  • The use of grid paper in elementary mathematics textbooks is used in numbers and calculations, figures and measurement areas. Among them, it is used most in the figure area. In spite of this utilization, it is necessary to supplement it because it is difficult to revise or supplement the trial and error that often occurs in the course of the course, as the process of using the textbook paper in the actual class. The use of grid paper in elementary mathematics textbooks is used in numbers and calculations, figures and measurement areas. Among them, it is used most in the figure area. In spite of this utilization, it is necessary to supplement it because it is difficult to revise or supplement the trial and error that often occurs in the course of the course, as the process of using the textbook paper in the actual class. In this study, we tried to find out the usability of grid paper boards which can be used more effectively than the grid paper among the teaching aids presented in the 'Development of teaching aids standards for math class' of Korea Foundation for the Advancement of Science & Creativity(2017). A questionnaire survey was conducted on the use of grid paper and grid paper board for teachers who actually use grid paper in elementary mathematics. As a result, we found out the achievement criteria of grid paper board utilization and investigated the study subject which is effective to use grid paper board. In particular, we have identified specific learning topics that are effective in each area and presented specific activities.

Comparison of Center Error or X-ray Field and Light Field Size of Diagnostic Digital X-ray Unit according to the Hospital Grade (병원 등급에 따른 X선조사야와 광조사야 간의 면적 및 중심점 오차 비교)

  • Lee, Won-Jeong;Song, Gyu-Ri;Shin, Hyun-yi
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.245-252
    • /
    • 2020
  • The purpose of this study was intended to recognize the importance of quality control (QC) in order to reduce exposure and improve image quality by comparing the center-point (CP) of according to hospital grade and the difference between X-ray field (XF) and light field (LF) in diagnostic digital X-ray devices. XF and LF size, CP were measured in 12 digital X-ray devices at 10 hospitals located in 00 metropolitan cities. Phantom was made in different width respectively, using 0.8 mm wire after attaching to the standardized graph paper on transparent plastic plate and marked as cross wire in the center of the phantom. After placing the phantom on the table of the digital X-ray device, the images were obtained by shooting it vertically each field of survey. All images were acquired under the same conditions of exposure at distance of 100cm between the focus-detector. XF and LF size, CP error were measured using the picture archiving communication system. data were expressed as mean with standard error and then analyzed using SPSS ver. 22.0. The difference in field between the XF and LF size was the smallest in clinic, followed by university hospitals, hospitals and general hospitals. Based on the university hospitals with the least CP error, there was a statistically significant difference in CP error between university hospitals and clinics (p=0.024). Group less than 36-month after QC had fewer statistical errors than 36-month group (0.26 vs. 0.88, p=0.036). The difference between the XF and LF size was the lowest in clinic and CP error was the lowest in university hospital. Moreover, hospitals with short period of time after QC have fewer CP error and it means that introduction of timely QC according to the QC items is essential.