• Title/Summary/Keyword: 목업시험

Search Result 27, Processing Time 0.021 seconds

Engineering Properties of Concrete Mock-up Using Coal Gasification Slag as Fine Aggregate. (석탄가스화 발전슬래그를 잔골재로 사용한 콘크리트 Mock-up 부재의 공학적 특성)

  • Han, Jun-Hui;Lee, Young-Jun;Hyun, Seung-Yong;Han, Min-Cheol;Yoon, Ki-Won;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.159-160
    • /
    • 2018
  • In this study, the characteristics of the Mock-up test were reviewed to analyze the applicability of the coal gasification slag (CGS) from the integrated gasification combination Cycle (IGCC) to the concrete fine aggregate. The analysis shows that CGS and crushed sand mix is the best combination of CGS combined with about 50 % of CGS based on the effects of promoting liquidity and strength. This is expected to be a positive factor in securing the strength and flexibility of concrete given the optimal mix of CGS, and may also contribute to the improvement of quality.

  • PDF

Effect of Using Coal Gasification Slag as Fine Aggregate on Field Applicability of the Concrete through Mock-up Test (Mock up test를 통한 석탄가스화 발전슬래그를 잔골재로 사용한 콘크리트의 현장적용 가능성 분석)

  • Han, Jun Hui;Lee, Young Jun;Hyun, Seung Yong;Han, Min Cheol;Yoon, Ki Won;Han, Cheon Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.21-22
    • /
    • 2018
  • In this study, the characteristics of the Mock-up test were reviewed to analyze the applicability of the coal gasification slag (CGS) from the integrated gasification combination Cycle (IGCC) to the concrete fine aggregate. The analysis shows that CGS and crushed sand mix is the best combination of CGS combined with about 50 % of CGS based on the effects of promoting liquidity and strength. This is expected to be a positive factor in securing the strength and flexibility of concrete given the optimal mix of CGS, and may also contribute to the improvement of quality.

  • PDF

Outside -20℃ Exposure Time Impact on Early Frost Damage (외기온 -20℃에 노출시간 변화가 콘크리트의 초기동해 피해에 미치는 영향)

  • Choi, Yoon-Ho;Han, Jun-Hiu;Lee, Hyuk-Ju;Lee, Young-Jun;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.128-129
    • /
    • 2019
  • In this study, after exposing the normal concrete outside at $-20^{\circ}C$, when the above scored $20^{\circ}C$, we analyzed the limit points of the initial early frost damage to the concrete. As a result, it was confirmed that the degree of the upper part of the concrete when it was exposed outside the freezing point for 6 hours was zero.

  • PDF

차기정지궤도위성 태양전지판 무중력 전개시험장치 적합성 검토연구

  • Choe, Jeong-Su;Park, Jong-Seok;Kim, Hyeong-Wan
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.202-202
    • /
    • 2012
  • 항공우주연구원에 설치되어있는 태양전지판 무중력 전개시험장치는 지상 전개시험 시 지구 자중으로 인해 발생하는 하중과 마찰력을 상쇄하여 우주 궤도상에서 전개되는 것과 동일하게 태양전지판이 전개되도록 구성되어 있다. 이를 위해 에어베어링을 사용하여 전개 시 발생할 수 있는 전개방향으로의 마찰력을 상쇄하고, 지구 중력으로 인한 영향이 없도록 하기 위해 중력축에 대해 각 레일이 수평이 되도록 정밀하게 정렬되어야 한다. 본 연구에서는 천리안위성의 정밀조립 및 전개시험에 사용되었던 태양전지판 무중력 전개시험장치를 차기 정지궤도위성의 대형 태양전지판에 적용하였을 때에도 전개시험이 가능한 지를 카티아 디지털 목업 시뮬레이션을 사용해 모사하고 검토되어야 할 주요 사항들에 대해 분석하였다.

  • PDF

Study on Material Segregation of Grout and Filling Characteristic of Grouting for Post-Tensioned Concrete Beam (PC 그라우트의 재료분리 및 PC 빔 그라우팅 충전성에 관한 연구)

  • Lee, Jun-Ki;Choi, Joon-Ho;Yoon, Jeong-Seob;Cho, In-Sung
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.3
    • /
    • pp.419-426
    • /
    • 2010
  • This paper discusses a series of experiments including material improvement in order to ensure quality of grouting for the post-tensioned structure. In presstressed concrete, grouting refers to the construction procedure of filling empty space of duct enclosing the prestress tendons using cementitious material, To date, adequate quality control of the grouting has not been established in Korea because the relationship between the grouting and durability of post-tensioned structure is not well-recognized. The Korean standard does not consider the important material characteristic, wick effect, which is caused by tendons in the ducts, and furthermore current standard testing method does not quantify reasonable material segregation. As a result, the grout material, which satisfies the current material standards, may well exhibit excessive bleeding of water or shrinkage during construction. In this study, international codes and standards related to grouting were surveyed. The mix proportions of the constituents and novel admixtures were suggested to meet equivalently with these standards. Performance of this enhanced grout was compared with common domestic grouts using the international standard testing method. A series of mock-up specimens considering geometry of PC beam was constructed and grout flow pattern was observed as the grout was injected. It was observed that the grouting performance was highly influenced by material properties and filling characteristic can be varied depending on geometry of ducts.

Pyroshock measurement results of satellite mock-up for launch vehicle (발사체 목업(Mock-up) 위성의 파이로 충격 측정 결과)

  • Youn, S.H.;Jeong, H.K.;Seo, S.H.;Jang, Y.S.;Yi, Y.M.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.363-366
    • /
    • 2006
  • In general, pyrotechnic shock or pyroshock is generated during the operation of separation devices, which use explosives, such as pyrobolt, puronut, purocutter, linear shape charge, and so on. During the flight of launch vehicle, pyroshock is mainly produced at the events of satellite separation, fairing separation and stage separation. In this paper, characteristics of pyroshock are introduced in the first place and measured shock result data at the UMR of satellite mock-up during the separation tests of satellite and fairing are suggested. These results are compared with the suggested pyroshock test specification of satellite, and it finally confirms that the specification is reasonable for the qualification of satellite against pyroshock.

  • PDF

An Experimental Study on the Shrinkage Properties of Ultra-Low Shrinkage Concrete (초 저수축 콘크리트의 수축특성에 관한 실험적 연구)

  • Seo, Tae-Seok;Kim, Kang-Min;Lee, Hyun-Seunh
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.148-149
    • /
    • 2021
  • In Japan, ultra-low shrinkage concrete has been developed and commercialized to control drying shrinkage cracks to the limit. However, in the case of South Korea, the study on this technology has not yet been conducted in earnest. Therefore, the study was conducted for the development of ultra-low shrinkage concrete to control the drying shrinkage crack of concrete to the limit, and in this study, after determining the mixture of ultra-low shrinkage concrete, a wall type mock-up specimen was produced to observe the shrinkage behavior of ultra-low shrinkage concrete.

  • PDF

Measurement of Real Deformation Behavior in C-type Lng Mock-up Tank using Strain Gage (스트레인 게이지를 이용한 C-type LNG Mock-up 탱크 내조 실 변형 거동 측정)

  • Jung, Won-Do;Kim, Tae-Wook;Kim, Jeong-Hyeon;Lee, Do-Young;Chun, Min-Sung;Lee, Jae-Myung
    • Journal of Ocean Engineering and Technology
    • /
    • v.30 no.2
    • /
    • pp.117-124
    • /
    • 2016
  • A C-type LNG mock-up tank was constructed to evaluate the durability of the tank and its structural safety. An experimental strain analysis system equipped with strain gages was designed to investigate the structural behavior of the inner tank at a high hydraulic pressure. In addition, the insulation used in the space between the inner tank and outer tank had a compressive strength and the inner tank thickness of the cylindrical shell and hemisphere was 4.0 mm, which was designed to be thinner than the existing rules. The strains on the inner tank were measured with increasing pressure, and these measurements were compared and analyzed at the strain gage attachment points.

Autogenous Shrinkage Mock-up Test of High Performance Concrete by Emulsified Refined Cooking Oil (유화처리 정제식용유를 사용한 고성능 콘크리트의 자기수축 Mock-up 실험)

  • Jo, Man-Ki;Han, Cheon-Goo
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.3
    • /
    • pp.307-315
    • /
    • 2016
  • The aim of this research is analyzing the fundamental properties and autogenous shrinkage reducing performance of 70 and 100MPa grade high performance concrete including emusified refined cooking oil(ERCO) under the mock-up conditions. As a results of experiment, the mixture contained 0.5% of ERCO showed slightly decreased slump flow while the slump was increased and segregation resistance performance was improved as 2.5 of EIS. For air content, all mixtures satisfied target air content with increased unit weight and delayed setting time with ERCO addition. In the case of compressive strength, when ERCO was added 0.5%, the result of approximately 5 to 10% of increased compressive strength was observed. For the autogenous shrinkage, ERCO contributed on 20-30% of shrinkage reducing performance comparing to Plain mixture without ERCO. It is considered that capillary pore filling action of soap particles occurred by the reaction of ERCO in cement paste between fatty aicd and calcium hydroxide contributed the shrinkage reducing performance. Based on these mock-up test results, application of the high performance concrete mixture with ERCO on CFT actual structure was decided.

A study on the implementation of door control unit for railway trains operable at low and high platforms

  • Young-Seok Cho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.28 no.7
    • /
    • pp.1-9
    • /
    • 2023
  • Currently, as the demand for stops in the urban increases resulting from an increase in the supply of express trains, the development of trains capable of operating both high-floor platforms in the urban and low-floor platforms in the suburbs is required. In this paper, we studied the design and fabrication of a controller for train doors that consists of low and high steps as a plug-in type door mechanism and thus can be used on low and high platforms. This DCU H/W was designed and implemented using 32 bit MCU to control 4 motors, 33 digital inputs and 16 digital outputs. In addition, based on the software life cycle of EN50128, 2 items of operation requirements and 12 items of control requirements were derived, and then they were designed and implemented as operation SW. The implemented SW was tested for each requirement. As a result, we performed tests on 13 items that could be tested in the mock-up out of 14 total requirement items and showed that the requirements were satisfied.