• Title/Summary/Keyword: 모의실험장치

Search Result 380, Processing Time 0.025 seconds

A STUDY ON PROFILE CHANGE OF SKELETAL CLASS III MALOCCLUSION PATIENTS AFTER WEARING PROTRACTION HEAD GEAR (골격성 제III급 부정교합 환자에서 상악골 전방견인장치 사용후 측모 변화에 대한 연구)

  • Lim, Joong-Ki;Park, Young-Chel
    • The korean journal of orthodontics
    • /
    • v.25 no.4
    • /
    • pp.375-401
    • /
    • 1995
  • Cause of skeletal Class III malocclusion in growing patients can be classified into maxillary deficiency, mandibular overgrowth, and combination of the two. Use of Protraction Head Gear(P.H.G.) has been recommended for treatment of growing Class III malocclusion patients, for it results in forward & downward movement of maxilla and backward & downward rotation of mandible. Numerous animal experiments were performed and clinical study data have been reported ; nevertheless, studies on soft tissue profile change and comparison of treatment effects among the patients who had undergone treatment are considered to be somewhat insufficient. The author selected 93 patients, who had been diagnosed as skeletal Class III malocclusion with maxillary deficiency and then treated with P.H.G. ; the sample group was divided according to sex, treatment beginning age, palatal suture opening(intraoral appliance), and facial growth pattern. For each group, changing patterns of hard and soft tissue profile observed, and comparision with 20 normal group(Angle's Class I) patients of statistical significance in amount of growth and treatment of hard and soft tissue was done. The following results were obtained. 1. Skeletal, dental, and soft tissue measurements indicated that more growth changes was induced in the sample group that used P.H.G. compared to the growth amount of normal group. 2. No statistical significance was observed in the amounts of maxillary forward movement and mandibular backward & downward rotation depending on treatment beginning age in both sex group. 3. R.P.E. showed more significant maxillary forward movement and less protrusion of upper incisor than La-Li. 4. There was no statistical significance in the amount of maxillary forward movement depending on facial growth pattern. On the other hand, measurements indicating mandibular downward & backward rotation indicated greater change in counterclockwise growth pattern group than the clockwise. 5. Changes in upper and lower lip thicknesses showed a close relationship with positional changes in underlying bone tissue and upper and lower teeth, and upper lip height and nasolabial angle increased and mentolabial angle decreased.

  • PDF

Analysis of Dose Delivery Error in Conformal Arc Therapy Depending on Target Positions and Arc Trajectories (동적조형회전조사 시 표적종양의 위치변위와 조사반경의 변화에 따른 선량전달 오류분석)

  • Kang, Min-Young;Lee, Bo-Ram;Kim, You-Hyun;Lee, Jeong-Woo
    • Journal of radiological science and technology
    • /
    • v.34 no.1
    • /
    • pp.51-58
    • /
    • 2011
  • The aim of the study is to analyze the dose delivery error depending on the depth variation according to target positions and arc trajectories by comparing the simulated treatment planning with the actual dose delivery in conformal arc therapy. We simulated the conformal arc treatment planning with the three target positions (center, 2.5 cm, and 5 cm in the phantom). For the experiments, IMRT body phantom (I’mRT Phantom, Wellhofer Dosimetry, Germany) was used for treatment planning with CT (Computed Tomography, Light speed 16, GE, USA). The simulated treatment plans were established by three different target positions using treatment planning system (Eclipse, ver. 6.5, VMS, Palo Alto, USA). The radiochromic film (Gafchromic EBT2, ISP, Wayne, USA) and dose analysis software (OmniPro-IMRT, ver. 1.4, Wellhofer Dosimetry, Germany) were used for the measurement of the planned arc delivery using 6 MV photon beam from linear accelerator (CL21EX, VMS, Palo Alto, USA). Gamma index (DD: 3%, DTA: 2 mm) histogram and dose profile were evaluated for a quantitative analysis. The dose distributions surrounded by targets were also compared with each plans and measurements by conformity index (CI), and homogeneity index (HI). The area covered by 100% isodose line was compared to the whole target area. The results for the 5 cm-shifted target plan show that 23.8%, 35.6%, and 37% for multiple conformal arc therapy (MCAT), single conformal arc therapy (SCAT), and multiple static beam therapy, respectively. In the 2.5 cm-shifted target plan, it was shown that 61%, 21.5%, and 14.2%, while in case of center-located target, 70.5%, 14.1%, and 36.3% for MCAT, SCAT, and multiple static beam therapy, respectively. The values were resulted by most superior in the MCAT, except the case of the 5 cm-shifted target. In the analysis of gamma index histogram, it was resulted of 37.1, 27.3, 29.2 in the SCAT, while 9.2, 8.4, 10.3 in the MCAT, for the target positions of center, shifted 2.5 cm and 5 cm, respectively. The fail proportions of the SCAT were 2.8 to 4 times as compared to those of the MCAT. In conclusion, dose delivery error could be occurred depending on the target positions and arc trajectories. Hence, if the target were located in the biased position, the accurate dose delivery could be performed through the optimization of depth according to arc trajectory.

A Disk Group Commit Protocol for Main-Memory Database Systems (주기억 장치 데이타베이스 시스템을 위한 디스크 그룹 완료 프로토콜)

  • 이인선;염헌영
    • Journal of KIISE:Databases
    • /
    • v.31 no.5
    • /
    • pp.516-526
    • /
    • 2004
  • Main-Memory DataBase(MMDB) system where all the data reside on the main memory shows tremendous performance boost since it does not need any disk access during the transaction processing. Since MMDB still needs disk logging for transaction commit, it has become another bottleneck for the transaction throughput and the commit protocol should be examined carefully. There have been several attempts to reduce the logging overhead. The pre-commit and group commit are two well known techniques which do not require additional hardware. However, there has not been any research to analyze their effect on MMDB system. In this paper, we identify the possibility of deadlock resulting from the group commit and propose the disk group commit protocol which can be readily deployed. Using extensive simulation, we have shown that the group commit is effective on improving the MMDB transaction performance and the proposed disk group commit almost always outperform carefully tuned group commit. Also, we note that the pre-commit does not have any effect when used alone but shows some improvement if used in conjunction with the group commit.

Adaptive Decision Feedback Equalizer using the hierarchical Feedback filter and Soft decision device (계층적 궤환 필터 구조와 연판정 장치를 갖는 적응형 결정 궤환 등화기)

  • Lim, Dong-Guk;Song, Jeong-Ig;Kim, Jae-Mong
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.1
    • /
    • pp.138-145
    • /
    • 2007
  • Wireless transmission system using the multipath channel is affected ISI due to the delay spread. So we use a decision feedback equalizer which consist of decision part and feedback filter for remove the ISI effectively. In this paper, we propose a improved adaptive decision feedback equalizer to mitigate ISI effectively. The proposed adaptive decision feedback equalizer is construct by using soft decision device and hierarchical feedback filter based on MMSE sub-optimal equalizer using the LMS algorithm. Soft decision device mitigate the error propagation in feedback filter by incorrectly detected decision symbol and feedback filter which is divided two step independently mitigate the ISI by using a adaptive algorithm. As a result this structure shows better performance than conventional decision feedback equalizer by mitigating the error propagation in filter cause incorrectly detecting symbol. and we get the MSE more rapidly by using larger step-size due to reduce the number of feedback filter tap. In computer simulation, we compare the bit error rate performance of proposed decision feedback equalizer with conventional one on the S-V channel model for UWB system.

Synthesis of Low Concentration of NaOH Solution using $Na^+$ ion in the Concentrated Water from Membrane Separation Process (분리막 농축수에 포함된 Na를 이용한 저농도 NaOH 용액의 합성)

  • Lee, Yoon-Ji;Park, Youn-Jin;Choi, Jeong-Hak;Shin, Won-Sik;Choi, Sang-June;Chon, Uong
    • Korean Chemical Engineering Research
    • /
    • v.49 no.6
    • /
    • pp.810-815
    • /
    • 2011
  • Concentrated water discharged from seawater desalination process contains a high concentration of $Na^+$ ion. Electrolysis was applied to synthesize NaOH solution from the highly concentrated NaCl solution. The effect of various operating parameters of composited laboratory-scale chlor-alkali (CA) membrane cell was investigated. The operating parameters such as membrane types (CIMS and Nafion membranes), pretreatment of the membrane, flow rate (73 mL/min~200 mL/min), initial $Na^+$ ion concentration (1.5 M, 3M and 5 M) and current (1.5A and 2A) were evaluated. It was observed that synthesis efficiency of NaOH solution with CIMS membrane was higher than that with Nafion membrane, but the durability of CIMS membrane on $Cl_2$ gas was poor. The synthesis efficiency of NaOH solution increased with increasing initial $Na^+$ ion concentration and current, while the efficiency decreased with increasing flow rate using Nafion membrane.

Effects of activator treatment on different skeletal patterns in growing class II malocclusion patients (성장기 II급 부정교합자에서 골격 형태에 따른 액티베이터 사용 효과에 관한 연구)

  • Ki, Jun-Hun;Lee, Jin-Woo
    • The korean journal of orthodontics
    • /
    • v.37 no.1 s.120
    • /
    • pp.29-43
    • /
    • 2007
  • Objective: To establish proper diagnosis and treatment plan for skeletal Class II malocclusions, some important factors to consider are the patient's skeletal morphology, prognosis as well as the treatment effects. Therefore, the present study analyzed the effects of activator treatment on different skeletal patterns in growing Class II malocclusion patients. Methods: A total of 116 patients (53 boys & 63 girls) in the experimental group were treated with the activator appliance. The experimental group was classified into either hyperdivergent or hypodivergent groups according to articular and genial angles. Results: Patients with hypodivergent growth patterns showed good effects of activator treatment. Conclusion: It seems conceivable that through classifying adolescent Class II malocclusion patients into different skeletal patterns, activator treatment effects may be predicted during the diagnosis and treatment planning stage.

Enhanced VLC-TDoA Algorithm for Indoor Positioning Without LED-ID (LED-ID 없이 실내 위치 추정이 가능한 개선된 VLC-TDoA 알고리즘)

  • Do, Trong-Hop;Hwang, Junho;Yoo, Myungsik
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38B no.8
    • /
    • pp.672-678
    • /
    • 2013
  • In the recent year, along with the rapid development of LED technology, many applications using LEDs have been researched and indoor positioning is one of them. In particular, previous indoor positioning systems based on visible light communication combine triangulation manner such as AoA, ToA TDoA. But most of them needs transmitting unique ID of each LED panel. In this paper, we propose an non LED-ID based indoor positioning system in which the visible light radiated from LEDs is used to locate the position of receiver. Compared to current indoor positioning systems using LED light, our system has the advantages of simple implementation, low cost and high accuracy. Through the computer simulation, our system can achieve a high estimation accuracy of 3.6cm in average in the $5{\times}5{\times}3m^3$ room.

A Location-based Highway Safety System using Smart Mobile Devices (스마트 모바일 장치를 이용한 위치기반 고속도로 안전시스템)

  • Lee, Jaehyun;Park, Sungjin;Yoo, Joon
    • Journal of KIISE
    • /
    • v.43 no.3
    • /
    • pp.389-397
    • /
    • 2016
  • In this paper, we propose a highway safety system that comprises a small number of central servers and smart mobile devices. To implement this system, we constructed a central server that collects GPS location information on cars, whose update messages are decreased via the car location estimation algorithm. The in-car mobile devices use the accelerometer sensors to detect hazardous situations; this information is updated to the central server that relays the information to the corresponding endangered cars via location-based unicast using LTE communication. To evaluate the proposed algorithm, we equipped a mobile device app on a real car and conducted real experiments in various environments such as city streets, rural areas, and highway roads. Furthermore, we conducted simulations to evaluate the propagation of danger information. Finally, we conducted simulated experiments to detect car collisions as well as exceptions, such as falling of the mobile device from the cradle.

A monopulse radar uncertainty study classified on target property (표적 특성에 따른 모노펄스 레이더 불확도 연구)

  • Jang, Yong-sik;Ryu, Chung-ho;Kim, Whan-woo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.1
    • /
    • pp.229-236
    • /
    • 2017
  • In general, an error budget of monopulse radar is proposed by manufacturer who assuming that all of external enviromental error resources such as multipath, glint, dynamic lag variation are removed. So until now, a measurement uncertainty of monopulse radar can be discussed including external enviromental error resources. In this paper, it is described that which kinds of error resource can effect on monopulse radar measurement uncertainty for different target property. To prove it experimentally, at first a simulation result is described assuming that all of external enviromental error resources are removed. It only includes receiver thermal noise. And then, monopulse radar measurement uncertainty estimation results tracking on calibration target which is fixed on specific position, calibration sphere which is moving slowly, weapon systems firing test which is moving fast are described quantitativly. All of these targets have different dynamic property.

Leakage Localization with an Acoustic Array that Covers a Wide Area for Pipeline Leakage Monitoring in a Closed Space (닫힌 공간에서의 광역배관 누출 감시를 위한 배열센서를 이용한 누설 위치 검출)

  • Park, Choon-Su;Jeon, Jong-Hoon;Park, Jin-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.5
    • /
    • pp.422-429
    • /
    • 2013
  • It is of great importance to localize leakages in complex pipelines for assuring their safety. A sensor array that can detect where leakages occur enables us to monitor a wide area with a relatively low cost. Beamforming is a fast and efficient algorithm to estimate where sources are, but it is generally made use of in free field condition. In practice, however, many pipelines are placed in a closed space for the purpose of safety and maintenance. This leads us to take reflected waves into account to the beamforming for interior leakage localization. Beam power distribution of reflected waves in a closed space is formulated, and spatial average is introduced to suppress the effect of reflected waves. Computer simulations and experiments ensure how the proposed method is effective to localize leakage in a closed space for structural health monitoring.