• Title/Summary/Keyword: 미세먼지집진

Search Result 47, Processing Time 0.025 seconds

Dust collection system optimization with air blowing and dust suction module (에어 블로어와 흡입기능을 가진 미세먼지 흡입시스템의 최적화)

  • Jeong, Wootae;Kwon, Soon-Bark;Ko, Sangwon;Park, Duckshin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.290-297
    • /
    • 2016
  • The performance of track cleaning trains to remove accumulated fine particulate matter in subway tunnels depends on the design of the suction system equipped under the train. To increase the efficiency of the suction system under the cleaning vehicle, this paper proposes a novel dust suction module equipped with both air blowing nozzles and a dust suction structure. Computational Fluid Dynamics (CFD) analysis with turbulent flow was conducted to optimize the dust suction system with a particle intake and blowing function. The optimal angle of the air blowing nozzle to maximize the dust removal rate was found to be 6 degrees. The performance of the track cleaning vehicle can be increased by at least 10 percent under an operation speed of 5km/h.

Size measurement of electrosprayed droplets using shadowgraph visualization method (Shadowgraph 가시화 기법을 활용한 정전분무액적의 크기 측정)

  • Oh, Min-Jeong;Kim, Sung-Hyun;Lee, Myong-Hwa
    • Particle and aerosol research
    • /
    • v.13 no.4
    • /
    • pp.151-158
    • /
    • 2017
  • Electrostatic precipitator is widely used to remove particulate matters in indoor air and industrial flue gas due to low pressure drop and high collection efficiency. However, it has a low collection efficiency for the submicrometer sized particles. Electrospraying is a potential method to increase the particle charging efficiency, which results in increased collection efficiency. Although particle charging efficiency is highly dependent upon droplet size, the effective measuring method of the droplets is still uncertain. Tap water was electrosprayed in this study, and the images of electrosprayed droplets were taken with a high speed camera coupled with several visualization methods in order to measure the droplets size. The droplet size distribution was determined by an image processing with an image-J program. As a result, a droplet measured by a laser visualization, had a half size of that by a Xenon light visualization. In addition, the experimentally measured droplet sizes were a good agreement with the predicted values suggested by $Fern{\acute{a}}ndez$ de la Mora and Loscertales(1994).

Development of Air Cleaning Roll-Filter for Improving IAQ in Subway (도시철도 객실 공기질 개선을 위한 롤필터 개발연구)

  • Kwon, Soon-Bark;Park, Duck-Shin;Cho, Young-Min;Kim, Jong-Bum;NanGoong, Seok;Han, Tae-Woo;Cho, Kwan-Hyun;Kim, Tae-Sung
    • Journal of the Korean Society for Railway
    • /
    • v.14 no.4
    • /
    • pp.313-319
    • /
    • 2011
  • In a modern society, various type of transportation modes are utilized, among them the subway system is the one of the main transportation mode which more than 7.21 million people ride a day in Seoul. Due to the increased interests on the indoor air quality (IAQ) of underground facilities, public concerns on IAQ of subway system are increasing also. Platform screen door (PSD) recently installed at the whole stations of Seoul subway and tunnel washing-out appeared to be effective in reducing particulate matters in the platform and tunnel. However there has not been any attempt to improve IAQ of subway cabin inside. Most technologies for removing airborne particulate matters are known to be difficult to adopt on the subway cabin due to the problem of maintenance cost. Therefore, the object of this study is a practical development of cabin air cleaning system which can reduce the concentration of airborne particles and harmful gases at the same time. In this paper, we focused on the development of particle removing system utilizing a roll-filter for increasing operating time of air filter. The prototype of system was designed and manufactured based on the numerical prediction results. For rollfilter device, 5 candidate filter materials were tested in point of particle collection efficiency and pressure drop. It was found that the electrically charged filter material showed the highest performance among them.

Study on the optimal design of floor exhaust system using computational fluid dynamics for subway platform (수치해석을 활용한 승강장 바닥배기 시스템 최적화 연구)

  • Namgung, Hyeong-Gyu;Park, Sechan;Kim, Minhae;Kim, Soo-Yeon;Kwon, Soon-Bark
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.2
    • /
    • pp.443-449
    • /
    • 2017
  • The imbalance of air supply and the exhaust on subway platforms has led to the installation of platform screen doors in underground subway stations. This imbalance causes the accumulation of pollutants on the platform and loss of comfort due to the lack of ventilation. In this study, a floor exhaust system was optimized using computational fluid dynamics (CFD) and an optimization program. The optimized floor exhaust system was manufactured and tested experimentally to evaluate the particle collection efficiency. CFX 17.0 and HEEDS were used to analyze the flow field and optimize the principal dimensions of the exhaust system. As a result of the three-step optimization, the optimized floor exhaust system had a total height of 1.78 m, pressure drop of 430 Pa, and particle collection capability of 61%. A fine dust particle collection experiment was conducted using a floor exhaust system that was manufactured at full scale based on the optimized design. The experiment indicated about 65% particle collection efficiency. Therefore, the optimized design can be applied to subway platforms to draw in exhaust air and remove particulate matter at the same time.

How to Evaluate the Combined Dust Removal Efficiency of Fine Dust in the Dust Collector (집진기 미세먼지의 복합제진효율 평가방법)

  • Kang, Il-Seo;Lee, Young-su;Kim, Dong-Hyun
    • Journal of Digital Convergence
    • /
    • v.20 no.2
    • /
    • pp.339-344
    • /
    • 2022
  • It is about how much fine dust can be efficiently removed with respect to the electric dust collector used in factories and large facilities. The results of evaluating the fine dust removal efficiency are as follows. At 10,000 V, Efficiency method I showed 68.1 %, and Efficiency method II was 58.6 %, which was lower than that of Efficiency method I. At 5,000 V, Efficiency method I showed 57.6%, and Efficiency method II showed 51.6%, which was lower than Efficiency method I. At 2,500 V, Efficiency method I showed 50.3%, and Efficiency method II showed 24.4%, which was lower than Efficiency method I. In case of Efficiency method I, it is the efficiency calculated by using the dust concentration before and after passing through the filter. Efficiency method II calculated Efficiency method II to measure the efficiency a little more accurately in the environment where the air after the filter and the polluted air are mixed. Efficiency method II showed lower efficiency than Efficiency method I. As a result of the electrostatic precipitator test, the dust collecting performance was highest at 10,000 V, followed by 5,000 V and 2,500 V in that order.

A Study Pressure drop Variance of Pulse interval, injection distance in Pulse-Jet Type Fabric Filter (충격기류식 여과집진장치의 펄스간격 및 분사거리에 따른 압력손실변화에 관한 연구)

  • 서정민;정찬호;최금찬;박정호
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.05b
    • /
    • pp.102-103
    • /
    • 2003
  • 최근 고도 경제성장으로 인한 공업화와 그에 따른 업종이 다양해짐에 따라 여기에 수반되어 발생되는 대기오염물질이 증가할 뿐만 아니라 종류도 여러가지로 다양해지고 있다. 대부분 산업공정에서 배출되는 미세먼지 입자는 기존의 집진장치로 거의 포집제거가 불가능하여 대부분이 대기중으로 방출되고 있는 실정이다. 분진 중에서도 입경 l$\mu\textrm{m}$이하의 분진들은 침강 속도가 작아 거의 gas와 동일한 거동을 하기 때문에 기관 또는 폐포에 침착하여 호흡기에 영향을 미치므로 그 발생량과 화학적 성상이 문제화되고 있는 추세이다. (중략)

  • PDF

Flow control of air blowing and vacuuming module using Coanda effect (코안다 효과를 이용한 에어 블로어와 흡입구의 유동 제어)

  • Jeong, Wootae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.115-121
    • /
    • 2017
  • The efficiency of railway track cleaning vehicle for eliminating fine particulate matter (PM10 and PM2.5) in a subway tunnel depends strongly on the structure of the air blowing and suction system installed under the train. To increase the efficiency of underbody suction system, this paper proposes a novel method to use the Coanda effect for the air blower and dust suction module. In particular, through Computational Fluid Dynamics (CFD) analysis, the flow control device induced by the Coanda effect enables an increase in the overall flow velocity and to stabilize the flow distribution of the suction module at a control angle of $90^{\circ}$. In addition, the flow velocity drop at the edge of the air knife-type blower can be improved by placing small inserts at the edge of the blower. Those 4 modular designs of the dust suction system can help remove the dust accumulated on the track and tunnel by optimizing the blowing and suction flows.

Optimization of an Ozone-based Advanced Oxidation Process for the Simultaneous Removal of Particulate Matters and Nitrogen Oxides in a Semiconductor Fabrication Process (반도체 제조공정 미세먼지-질소산화물 동시 저감을 위한 오존 고속산화공정 최적화 연구)

  • Uhm, Sunghyun;Lee, Seung Jun;Ko, Eun Ha;Hong, Gi Hoon;Hwang, Sangyeon
    • Applied Chemistry for Engineering
    • /
    • v.32 no.6
    • /
    • pp.659-663
    • /
    • 2021
  • 10 m3/min (CMM) multi-pollutants abatement system was successfully developed by effectively integrating ozone oxidation, wet scrubbing, and wet electrostatic precipitation for the simultaneous removal of particulate matters (PMs) and NOx in a semiconductor fabrication process. The sophisticated control and optimization of operating parameters were conducted to maximize the destruction and removal efficiency of NOx. In particular, the stability test of a wet electrostatic precipitator was carried out in parallel for 30 days to validate the reliability of core parts including a power supply. An O3/NO ratio, which is the most important operating parameter, was optimized to be about 1.5 and the optimization of wet scrubbing with a reducing agent made it possible to analyze the contribution of neutralization reaction.

Evaluation on the Removel Effect of $PM_{10} and PM_{2.5}$ by Operating the Dust Collection Train and the Washing Train (집진열차 및 살수차운영에 의한 지하철역 미세먼지 농도 저감효과 분석)

  • 김민영;김동일;조기찬;이연수;하광태
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.11a
    • /
    • pp.421-424
    • /
    • 2003
  • 서울지하철은 총연장 286.9km에 1일 4226회의 운행회수 그리고 대중교통수단 중 총 34.1%의 최다 수송분담율을 담당하고 있다. 서울시의 도심교통문제 해결 방안으로 시민들에게 대중교통 이용을 적극적으로 권장하고 있으나, 지하철 역사의 환경문제는 답보 상태를 유지하고 있는 것이 현실이다. 지하철내의 먼지문제는 이미 심각한 사회문제로 대두된 지 오래이며 이를 개선하기 위하여 지하철공사와 도시철도공사에서는 환기시스템의 개선, 환기 및 공기정화시설의 설치 그리고 잦은 물청소실시 등을 시행하여 오고 있어 그간 상당한 효과를 이룬 것도 사실이다. (중략)

  • PDF

Characteristics of Wind Speed and PM10 Concentration underneath Railway Trains (도시철도 차량 하부의 풍속 및 미세먼지 농도 특징)

  • Kim, Jong Bum;Woo, Sang Hee;Jang, Hong-Ryang;Chou, Jin-Won;Hwang, Moon Se;Park, Hyung-Koo;Yoon, Hwa Hyeon;Jung, Joon-Sig;Bae, Gwi-Nam
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.1
    • /
    • pp.11-19
    • /
    • 2017
  • Since operation of railway trains is a major source of particle pollution in tunnel air, a particle removal device can be an effective measure to remove wear particles. To obtain design conditions of the particle removal device that will be installed underneath the railway trains, the wind speed and particle concentration underneath the trains were investigated using a three-dimensional ultrasonic anemometer and a DustTrak aerosol monitor, respectively. The measurements were made for the trains running on Seoul Metropolitan Subway Line 5 on February 10, 2015. The data were analyzed according to the track geometry (straight, curved) and train speed pattern (acceleration, cruising, and deceleration) between stations. Train speed was also analyzed. The average wind speed and $PM_{10}$ concentration underneath the trains were ~30% of the train speed and ${\sim}200{\mu}g/m^3$ for both straight and curved sections. Average $PM_{10}$ concentration for deceleration sections was higher than that for acceleration sections.