• Title/Summary/Keyword: 모의 정확도 향상

Search Result 741, Processing Time 0.051 seconds

A Study of Image Quality and Exposed Dose by Field Size Changing on CBCT (CBCT 촬영 시 조사야 조절에 따른 영상의 최적화 및 피폭선량에 관한 고찰)

  • Bang, Seung Jae;Kim, Young Yeon;Jeong, Il Seon;Kim, Jeong Soo;Kim, Young Gon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.175-180
    • /
    • 2013
  • Purpose: Modern radiation therapy technique such as IGRT has become a routine clinical practice on LINAC for decrease patient's set-up error. CBCT can be used to adjust patient set-up error and treat patient more accurately. The Purpose of this study is to evaluate field size of CBCT for improving Image quality and suggest reference date of CBCT field size. Materials and Methods: Image date were acquired using KV CBCT and Catphan phantom (Half fan and full fan mode were scanned from 2 ~16 cm, at intervals of 2 cm). Field size were categorized by Small field size (2 cm, 4 cm), Medium field size (8 cm, 10 cm), Large field size (more than 14 cm) and evaluate. To estimated the CTDi using CTDi phantom and Ion chamber. Results: CT number linearity of Small and Large field size are greater than Medium field size. Spatial resolution are not significantly different without Small field size. But half fan mode is more different than full fan mode. In full fan, except Medium field size, all field size exceed recommendation for HU uniformity. But half pan has stability for all field except Small field size. CTDi makes radical sign function graph in Medium field size. Conclusion: The worst result was given by Small field size for Image quality and practically. Medium field size can be useful to prevent patient from radiation exposure and give better Image quality. So this study recommends that Medium field size (8~10 cm) is more suitable for CBCT.

  • PDF

Analysis of The Adverse Events Following Immunization of the National Compensation Program and the Surveillance System in Korea, 1995~2000 (1995~2000년 예방접종 후 이상반응 사례 분석 - 국가보상 신청 사례와 예방접종 후 이상반응 감시체계 보고 사례를 중심으로 -)

  • Lee, Hong Jue;Sohn, Young Mo;Kim, Joung Soon;Kim, Young Taek;Lee, Jong Gu;Choi, Bo Youl
    • Pediatric Infection and Vaccine
    • /
    • v.8 no.2
    • /
    • pp.135-149
    • /
    • 2001
  • Purpose : To describe the characteristics of the claims for compensation and the methodology of investigations concerning adverse events following immunization(AEFI) and epidemiologic characteristics of the AEFI. From these results, to give a suggestion for improving AEFI surveillance system, consequently to stabilize National Immunization Program. Methods : Totally 61 cases were reported to the National Compensation Program and surveillance system of AEFI from 1995 to 2000. Documents from National Compensation Program, medical records and epidemiologic investigation reports of the cases were collected and analyzed. Results : The number of reported cases was 12 in 1995, 3 in 1996, 12 in 1998, 5 in 1999, and 29 in 2000, respectively. That of deaths was 24(39.3%) and 16 cases among them were autopsied(66.7%). That of claims for compensation was 36 and 17 cases among them were compensated(47.2%). The proportion of claim was lower in 1999~2000 than in 1995~1998, but proportion of compensation increased. Although proportion of investigation was lower in 1999~2000 than in 1995~1998, cases which were not epidemiologically investigated, decreased. The epidemiologic investigation launched within 24 hours after report increased from 25% in 1995~1998 to 48.3% in 1999~2000. Among reported cases, the number of boys was 31(50.8%), and 75.4% of subjects were from 2 months to 24 months old. 78.4% of adverse events occurred within one week after immunization. Conclusion : We can find that surveillance system of AEFI and quality of epidemiologic investigation has been somewhat improved. But, it seems that severe cases were more frequently reported than moderate or mild cases, and reporting rate was lower than that of other developed countries. We could not identify the detailed epidemiologic characteristics of AEFI due to these limitation of data. To achieve the stabilization of National Immunization Program, reporting rate and the quality of investigation should be improved.

  • PDF

A Comprehensive Computer Program for Monitor Unit Calculation and Beam Data Management: Independent Verification of Radiation Treatment Planning Systems (방사선치료계획시스템의 독립적 검증을 위한 선량 계산 및 빔데이터 관리 프로그램)

  • Kim, Hee-Jung;Park, Yang-Kyun;Park, Jong-Min;Choi, Chang-Heon;Kim, Jung-In;Lee, Sang-Won;Oh, Heon-Jin;Lim, Chun-Il;Kim, Il-Han;Ye, Sung-Joon
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.231-240
    • /
    • 2008
  • We developed a user-friendly program to independently verify monitor units (MUs) calculated by radiation treatment planning systems (RTPS), as well as to manage beam database in clinic. The off-axis factor, beam hardening effect, inhomogeneity correction, and the different depth correction were incorporated into the program algorithm to improve the accuracy in calculated MUs. A beam database in the program was supposed to use measured data from routine quality assurance (QA) processes for timely update. To enhance user's convenience, a graphic user interface (GUI) was developed by using Visual Basic for Application. In order to evaluate the accuracy of the program for various treatment conditions, the MU comparisons were made for 213 cases of phantom and for 108 cases of 17 patients treated by 3D conformal radiation therapy. The MUs calculated by the program and calculated by the RTPS showed a fair agreement within ${\pm}3%$ for the phantom and ${\pm}5%$ for the patient, except for the cases of extreme inhomogeneity. By using Visual Basic for Application and Microsoft Excel worksheet interface, the program can automatically generate beam data book for clinical reference and the comparison template for the beam data management. The program developed in this study can be used to verify the accuracy of RTPS for various treatment conditions and thus can be used as a tool of routine RTPS QA, as well as independent MU checks. In addition, its beam database management interface can update beam data periodically and thus can be used to monitor multiple beam databases efficiently.

  • PDF

Standardization of Identification-number for Processed Food in Food-traceability-system (가공식품에 대한 이력추적관리번호 부여체계의 표준화 방안)

  • Choi, Joon-Ho
    • Journal of Food Hygiene and Safety
    • /
    • v.27 no.2
    • /
    • pp.194-201
    • /
    • 2012
  • Facing a number of global food-related accidents, the concept and system for food traceability have been designed and introduced in many countries to manage the food-safety risks. To connect and harmonize the various food traceability-information in food traceability system according to the food supply chain, the coding system of identification-number for food-traceability has to be standardized. The GTIN (Global Trade Item Number) barcode system which has been globally standardized and implemented, is reviewed with the mandatory food-labeling regulation in expiration date of processed foods. The integration of GTIN-13 bar-code system for food-traceability is a crucial factor to expand its function in the food-related industrial areas. In this literature, the standard coding system of identification-number for food-traceability is proposed with 20 digit coding number which is combined with GTIN-13 bar-code (13 digit), expiration date (6 digit), and additional classification code (1 digit). This proposed standard coding system for identification-number has a several advantages in application for prohibiting the sale of hazard goods, food-recall, and inquiring food traceability-information. And also, this proposed coding system could enhance the food traceability system by communicating and harmonizing the information with the national network such as UNI-PASS and electronic Tax-invoice system. For the global application, the identification-number for food-traceability needs to be cooperated with the upcoming global standards such as GTIN-128 bar-code and GS1 DataBar.

Novel LTE based Channel Estimation Scheme for V2V Environment (LTE 기반 V2V 환경에서 새로운 채널 추정 기법)

  • Chu, Myeonghun;Moon, Sangmi;Kwon, Soonho;Lee, Jihye;Bae, Sara;Kim, Hanjong;Kim, Cheolsung;Kim, Daejin;Hwang, Intae
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.3
    • /
    • pp.3-9
    • /
    • 2017
  • Recently, in 3rd Generation Partnership Project(3GPP), there is a study of the Long Term Evolution(LTE) based vehicle communication which has been actively conducted to provide a transport efficiency, telematics and infortainment. Because the vehicle communication is closely related to the safety, it requires a reliable communication. Because vehicle speed is very fast, unlike the movement of the user, radio channel is rapidly changed and generate a number of problems such as transmission quality degradation. Therefore, we have to continuously updates the channel estimates. There are five types of conventional channel estimation scheme. Least Square(LS) is obtained by pilot symbol which is known to transmitter and receiver. Decision Directed Channel Estimation(DDCE) scheme uses the data signal for channel estimation. Constructed Data Pilot(CDP) scheme uses the correlation characteristic between adjacent two data symbols. Spectral Temporal Averaging(STA) scheme uses the frequency-time domain average of the channel. Smoothing scheme reduces the peak error value of data decision. In this paper, we propose the novel channel estimation scheme in LTE based Vehicle-to-Vehicle(V2V) environment. In our Hybrid Reliable Channel Estimation(HRCE) scheme, DDCE and Smoothing schemes are combined and finally the Linear Minimum Mean Square Error(LMMSE) scheme is applied to minimize the channel estimation error. Therefore it is possible to detect the reliable data. In simulation results, overall performance can be improved in terms of Normalized Mean Square Error(NMSE) and Bit Error Rate(BER).

Comparison of Clinical Results of Excimer Laser Correction of Myopia and Compound Myopic Astigmatism Using VISX 20/20B $VisionKey^{TM}$ (VISX 20/20B $VisionKey^{TM}$ 엑시머레이저의 version 4.01 software를 이용한 근시교정술 및 근시성난시교정술의 임상성적 비교)

  • Lee, Sang-Bumm;Bae, Sang-Bok
    • Journal of Yeungnam Medical Science
    • /
    • v.17 no.1
    • /
    • pp.55-65
    • /
    • 2000
  • Purpose: To compare the efficacy, predictability, stability and safety of excimer laser photorefracive keratectomy(PRK) for myopia and photoastigmatic refractive keratectomy(PARK) for compound myopic astigmatism. Methods: Two-hundred and three eyes(l18 eyes < -7D spherical equivalent, 85 eyes ${\geq}$ -7D spherical equivalent) received excimer laser correction for compound myopic astigmatism and 152 eyes(116 eyes < -7D, 36 eyes ${\geq}$ -7D) for simple myopia. A VISX 20/20B $VisionKey^{TM}$ excimer laser was used to perform either PARK or PRK. Visual acuity with and without correction, refraction, IOP, corneal haze, and topography were evaluated at 1, 3, 6, and 12 months postoperatively. All patients were followed up for more than 12 months. Results: Postoperative refraction were generally stable after 3 months without significant early overcorrection. At 12 months, 110(94.8%) eyes that underwent PRK and 104(88.1%) eyes that underwent PARK achieved UCVA of 20/30 or better in the group who had lower than -7D correction. For eyes treated with -7D or more, these figures were 31(86.1%) eyes after PRK and 57(67.1%) eyes after PARK. The incidences of within 1D of plano refraction at 1 year follow-up were 97.4% after PRK and 93.2% after PARK in the group who had lower than -7D correction. For eyes treated with -7D or more, these figures were 80.6% after PRK and 70.6% after PARK. Conclusions Myopia with or without astigmatism was successfully treated in most of the eyes using PRK or PARK with VISX 20/20B $VisionKey^{TM}$ excimer laser. The predictability and stability of the postoperative refraction during the first 12 months seem to be quite reliable. Further improvement of excimer laser system and software should increase the clinical outcomes and safety of refractive procedures.

  • PDF

Development of Adaptive Spatial Filter to Improve Noise Characteristics of PET Images (PET 영상의 잡음개선을 위한 적응적 공간 필터 개발)

  • Woo, S. K.;Choi, Y.;Im, K. C.;Song, T. Y.;Jung, J. H.;Lee, K. H.;Kim, S. E.;Choe, Y. S.;Park, C. C.;Kim, B. T.
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.3
    • /
    • pp.253-261
    • /
    • 2002
  • A spatially adaptive falter was formulated to imrove PET image qualify and the Performance of the filter was evaluated using simulation and phantom and human PET studies. In the proposed filter. if a pixel was identified as the edge Pixel, the Pixel value was Preserved. Otherwise a Pixel was replaced by the mean of the pixel values weighted by 2:7: 2. A Pixel was identified as the edge Pixel. if it satisfies the following conditions : the number of ADs (absolute difference between center and neighborhood pixels) which is smaller than THl (($pix_max{\times}0.1/log_2(NPM)$, NPM : mean of 6 neighborhood pixels excluding minimum and maximum) is 8-k and the number of ADs which is lager than TH2 ($NPM{\times}0.1$) is k. where k : 2, 3, …, 6. The results of this study demonstrate the superior performance of the Proposed titter compared to Gaussian fitter, weight median filter and subset averaged median filter. The proposed tittering method is simple but effective in increasing uniformity and contrast with minimal degradation of spatial resolution of PET images and thus. is expected to Provide improved diagnositc quality PET images .

Enhancement of Immune Activities of Peptides from Asterias amurensis Using a Nano-encapsulation Process (나노 입자 불가사리 펩타이드의 면역 활성 증진)

  • Jeong, Hyang-Suk;Oh, Sung-Ho;Kim, Seoung-Seop;Jeong, Myoung-Hoon;Choi, Woon-Yong;Seo, Yong-Chang;Choi, Geun-Pyo;Kim, Jin-Chul;Lee, Hyeon-Yong
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.4
    • /
    • pp.424-430
    • /
    • 2010
  • Immuno-modulatory activities of peptides from Asterias amurensis were investigated using a nano-encapsulation process. The molecular weights of the peptides in the range of 5-7 kDa were separated using Sephadex G-75 gel filtration. Eighty-five percent of the nano-particles were in the 300 nm range using dynamic light scattering. The cytotoxicity of the A. amurensis nano-particles against CCD-986sk human dermal fibroblast cells was 11.64% after adding 1.0 mg/mL of the samples, which was lower than that from the control (13.28% collagen). The secretion of $NO^-$ from macrophages was estimated as $40\;{\mu}M$ after adding 1.0 mg/mL of gelatin nano-particles, which was higher than the others. Prostaglandin $E_2$ production from UV-induced human skin cells decreased greatly to 860 pg/mL after adding 1.0 mg/mL of the samples. Confocal microscopy revealed that nano-particles effectively penetrated the cells within 1 hour. From these results, we consider that nano-encapsulation of the peptides from A. amurensis can improve their biological functions.

Development of a Dose Calibration Program for Various Dosimetry Protocols in High Energy Photon Beams (고 에너지 광자선의 표준측정법에 대한 선량 교정 프로그램 개발)

  • Shin Dong Oh;Park Sung Yong;Ji Young Hoon;Lee Chang Geon;Suh Tae Suk;Kwon Soo IL;Ahn Hee Kyung;Kang Jin Oh;Hong Seong Eon
    • Radiation Oncology Journal
    • /
    • v.20 no.4
    • /
    • pp.381-390
    • /
    • 2002
  • Purpose : To develop a dose calibration program for the IAEA TRS-277 and AAPM TG-21, based on the air kerma calibration factor (or the cavity-gas calibration factor), as well as for the IAEA TRS-398 and the AAPM TG-51, based on the absorbed dose to water calibration factor, so as to avoid the unwanted error associated with these calculation procedures. Materials and Methods : Currently, the most widely used dosimetry Protocols of high energy photon beams are the air kerma calibration factor based on the IAEA TRS-277 and the AAPM TG-21. However, this has somewhat complex formalism and limitations for the improvement of the accuracy due to uncertainties of the physical quantities. Recently, the IAEA and the AAPM published the absorbed dose to water calibration factor based, on the IAEA TRS-398 and the AAPM TG-51. The formalism and physical parameters were strictly applied to these four dose calibration programs. The tables and graphs of physical data and the information for ion chambers were numericalized for their incorporation into a database. These programs were developed user to be friendly, with the Visual $C^{++}$ language for their ease of use in a Windows environment according to the recommendation of each protocols. Results : The dose calibration programs for the high energy photon beams, developed for the four protocols, allow the input of informations about a dosimetry system, the characteristics of the beam quality, the measurement conditions and dosimetry results, to enable the minimization of any inter-user variations and errors, during the calculation procedure. Also, it was possible to compare the absorbed dose to water data of the four different protocols at a single reference points. Conclusion : Since this program expressed information in numerical and data-based forms for the physical parameter tables, graphs and of the ion chambers, the error associated with the procedures and different user could be solved. It was possible to analyze and compare the major difference for each dosimetry protocol, since the program was designed to be user friendly and to accurately calculate the correction factors and absorbed dose. It is expected that accurate dose calculations in high energy photon beams can be made by the users for selecting and performing the appropriate dosimetry protocol.

Semi-supervised learning for sentiment analysis in mass social media (대용량 소셜 미디어 감성분석을 위한 반감독 학습 기법)

  • Hong, Sola;Chung, Yeounoh;Lee, Jee-Hyong
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.24 no.5
    • /
    • pp.482-488
    • /
    • 2014
  • This paper aims to analyze user's emotion automatically by analyzing Twitter, a representative social network service (SNS). In order to create sentiment analysis models by using machine learning techniques, sentiment labels that represent positive/negative emotions are required. However it is very expensive to obtain sentiment labels of tweets. So, in this paper, we propose a sentiment analysis model by using self-training technique in order to utilize "data without sentiment labels" as well as "data with sentiment labels". Self-training technique is that labels of "data without sentiment labels" is determined by utilizing "data with sentiment labels", and then updates models using together with "data with sentiment labels" and newly labeled data. This technique improves the sentiment analysis performance gradually. However, it has a problem that misclassifications of unlabeled data in an early stage affect the model updating through the whole learning process because labels of unlabeled data never changes once those are determined. Thus, labels of "data without sentiment labels" needs to be carefully determined. In this paper, in order to get high performance using self-training technique, we propose 3 policies for updating "data with sentiment labels" and conduct a comparative analysis. The first policy is to select data of which confidence is higher than a given threshold among newly labeled data. The second policy is to choose the same number of the positive and negative data in the newly labeled data in order to avoid the imbalanced class learning problem. The third policy is to choose newly labeled data less than a given maximum number in order to avoid the updates of large amount of data at a time for gradual model updates. Experiments are conducted using Stanford data set and the data set is classified into positive and negative. As a result, the learned model has a high performance than the learned models by using "data with sentiment labels" only and the self-training with a regular model update policy.