• Title/Summary/Keyword: 면진베어링

Search Result 57, Processing Time 0.036 seconds

Shaking Table Test of a 1/10 Scale Isolated Fifteen-story Flat Plate Apartment Building (면진층을 가지는 1/10 축소된 15층 무량판 아파트건물의 진동대 실험)

  • Chun, Young-Soo
    • Land and Housing Review
    • /
    • v.2 no.3
    • /
    • pp.287-297
    • /
    • 2011
  • This paper presents the results of performance verification tests of the isolated flat plate apartment building with the laminated rubber bearings. The shaking table test is carried out in CABR(China Academy of Building Research) with two 1/10 scale isolation and non-isolation models under 4 excitation waves. The shaking table test is proceeding from x axis, y axis and x+y axis with different amplitude of acceleration values. The results show that, to non-isolated model, the natural vibration period is remarkably decreased and entered non-linear condition after moderate earthquake. Its accelerations become lager with increasing storey number and completely collapsed under large earthquake. The inter-storey shifts largely exceed the limit values of regulated displacement angles. But to isolated model, the natural vibration period of isolated modal is almost the same in all conditions and still in its elastic condition. The earthquake loading is greatly reduced and the accelerations of superstructure are greatly reduced. The inter-storey drifts are very small and can be neglected. The isolated model is in translational state and can be seen as a rigid whole. The displacements of isolation layer are in the allowable range. This experiment demonstrates that the seismic isolation is very effective to mitigate the influence of earthquake on structures and it is possible to increase the serviceability due to decrease the floor acceleration. facilities from their good states that is superior to non-isolated structure.

On the stability of Rubber Isolation Bearings (면진 고무 베어링의 안정성에 대하여)

  • 이종세
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1998.10a
    • /
    • pp.85-92
    • /
    • 1998
  • As an analytical approach, the area reduction formula of rubber bearings has been proposed to account for the reduction in bucking load due to shear. The result obtained from the formula is presumed to be conservative but the degree of conservatism is unknown. This paper describes a numerical study which aims at determining the effect of high shear strain on the critical load of rubber bearings using a finite element analysis program. The results from the finite element analysis which accounts for both the material and geometric non-linearities are compared against the theoretical results in order to examine the validity of the theoretical formulas.

  • PDF

Evaluation of Seismic Performance for Various Types of Pile Head of Landing Pier (잔교식 안벽에서 말뚝 두부형식에 따른 내진성능 평가)

  • Jang In-Sung;Kwon O-Soon;Park Woo-Sun;Jeong Weon-Mu
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.17 no.2
    • /
    • pp.70-79
    • /
    • 2005
  • Most of landing piers in Korea employ the combination of vertical piles and batter piles, which shows good efficiency in static lateral resistance but poor seismic performance. Many attempts have continuously been made to increase the seismic performance of batter piles with various aseismatic systems. In this study, new types of aseismatic system were developed by use of rubber and ball bearing, and shaking table tests and 3 dim. numerical analyses were performed in order to compare the seismic performance for various types of pile head. The test and numerical analysis results show the high seismic performance of newly proposed systems and the applicability off dim. numerical analysis considering the non-linear behaviour of rubber and ball bearing systems.

Finite Element Analysis of Lead Rubber Bearing by Using Strain Energy Function of Hyper-Elastic Material (초탄성 재료의 변형률에너지함수를 이용한 LRB받침의 유한요소해석)

  • Cho, Sung Gook;Park, Woong Ki;Yun, Sung Min
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.36 no.3
    • /
    • pp.361-374
    • /
    • 2016
  • The material property of the rubber has been studied in order to improve the reliability of the finite element model of a lead rubber bearing (LRB) which is a typical base isolator. Rubber exhibits elastic behaviour even within the large strain range, unlike the general structural material, and has a hyper-elastic characteristics that shows non-linear relationship between load and deformation. This study represents the mechanical characteristics of the rubber by strain energy function in order to develop a finite element (FE) model of LRB. For the study, several strain energy functions were selected and mechanical properties of the rubber were estimated with the energy functions. A finite element model of LRB has been developed by using material properties of rubber and lead which were identified by stress tests. This study estimated the horizontal and vertical force-displacement relationship with the FE model. The adequacy of the FE model was validated by comparing the analytical results with the experimental data.

A Study on Testing of 1/4-scale and Full-size Seismic Isolation Bearings (축소모델과 실모델 면진베어링의 성능실험에 관한 연구)

  • 정민기;정지만;김두훈
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1996.04a
    • /
    • pp.194-202
    • /
    • 1996
  • An approach to increase the seismic resistance of large structures is to reduce the seismic forces, to which structures are subjected by base isolation systems. The anti-seismic performance of base-isolated beatings has been verified experimentally by shaking table tests. However, it may be difficult to perform the tests for the full-scale beatings of base-isolated structures. Therefore, the test program was designed to evaluate the reliability and properties of the beatings under a range of loading conditions including axial stress, loading frequency and direction, and temperature. The effects of scale were also evaluated by comparing the results of the 1/4-scale beatings with those from the full-scale bearings, and the ultimate behavior of both types of bearings with evaluated through a series of roll-out tests. This report draws comparisons among the different tests and bearings to determine the importance of various factors including load history, axial stress, and frequency. Comparisons between the 1/4-scale bearings were difficult because of the scaling effects in manufacturing and thermal radiation, but qualitative results from the 1/4-scale bearings can certainly be extrapolated the full-scale bearings.

  • PDF

Dynamic Stability Analysis of Base-Isolated Low-level Nonlinear Structure Under Earthquake Excitation (지진시 저층건물 면진구조의 비선형 동적 거동)

  • Mun, Byeong-Yeong;Gang, Gyeong-Ju;Gang, Beom-Su;Kim, Gye-Su
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.11
    • /
    • pp.1743-1750
    • /
    • 2001
  • This paper presents an analysis of nonlinear response of the seismically isolated structure against earthquake excitation to evaluate isolation performances of a rubber bearing. In the analysis of the vibration of building, the building is modeled by lumped mass system where the restoring force is considered as linear, bilinear and trilinear. Fundamental equations of motion are derived for the base isolated structure, and hysteretic and nonlinear-elastic characteristics are considered for a numerical calculation. The excitation levels are magnified fur the recorded strong earthquake motions in order to examine dynamic stability of the structure. Seismic responses (of the building are compared fur the each restoring force type. As a result, it is shown that the effect of the motion by the nonlinear response of the building is comparatively not so large from a seismic design standpoint. The responses of the isolated structures reduce sufficiently and controled the motion of the building well in a practical range. By increasing the acceleration of the earthquake, the yielding of the farce was occurred in the concrete and steel frame, which shows the necessity of the exact nonlinear dynamic analysis.

Seismic Design for Application of LNG Storage Tank Isolation System (LNG 저장탱크의 면진시스템 적용을 위한 내진설계)

  • Seo, Ki-Young;Park, Hyun-Jae;Kim, Nam-Sik;Kim, Jae-Min;Yang, Seong-Yeong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.3
    • /
    • pp.227-235
    • /
    • 2014
  • The demand of natural gas is gradually increasing as a clean fuel in the world. Therefore, LNG storage tanks and related facilities of the importance of leading a community-based facility have emerged. The seismic design of LNG storage tank including seismic analysis have been developed steadily. But, the seismic analysis and design techniques for LNG storage tanks are lacking, in Korea. Consequently, it is necessary to develop an analysis model that LNG storage tanks in isolation system can describe the behavior. Further, LNG storage tank capable of ensuring safety and economy, it is necessary to develop design techniques. The studies have suggested seismic design procedures of LNG storage tanks with isolation system including triple-FPB and idealized complex hysteresis model of triple-FPB.

Seismic design for application of LNG storage tank isolation system (LNG 저장탱크의 면진시스템 적용을 위한 내진설계)

  • Seo, Ki-Young;Park, Jae-Hyun;Yang, Seong-Yeong;Kim, Nam-Sik
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.10a
    • /
    • pp.132-138
    • /
    • 2013
  • Natural gas as a clean fuel of the world demand for the trend is gradually increasing demand for clean energy in the country and there is growing interest. Therefore, LNG storage tanks and related facilities in the country of the importance of leading a community-based facility has emerged. So common sense that an earthquake with a seismic isolation device LNG storage tank similar to the actual behavior of the analytical model which can describe the development and construction of storage tanks to enhance the safety and economic design techniques need to be developed. In this study, a base isolation system, seismic analysis procedure of LNG storage tanks, and Triple-FPB developed a mathematical model of the present crystallized and complexity factors to the sum over histories model simplifies the complex behavior of the LNG storage tank with base isolation system how to interpret the seismic isolation is proposed.

  • PDF

Buckling Behavior of Seismic Isolation Bearings (면진 고무베어링의 좌굴거동)

  • 이종세;오종원
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1999.04a
    • /
    • pp.187-194
    • /
    • 1999
  • Laminated rubber bearings are widely used as a key component in seismic isolation of structural systems subjected to earthquake loadings. The combination of rubber layers and reinforcing steel shims makes the bearings conditionally unstable similar to buckling of ordinary columns. The shear flexibility of these short columns can lead to relatively low buckling Toads which may be further reduced when high shear strains are simultaneously imposed As an analytical approach, the area reduction formula has been proposed to account for the reduction in buckling load due to shear, but the degree of conservatism is unknown. In order to complement analytical approaches, a non-linear finite element analysis can be used. In this paper, a numerical study which aims at determining the effect of high shear strain on the critical load of elastomeric bearings is presented. From the load-displacement curve at each specified shear displacement, the buckling load can be obtained using the Southwell procedures. The results obtained are then compared against the theoretical predictions in order to examine the validity and the conservatism of the theoretical formulas.

  • PDF

Experimental Study on Floor Isolation of Main Control Room of Nuclear Power Plant using LRB (Lead Rubber Bearing) (납-고무 베어링(LRB) 면진시스템을 적용한 원전주제어실의 진동대 실험)

  • Lee, Kyung-Jin;Ham, Kyung-Won;Suh, Yong-Pyo
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2005.03a
    • /
    • pp.429-436
    • /
    • 2005
  • In this study, we made two types of main control room floor systems (Type I, Type II) and several shaking table tests with and without isolation system were conducted to evaluate floor isolation effectiveness of LRB(Lead Rubber Bearing). Both type showed large difference according to input earthquake signals, but showed little difference according to floor type. It is required to make LRB of which design frequency is below 1Hz when applied to main control room of NPP, but considering much difficulties in making such LRB, it is recommended that consideration should be taken into account when applied to main control room of NPP.

  • PDF