• Title/Summary/Keyword: 면 밀도

Search Result 924, Processing Time 0.032 seconds

Selective Discretized Marching Cube (선택적인 이산 마칭큐브)

  • 정지혜;김창헌
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2001.10b
    • /
    • pp.547-549
    • /
    • 2001
  • 본 논문에서는 MC의 알고리즘을 이용하여 등가면 추출시간을 단축할 수 있는 방법을 제안한다. 각 복셀 꼭지점의 밀도값을 비교하여 등가면이 형성될 수 있는 셀을 선택한다. 등가면이 형성되지 않는 빈 셀은 알고리즘을 진행하지 않고, 선택된 셀에 대해서만 등가면을 형성하기 위한 연산을 수행한다. 이때, 등가면 형성을 위한 꼭지점은 해당 모서리상에서 중앙점 보간으로 찾는다. 이러한 방법으로 형성된 등가면의 정보를 저장하는 객인 테이블을 효과적인 탐색이 가능하도록 개선함으로써 기존의 연구되다 빠르게 등가면을 추출하고 형성할 수 있다.

  • PDF

Optimal Planting Density on Growth and Quality Characteristics of Kohlrabi in a Closed-type Plant Factory System (완전제어형 식물공장에서 콜라비의 생육과 품질에 대한 적정 재식밀도)

  • Uoon, Chan-Il;Cho, Young-Yeol
    • Journal of Bio-Environment Control
    • /
    • v.28 no.2
    • /
    • pp.104-109
    • /
    • 2019
  • The crops recommended for the plant factory system are diverse. The importance of planting density in the plant factory is being recognized. The objective of this study was to determine the optimal planting density for growth and quality of kohlrabi in a closed-type plant factory system. The kohlrabi was grown under fluorescent lamps and nutrient film technique system. The growth and quality of kohlrabi were investigated under four different planting densities ($22plants/m^2(15{\times}30cm)$, $27plants/m^2(15{\times}25cm)$, and $33plants/m^2(15{\times}20cm)$). There were no significant interactions between Shoot fresh and dry weights per plant or bulb stem fresh and dry weights per plant and planting density. Shoot fresh and dry weight per area or bulb stem fresh and dry weight per area were the highest at $33plants/m^2$. There were no significant interactions between plant height, leaf area, photosynthetic rate, hardness, and chlorophyll content and planting density. Significant differences in Bulb stem height and diameter, and brix were observed. Bulb stem height and diameter and brix of kohlrabi were the highest at $22plants/m^2$. Based on our results, we conclude that the optimal planting density is $33plants/m^2$ for growth of kohlrabi, however, the optimal planting density is $22plants/m^2$ for quality of kohlrabi in a closed-type plant factory system.

Studies on the Improvement of Rice Cultivation in the Ill-drained Paddy Field III. The Effect of the Various Agronomic Characteristics on the Fertilization and Planting Density under Different Drainage Control Part. (습답도작기술향상에 관한 연구 III. 배수조건별 시비량 대 재식밀도가 수도실용제형성에 미치는 영향)

  • 노승표
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.23 no.2
    • /
    • pp.61-67
    • /
    • 1978
  • Drainage furnished air to provide favorable soil environment forfice growth at the late stage. A heavier fertilizer application and a denser plant density increase. Yield and yield component element by root activities and various substence productive element under sub-drainage.

  • PDF

Spatiotemporal Behavior of Excited Xenon Atom Density in Accordance with Xenon Mole Fraction to Neon and Helium in Alternating Current Plasma Display Panels by Laser Absorption Spectroscopy

  • Kim, Yong-Hee;Hong, Young-June;Oh, Phil-Yong;Cho, Guang-Sup;Choi, Eun-Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.415-415
    • /
    • 2010
  • 면방전 구조의 AC-PDP는 페닝 혼합 기체 중에서 Xe 플라스마에서 발생되는 VUV (Vacuum Ultra Violet) 에 의해 들뜬 형광체로부터 가시광이 발생된다. Xe 여기종은 828 nm의 공명준위를 거쳐 147 nm의 진공자외선을 방출하며 823 nm의 준안정준위에서 분자선을 거쳐 173 nm의 진공 자외선을 낸다. 이러한 Xe 여기종의 밀도를 측정하기 위해서는 828 nm와 823 nm의 레이저를 외부에서 인위적으로 조사하여 측정하면 IR (Infrared)의 흡수전과 흡수후의 빛의 세기로 Xe 여기종의 밀도 및 분포를 계산할 수 있다. 본 실험에서는 823 nm에 초점을 두었으며 LAS (Laser Absorption Spectroscopy) 기법을 통하여 He-Ne-Xe(15%, 20 %, 30%) 400Torr의 3종 기체의 Xe 함량에 따른 시공간의 Xe($1s_5$) 여기종 밀도 분포와 방전효율을 관측하였다. 최근 3전극 면방전형 AC-PDP 효율 향상을 위해 3종 기체의 Xe함량비의 방전기체에 대한 연구가 수행되고 있다. 이러한 기초 데이터는 혼합기체 조건에 따른 면방전 구조의 3전극 AC-PDP의 발광 효율을 개선하는 데 유용한 자료로 활용될 것이다.

  • PDF

Cultivation of Oyster Mushroom Using Non Sterilized Media (무살균 배지를 이용한 느타리버섯 재배)

  • Jang, Hyun-Yu;Kim, Hyuk
    • Korean Journal of Plant Resources
    • /
    • v.14 no.3
    • /
    • pp.196-205
    • /
    • 2001
  • The results of examining cultivation of tlyster mushroom using NSM(Non Sterilized Media) for determining the condition of artificially culturing oyster mushroom(Pleurotus ostreatus) are as follows. Mycelial growth an[1 density of oyster mushroom. were the highest in the medium of waste cotton(spinning) : corn cob(80 : 20, V/V) followed by the order of rice bran, beet pulp. Expecially, mycelial growth and density of oyster mushroom is the lowest at the mixture rate of 80% waste cotton(spinning) : 10% beet pulp. Mycelial growth and density of oyster mushroom. were the highest in the medium of cotton seed hull and beet pulp mixture followed by the order of rice bran, corn cob. Expecially, mycelial growth and density of oyster mushroom is the lowest at the mixture rate of 80% cotton seed hull : above 20% rice bran. Mycelial growth and density of oyster mushroom were the highest in the medium rate of 70% waste cotton(spinning), 10% corn cob and 10% beet pulp(V/V). Mycelial growth and density of oyster mushroom were the highest in the medium rate of 70% cotton seed hull , 10% corn cob and 10% beet pulp(V/V). Optimal concentration of NSM for the mycelial growth and density of oyster mushroom were shown to be 500 times concentration. Optimal water contents for the mycelial growth and density of NSM was 70%.

  • PDF

SMP (Symmetric Multi-Power) 안테나에 의한 플라즈마 밀도 분포 개선에 대한 연구

  • Lee, Jae-Won;Kim, Yeong-Cheol;Jeong, Jin-Uk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.558-558
    • /
    • 2013
  • 유도 결합 플라즈마는 반도체 및 디스플레이 플라즈마 공정에서 널리 사용되고 있으며, 이때 대표적인 플라즈마 변수인, 플라즈마 밀도, 전자 온도 그리고 그들의 공간 균일도는 공정결과 및 소자 품질에 직접적인 영향을 준다. 하지만, 기존의 통상적인 유도 결합 플라즈마에서의 안테나 구조는 용량성 결합에 의한 이온 에너지 손실, 불 균일한 플라즈마 밀도 분포 그리고 높은 안테나 전압을 야기한다. 이러한 한계를 극복하기 위하여 SMP, 다중 전력 인가 대칭형 안테나를 고안하여 플라즈마 밀도의 공간 균일도 개선하였다. 구조적으로 두 개의 안테나가 수평면 상에 일정한 간격으로 중첩되며, 전기적으로 다중 전력을 인가하여 안테나 임피던스를 낮추고 안테나 전압을 방위각상 균등 배분하여 용량성 결합 문제를 저감함으로서 플라즈마의 회전방향 균일도를 개선할 수 있었다.

  • PDF

공동주택에 있어서 중앙식과 개별식 가스난방의 경제적 특성에 관한 연구

  • 홍도유
    • 월간 기계설비
    • /
    • s.41
    • /
    • pp.64-79
    • /
    • 1993
  • 본 논문에서는 도시공해 방지를 위해 도시가스를 연료로 사용하는 경우 거주자의 생활수준이나 단지의 밀도 및 난방부하 설정등에 다소 차이는 있으나 소규모 고층 아파트(공동주택)의 난방방식중 중앙난방 방식과 개별난방 방식의 초기시설비, 연료비, 시설관리비의 경제성을 검토하고 난방 시스템의 지침을 제시하였다. 전체 공사비(초기투자비)는 개별난방 방식이 중앙난방 방식보다 약 2$\%$정도 절감되었다. 난방비와 시설관리에 따른 인건비 면에서도 난방의 경우 개별난방 방식이 중앙난방 방식에 비하여 난방과 하절기 온수만을 별도로 사용하는 경우 개별난방 방식이 중앙난방 방식보다 난방비가 9$\%$정도 더 들었으며, 시설관리 인건비 면에서는 중앙난방 방식보다 개별난방 방식이 66.7$\%$ 적게 들었다. 전체적으로 중앙난방 방식보다 개별난방 방식이 초기투자비 및 유지관리 면에서 경제성이 우수함이 확인되었다.

  • PDF

Anatomical Comparison between Compression Wood and Opposite Wood in a Branch of Ginkgo biloba L. (은행나무 지재(枝材)의 압축이상재(壓縮異常材)와 대응재(對應材)에 관(關)한 해부학적(解剖學的) 특성(特性) 비교(比較))

  • Eom, Young-Geun
    • Journal of the Korean Wood Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.77-85
    • /
    • 1991
  • 은행나무 지재(枝材)에 발달(發達)하여 있는 압축이상재(壓縮異常材)와 대응재(對應材)의 해부학적(解剖學的) 특성(特性) 차이(差異)를 조직(組織) 및 그 구성요소(構成要素)의 크기 면에서 서로 검토(檢討) 비교(比較)하였다. 조직적(組織的)인 특성(特性)으로는 압축이상재(壓縮異常材)가 연륜폭(年輪幅), 횡단면상(橫斷面上) 가도관(假導官) 형상(形狀) 및 방사조직(放射組織) 비례상태(比例狀態), 세포간극(細胞間隙), 가도관(假導官) 선단(先端)의 굴곡(屈曲), 나선열(螺旋裂) 및 접선단면상(接線斷面上)의 방사조직(放射組織) 형상(形狀) 면에서 대응재(對應材)와 차이(差異)를 나타냈으며 구성요소(構成要素)의 크기에 있어서는 가도관(假導官)의 벽후(壁厚) 및 접선직경(接線直徑), 단열(單列) 방사조직(放射組織)의 높이, 이열방사조직(二列放射組織)의 수(數) 및 방사조직(放射組織) 밀도(密度) 면에서 압축이상재(壓縮異常材)가 대응재(對應材)와 차이(差異)를 나타내는 것으로 여겨졌다.

  • PDF

공동주택에 있어서 중앙식과 개별식 가스난방의 경제적 특성에 관한 연구

  • 홍도유
    • 월간 기계설비
    • /
    • s.43
    • /
    • pp.76-82
    • /
    • 1994
  • 본 논문에서는 도시공해 방지를 위해 도시가스를 사용하는 경우 거주자의 생활 수준이나 단지의 밀도 및 난방부하 설정 등에 다소 차이는 있으나 소규모 고층아파트(공동주택)의 난방방식중 중앙난방 방식과 개별난방 방식의 초기 시설비, 연료비, 시설 관리비의 경제성을 검토하고 난방 시스템의 지침을 제시하였다. 전체 공사비(초기투자비)는 개별난방 방식이 중앙난방 방식 보다 약2$\%$정도 절감 되었다. 난방비와 시설관리에 따른 인건비 면에서도 난방의 경우 개별난방 방식이 중앙 난방방식에 비하여 난방과 하절기 운수만을 별도로 사용하는 경우 개별난방방식이 중앙난방방식보다 난방비가 9$\%$정도 더 들었으며, 시설관리 인건비 면에서는 중앙 난방 방식보다 개별난방 방식이 66.7$\%$ 적게 들었다. 전체적으로 중앙난방 방식보다 개별난방 방식이 초기투자비 및 유지관리 면에서 경제성이 우수함이 확인되었다. 본지에서는 삼익건설 기획관리부 홍도유 과장이 $\ulcorner$공동주택에 있어서 중앙식과 개별식 가스난방의 경제적 특성에 관한 연구$\lrcorner$ 자료를 지난 1월호엔 지면관계로 게재하지 못했음을 알려 드린다.

  • PDF

공동주택에 있어서 중앙식과 개별식 가스난방의 경제적 특성

  • 홍도유
    • 월간 기계설비
    • /
    • s.44
    • /
    • pp.90-101
    • /
    • 1994
  • 본 논문에서는 도시공해 방지를 위해 도시가스를 사용하는 경우 거주자의 생활 수준이나 단지의 밀도 및 난방부하 설정 등에 다소 차이는 있으나 소규모 고층아파트(공동주택)의 난방방식중 중앙난방 방식과 개별난방 방식의 초기 시설비, 연료비, 시설 관리비의 경제성을 검토하고 난방 시스템의 지침을 제시하였다. 전체 공사비(초기투자비)는 개별난방 방식이 중앙난방 방식 보다 약2$\%$정도 절감 되었다. 난방비와 시설관리에 따른 인건비 면에서도 난방의 경우 개별난방 방식이 중앙 난방방식에 비하여 난방과 하절기 운수만을 별도로 사용하는 경우 개별난방방식이 중앙난방방식보다 난방비가 9$\%$정도 더 들었으며, 시설관리 인건비 면에서는 중앙 난방 방식보다 개별난방 방식이 66.7$\%$ 적게 들었다. 전체적으로 중앙난방 방식보다 개별난방 방식이 초기투자비 및 유지관리 면에서 경제성이 우수함이 확인되었다. 본지에서는 삼익건설 기획관리부 홍도유 과장이 $\ulcorner$공동주택에 있어서 중앙식과 개별식 가스난방의 경제적 특성에 관한 연구$\lrcorner$ 자료를 이번 3월호를 끝으로 게재한다.

  • PDF