)

  • Na, Hee Kyong
    • The Korean Journal of Gastroenterology
    • /
    • v.72 no.5
    • /
    • pp.271-273
    • /
    • 2018
  • 내시경 시술 전 일시적으로 항응고제를 중단하는 것은 위장관 출혈의 위험과 혈전색전증의 위험 사이에 적절한 균형을 잡기 어렵기 때문에 논란의 여지가 많다. 와파린은 새로운 경구용 항응고제(direct oral anticoagulant agent, DOAC)보다 임상의에게 더 친숙하고, 효과를 쉽고 빠르게 전환시킬 수 있다는 장점이 있지만 복잡한 약역동학 특징과 좁은 치료적 범위 때문에 관리가 어렵다. 반면, DOAC는 약물의 모니터링 및 용량 조절 없이 정해진 용량으로 처방이 가능하며, 빠르게 작용하고, 반감기가 짧아 관리가 쉽지만 해독제가 없다는 단점이 있다. 이전 연구들에서 DOAC를 복용한 환자들은 와파린을 복용한 환자들보다 시술과 관련되지 않은 위장관 출혈의 위험이 높았다고 보고한 바 있다. 하지만 시술과 관련된 위장관 출혈 위험에 대하여는 알려진 바가 없는 실정이다. 미국이나 유럽 내시경 가이드라인들에서는 저위험 내시경 시술을 받는 환자들에서는 와파린과 DOAC를 유지하도록 권고하고 있으며, 고위험 시술의 경우에는 와파린를 사용하는 환자들에서 헤파린 교량 요법(heparin bridging)을 시행하도록 권고하고 있다. 임상적으로 DOAC를 사용하는 환자들 또한 혈전색전증을 예방하기 위하여 헤파린 교량 요법을 시행해볼 수 있는데, 와파린 및 DOAC의 헤파린 교량 요법과 관련된 출혈 및 혈전색전증 위험의 차이 또한 명확하지 않다. 따라서 저자들은 1) 와파린과 DOAC 치료를 받는 환자들에서의 출혈, 혈전색전증 및 사망의 위험을 비교하고자 하였으며, 2) 13종류의 고위험 내시경 시술 중에서 시술별 위험을 비교하고, 3) 헤파린 교량 요법이 합병증의 발생을 증가시키지 않는지 확인하고자 본 연구를 진행하였다. 일본 대규모 국가 입원 환자 데이터베이스를 이용하여 2014년 4월부터 2015년 5월까지 시술 전 와파린 또는 DOAC(rivaroxaban, apixaban, dabigatran, edoxaban)를 복용하고, 13종류의 고위험 내시경 시술을 시행받은 20세 이상의 성인 환자 총 16,977명을 확인하였다. 고위험 시술은 용종 절제술, 내시경 점막절제술, 내시경 점막하박리술, 협착 부위의 풍선확장술, 내시경 지혈술, 내시경 정맥결찰술, 내시경 주사 경화요법, 내시경 괄약근절개술, 내시경 초음파 유도하 미세침 흡인 검사, 경피적 위루술을 포함하였다. 일대일 성향 점수 매칭 분석(propensity score matching, 나이, 성별, 체질량 지수, 기저 질환, 병원의 규모, 시술의 종류, 약물의 종류를 매칭)을 시행하여 와파린군과 DOAC군에서 시술 위장관 출혈 및 혈전색전증, 사망의 발생을 비교하였다. 또한 경구항혈전제와 헤파린 교량 치료 시행 유무에 따라, DOAC 단독군, 와파린 단독군, DOAC와 헤파린 교량 요법군, 와파린과 헤파린 교량요법군으로 나누어, 하위군(subgroup) 분석을 시행하였다. 5,046쌍이 성향 점수 매칭 분석에 포함되었으며, 와파린군에서 DOAC군보다 통계적으로 의미 있게 위장관 출혈의 비율이 높았다(12.0% vs. 9.9% p=0.02). 혈전색전증 발생률(5.4% vs. 4.7%)과 입원중 사망률(5.4% vs. 4.7%)은 양 군에서 의미 있는 차이는 없었다. DOAC 종류별로 나누어 하위군 분석을 시행하였을 때, 와파린군은 rivaroxaban군에 비하여 위장관 출혈의 비율이 높았으며, rivaroxaban군, dabigatran군에 비하여 혈전색전증의 비율이 높았고, 입원 중 사망률에서는 의미 있는 차이는 없었다. 내시경 시술의 종류로 보정하였을 때 위장관 출혈 및 혈전색전증, 사망률은 DOAC 단독으로 치료한 환자에서보다 와파린과 헤파린 교량 요법(bridging) 또는 DOAC과 헤파린 교량 요법을 시행한 환자에서 높았다. 시술 종류 중에서는 위루관 삽입술에 비하여 내시경 점막하박리술, 내시경 점막절제술 및 내시경 정맥류결찰술, 내시경 주사경화요법을 시행한 환자에서 위장관 출혈의 위험이 가장 높았으며, 하부 내시경 점막절제술, 하부 용종 절제술, 내시경적 유두괄약근절제술 또는 내시경 초음파 유도하 미세침 흡인 검사는 중등도 위험을 보였다.

Analysis of Air Voids System Using Image Analysis Technique in Hardened Concrete (화상분석법을 통한 경화 콘크리트의 미세 공극 구조 분석)

  • Yun Kyong-Ku;Jeong Won-Kyong;Jun In-Koo;Lee Bong-Hak
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.6 s.84
    • /
    • pp.741-750
    • /
    • 2004
  • Air voids in hardened concrete have an important influence on concrete durability such as freeze-thaw resistance, surface scaling resistance, and water permeability, and they have been characterized by spacing factor Linear traverse and point count methods in ASTM standard have been used in estimating an air void system in hardened concrete. However, these methods require lots of time and efforts, further they are not repeatable. Image analysis method could be utilized In estimating an air void systems in hardened concrete with a developments of microscope, digital camera and computer program. The purpose of this study was to develope image analysis method and provide a guideline by comparing the results from ASTM method and image analysis method. The concerns were at air void content and diameter distribution, air voids system as well as spacing factors. The experimental variables included air content by air entrained agent (0, 0.01, $0.03\%$) and depth of specimen (top, middle, bottom). The result showed that it was possible to calculate spacing factor using image analysis technique, as well as air content, air diameter distribution, and air structure. This study also contributed in developing an reasonable and repeatable image analysis method.

Effect of Firing Temperature on Microstructure and the Electrical Properties of a ZnO-based Multilayered Chip Type Varistor(MLV) (소성온도에 따른 ZnO계 적층형 칩 바리스터의 미세구조와 전기적 특성의 변화)

  • Kim, Chul-Hong;Kim, Jin-Ho
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.3
    • /
    • pp.286-293
    • /
    • 2002
  • Microstructure and the electrical porperties of a ZnO-based multilayered chip-type varistor(abbreviated as MLV) with Ag/Pd(7:3) inner electrode have been studied as a function of firing of temperature. At 1100$^{\circ}$C, inner electrode layers began to show nonuniform thickness and small voids, which resulted in significant disappearance of the electrode pattern and delamination at 1100$^{\circ}$C. MLVs fired at 950$^{\circ}$C showed large degradation in leakage current, probably due to incomplete redistribution of liquid and transition metal elements in pyrochlore phase decomposition. Those fired at 1100$^{\circ}$C and above, on the other hand, revealed poor varistor characteristics and their reproductibility, which are though to stem from the deformation of inner electrode pattern, the reaction between electrode materials and ZnO-based ceramics, and the volatilization of $Bi_2O_3$. Throughout the firing temperature range of 950∼1100$^{\circ}$C, capacitance and leakage current increased while breakdown voltage and peak current decreased with the increase of firing temperature, but nonlinear coefficient and clamping ratio kept almost constant at ∼30 and 1.4, respectively. In particular, those fired between 1000$^{\circ}$C and 1050$^{\circ}$C showed stable varistor characteristics with high reproducibility. It seems that Ag/Pd(7:3) alloy is one of the electrode materials applicable to most ZnO-based MLVs incorporating with $Bi_2O_3$ when cofired up to 1050$^{\circ}$C.

Ultrastructure of Cell Wall in the Suppressor Mutant of Null Pigmentation (SU-NPG) of Aspergillus nidulans (Aspergillus nidulans 색소결핍 억제돌연변이주의 세포벽 미세구조)

  • 정윤신
    • Journal of Life Science
    • /
    • v.14 no.1
    • /
    • pp.45-50
    • /
    • 2004
  • To investigate the effect of the cell wall on the pigmentation and branching in Aspergillus nidulans, ultrastructure of cell wall in suppressor mutant of the null pigmentation (SU-NPG, SU602) has been examined. Scanning electron microgrphs (SEM) revealed that the most outer layer of conidia wall peeled off in SU-NPG on day 6 from the complete conidiation. They also showed that hyphal growth and branching were not well developed in SU-NPG. Transmission electron micrographs (TEM) showed that the plasma membrane was not crenulated and the hyphal wall was thick in SU-NPG. These results indicated that the ultrastructure of cell wall in SU-NPC might be modified. Cytochemical analysis showed that the cell wall in SU-NPG was differentiated into Cl, C3, C2 and C4 layer in conidia and H1, H3, H2 and H4 layer in hyphae. C3 layer and H3 layer existed in SU-NPG. The increment of the diameter in SU-NPG hyphae might be caused by the thickness of H3 layer. These results suggest that SU-NPG may have an immature but the differentiated structure for the pigmentation in cell wall.

Crack Control of Flexure-Dominant Reinforced Concrete Beams Repaired with Strain-Hardening Cement Composite (SHCC) Materials (변형경화형 시멘트 복합체를 활용한 휨항복형 철근콘크리트 보의 균열제어)

  • Cha, Jun-Ho;Park, Wan-Shin;Lee, Young-Oh;Kim, Sun-Woo;Yun, Hyun-Do
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.1
    • /
    • pp.109-120
    • /
    • 2011
  • This paper presents an experimental study results on the crack control of flexure-dominant reinforced concrete beams repaired with strain-hardening cement composite (SHCC). Five RC beams were fabricated and tested until failure. One unrepaired RC beam was a control specimen (CBN) and remaining four speciemens were repaired with SHCC materials. The test parameters included two types of SHCC matrix ductility and two types of repair method (patching and layering). Test results demonstrated that RC beams repaired with SHCC showed no concrete crushing or spalling until final failure, but numerous hair cracks were observed. The control specimen CBN failed due to crushing. It is important to note that SHCC matrix can improve crack-damage mitigation and flexural behavior of RC beams such as flexural strength, post peak ductility, and energy dissipation capacity. In the perspective of crack width, crack widths in RC beams repaired with SHCC had far smaller crack width than the control specimen CBN under the same deflection. Especially, the specimens repaired with SHCC of PVA0.75%+PE0.75% showed a high durability and ductility. The crack width indicates the residual capacity of the beam since SHCC matrix can delay residual capacity degradation of the RC beams.

Dorsal Mini-thoracotomy for PDA Closure in Premature Neonates (후방 소개흉술을 통한 미숙아 동맥관 개존증의 수술요법)

  • Lee, Hyang-Lim;Choi, Chang-Hyu;Son, Dong-Woo;Shim, So-Yeon;Park, Kook-Yang;Park, Chul-Hyun
    • Journal of Chest Surgery
    • /
    • v.42 no.4
    • /
    • pp.434-440
    • /
    • 2009
  • Background: Surgical closure of a patent ductus arteriosus (PDA) can be considered when conservative medical treatment is ineffective or contraindicated. Low weight and earlier gestational age neonates who are treated with conservative medical therapy generally showed a higher failure rate. The morbidity of surgical PDA closure in such extremely low birth weight (ELBW) neonates is also high. Here we present the early results of a new technique for approaching the PDA through a dorsal minithoracotomy. Material and Method: From March 2006 to November 2008, 24 premature neonates underwent surgical PDA closure. The procedures were performed in the newborn intensive care unit via a 2 cm long dorsal minithoracotomy with the baby in the prone position with the left hemithorax elevated 30$^{\circ}$. Bimanual cotton swab blunt dissection completed the extrapleural accesstothe PDA and then two clips were applied. Tube thoracostomy was avoided if there was no meaningful pleural laceration. Result: The infants mean gestational age was 26.5$\pm$2.1 weeks (range: 23 to 30 weeks) and the average age at operation was 11$\pm$11 days. The mean body weight at operation was 933$\pm$271 grams (range: 570 to 1,700 grams). Eight patients expired, but there was no procedure-related death. Postoperative echocardiography revealed two cases of residual shunt but none of these shunts were detected on the follow up echocardiogram that was performed on the post operative 5 and 59 days. Conclusion: We concluded that the technique described here is an effective procedure in view of the satisfactory operative exposure and the low rate of complications.

Effect of Ta/Cu Film Stack Structures on the Interfacial Adhesion Energy for Advanced Interconnects (미세 배선 적용을 위한 Ta/Cu 적층 구조에 따른 계면접착에너지 평가 및 분석)

  • Son, Kirak;Kim, Sungtae;Kim, Cheol;Kim, Gahui;Joo, Young-Chang;Park, Young-Bae
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.28 no.1
    • /
    • pp.39-46
    • /
    • 2021
  • The quantitative measurement of interfacial adhesion energy (Gc) of multilayer thin films for Cu interconnects was investigated using a double cantilever beam (DCB) and 4-point bending (4-PB) test. In the case of a sample with Ta diffusion barrier applied, all Gc values measured by the DCB and 4-PB tests were higher than 5 J/㎡, which is the minimum criterion for Cu/low-k integration without delamination. However, in the case of the Ta/Cu sample, measured Gc value of the DCB test was lower than 5 J/㎡. All Gc values measured by the 4-PB test were higher than those of the DCB test. Measured Gc values increase with increasing phase angle, that is, 4-PB test higher than DCB test due to increasing plastic energy dissipation and roughness-related shielding effects, which matches well interfacial fracture mechanics theory. As a result of the 4-PB test, Ta/Cu and Cu/Ta interfaces measured Gc values were higher than 5 J/㎡, suggesting that Ta is considered to be applicable as a diffusion barrier and a capping layer for Cu interconnects. The 4-PB test method is recommended for quantitative adhesion energy measurement of the Cu interconnect interface because the thermal stress due to the difference in coefficient of thermal expansion and the delamination due to chemical mechanical polishing have a large effect of the mixing mode including shear stress.

Application of Acoustic Emission for Assessing Deterioration in Reinforced Concrete Beams (철근 콘크리트 빔의 노화도 평가를 위한 음향방출 기술의 응용)

  • Yoon, Dong-Jin;Park, Phi-Lip;Lee, Seung-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.4
    • /
    • pp.276-284
    • /
    • 2000
  • The acoustic emission (AE) behavior of reinforced concrete beams tested under flexural loading was investigated to characterize and identify the source of damage. This research was aimed at identifying the characteristic AE response associated with micro-crack development, localized crack propagation, corrosion, and debonding of the reinforcing steel. Concrete beams were prepared to isolate the damage mechanisms by using plain, notched-plain, reinforced, and corroded-reinforced specimens. The beams were tested using four-point cyclic step-loading. The AE response was analyzed to obtain key parameters such as the time history of AE events, the total number and rate of AE events, and the characteristic features of the waveform. Initial analysis of the AE signal has shown that a clear difference in the AE response is observed depending on the source of the damage. The Felicity ratio exhibited a correlation with the overall damage level, while the number of AE events during unloading can be an effective criterion to estimate the level of corrosion distress in reinforced concrete structures. Consequently, AE measurement characterization appears to provide a promising approach for estimating the level of deterioration in reinforced concrete structure.

  • PDF