• Title/Summary/Keyword: 미세전류

Search Result 441, Processing Time 0.035 seconds

Butt Weldability for SS400 Using Laser-Arc Hybrid Welding (레이저-아크 하이브리드 용접을 이용한 SS400의 맞대기 용접 특성)

  • Kim, Jong Do;Myoung, Gi Hoon;Park, In Duck
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.7
    • /
    • pp.667-672
    • /
    • 2016
  • This study presents results of an experimental investigation of the laser-arc, hybrid, butt welding process of SS400 structural steel. Welding parameters including laser power, welding current and speed were varied in order to obtain one-pass, full-penetration welds without defects. The conditions that resulted in optimal beads were identified. After welding, hardness measurements and microstructure observations were carried out in order to study weld properties. The mechanical properties of both the base material and welded specimen were compared based on the results of tensile strength measurements. The yield and tensile strengths were found to be similar.

전해환원 금속전환체 잔류염 제거 기초 실험

  • Park, Byeong-Heung;Jeong, Myeong-Su;Jo, Su-Haeng;Heo, Jin-Mok
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2009.06a
    • /
    • pp.296-296
    • /
    • 2009
  • 산화물 사용후핵연료를 대상으로 하는 파이로 공정은 고온 용융염 매질에서 산화물을 금속으로 전환시키는 전해환원 공정으로부터 시작된다. 이후, 전해정련 공정이 도입되어 전해환원 공정에서 금속으로 환원된 생성물을 처리하게 된다. 전기화학적 공정인 이 두 공정에는 전류전달 매질인 전해질로 용융염이 사용된다. 그러나 전해환원 공정은 LiCl 염을 기반으로 하는 반면 전해정련은 LiCl-KCl 공융염 조건에서 운전하여 두 공정의 연계성 향상 및 공정 안정성 확보를 위해서는 전해환원 공정에서 생성되는 금속전환체에 존재하는 잔류염을 제거하는 공정의 도입이 두 공정사이에 고려되고 있다. 전해환원 공정에서 산화물이 금속으로 환원되는 동안 고체입자의 외형이 유지되며 따라서 제거된 산소에 의해 금속전환체에는 공극이 발생하게 된다. 또한, 전해환원에 도입되는 산화물의 물리적 형태가 분말 또는 펠렛 등 다양한 형태로 도입 가능하여 단위 입자들 사이에 많은 공극이 발생하게 된다. 이렇게 기존재하거나 또는 공정 운전에 의해 새롭게 생성된 공극에는 전해환원 매질인 LiCl 염이 침투하여 금속전환체는 염에 의해 젖게 되며 공정 종료시 고화되어 금속전환체에 포함된다. LiCl을 제거하기 위해서는 가열에 의한 증류가 연구되고 있다. 그러나 LiCl의 낮은 증기압에 의해 비교적 낮은 온도에서 증발시키기 위해서는 감압조건이 필수적으로 고려되어야 한다. 한국원자력연구원에서는 다공성 모의 금속전환체를 사용하여 LiCl에 의한 Wetting 후 적절한 증발 조건 결정을 목적으로 온도 및 압력 조건 설정을 위한 기초실험에 결과를 수행하였다. 본 연구의 기초 실험 결과 $700^{\circ}C$온도 조건과 감압조건이 잔류염 제거를 위한 공정조건임을 밝혔다. 또한 모의 금속전환체를 담고 있는 미세 다공성 Basket은 고온조건에서 공극의 변형에 의해 증발에 대한 저항으로 작용하여 증발 효율을 저하시키는 것으로 나타났다. 따라서 잔류염 제거를 위해서는 전해환원 Basket이 비교적 큰 공극을 지녀야 할 것으로 판단된다.

  • PDF

The Effect of Microcurrent Electrical Stimulation on the Articular Cartilage Recovery in Osteoarthritis (비침습식 미세전류자극이 실험적으로 유발된 흰쥐의 골관절염 회복에 미치는 영향)

  • Bang, Hyun-Soo;Kang, Jong-Ho;Cheon, Song-Hee;Kim, Min-Hee;Park, Soo-Jin;Kim, Jin-Sang;Park, Rae-Joon
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.2 no.2
    • /
    • pp.151-159
    • /
    • 2007
  • Purpose : The purpose of the study was to investigate the effect of cold application on knee joint in rats induced by osteoarthritis. Methods : Osteoarthritis was induced in female Sprague-Dowley rats by injecting into articular cavity of knee joint with 4% Kaolin, 2% carrageenan. Rats were divided randomly into the control and MES applicated group. The Experimental group was applicated MES in rat knee joint for 30 minutes. Results : Recovery of articular cartilage surface and thickness of articular cartilage increased after MES application. And chondrocytes were distributed widely throughout the cartilage matrix. The physical effects of Microcurrent Electrical Stimulation. Decrease in blood flow. Delay of neurotransmitter velocity Decrease in metabolism activity and inhibit the progress of the infection. Decrease in pain and muscle rigidity, inhibition of circulation Conclusion : This study shows that MES application affects articular cartilage recovery in osteoarthritis.

  • PDF

The Effect of Microcurrent Stimulation on Immediately Early Gene in Pain Induced Model (실험적 통증유발 모델에서 조기발현 유전자에 대한 미세전류자극의 효과)

  • Kim Gye-Yeop;Kim Tae-Youl;Oh Myung-Hwa;Kim Sun-Eun;Cheong Mee-Sun;Suh Young-Sook
    • The Journal of Korean Physical Therapy
    • /
    • v.16 no.3
    • /
    • pp.9-21
    • /
    • 2004
  • The purpose of study is that we will observe the change of c-fos with the immunohistochemistry method and then we will study the effect of micro current stimulation following the frequency after inducing pain to rats with capsaicin. Rat were classified to SD and they have growed for 8 weeks. We classify to four groups, ordinal group is used in experiment I, the group which we induce pain is used in experiment II, the application group which we induce pain and then the high frequency micro current stimulation is used in experiment III, the application group which we induce pain and then the low frequency micro current stimulation is used in experiment IV, we get the following result. Compare with experiment II, experiment III, and experiment IV from acute pain modal in the immunohistochemistry experiment which has c-fos protein as an antigen, c-fos immunoreactive positive neurons significantly after induced pain for two hours(p<0.001). According to these results, from rats induced pain, micro current stimulation effect to reducing pain, but following frequency micro current stimulation theraphy isn't different from immunoreactive c-fos

  • PDF

Anti-hyperalgesic Effects of Electroacupuncture Combination of Microcurrent Stimulation in Rat with Induced Inflammation (염증유발 백서에서 전침자극과 미세전류자극의 항-통각과민 효과)

  • Kim, Young-Phil;Lee, Jeong-Woo;Seo, Sam-Ki;Yoon, Se-Won;Yoon, Hui-Jong;Kim, Tae-Youl
    • The Journal of Korean Physical Therapy
    • /
    • v.19 no.1
    • /
    • pp.67-78
    • /
    • 2007
  • Purpose: The purpose of this study were to examine the anti-hyperalgesic effects of combination of electroacupuncture and microcurrent on anti-hyperalgesia in local hyperalgesia zone. Methods: It used 24 rats for experiment, divided them into control group, electroacupuncture group (EA group), microcurrent group (MC group), combination of electroacupuncture with microcurrent (EA+MC group), caused hyperalgesia by injecting ${\lambda}-carrageenan$ into hindpaw. Thickness of hindpaw, mechanical pain threshold (MPT), thermal pain threshold (TPT), noxious flexion withdrawal reflex (NFR) and somatosensory evoked potential (SEP) were measured immediately after induction, at 24 hours, 48 hours and 72 hours after induction. The electrical stimulation was given once a day for three days, 20min per session. Results: Change of thickness, MPT, and TPT showed significant difference in all groups compared to control group. In particular, there were remarkable difference in EA+ME group. In particular there were remarkable differences in EA group and EA+MC group. Change of NFR(% threshold, % reaction time, % RMS) and SEP showed mainly significant differences in EA group and EA+ME group compared to control group. In particular, there were remarkable difference in EA+ME group. Conclusion: The above results suggest that appropriate combination of microcurrent with electroacupuncture for pain control will be very desirable.

  • PDF

Influence of Microcurrent Therapy in Interleukin-1 Expression in Rhueumatoid Arthritis Rats (미세전류치료가 류마티스 관절염 유발 흰쥐의 Interleukin-1 발현에 미치는 영향)

  • Lee, Hyun-Min;Chae, Yun-Won
    • The Journal of Korean Physical Therapy
    • /
    • v.21 no.2
    • /
    • pp.103-108
    • /
    • 2009
  • Purpose: Electrical stimulation is one of several treatments recommended for RA patients. Electrical stimulation of RA patients, reduces pain, or facilitates joint motion prior to exercises. However, there is still limited evidence on the efficacy of electrical stimulation and thus any conclusions drawn about this method remain controversial. Recently, Microcurrent Electrical Neuromuscular Stimulation (MENS) has received significant attention as a potential method of electrical stimulation. In this study, we investigated the effect of microcurrent treatment in rheumatoid arthritis rat. Methods: Subjects were allocated either to the control group or experimental group, which was subject to microcurrent stimulation. Interleukin-1 expression in the metatarsophlangeal joint and the oedema index in the ankle were used for classification and subsequent evaluation of pathology. Subjects were assessed at 1, 7 and 14 days after inducing rheumatoid arthritis through adjuvant injection. Thirty-six subjects, 18 in each group, were used in this study. Statistical analysis was performed by calculating the differences between the two groups and between each interval assessment. Categorical variables were compared between the two groups with the paired-T test. The one-way ANOVA test was performed to assess changes in ordinal variables. Results: Baseline characteristics were similar in both groups. Statistically significant differences were found between the two groups. The biological marker of pro-inflammatory cytokine and oedema index were decreased in response to this treatment. Conclusion: These data show that treatment of rheumatoid arthritis with a microcurrent stimulation device reduced the oedema index and pro-inflammatory cytokine IL-1.

  • PDF

The Effect of Microcurrent Stimulation on Histological Structure of Wound in Rat (미세전류전기자극이 흰쥐 창상의 조직학적 구조에 미치는 영향)

  • Oh, Hye-Jin;Kim, Jung-Woo;Kim, Moon-Su;Park, Jang-Sung
    • The Journal of Korean Physical Therapy
    • /
    • v.20 no.1
    • /
    • pp.67-73
    • /
    • 2008
  • Purpose: The purpose of this study was to investigate the effect of the intensity of microcurrent stimulation (with currents of 50 ${\mu}A$, 100 ${\mu}A$ and 300 ${\mu}A$ using a pulse frequency of 5 pps) on wound healing in rats. Methods: Sixty male Korean rats were randomly divided into four groups of 15 rats that were subjected to four different treatment protocols (control group, no treatment; experimental groups, treated with currents of 50 ${\mu}A$, 100 ${\mu}A$ or 300 ${\mu}A$). An experimental 20 mm linear wound was made in each animal and all animals in the experimental groups received microcurrent stimulation once a day for 20 minutes until the day of sacrifice on day 1, day 3 and day 6. An optical microscope was used to determine any histological changes. Results: The experimental results were as follows. 1. In an examination with the naked eye, all groups showed similar changes until the first day. However, from the third day, a little intercellular fluid soaked through wound region in the control group rats. In the experimental group animals, little intercellular fluid soaked through wound region, and swelling and redness did not appear, from the third day. 2. In an examination with histological evaluation, more significant changes were observed in all of the experimental group rats than the control group animals. Especially, a stimulation intensity of 50 ${\mu}A$ caused a more significant effect than the use of the other intensities by day 6 of wound healing. In addition, rapid recovery was observed. Conclusion: It was determined that microcurrent stimulation had a positive effect on wound healing. A stimulation intensity of 50 ${\mu}A$ was more effective than the other intensities (100 ${\mu}A$ and 300 ${\mu}A$) utilized for wound healing. Furthermore, low-intensity microcurrent stimulation was more effective for the purpose of wound healing.

  • PDF

Effects of Spraying Conditions on the Porosity and Hardness of Plasma Sprayed MgO Stabilized Zirconic Thermal Barrier Coatings (Plasma 용사된 MgO 안정화 지르코니아 단열피복의 기공도와 경도에 미치는 용사조건의 영향)

  • Park, Yeong-Gyu;Choe, Guk-Seon;Lee, Dong-Hui
    • Korean Journal of Materials Research
    • /
    • v.2 no.2
    • /
    • pp.85-94
    • /
    • 1992
  • The size, morphology and distribution of pores which affect on the physical properties of thermal barrier coatings were investigated to find the relationship with spraying parameters. The plasma-sprayed zirconia coatings contained numerous micropores as well as macropores which were appeared as spherical and irregular pores, and cracks. The pore formation process and its characteristics were varied with spraying distance. Porosity itself was varied with spraying parameters such as spray gun current, gas flow rate and the gas used(Ar or $N_2). The Porosity of coatings was ranged from 10 to 18% with the variation of spraying conditions. The relative hardness measured by the scratch test, showed strong dependence on the porosity of coatings rather than spraying parameters.

  • PDF

Failure analysis of a turbo molecular pump in semiconductor equipments (반도체 장비에서 터보 분자 펌프의 파손 사례 연구)

  • Jeong, Jin-Yong;Ju, Jeong-Hun;O, Sam-Gyun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.120-120
    • /
    • 2018
  • 반도체 소자나 디스플레이 패널 제조 공정에 가장 많이 사용되는 진공 펌프인 터보 분자 펌프는 오일을 사용하지 않고, 설치 방향이 자유로우며 넓은 작동 압력 영역을 가지고 있어서 고가임에도 불구하고 점점 더 사용 영역을 넓혀 가고 있다. 상하의 두 곳에 회전축을 지지하는 베어링이 필요한데, 기계식 금속 베어링을 채용하는 경우에는 반드시 윤활유를 공급해 주어야 하고, 고온, 부식성 또는 산화성 가스의 배기 시에는 퍼지 가스로 비활성인 질소나 알곤등을 이용하여 보호를 해주어야 한다. 반면, 자기 베어링을 채택한 모델은 윤활의 걱정에서 자유로울 수 있기 때문에 채용이 늘어나고 있다. 동일극의 반발력이나 반대극의 인상력을 이용한 구조를 갖게 되는데 갑작스러운 입구 쪽 압력의 증가 시에는 자석 끼리 부딪치는 일이 발생하고 이로 인해서 로터 모듈 전체에 큰 손상을 갖게 되므로 한 곳 정도에 비상용 터치 다운 베어링을 기계식으로 윤활제 없이 설치하기도 한다. 기본적으로 자기 베어링 방식은 로터 모듈의 부상과 제어를 위해서 3축 또는 5축 제어를 하게 되는데 여기에는 전자석의 전류를 미세하게 조정하여 피드백 하는 시스템을 활용하기 때문에 외부에서의 자기장이 일정값 이상 침투하게 되면 제어 회로의 기능에 문제를 일으키게 된다. 또한 축 방향에 수직인 자기장의 강도가 높아지면 고속으로 회전하는 금속 블레이드가 자속을 자르게 되므로 표면에 와전류가 발생하여 문제가 된다. 터보 분자 펌프는 회전자와 고정자 간격이 1 mm 이내로 작아서 약간의 진동이라도 발생하면 회전자와 고정자 간에 충돌이 일어나고 이는 곧 파손으로 이어진다. 그림 1에는 파손 원인 분석을 위한 회전자 모듈의 수치 해석용 모델의 일부를 나타내었고, 그림 2에는 실제로 외부 자기장에 의한 파손이 발생한 사례의 자기 베어링 모듈의 사진을 나타내었다. 본 발표에서는 외부 자기장의 형태에 따라 제어 자기장에 미치는 영향을 CFD-ACE+(ESI corp)를 활용하여 해석하였다.

  • PDF

Determination of brightener concentrations in Watt-type Ni Electroplating bath using dilution titration-cyclic voltammetry stripping (DT-CVS) (희석 적정-순환전류전압법을 이용한 와트욕 내부 광택제 농도 모니터링)

  • Choe, Seung-Hoe;Gwon, Yeong-Hwan;Lee, Ju-Yeol;Kim, Man;Park, Yeong-Bae;Lee, Gyu-Hwan
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.30-30
    • /
    • 2018
  • 스마트 도금공장을 구축하기 위해서는 도금액 내부의 화학 물질 농도 변화를 측정할 수 있는 화학 센서 기술이 필수적으로 요구된다. 와트욕은 대표적인 고속 니켈 도금액 중 하나로 기본적으로 황산니켈, 염화니켈, 보릭산의 염과 함께 케리어(type-1 광택제), 광택제(type 2-광택제), 응력 제어제 등의 유기 첨가제로 구성되어 있다. 이러한 유기 첨가제는 전차된 니켈층의 두께 균일도, 조도, 미세 구조, 내부 응력 등 다양한 특성을 제어하며, 정밀한 농도 관리가 필수적으로 요구되나, 분석 기술의 부재로 인하여 지금까지도 대부분의 액관리는 할셀법이나 작업자의 경험에 의존하고 있다. Cyclic voltammetry stripping(CVS) 방법은 전기화학 분석 과정에서 나타나는 첨가제의 가속, 감속 특성 등과 여기에 수반되는 stripping peak의 변화를 이용하여 개별 첨가제의 농도를 측정하는 방법이며, 지금까지 인쇄회로기판의 비아필 공정, 전해 동박 제조, 반도체 배선 등 구리도금 산업 전반에 걸쳐 첨가제 관리에 효과적으로 적용되고 있다. 그러나 수소 발생으로 인한 stripping 효율 문제로 인하여 니켈, 주석, 아연 등 표준 환원 전위가 높은 금속 도금액 내부 첨가제 농도 측정은 아직 어려운 상황이다. 본 연구에서는 이 문제를 극복하기 위해 염소를 과량 첨가한 구리 도금액을 CVS 분석의 base 용액으로 이용하여 니켈 도금액 내부 여러 광택제 (polyetylene glycol(PEG) 계열, thiourea 계열, 2-butyne-1,4-diol 등) 농도를 측정하는 법을 제시하였다. 제시된 방법은 CVS 분석 과정에서 구리-염소 사이의 상호 작용으로 인해 생성되는 3가지 stripping peak의 상대적인 크기 변화가 첨가제 농도에 따라 영향을 받는다는 사실에 기반하였다. 본 연구에서는 여기에 관한 원인에 대해 고찰하였으며, 제시된 방법을 통해 광택제 계열 첨가제 농도 측정을 선택적으로 할 수 있다는 것을 증명하였다.

  • PDF