• Title/Summary/Keyword: 목표강도

Search Result 493, Processing Time 0.034 seconds

A Study on the physical characteristics of foaming glass by recycling waste glass (재생발포유리의 물리적 특성에 관한 연구)

  • Kim Hyung-Ju;Chang Pil-Kyu;Choi Chang-Ha;Lee Soo-Wohn;Cho Hae-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.6 no.6
    • /
    • pp.473-477
    • /
    • 2005
  • In the study of foaming a general waste glass, sample 1 to 5 were made in a various foaming conditions, measurements of pH, density, compressive strength, thermal conductivity, and the sound absorption rate were carried out. Sample I showed the most small pore, and sample 5 showed pores of 3 times larger than that of sample 1. In terms of pore size, Sample 5 was foamed mostly well, but except lower density compressive strength, efficiency of sound absorption, testing in sound room were obtained below the minimum values is lower. In the case of Sample 1 it showed $0.58g/cm^3$, but the final target value was $0.8g/cm^3$. In the case of compressive strength it showed $22kg/cm^3$, which is above value of the final target. The efficiency of sound absorption of Sample 1 showed NRC 0.68, which is close to the final target of NRC 0.7.

  • PDF

Development of Domestic Pattern Frame Method for Skid Resistance Pavement (미끄럼 방지 도로 포장을 위한 국내형 패턴 프레임 공법 개발)

  • Lee, TaeMin;Choi, HaJin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.2
    • /
    • pp.58-65
    • /
    • 2021
  • As increasing social needs of pavement maintenance, pattern frame method has been constructed in Korea. The pattern frame not only increases the skid resistance of pavements but also improve the scenery. However, construction of the pattern frame currently relies on imported materials. In this paper, we localize the materials used in pattern frame and conduct performance verification on them. The important performance indicators are the adhesion strength of undercoating materials and the skid resistance of finished pattern frames. The adhesion strength was targeted at 1.4MPa, and the localization alternative material met the target performance with 2.35MPa, the skid resistance performance was targeted at 40BPN, and the localization alternative material met the target performance with 75BPN. In the case of localized materials, approximately 40% cost reduction (per 1m2)compared to imported materials was confirmed.

Basic Study on the Serviceability of Structural Concrete according to Replacement Ratio of Recycled Aggregate (순환굵은골재 치환율에 따른 구조용 콘크리트 사용성에 관한 기초적 연구)

  • Jang, Hyun-Suk;Hong, Seong-Uk;Lee, Young-Taeg;Cho, Young-Sang
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.521-524
    • /
    • 2011
  • 본 논문에서는 순환골재에 대하여 구조용 적용성 검증을 목표로 하였으며, 천연골재와 순환골재 치환율에 따른 압축파괴강도와 압축강도증가에 따른 파속도의 상관관계를 비교 분석하였다. 설계기준강도 21, 27, 35MPa에 순환굵은골재 치환율 0, 30, 50, 100%를 적용하여 설계기준강도에 따른 순환굵은골재 치환율의 배합을 총 12가지로 설정하였다. 재령160일까지의 압축파괴강도의 변화를 대기양생 공시체, 수중 양생공시체 그리고 코어공시체를 이용하여 비교하였고, 모의부재(800${\times}$800${\times}$200mm)를 통하여 재령160일까지의 초음파속도를 측정하였다. 압축파괴실험을 통하여 취득한 데이터를 비교해 본 결과 순환굵은골재 치환율에 따른 강도저하현상은 나타나지 않았다. 또한, 재령일에 따른 강도 증가와 함께 파속도도 같이 증가함을 알 수 있었다.

  • PDF

Strength Prediction of Vehicle Body Using Simple FE Model (단순 보 모델을 이용한 차량 차체의 강도해석 기술)

  • 강성종
    • Journal of the KSME
    • /
    • v.35 no.8
    • /
    • pp.709-715
    • /
    • 1995
  • 날로 그 중요성이 대두되고 있는 환경보존 문제에 능동적으로 대응하고 여러 계층 소비자의 안 전도, 쾌적성 등에 관련된 요구, 성능의 수준향상에 효과적으로 대처하기 위해서는 차량의 경량화 기술이 가장 먼저 선행되어야 할 과제이다. 경량화를 추구하는 방법은 최적설계 개념을 이용한 구조합리화에 의한 방법과 알루미늄, 강화 플라스틱 등 신소재 대체에 의한 방법이 병행 연구 되고 있다. 이 글에서는 구조합리화를 통한 경량화 목표를 달성하기 위해 설계 초기 단계에 활용 가능한 단순 보 모델 개발의 필요성에 관해 언급하고 실차의 도어 측면 붕괴강도(door side intrusion strength), 루프 붕괴강도 (roof crush strength) 해석을 위한 단순 보 모델 개발에 관해 소개하고자 한다.

  • PDF

Influence of Blast Furnace Slag and Anhydrite on Strength of Shotcrete (고로슬래그와 무수석고가 숏크리트의 강도에 미치는 영향)

  • Ryu, Sung-Hee;Shin, Kyung-Joon;Kim, Yun-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.1
    • /
    • pp.87-95
    • /
    • 2012
  • This study investigated the compressive strength, flexural strength, setting time, and rebound when blast furnace slag and anhydrite, which are widely used mineral admixtures for concrete, are applied to shotcrete. When Ordinary Portland Cement (OPC) was replaced at a rate of 10% with blast furnace slag and anhydrite, the initial and final setting time requirements were all satisfied. However, when OPC was replaced at a rate of 20%, final setting was delayed, revealing that this mixture was not suitable for shotcrete. Compressive strength test results showed that the mixture with 10% OPC replacement rate met the target strength at 1 day and 28 days for permanent tunnel support usage. Particularly, the mixture designed with OPC replacement by blast furnace slag and anhydrite at rates of 5% showed the highest compressive strength. Rebound measurements revealed that this mixture exhibited excellent performance with 23% reduction in the rebound compared to the shotcrete that was produced with only OPC binder.

The Effect of Combinations of Electric Arc Furnace Slag and Lime Stone aggregates on Engineering Properties of Ultra High Strength Concrete with 80MPa (전기로 산화슬래그 잔골재와 석회암 골재의 조합사용이 80MPa급 초고강도 콘크리트의 공학적 특성에 미치는 영향)

  • Han, Min-Cheol;Moon, Byeong-Yong
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.3
    • /
    • pp.253-260
    • /
    • 2017
  • The aim of research is to investigate various physical properties of ultra high strength concrete of 80MPa class using a combination of limestone aggregate and electronic arc furnace oxidizing slag aggregate. For aggregate combinations, granite and limestone are used for coarse aggregate, granite and limestone are also used for fine aggregate. And also, limestone fine aggregate is replaced by electronic arc furnace oxidizing slag aggregate of 25% and 50%. Test results indicated that flowability and compressive strength increased when limestone fine aggregate was used compared to that using granite fine aggregate due to higher modulus of elasticity by limestone. Also substitution of electronic arc furnace oxidizing slag aggregate resulted in a decrease of compressive strength slightly. It is found that the use of electronic arc furnace oxidizing slag aggregate and limestone aggregate would be favorable for reducing the autogenous shrinkage by as much as 9~25%.

Application of Performance Based Mixture Design (PBMD) for High Strength Concrete (고강도 콘크리트의 성능기반형 배합설계방법)

  • Kim, Jang-Ho Jay;Oh, Il Sun;Phan, Duc Hung;Lee, Keun Sung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.6A
    • /
    • pp.561-572
    • /
    • 2010
  • This paper is a study about application of recently proposed Performance Based Mixture Design (PBMD) for design of high strength concrete (HSC) to obtain HSC mix proportion that satisfies required performances. The PBMD method which uses Satisfaction curve based on a Bayesian method is a performance oriented concrete mix proportion design procedure easily applicable to any condition and environment for a possible replacement to the current prescriptive design standards. Based on extensive experimental results obtained for various materials and performance parameters of HSC, the application feasibility of the developed PBMD procedure for HSC has been verified. Also, the proposed PBMD procedure has been used to perform application examples to obtain desired target performances of HSC with optimum concrete mixture proportions using locally available materials, local environmental conditions, and available concrete production technologies. The validity and precision of HSC mix proportion design obtained using the PBMD method is verified with the experimental and ACI presented results to check the feasibility for actual design usage.

An Experimental Study for Improving the Applicability of High-Strength Concrete (고강도 콘크리트의 실용성 향상을 위한 실험적 연구)

  • 유영찬;민병렬
    • Magazine of the Korea Concrete Institute
    • /
    • v.4 no.2
    • /
    • pp.83-92
    • /
    • 1992
  • 본 연구의 목적은 현장에서 구입 가능한 저품질의 재료를 사용한 일련의 실험을 통하여 28일 압축강도와 물\ulcorner시멘트비와 관계를 유출함으로써 고강도 콘크리트의 배합설계식을 얻기 위한 것이다. 목표슬럼프는 고층건물에서의 시공성을 고려하여 15$\pm$2cm로 하였으며 혼화제로는 고성능감수제를 사용하였다. 실험결과로부터 고강도콘크리트의 응력-변형도 특성을 비롯하여 탄성계수, 포아송비, 단위중량 등 고강도 콘크리트의 일반적인 재료성질을 얻었으며 본 연구에서 제안한 고강도콘크리트의 배합설계식은 국내현장조건을 고려한 실용식으로 고강도콘크리트으 설계 및 시공을 위한 기초자료로 사용 가능하다고 판단된다.

Effect of Compressive Strength and Curing Condition on the Direct Tensile Strength Properties of Ultra High Performance Concrete (압축강도 및 양생조건에 따른 초고성능 콘크리트의 직접인장강도 특성)

  • Park, Ji Woong;Lee, Gun Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.17 no.2
    • /
    • pp.175-181
    • /
    • 2017
  • The purpose of this study is evaluating the characteristics of tensile strength of UHPC and examining tensile performance of notched specimens by direct tensile test. For test variables, 120, 150, and 180MPa of target design standard strength were aimed at. With general water curing and $90^{\circ}C$ high temperature steam as curing conditions, the properties were reviewed. Overall, it was represented that the specimens of notch-type direct tensile strength concrete was effective in inducing central cracks compared with existing direct tension specimens. Through this, it was judged that data construction with high reliability was possible. Above all, in a graph of direct tensile strength and strain, in the case of steam curing at high temperature, there was great difference of initial tensile strength compared with water curing. As passing of ages, an aspect that the difference gradually decreased was shown. Maximum tensile strength was found to increase steadily with increasing age for all target design strengths in water curing, in the case of steam curing, the tendency to increase significantly due to the initial strength development effect at 7 days of age. The initial crack strength increases with age in case of underwater curing, in the case of steam curing, it was higher than that of water curing in 7 days, while the strength of 28 days was lowered. In this part, it is considered necessary to examine the arrangement condition of the steel fiber.

The Properties of Strength Development of High Volume Fly Ash Concrete with Reduction of Unit Water Content (단위수량 저감에 따른 하이볼륨 플라이애시 콘크리트의 강도 발현 특성)

  • Choi, Yun-Wang;Park, Man-Seok;Choi, Byung-Keol;Oh, Sung-Rok
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.2 no.1
    • /
    • pp.46-51
    • /
    • 2014
  • In this study, strength development properties of high volume fly ash concrete was evaluated through compressive strength of concrete with reduction of unit water content. And concrete specimens were prepared according to target strength 3 level and variation of unit water content. As a result, the improved fluidity were obtained as a result of the ball bearing action of the spherical, the electrostatic repulsion and the particle size distribution of fly ash particles in case of using more than 50% fly ash. Through this, the mixture of fly ash has been shown to reduce the amount of water required in concrete. Also, the early strength of high volume fly ash concrete with reduction of unit water content was improved more about 66% than general concrete mixture.