Material Characteristics, Damage Evaluation and Weathering Mechanism on the Yi Chungmugong Tombstone of Chunglyolsa in Namhae, Korea (남해 충렬사 이충무공묘비의 재질특성, 손상도 평가 및 풍화과정 해석)

  • Cho, Ji Hyun;Lee, Chan Hee;Jo, Young Hoon;Kim, Sun Duk
    • Korean Journal of Heritage: History & Science
    • /
    • v.45 no.2
    • /
    • pp.100-113
    • /
    • 2012
  • The tombstone of Yi Chungmugong in the Joseon Dynasty located Namhae, Gyeongnam is consisted of sandstone. The Bisin and Bijwa of the tombstone have narrow range of magnetic value less than $0.2({\times}10^{-3}SI\;unit)$ and the Isu covered pigment on surface also has same magnetic susceptibility range. Therefore, the composition of all tombstone have similar lithological characteristics. The side of the tombstone appeared fine-grained sandstone to coarse-grained graywacke boundary clearly and back of tombstone observed lamination. Especially deterioration type is concentrated in front and back of the tombstone blistering (8.2% of back), scaling (10.2% of back), granular disintegration (28.1% of back) and discoloration (53.5% of front). Results of contaminants analysis, the front of the Bisin separated in 3 type of surface - granular disintegration-scaling. Among this area, surface detected Ca, S and Cl in high density, but these contaminants elements have more lower detect density from surface to granular disintegration. By contrast, on scaling area, these components are almost not detected, but Fe, K consisted of rock forming elements are detected. It is necessary to conservation and treatment of Yi Chungmugong tombstone in continuously, and salt cleaning on surface also needed. So through activity of conservation and restoration, epigraph preserved for their worth.

A Study on the Performance Evaluation of Repair Material and Method for Reinforced Concrete Structure by tong Term Exposure Experiment (장기폭로실험에 의한 철근콘크리트 구조물 보수재료 · 공법의 성능평가에 관한 연구)

  • Kim Moo-Han;Kim Yong-Ro;Kim Jae-Hwan;Ho Jang-Jong;Cho Bong-Suk
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.5 s.83
    • /
    • pp.659-666
    • /
    • 2004
  • In this study, for the establishment of the performance evaluation methods and the quality control standard of durability recovery method, the quantitative exposure data by long term exposure test under the coast and air environment is accumulated and analyzed. Investigating and evaluating the result of exposure test during 18 months of exposure age under the coastal and normal atmosphere environment, micro crack, swelling and spatting of surface coating material crack of repair standards of repair material and method through continuous exposure test in the future.

Accelerated Ultrasonic Fatigue Testing Applications and Research Trends (초음파 가속피로시험 적용 사례 및 연구 동향)

  • Cho, In-Sik;Shin, Choong-Shig;Kim, Jong-Yup;Jeon, Yong-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.6
    • /
    • pp.707-712
    • /
    • 2012
  • Very high cycle fatigue (VHCF) behavior of aerospace components has emerged much attention due to their long service life. In this study, a piezoelectric ultrasonic fatigue testing (UFT) system has been developed by Mbrosiatec Co., Ltd. to study the high cycle fatigue (HCF) strength of Ti-6Al-4V alloy. Hourglass-shaped specimens have been investigated in the range from $10^6$ to $10^9$ cycles at room temperature under completely reversed R = -1 loading conditions,. Scanning electron microscopy (SEM) analysis revealed that failures occurred in the entire range up to the gigacycle regime, and the fractures have beenfound to be initiated from the surface, unlike in steels. However, it was found from the SEM microgprahs that microcracks transformed into intergranular fractures. Thus, it can be concluded from according to the results that this test method can be applicable to commercialized automotive and railroad parts that require high cycle fatigue strength.

Ultrasound Thermography Technique for Detecting Micro Defects in Vehicle Engine Block (자동차 엔진블럭의 미세크랙 검출을 위한 초음파 서모그래피 기법에 관한 연구)

  • Kim, Sung Hyun;Kim, Jae Yeol;Choi, Seung Hyun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.4
    • /
    • pp.443-446
    • /
    • 2013
  • An infrared thermography technique can be used to inspect a large area simultaneously and to detect defects such as cracks or delaminations in real time. Infrared thermography is a technique in which visual images are formed from the infrared range from subjects according to their thermal radiation. The molecules of all objects are disturbed by heat, and the molecular motion becomes more active when the temperature rises and less active when the temperature falls. In this study, the applicability and feasibility of ultrasound thermography for detecting defects in an engine block, which is a key component in the automobile industry, were verified. A nondestructive reliability test was conducted to study the defects, after which the results were analyzed.

Deterioration Mechanism Interpretation and Surface Contaminant Analysis of the Five-Storied Stone Pagoda in Tapriri, Uiseong (의성 탑리리 오층석탑의 표면오염물 분석 및 손상메커니즘 해석)

  • Lee, Mi Hye;Chun, Yu Gun;Lee, Myeong Seong
    • Economic and Environmental Geology
    • /
    • v.46 no.5
    • /
    • pp.445-453
    • /
    • 2013
  • The Uiseong Tapriri Five-Storied Stone Pagoda (National Treasure No. 77) is typical stone cultural heritage in Unified Silla Dynasty, Korea. The pagoda has been occurred black, brown discoloration and microcrack, exfoliation, granularity decomposition with white discoloration because of continuous weathering. As the results of analysis for the contaminants, chemical weatherings are generated that black contaminant by manganese oxide, brown contaminant by iron oxide, white contaminants by gypsum and taranakite. And physical weatherings, such as microcrack, exfoliation, are occurred by salt(gypsum) crystallization. Therefore, these need to remove the contaminants according to the conservation treatment manual, and regular monitoring using P-XRF to preserve long-term the Five-Storied Stone Pagoda at Tapri-ri, Uiseong.

Dorsalis Pedis Tendocutaneous Delayed Arterialized Venous Flap in Hand Reconstruction (지연처치후 동맥화된 족배 정맥 건피판을 이용한 수부의 재건)

  • Cho, Byung-Chae;Lee, Dong-Hoon
    • Archives of Reconstructive Microsurgery
    • /
    • v.8 no.1
    • /
    • pp.56-63
    • /
    • 1999
  • We report two patients whose acute soft tissue and tendon defects in the hand were treated by the dorsalis pedis tendocutaneous delayed arterialized venous flap between 1994 and 1997. The surviving surface area was 100% in both patients. The flap size was $10{\times}10cm\;and\;6{\times}6cm$. At two weeks postoperatively, active flextion and passive extension commenced, and progressive resistance exercises were performed for an additional 5 weeks. Flaps showed a similar color match and skin texture compared with the normal skin of the hand. Advantages of the tendocutaneous delayed arterialized venous flap are developing a larger flap than can be obtained with pure venous flap or arterialized venous flap, increasing survival rate of the arterialized venous flap which permits using a composite flap, preservation of main artery of the donor site, taking thin non-bulky tissue and easy elevation without deep dissection. The disadvantages are the requirement of a two stage operation, donor site scarring and weak extension of the toe.

  • PDF

Thermal Warpage Behavior of Single-Side Polished Silicon Wafers (단면 연마된 실리콘 웨이퍼의 열에 의한 휨 거동)

  • Kim, Junmo;Gu, Chang-Yeon;Kim, Taek-Soo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.27 no.3
    • /
    • pp.89-93
    • /
    • 2020
  • Complex warpage behavior of the electronic packages causes internal stress so many kinds of mechanical failure occur such as delamination or crack. Efforts to predict the warpage behavior accurately in order to prevent the decrease in yield have been approached from various aspects. For warpage prediction, silicon is generally treated as a homogeneous material, therefore it is described as showing no warpage behavior due to thermal loading. However, it was reported that warpage is actually caused by residual stress accumulated during grinding and polishing in order to make silicon wafer thinner, which make silicon wafer inhomogeneous through thickness direction. In this paper, warpage behavior of the single-side polished wafer at solder reflow temperature, the highest temperature in packaging processes, was measured using 3D digital image correlation (DIC) method. Mechanism was verified by measuring coefficient of thermal expansion (CTE) of both mirror-polished surface and rough surface.

Fabrication of $Sr_2FeMoO_6$ thin films by RF Sputtering (RF 스퍼터법에 의한 $Sr_2FeMoO_6$ 박막 제조)

  • Ryu, Hee-Uk;Sun, Ho-Jun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.24-24
    • /
    • 2010
  • 대형구조물의 구조안정성 진단, 로봇과 같은 지능기계의 제어, 환경오염을 감지하기 위한 센서의 중요성은 날로 증대되고 있다. 이러한 센서의 감도와 성능을 높이기 위해서 소형화, 다기능화, 집적화가 요구되고 있는데, 고성능 센서소자들의 집적화를 위해서 기존에 적용된 벌크형태의 재료들을 박막화하여 다층적층 및 소형화할 필요가 있다. 집적화 센서의 구현에 있어서 전극박막은 센서의 특성을 좌우하는 중요한 역할을 한다. 일반적으로 금속박막이 전극으로 사용되고 있으나 열적 불안정성 및 박리현상의 문제점을 지니고 있다. 따라서 이를 해결하기 위해 전도성산화막을 전극으로 적용하고자하는 연구가 요구되고 있다. 전도성산화막을 전극으로 적용하면 센서소자의 성능이 개선되는 경향이 있다. $Sr_2FeMoO_6$(SFMO) 산화물은 자기장을 인가했을 때 저항이 감소하는 CMR(colossal magnetoresistance) 물질이며 상온비저항이 낮은 것으로 알려져 있다. 이중 페롭스카이트 (double perovskite) 구조를 갖는 $Sr_2FeMoO_6$ 박막은 센서소자의 전극으로 적용 가능할 것으로 생각되어 박막을 제조하고자 하였으며 미세구조와 전기전도 특성을 조사하였다. 박막제조를 위해서는 RF 스퍼터법을 사용하였다. 스퍼터를 위한 타겟은 고상반응법으로 분말타겟을 제조하였다. Ar/$O_2$ 가스 유랑변화, 압력변화, 기판 온도변화가 박막의 상형성 등 박막특성에 미치는 영향을 조사하였다. 기판으로는 $SiO_2$(100nm)/Si 기판을 사용하였다. 증착직후에는 비정질막이 얻어졌으며 SFMO 상을 만들기 위해서는 후열처리가 필요하였는데, 환원성 가스 분위기 [$H_2$(5%)/Ar] 에서 열처리 조건을 최적화하여 이중 페롭스카이트 구조의 단일상 박막을 제조할 수 있었다. SFMO 단일상 박막은 증착시에나 후열처리 시 산소의 억제가 중요함을 알 수 있었다.

  • PDF

Detection of Acoustic Signal Emitted during Degradation of Lithium Ion Battery (리튬이온전지의 열화손상에 의한 음향방출 신호 검출)

  • Choi, Chan-Yang;Byeon, Jai-Won
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.2
    • /
    • pp.198-204
    • /
    • 2013
  • Acoustic emission(AE) signal was detected during charge and discharge of lithium ion battery to investigate relationships among cumulative count, discharge capacity, and microdamages. AE signal was received during accelerated charge/discharge cycle test of a coin-type commercial battery. A number of AE signals were successfully detected during charge and discharge, respectively. With increasing number of cycle, discharge capacity was decreased and AE cumulative count was observed to increase. Microstructural observation of the decomposed battery after cycle test revealed mechanical damages such as interface delamination and microcracking of the electrodes. These damages were attributed to sources of the detected AE signals. Based on a linear correlation between discharge capacity and cumulative count, feasibility of AE technique for evaluation of battery degradation was suggested.

Analysis for Chloride Penetration in Concrete under Deicing Agent using Multi Layer Diffusion (다층구조확산을 고려한 제설제에 노출된 콘크리트의 염화물 해석)

  • Seo, Ji-Seok;Kwon, Seung-Jun
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.4
    • /
    • pp.114-122
    • /
    • 2016
  • Concrete is cost-benefit and high-durable construction material, however durability problem can be caused due to steel corrosion under chloride attack. Recently deicing salt has been widely spread in snowing season, which accelerates micro-cracks and scaling in surface concrete and the melted deicing salt causes corrosion in embedded steel. The previous governing equation of Fick's 2nd Law cannot evaluate the deteriorated surface concrete so that another technique is needed for the surface effect. This paper presents chloride penetration analysis technique for concrete subjected to deicing salt utilizing multi-layer diffusion model and time-dependent diffusion behavior. For the work, field investigation results of concrete pavement exposed deicing salt for 18 years are adopted. Through reverse analysis, deteriorated depth and increased diffusion coefficient in the depth are evaluated, which shows 12.5~15.0mm of deteriorated depth and increased diffusion coefficient by 2.0 times. The proposed technique can be effectively applied to concrete with two different diffusion coefficients considering enhanced or deteriorated surface conditions.