• Title/Summary/Keyword: 무배선 통신

Search Result 9, Processing Time 0.028 seconds

Development of Communication Joint Tools for Implementing a Legacy-line Communication System in a Train (열차 내 무배선통신시스템 구축을 위한 통신연결장치 개발)

  • Kim, Hyun Sik;Park, Soo Hoon;Kang, Seog Geun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.4
    • /
    • pp.877-887
    • /
    • 2015
  • In this paper, a design of communication joint tools to implement a legacy-line communication (LLC) system, which exploits various conductive lines in a train, is presented. We develop two kinds of joint tools; one is a conductive joint tool (CJT) that is connected directly to the conventional lines and the other is the inductive joint tool (IJT) which connects the conventional lines indirectly using electromagnetic induction. As a result, the practical experiment of data communication confirms that an LLC system with the developed joint tools has a transmission rate more than 20 Mbps in the distance of 200 m away. In addition, an environmental durability test shows that the joint tools operate stably in an extreme environmenal variation. It is, therefore, considered that the developed joint tools are very useful to implement a communication network in the train working currently.

A Powerline-based Legacy-line Communication System for Implementation of a Communication Network in Ship (선박 내 통신네트워크 구축을 위한 전력선 기반 무배선통신시스템)

  • Kim, Hyun-Sik;Kang, Seog Geun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.8
    • /
    • pp.1831-1838
    • /
    • 2015
  • In this paper, a method of implementing a communication network in ship, which exploits a powerline-based legacy-line communication system (LLC), is presented. We develop an inductive coupling unit and a multi-interface device to connect a data communication terminal to the powerline. As a result of operation tests for the ship under working, the implemented LLC shows a transmission rate of at least 25.8 Mbps in the distance of 200 m away with 100% success rate. Thus, the system can be a useful alternative to implement a communication network in ship without additional channels. Being easy to be implemented and supporting various interfaces for data communication, the presented system will be very effective when a real-time monitoring system is launched in future digital ship.

Study on the Design of Customer Premise Facilities for Homenetworking Infrastructure (홈네트워크 구축을 댁내배선 설계연구)

  • 이영환;이상무;조평동
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.10a
    • /
    • pp.789-792
    • /
    • 2003
  • 홈네트워크(Home Network)는 일반 가정의 PC 및 주변기기, 정보기기, 디지털 가전제품 등을 단일 프로토콜로 제어해 가정내 디지털 기기간에 정보전달과 정보공유를 자유롭게 한다는 개념이다. 최근 정보통신 서비스가 대용량 고속화 및 멀티미디어화되고 일반 주거 지역으로의 유입 및 네트워크 설비 구축이 활성화되면서 기존의 전화망에 의한 단순 음성통신 또는 데이터 통신 환경과는 다른시설 패러다임이 이루어지고 있다. 이에 본 논문에서는 먼저 홈네트워크를 구성하기 위한 유무선 기술에 대하여 조사 분석, 홈네트워크 선로설비 구성시 요구되는 기자재중 케이블에 대하여 조사하였으며 이를 바탕으로 홈네트워크를 구축하기 위한 댁내배선 설계에 대하여 작성하였다.

  • PDF

Performance analysis of legacy line communication using high current powerlines in midrange wind turbines (중형급 풍력 발전기내 전력선을 이용한 무배선 통신 성능분석)

  • Kim, Kyoung-Hwa;Jeong, Seong-Uk;Nam, Seung-Yun;Kim, Hyun-Sik;Sohn, Kyung-Rak
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.4
    • /
    • pp.336-341
    • /
    • 2016
  • This paper presents an implementation of a communication network in wind turbines, which exploits the power-line communication system (PLC). We used an inductive coupling unit and a multi-interface device to connect a data-communication terminal to the power line, to ensure that stable communication was possible at various electric current and voltage values of the generator. The results of the operation tests conducted on an operational wind turbine showed that the implemented PLC demonstrated a transmission rate of at least 43 Mbps with a 100% success rate. Moreover, a real-time image was transmitted. Thus, the system could be a useful alternative for implementing a communication network in wind turbines that does not require additional channels. Since the presented system is easy to implement, and can support various interfaces for data communication, it will be quite useful when a real-time monitoring system is launched in wind turbines.

Development of Bypass Unit for Ship Area Network Based on Legacy-line Communication (무배선 통신을 위한 선박 네트워크용 바이패스 장치 개발)

  • Jun, Ho-Ik;Kim, Hyun-Sik;Jung, Kyun Sik;Sohn, Kyung-Rak
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.3
    • /
    • pp.292-297
    • /
    • 2015
  • In this paper, we reported the bypass unit for ship area networks in order to detour the communication failure regions and poor communication links. The device was composed of three parts of circuits for power cut-off, protection, and coupling transformer. Since the coupling transformer exerts a dominant influence on the performance of the by-pass unit, we have tried to find the optimal magnetic core materials and its dimensions. The prototype was passed through the performance test of insertion loss, temperature, and vibration characteristics. The insertion loss was around -2 dB in the range of 90 kHz ~ 30 MHz and the average communication speed was 59.2 Mbps in the laboratory. A pilot communication test using the developed tool was conducted in the training ship of the Korea Maritime and Ocean University. As a results of experiment, we showed that the wired communication among the heterogeneous-links in the ship area networks are possible by the bypass unit and also a high speed communication services are available in ~ Mbps by using a power-line.

Analysis on the Elements of Space and Environment for Customer Premises Facilities (댁내통신설비 설치공간 및 환경요소 체계 분석)

  • Lee, S.M.;Lee, Y.H.;Cho, P.D.
    • Electronics and Telecommunications Trends
    • /
    • v.16 no.5 s.71
    • /
    • pp.151-160
    • /
    • 2001
  • 본 논문은 댁내통신설비 구축에 필요한 설치 공간과 운용조건에 해당하는 환경 요소들에 대한 체계를 분석하여 정리한 것이다. 댁내통신설비기술의 부문으로서 구조화된 배선시스템이 그 중추를 이루고 있으며, 이에 필요한 광커넥터, 트랜시버 등 핵심 접속 자재, 보호기, 복합 세대단자함 또는 게이트웨이 등이 개발되고 있다. 이에 더하여 댁내통신설비의 근간이 되는 배선시스템을 최적으로 수용하고 운용할 수 있는 공간과 환경이 갖추어져야 한다. 본 논문에서는 이러한 공간과 환경에 대하여 국내외 표준자료와 기술규격 자료, 설치시방서와 연구논문 등을 분석하여 아직 체계적으로 정리되어 있지 않은 공간과 환경 요소들을 분류 정리한 것이다.

Design Study for Power Integrity in Mobile Devices (모바일 기기의 전원 무결성을 위한 설계 연구)

  • Sa, Gi-Dong;Lim, Yeong-Seog
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.5
    • /
    • pp.927-934
    • /
    • 2019
  • Recently, mobile devices have evolved into small computers with various functions according to user requirements. Careful attention must be paid to the design of the power supply network for the stable operation of the application processor (AP), the wireless communication modem, the high performance camera, and the various interfaces of the mobile device to implement various functions of the mobile device. In this paper, we analyzed and verified the method of optimizing the design parameters such as the position, capacity, and number of decoupling capacitors to meet the target impedance required by the driver IC chip to ensure the stability of the power supply network of mobile devices that should be designed as wiring type due to mounting density limitation. The proposed wired power supply network design method can be applied to various applications including high-speed signal transmission line in addition to mobile applications.

Performance Analysis of the Powerline Communication for Condition Monitoring System of an MW Class Offshore Wind Turbine's Nacelle (MW급 해상풍력발전기 나셀의 상태 감시를 위한 전력선 통신 성능 분석)

  • Sohn, Kyung-Rak;Kim, Kyoung-Hwa;Jeong, Seong-Uk;Nam, Seung-Yun;Kim, Hyun-Sik
    • Journal of Navigation and Port Research
    • /
    • v.40 no.3
    • /
    • pp.159-164
    • /
    • 2016
  • The goal of this study is to implement a communication system that can monitor the status of the nacelle using the power cable itself, without the dedicated communication lines such as an UTP cable and optical fiber for the offshore wind turbine. An inductive coupling powerline communication system for a MW class offshore wind turbine was proposed and its communication performance was demonstrated. The inductive couplers was designed for operation at up to 500 A using a ferrite composite materials. Field test was carried out on the wind farms of Jeju island. Using the iperf communication test program, we have obtained more than 15 Mbps data transmission rate through the 100 m power cable that was installed between the nacelle and the bottom of the power converter. In the data transmission stability test for a week, there was no failure ever. The minimum transmission rate was 15 Mbps and the average data rate was about 20 Mbps. Next, we have installed an infrared camera inside the nacelle in order to measure the temperature distribution and variation of the nacelle. The real-time thermal image taken by the camera was successfully sent to the monitoring system without error.

Pin Distribute Method of Twist Cable at Military Unmanned Vehicle Wiring Unit Connector (군용 무인 이동체 배선장치 커넥터에서 트위스트 케이블 핀 배치 최적화 방안)

  • Eun, Hee-hyun;Roh, Dong-gyu;Kwak, Gyu-min;Kim, Jae-seung;Lee, Chul
    • Journal of Advanced Navigation Technology
    • /
    • v.24 no.4
    • /
    • pp.245-250
    • /
    • 2020
  • Currently, unmanned military vehicles under development in Korea have more devices to carry out various missions, and interface cables between them are also increasing. In addition, due to a small space problem inside the unmanned vehicle, devices are required to be miniaturized and integrated. For two reasons, connectors also need to be selected, which makes them vulnerable to noise due to the closer distance between the pins. In this paper, we analyzed how much the magnetic field produced by noise at the connector pin where cable twist is released affects the surrounding pin and presented the guide for optimal pin placement. First, the effect of magnetic field is greater than the crosstalk between pin and pin. Second, the magnetic field on both sides between + and - is strong when approaching one step with noise source. Third, the magnetic field strength is improved when setting the ground pin as the ground pin between the noise and the original signal when approaching the A noise source and the two steps. Fourth, in the case of a differential mode communication, the optimal placement area of the sensitive signal was presented according to positions Tx± and Rx±.