• 제목/요약/키워드: 모멘트 골조

검색결과 271건 처리시간 0.027초

토글 가새-고집적 마찰댐퍼를 설치한 철근콘크리트 모멘트 골조의 성능 평가 (Seismic Behavior of Reinforced Concrete Moment Frames Retrofitted by Toggle Bracing System with High Density Friction Damper)

  • 한상환;김지영;문기훈;이창석;김형준;이강석
    • 한국지진공학회논문집
    • /
    • 제18권3호
    • /
    • pp.133-140
    • /
    • 2014
  • The friction damper can be used for improving the seismic resistance of existing buildings. The damper is often installed in bracing members. The energy dissipation capacity of the damping systems depends on the type of the structure, the configuration of the bracing members, and the property of dampers. In Korea, there are numerous low- to mid-rise reinforced concrete moment frames that were constructed considering only gravity loads. Those frames may be vulnerable for future earthquakes. To resolve the problem, this study developed a toggle bracing system with a high density friction damper. To investigate the improvement of reinforced concrete frames after retrofit using the developed damped system, experimental tests were conducted on frame specimens with and without the damped system. The results showed that the maximum strength, initial stiffness and energy dissipation capacity of the framed with the damped system were much larger than those of the frame without the damped system.

다자유도 철근 콘크리트 모멘트 골조의 Steel Jacket보강 내진성능개선 (Seismic Performance Improvement of MDOF Reinforced Concrete Moment Frame Retrofitted Steel Jacket)

  • 김준영;정인규;박순응
    • 한국공간구조학회논문집
    • /
    • 제13권1호
    • /
    • pp.69-77
    • /
    • 2013
  • This study is the research appling the representative Displacement-Based Design which is the basic concept of Direct Displacement Based Design proposed by Chopra and Goel to original Reinforced Concrete moment frame and determining the thickness of retrofit Steel Jacket about the Maximum design ground acceleration, and developing the more improved Algorithm as well as program by the Retrofit Design method and Nonlinear analysis by the Performance design method before and after reinforcement appling the determined retrofit thickness. It also shows the result of the seismic performance improvement which is the ratio of seismic performance appreciation result yield displacement 19%, yield strength ratio 24%, displace ductility ratio the maximum 27% comparing Multi degree of freedom, column member of Reinforced Concrete with the performance improvement column member considering the thickness of the determined Steel Jacket. The developed Algorithm and program are easy to apply seismic design and application to the original Reinforced Concrete building, at the same time, it applicate to display well the design result of Target displacement performance level about nonlinear behavior.

철골 구조물의 제진 및 면진성능 (Damping and Isolation Performance of Steel Structure)

  • 윤현도;박완신;한병찬;황선경;이규
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제8권2호
    • /
    • pp.221-230
    • /
    • 2004
  • 본 논문에서는 지진하중 작용시, 점탄성 감쇠기 및 면진장치를 설치한 다층 철골 모멘트 저항 골조의 동적응답을 해석적으로 규명하였다. 본 연구의 목적은 구조해석을 수행하여 최대 층간변위 및 최대응력법에 의해 효율적인 점탄성 감쇠기의 위치를 결정하는 것이다. 또한, 효율적인 진동 제어방법을 모색하기 위하여 점탄성 감쇠기 및 납삽입고무베어링형 면진장치에 의한 제어효과를 부재력, 조합응력, 그리고 구조물의 고유주기 등을 이용하여 상호 비교 분석하였다.

소규모 철근콘크리트 모멘트골조 건축물의 초과강도, 연성도 및 반응수정계수 (Over-Strength, Ductility and Response Modification Factor of Small-Size Reinforced Concrete Moment Frame Buildings)

  • 김태완;추유림;박홍근;신영수
    • 한국지진공학회논문집
    • /
    • 제20권3호
    • /
    • pp.145-153
    • /
    • 2016
  • Small-size buildings are not designed by professional structural engineers in Korea. Therefore, their seismic performance can not be exactly estimated because their member sizes and reinforcement may be over- or under-designed. A prescriptive design criteria for the small-size buildings exists, but it also provides over-designed structural members since structural analysis is not incorporated, so it is necessary to revise the prescriptive criteria. The goal of this study was to provide an information for the revision, which is seismic performance and capability of small-size reinforced concrete moment frame buildings. For the study, the state of existing small-size reinforce-concrete buildings such as member size and reinforcement was identified by investigating their structural drawings. Then, over-strength, ductility and response modification factor of the small-size reinforced concrete moment frame buildings were estimated by analytical approach along with seismic performance check. The result showed that they possess moderate over-strength and ductility, and may use slightly increased response modification factor.

비좌굴가새의 보강 전과 후의 철골 특수모멘트저항골조 건물의 R계수 평가 (Evaluation of Response Modification Factor of Steel Special Resisting Frame Building Before and After Retrofitted with Buckling Restrained Brace)

  • 신지욱;이기학;조영욱
    • 한국지진공학회논문집
    • /
    • 제17권1호
    • /
    • pp.11-19
    • /
    • 2013
  • This research presents that seismic performance of steel moment resisting frame building designed by past provision(UBC, Uniform Building Code) before and after retrofitted with BRB (Buckling-Restrained Brace) was evaluated using response modification factor (R-factor). In addition, the seismic performance of the retrofitted past building was compared with that specified in current provision. The past building considered two different connections: bilinear connection, which was used by structural engineer for building design, and brittle connection observed in past earthquakes. The nonlinear pushover analysis and time history analysis were performed for the analytical models considered in this study. The R-factor was calculated based on the analytical results. When comparing the R-factor of the current provision with the calculated R-factor, the results were different due to the hysteresis characteristics of the connection types. After retrofitted with BRBs, the past buildings with the bilinear connection were satisfied with the seismic performance of the current provision. However, the past buildings with the brittle connection was significantly different with the R-factor of the current provision.

내진 보강된 철골모멘트골조의 취약성 등고선을 통한 성능평가 (Performance Evaluation of Steel Moment Resisting Frames with Seismic Retrofit Using Fragility Contour Method)

  • 김수동;이기학;정성훈;김도현
    • 한국지진공학회논문집
    • /
    • 제17권1호
    • /
    • pp.33-41
    • /
    • 2013
  • Due to a high level of system ductility, steel moment resisting frames have been widely used for lateral force resisting structural systems in high seismic zones. Earthquake field investigations after Northridge earthquake in 1994 and Kobe earthquake in 1995 have reported that many steel moment resisting frames designed before 1990's had suffered significant damages and structural collapse. In this research, seismic performance assessment of steel moment resisting frames designed in accordance with the previous seismic provisions before 1990's was performed. Buckling-restrained braces and shear walls are considered for seismic retrofit of the reference buildings. Increasing stiffness and strength of the buildings using buckling-restrained braces and shear walls are considered as options to rehabilitate the damaged buildings. Probabilistic seismic performance assessment using fragility analysis results is used for the criteria for determining an appropriate seismic retrofit strategy. The fragility contour method can be used to provide an intial guideline to structural engineers when various structural retrofit options for the damaged buildings are available.

벽식구조 공동주택의 바닥충격음 개선에 대한 연구 (A Study on the Improvement of the Floor Impact Sound Insulation Performance in Wall Slab Type Apartment)

  • 김선우
    • KIEAE Journal
    • /
    • 제12권1호
    • /
    • pp.73-81
    • /
    • 2012
  • Floor impact sound has been most annoying for years among the noises which are produced in apartment. This study aims to analyze the improvement of floor impact sound by comparing the results of the test which was carried out for the wall slab type apartment and moment frame apartment, and also for the effect of advanced vibration isolation layer. Moment frame structure that main structure consists of column and slab has shown better performance for the heavyweight impact sound comparing with wall slab type structure which is general type in Korea. Stiffness of floor system was raised by reinforcing the stiffness of vibration isolation layer, and it was analyzed how much the floor impact sound performance was improved. The result showed that the reinforced floor had better performance than the existing floor system that uses lightweight porous concrete as vibration isolation material. In addition, a system used wire mesh in mortar showed improvement of floor impact sound than a system without wire mesh, and better performance for the frequency bands lower than 160 Hz which causes floor impact problem in wall slab type apartment.

반복하중을 받는 강재 브레이싱의 거동에 관한 해석적 연구 (A Study on the Analysis of Steel Bracing Behaviour Subjected to Cyclic Loads)

  • 구민세;김병석;김일곤
    • 전산구조공학
    • /
    • 제2권3호
    • /
    • pp.69-75
    • /
    • 1989
  • 브레이싱재를 사용하는 목적은 본 골조체계 즉 기둥과 보에 비해 단면(강성)이 작은 부재로 보강하여 횡력에 대한 강성효과를 크게 향상시키기 위함이다. 브레이싱재의 단면이 기둥과 보의 단면에 비해 월등히 작기 때문에 압축력에 의한 좌굴의 위험성과 휨량의 크기에 비례하여 부재 중앙에 발생되는 추가 모멘트(P-.DELTA. Effect)에 의한 불리한 영향 및 해석상의 어려움 때문에 브레이싱의 설계에 있어서 브레이싱재는 압축력을 받지 않는 것으로 간주하여 왔다. 그러나 최근 들어 구조물 해석에 정확도가 요구되어짐에 따라 브레이싱재의 정확한 거동에 대한 연구가 실험을 통해 활발히 진행되어 왔고, 특히 탄성한계를 지난 소성상태에서 반복하중에 의한 거동 규명이 큰 관심을 끌고 있다. 본 논문에서는 반복하중을 받는 강재 브레이싱재의 비선형 거동을 해석적 방법에 의해 규명했고, 그 결과를 실험결과와 비교하였다.

  • PDF

세장한 가새가 사용된 철골모멘트골조 공장시설물의 내진 성능평가 (Seismic Performance Evaluation of Steel Moment Frame Factory Building with Slender Braces)

  • 김동연;조재철;황선우;김태진;김종호
    • 한국지진공학회논문집
    • /
    • 제22권1호
    • /
    • pp.33-43
    • /
    • 2018
  • 'Seismic Performance Evaluation Method for Existing Buildings (2013)' developed in accordance with the overseas guidelines ASCE 41 - 06 is the most widely used procedure among domestic seismic performance evaluation guidelines in Korea. However, unlike ASCE 41 - 06, it stipulates that the final performance should be derived as the gravity load distribution ratio of the lateral force resistance system in the guideline. Therefore, in the case of a dual steel structure system with slender braces, where the internal moment frame is mostly responsible for the gravity load, the evaluation of slender braces based on gravity load distribution ratio is difficult to be achieved. In this research, we propose an objective evaluation process for such system by evaluating seismic performance for large-scale factory facilities as an example.

강판과 가새로 보강된 무량판 구조물의 내진 성능평가 (Seismic Performance Evaluation of Flat Plate Structures Retrofitted with Steel Plates and Braces)

  • 신우승;김진구
    • 한국전산구조공학회논문집
    • /
    • 제21권5호
    • /
    • pp.451-458
    • /
    • 2008
  • 본 논문에서는 중 약진 지역에서 중력 저항시스템인 중간 모멘트골조로 설계된 3층, 6층 RE 플랫플레이트 구조물을 KBC 2005를 만족하도록 RC구조물에 강판과 가새/ BRB 등의 보강방법을 적용하여 보강하고, 내진성능을 평가하여 보강 효과를 검증하였다. 비탄성 정적해석과 동적해석 결과에 따르면 내진 보강된 구조물은 강도와 강성이 크게 향상된 것으로 나타났다 특히 기둥을 철판으로 보강한 경우 슬래브를 철판으로 보강하여 조기 뚫림 전단파괴를 방지함으로써 강도를 크게 향상할 수 있다. BRB로 보강된 구조물은 Brace로 보강된 구조물보다 다소 연성적 거동을 보였으며, 그 효과는 3층 모델에서 현저하게 나타났다.