• Title/Summary/Keyword: 무구속

Search Result 61, Processing Time 0.024 seconds

A Development of Wrist type Monitoring System for Smart Home Healthcare (스마트홈의 헬스케어를 위한 손목형 생체신호 감시 장치 개발)

  • Lee, Gun-Ki;Lee, Ju-Won;Jeong, Won-Geun;Lee, Han-Wook;Jang, Jun-Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.12
    • /
    • pp.2349-2354
    • /
    • 2006
  • Due to technological developments and the joint effect of both new social and economic needs and constraints, telemedicine is expanding rapidly through a variety of applications. Especially, owing to the rapid aging of society and increasing the wish for well being life, we take interest in health care services for people with special needs who wish to remain independent and living in their own home. We have focused on tole-monitoring to real-time medical signal and environment factor which is an influence on medical signal. We monitor the six signal(medical signal and environment factor), and transmit that signal to computer on bluetooth network. We get the information after using the some digital signal processing system, and display that information on the real-time monitoring system. We developed the measurer as portable type in older to non-restrained monitor.

Design of Unconstrained Baby Monitoring System Based on a Doppler Radar and an Air Mattress (도플러 레이더와 에어 매트리스를 이용한 무구속 방식의 신생아 감시 장치 설계)

  • Yang, Seong-Soo;Cho, Sung-Pil;Park, Ho-Dong;Lee, Kyoung-Joung
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.6
    • /
    • pp.177-184
    • /
    • 2014
  • Continuous monitoring of heart rates and respiratory rates for newborns or infants is very important since the abnormal breathing and heart problems can threaten the life of newborns or infants. A noncontact baby monitoring system based on a Doppler radar and an air mattress was designed. The Doppler radar was used to acquire respiratory signals and the air mattress was employed to obtain heart rates. The performance of the designed system was evaluated using a commercialized infant simulator ($Simbaby^{TM}$) and a respiration belt transducer was used to measure respiration rates as a reference. Results for respiratory rates revealed that the correlation coefficients between I-and Q-channel and the respiration belt were 0.84 and 0.91 and the mean ${\pm}$ standard deviations of errors between them were $1.66{\pm}1.92$ (bpm) and $0.88{\pm}1.65$ (bpm). Heart rates showed that the correlation coefficient between air mattress and set value of the simulator was 0.73 and the mean ${\pm}$ standard deviation of errors between them was $1.09{\pm}3.45$ (bpm). These results indicate that the designed system holds the potential as an effective monitoring tool for continuous monitoring heart rates and respiratory rates of newborns or infants.

Discrimination system using weight distribution patten (체중 분포 패턴을 이용한 자세 판별 시스템)

  • Kim, Hyeon-Woo;Ahn, Byeung-Gu;Jeong, Do-Un
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.374-375
    • /
    • 2015
  • Modern people is generated as musculoskeletal diseases due to incorrect posture and habit. In the case of persistent abnormal posture outbreak inconvenient to musculoskeletal diseases in daily life. musculoskeletal diseases, which began as fatigue, pain, sensory paralysis, convulsions are developed symptoms of movement disorders, depression, deformities, etc. In this paper, the unrestrained abnormal posture and habit of occurring in the seat life, have implemented a system which can be determined in less unconscious way. By placing eight pressure sensors in the seat part, determines the posture over the distribution of the weight, it is possible to determine one normal posture and eight abnormal posture that occurs frequently in daily life. To evaluate the performance of the implemented system, the attitude determination experiment was performed. The results confirmed the high performance of 97%.

  • PDF

A Study on Intrinsic Noise of Capacitively Coupled Active Electrode (용량성 결합 능동 전극의 내부 잡음 분석)

  • Lim, Yong-Gyu
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.13 no.1
    • /
    • pp.44-49
    • /
    • 2012
  • The indirect-contact ECG measurement is a newly developed method for unconstrained and nonconscious measurement in daily Life. This study is the first step to reducing the large background noise appearing in indirect-contact ECG. This study built the thermal noise model of capacitively coupled active electrode which is used in indirect-contact ECG. The results show that the level of thermal noise estimated by the thermal noise model is much the same as that of actual background noise for the capacitively coupled active electrode alone. By applying the actual electrical properties of a sample cotton cloth to the thermal noise model, the theoretical level of thermal noise in the indirect-contact ECG was estimated. The results also show that the level of op-amp's intrinsic noise is so small that it can be negligible in comparison with thermal noise of resistors. The relationship between the level of thermal noise and the resistance of the bias resistor was derived, and it is the base for the further study how to choice the optimal resistance for the bias resistor.

A Study on comnon-mode-driven shield for capacitive coupling active electrode (용량성 결합 능동 전극의 공통 모드 구동 차폐)

  • Lim, Yong-Gyu
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.13 no.4
    • /
    • pp.201-206
    • /
    • 2012
  • The indirect-contact ECG measurement is a newly developed method for unconstrained and nonconscious measurement in daily life. This study introduced a new method of electrode circuit design developed for reducing the 60Hz power line noise observed at the indirect-contact ECG measurement. By the introduced common-mode-driven shielding, the voltage of the electrical shield surrounding the capacitive coupling electrode is maintained at the same as the common mode voltage. Though the method cannot reduce the level of common mode voltage itself, that reduces effectively the differential mode noise converted from the common mode voltage by the difference of cloth impedance between the two capacitive coupling electrode. The experiment results using the actual indirect-contact ECG showed that the 60Hz power line noise was reduced remarkably though the reduction ratio was smaller than the expected by the theory. Especially, the reduction ratio became large for the large difference of cloth. It is expected that the introduced method is useful for reducing the power line noise under condition of poor electrical grounding.

A Design of Kidney Diseases Diagnosis Method Using Formant Frequency Bandwidth Extraction and Analysis (포먼트 주파수 대역폭 추출 및 분석을 이용한 신장 질환 진단 방법의 설계)

  • Kim, Bong-Hyun;Cho, Dong-Uk
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.10B
    • /
    • pp.1062-1069
    • /
    • 2009
  • The kidney diseases is a big social problem what is suffering sequela of metabolic syndrome due to obesity. Therefore, it is most important that early to take the appropriate action; it does not have symptoms Abnormalities of the kidney. With this, in mind, this paper wish to propose the method to can diagnosis by non self-consciousness, non-imprisonment, analgesia of kidney disease through the voice analysis. To configure the entire system is developed to combines the voice analysis, watching the face color and this paper is designed the method to diagnosis kidney disease based on labial. In this paper, organized each kidney disease patients and healthy people group and we would like to analyze, compare with output in experiment morphology analysis and numerical value analysis of voice information. Secondly, auscultation theory of Oriental medicine and linguistic, phonetics analyze out interrelation to extraction peculiar elements of kidney about voice deduction deduced relation of the first formants frequency. Such result of experimentation, deduced widely to be formed the first formants frequency bandwidth value of kidney patients group than normal group. Finally, diagnosing an kidney diseases in only labial sound, calculated about misdiagnosis probability.

Non-restraint Master Interface of Minimally Invasive Surgical Robot Using Hand Motion Capture (손동작 영상획득을 이용한 최소침습수술로봇 무구속 마스터 인터페이스)

  • Jang, Ik-Gyu
    • Journal of Biomedical Engineering Research
    • /
    • v.37 no.3
    • /
    • pp.105-111
    • /
    • 2016
  • Introduction: Surgical robot is the alternative instrument that substitutes the difficult and precise surgical operation; should have intuitiveness operationally to transfer natural motions. There are limitations of hand motion derived from contacting mechanical handle in the surgical robot master interface such as mechanical singularity, isotropy, coupling problems. In this paper, we will confirm and verify the feasibility of intuitive Non-restraint master interface which tracking the hand motion using infra-red camera and only 3 reflective markers without the hardware handle for the surgical robot master interface. Materials & methods: We configured S/W and H/W system; arranged 6 infra-red cameras and attached 3 reflective markers on hands for measuring 3 dimensional coordinate then we find the 7 motions of grasp, yaw, pitch, roll, px, py, pz. And we connected Virtual-Master to the slave surgical robot(Laparobot) and observed the feasibility. To verify the result of motion, we compare the result of Non-restraint master and that of clinometer (and protractor) through measuring 0~180 degree, 10degree interval, 1000 samples and recorded standard deviation stands for error rate of the value. Results: We confirmed that the average angle values of Non-restraint master interface is accurately corresponds to the result of clinometer (and protractor) and have low error rates during motion. Investigation & Conclusion: In this paper, we confirmed the feasibility and accuracy of 3D Non-restraint master interface that can offer the intuitive motion of non-contact hardware handle. As a result, we can expect the high intuitiveness, dexterousness of surgical robot.

Implementation of Carpal Tunnel Syndrome Prevention System Using Arduino (Arduino를 활용한 손목 터널 증후군 예방 시스템 구현)

  • Hwang, Woo-Jin;Woo, Youn-Ho;Noh, Yun-Hong;Jeong, Do-Un
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.531-532
    • /
    • 2016
  • Carpal tunnel syndrome, carpal tunnel becomes part of a narrower median nerve pain occurs pressed. How a stable wrist stretch for the prevention of carpal tunnel syndrome is required, it should life guides to fit the user is provided. In this research, users themselves recognize the risk of carpal tunnel syndrome, to be able to stretch, it implements the application. Application, based on the usage time set by the user, executes the alarm and lock. At this time, the user may utilize arduino and inertia sensor, it is possible to wrist stretch, to analyze usage patterns, it is possible to provide a medical information and life guides to suit the user. Data using Bluetooth 4.0 communication has been to meet the runaway. In order to evaluate the mounted system, targeting four subjects, the time and the touch frequency of usage of the 3-day smartphone measured, as a result of the questionnaire, it reduces the frequency of use of smartphones, a positive it was possible to prove the effect.

  • PDF

Artificial intelligence-based blood pressure prediction using photoplethysmography signals

  • Yonghee Lee;YongWan Ju;Jundong Lee
    • Journal of the Korea Society of Computer and Information
    • /
    • v.28 no.11
    • /
    • pp.155-160
    • /
    • 2023
  • This paper presents a method for predicting blood pressure using the photoplethysmography signals. First, after measuring the optical blood flow signal, artifacts are removed through a preprocessing process, and a signal for learning is obtained. In addition, weight and height, which affect blood pressure, are measured as additional information. Next, a system is built to estimate systolic and diastolic blood pressure by learning the photoplethysmography signals, height, and weight as input variables through an artificial intelligence algorithm. The constructed system predicts the systolic and diastolic blood pressures using the inputs. The proposed method can continuously predict blood pressure in real time by receiving photoplethysmography signals that reflect the state of the heart and blood vessels, and the height and weight of the subject in an unconstrained method. In order to confirm the usefulness of the artificial intelligence-based blood pressure prediction system presented in this study, the usefulness of the results is verified by comparing the measured blood pressure with the predicted blood pressure.

A Study on Performance of Indirect-contact Driven-right-leg Ground in Indirect-contact ECG Measurement (간접접촉 심전도 측정에서의 간접접촉 오른발 구동 접지 성능에 대한 연구)

  • Lim, Yong-Gyu;Kim, Ko-Keun;Park, Kwang-Suk
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.9 no.4
    • /
    • pp.280-287
    • /
    • 2008
  • For the reduction of common-mode noise level in Indirect-contact ECG (IDC-ECG) measurement a driven-right-leg grounding method was a lied to the IDC-ECG. Because the IDC-ECG does not require any direct contact between the electrodes and the human skin. it is adequate for un-constraining long-term ECG measurement at home and its various applications are now under development. However, larger 60 Hz noise induced by power line a ears in IDC-BCG than in conventional ECG, that is a restriction of IDC-ECG a application. In this study, the driven-right-leg ground which has been used in conventional direct-contact ECG, was adapted to the IDC-ECG measurement by feedback of the inversion of amplified common-mode noise to the body through the conductive fertile laid on the chair seat By this study, indirect-contact driven-right-leg ground was developed and it was shown to work stably. It was shown that the level of 60Hz power line noise was reduced to about -40 dB when the driven-right-leg gain was 1000. This study shows that we can extend the upper limit of the frequency band of IDC-ECG to 100Hz from 30Hz which is conventional upper limit in IDC-ECG, and we can raise the ground impedance between the body and conductive textile. So it is expected that the application area of the IDC-ECG will be extended by the results of this study.

  • PDF