• Title/Summary/Keyword: 먼지 오염

Search Result 459, Processing Time 0.047 seconds

Composition and pollution characteristics of PM10 and PM2.5 particles at Gosan site of Jeju Island in 2008 (PM10, PM2.5 미세먼지의 조성 및 오염 특성: 2008년 제주도 고산지역 측정 결과)

  • Lee, Soon-Bong;Jung, Duk-Sang;Cho, Eun-Kyung;Kim, Hyeon-A;Hwang, Eun-Yeong;Kang, Chang-Hee
    • Analytical Science and Technology
    • /
    • v.24 no.4
    • /
    • pp.310-318
    • /
    • 2011
  • The collection of atmospheric $PM_{10}$ and $PM_{2.5}$ particle samples was made at Gosan site of Jeju Island, which is one of the most representative background sites in Korea. Their chemical compositions have been analyzed to explore the pollution characteristics and emission sources. The mass concentrations of $PM_{10}$ and $PM_{2.5}$ particles were $37.6{\pm}20.1$ and $22.9{\pm}14.3{\mu}g/m^3$, respectively, with the content of $PM_{2.5}$ to $PM_{10}$ as 61%. The $PM_{2.5}/PM_{10}$ ratios of nss-$SO_4^{2-}$, $NO_3^-$, and $NH_4^+$ were 0.94, 0.56, 1.02, respectively, indicating that these components were distributed mostly in the fine fractions. Based on the factor analysis, it was found that the compositions of fine particles were mainly influenced by anthropogenic sources, followed by soil or marine sources. The results of the backward trajectory analysis indicate that the concentrations of nss-$SO_4^{2-}$, $NO_3^-$, $NH_4^+$, nss-$Ca^{2+}$, and Pb were high when the air parcels moved from the China continent, while relatively low with the air parcels coming from North Pacific Ocean and/or East Sea.

Assessment of PM-10 Monitoring Stations in Daegu using GIS Interpolation (공간 보간법을 이용한 도시지역 미세먼지 측정소의 배치 적절성 평가)

  • Kim, Hyo-Jeong;Jo, Wan-Kuen
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.20 no.2
    • /
    • pp.3-13
    • /
    • 2012
  • This study evaluated the feasibility of the location for PM-10 Monitoring Stations utilizing through GIS analysis. In addition, optimal sites were investigated to properly manage PM-10 which are closely related with public health. There are 11 PM-10 monitoring stations in Daegu area and the PM-10 data monitored at these stations are utilized to understand the overall status of PM-10 pollution. However, there are contrastive issues on the locations of current monitoring stations. Thus, this study prepared the map of PM-10 concentrations in Daegu area using IDW and Kriging techniques. Furthermore, average PM-10 concentrations were calculated using zonal statistical methods according to legal divisions and then, the current monitoring stations were evaluated whether their location is appropriate or not for PM-10 pollution distribution. It was found that, on the basis of yearly, seasonal and daily concentration analysis, the location of current PM-10 monitoring stations were not appropriate, particularly as they could not represent regional PM-10 pollution characteristics. In order to supplement this deficiency, seven sites(Namsandong, Namildong, Dongildong, Buksungro 1, Jongro 1, Hyangchondong and Haejeondong) commonly selected from each analytical step are suggested as additional PM-10 monitoring sites. It is further suggested that this kind of scientific evaluation for the location of PM-10 monitoring stations are needed in order to properly manage public heath in other cities as well as Daegu area.

Fine dust(PM10) emission calculated of Dong-Hae harbor around area using inverse modeling technique (역모델링 기법을 이용한 동해항 주변지역 미세먼지 배출량 산출)

  • Kim, Ji-Hyun;Park, Young-Koo
    • Journal of the Korean Applied Science and Technology
    • /
    • v.32 no.4
    • /
    • pp.649-660
    • /
    • 2015
  • Data obtained from the Calpuff inverse modeling estimate the emission amount of pollutants, and enable to establish the aim for reduction through the comparison of various cases. This study pursued to accumulate the fundamental data by the Calpuff inverse modeling for five areas in the vicinity of Donghae harbor, which focused on reduction of atmospheric fine dust. As a result of evaluation of the allowed emission amount for local sites, site-D required the most reduction, $4.95{\mu}g/m^2{\cdot}S$, based on the atmospheric guideline, $50{\mu}g/m^3$. The theoretical mitigation could decrease the average concentration of PM10 to $42.6{\mu}g/m^3$ for the study field (Donghae waste water treatment plant). Modeling only for site-A emission showed the potential concentration around the residential area of Donghae harbor, $40{\sim}50{\mu}g/m^3$. However, it will rise over $50{\mu}g/m^3$ with the addition of background level. Therefore no more emission would be allowed. Site-B including commercial area and unpaved field required the reduction of $0.11{\mu}g/m^2{\cdot}S$ due to vehicles and fugitive dust. Site-C and E did not emit additional pollutants.

Study of Smoking Booth Design for the Treatment of Hazardous Pollutants (유해오염물질 처리를 위한 흡연부스의 설계)

  • Kwon, Woo-Taeg;Kwon, Lee-Seung;Lee, Woo-Sik
    • Fire Science and Engineering
    • /
    • v.31 no.6
    • /
    • pp.107-111
    • /
    • 2017
  • The purpose of this study was to develop a Eco smoking booth that can effectively reduce hazardous pollutants generated during smoking and evaluate the efficiency and effectiveness of removing hazardous pollutants. The design and manufacture of an eco-friendly automatic smoking booth equipped with deodorizing facilities, such as inlet - HEPA filter - electrostatic precipitator (EP) - impregnated activated carbon - exhaust port, etc., and the efficiency of removing hazardous pollutants from inside and outside was measured and evaluated. The complex odor removal efficiency was 95.37% inside the smoking booth, and 97.38% at the exit of the preventive facility. The carbon monoxide removal efficiency was 94.25% in the inside and 98.32% in the outlet. In addition, the removal efficiency of particulate matter, (PM1, PM2.5, and PM10) inside the smoking booth was 98.59%, and 98.85% at the outlet. The total volatile organic compounds (TVOCs) decreased from $26,000{\mu}g/m^3$ to $5,203{\mu}g/m^3$ in the smoking booth, resulting in 79.99% removal efficiency. After the ventilator was operated, the measured effluent concentration was $5,019{\mu}g/m^3$, and the removal efficiency was 80.70%. Therefore, the smoking booth designed and manufactured through this study can be applied to the removal of harmful pollutants even in the small working environment in the future.

A Study on the Removal Efficiency Depending on Changes of Inflow Conditions in Vortex typed Non-point Pollutants Treatment Facility (와류형 비점오염저감시설의 유입 조건에 따른 제거효율 연구)

  • Yoon, Geun-Ho;Choi, Gye-Woon;Lee, Min-Hee
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.494-494
    • /
    • 2012
  • 비점오염이란 도시, 도로, 농지, 산지, 공사장 등 불특정 장소에서 발생되는 오염을 말하며 건기 시에는 오염물질이 토지에 축적되었다가 강우 발생 시 강우와 함께 유출되어 관리에 많은 어려움이 있다. 유출된 오염물질은 특별한 전처리 없이 하천이나 호소로 유입되어 각종 수질오염, 부영양화 및 생활환경에 많은 영향을 받게 되며 상수원수에 문제가 발생하게 된다. 비점오염원의 특징은 초기강우 유출수는 고농도이며 토사, 협잡물 등이 많이 포함되어 있다. 초기강우 발생형태는 수로의 형태, 노면상태 유역현상 및 강우도달시간 등 유역의 특성에 따라서 달라지며, 토지이용상황, 하수도 정비여부 등에 따라서 오염물질의 종류와 농도가 변한다. 도시지역과 도로주변에는 먼지, 쓰레기, 마모된 타이어 등이 축적되며, 임야 및 산림에서는 비료, 축분, 대기오염물질의 강하물 등이 축적이 되어 강우 시 빗물에 씻겨 인근 수계로 직접 방류된다. 팔당상수원 비점오염원 최적관리사업 기본계획 및 타당성조사사업이 실시되어 비점오염저감시설의 설치대상 대표지점이 선정되었다. 그리고 각 배수구역의 특성에 맞는 최적관리기술이 제시되었다. 하지만 몇몇 시설들은 기대한 결과에 못 미치는 성과를 내고 있다. 따라서 이번 연구에서는 이러한 비점오염저감시설의 시설형 중 하나인 와류형 비점오염저감시설의 운용에 따른 효율성 분석에 관한 연구를 실시하였다. 실험장치는 현재 운영되고 있는 와류형 비점오염저감시설 참고하여 실험장 조건에 맞춰 1/4축적의 정상모형을 제작하였고 저감시설로 유입되는 원수의 유량과 단차를 변화시켜 실험하였다. 저감시설의 유입조건이 변하게 되면 시설 내 유속, 체류시간 등 운전조건이 바뀌게 되므로 제거효율도 변하게 될 것이다. 저감효율산정은 시설로 유입된 유입수와 유출수의 SS농도를 이용하여 산정하였다. 와류형저감시설의 SS제거효율을 연구한 결과, 모형에서 유량 $0.0016m^3/s$, 단차 10cm 인 조건에서 8.7%로 가장 높은 효율이 측정되었다. 이를 원형에서의 조건으로 환산하면 유량 $0.0512m^3/s$, 고수조와 저감시설의 단차 40cm일 경우 가장 높은 효율이 나타난다. 이와 같은 이유는 시설에 유입되는 유량이 증가 할수록 내부의 유속이 증가해 저감시설 내 처리수의 체류시간 감소와 교란이 발생하여 저감효율이 떨어지는 것으로 사료된다.

  • PDF

Panel study of daily air pollution and health symptoms among primary schoolchildren in Seoul (서울지역 아동들의 봄철 대기오염물질과 건강자각증상 간의 관련성에 대한 패널연구)

  • Mun, Jeong-Suk;Kim, Yun-Sin;Lee, Jong-Tae;No, Yeong-Man;Lee, So-Dam;Hong, Seung-Cheol
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2005.11a
    • /
    • pp.126-129
    • /
    • 2005
  • 본 연구는 서울지역 초등학교 학생 4, 5, 6학년 남 ${\cdot}$ 녀 초등학생들을 대상으로 봄철 대기오염농도와 일별 자각증상 과의 관련성에 대한 패널연구를 수행하였다. 로지회귀분석방법 중 일반화 추정 방정식(generalized estimating equations:GEE)모델을 이용하여 통계분석을 실시한 결과로는 서울지역 초등학교 학생들은 호흡기 증상보다는 피부가려움이나 눈의 따가움 등의 자극증상에 호흡성먼지(PM10)와 아황산가스 그리고 이산화질소 등의 대기오염물질 농도와 관련성이 있는 것으로 추정되었다.

  • PDF

Development of Environmental Mobile Sensor Module for Subway Stations (지하철 역사내의 환경 모바일 센서 모듈 개발)

  • Kim, Gyu-Sik;Lee, Byung-Seok;Lee, Joon-Hwa;Kim, Jo-Chun
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.532-533
    • /
    • 2008
  • 본 논문에서는 하루에 수백만 명이 이용하는 지하철 역사내의 환경 관리를 유비쿼터스(Ubiquitous) 기술을 적용하여 실질적이고 효과적으로 실행하는 방안을 제안하고자 한다. 지하철 역사는 지하라는 특수한 환경이기 때문에 외부의 신선한 공기를 유입하여 역사내의 공기질을 쾌적하게 유지해야할 필요가 있다. 또한 실내 공기질을 오염시키는 환경가스나 미세먼지 등의 오염도에 대해서도 지속적으로 감시하여야 한다. 이를 위해 설치가 간편하고 소형의 측정 장치를 지하역사내의 주요 지점에 설치하여 오염물질을 측정하고 그 결과 데이터를 모으는 집중기(Collector)를 운영하여 최종적으로 측정 데이터를 중앙 서버까지 전송할 수 있다면 지하철 관리자에 의한 지하역사내의 오염물질을 효과적으로 관리 감독하는 종합적인 지하철 환경 관리시스템의 운영이 가능할 것으로 판단된다.

  • PDF

대구지역에서 배출된 1998년과 2004년의 대기오염물질배출량 비교 연구

  • Park, Myeong-Hui;Park, Min-Su;Kim, Hae-Dong
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2007.05a
    • /
    • pp.174-178
    • /
    • 2007
  • 본 연구에서는 1998년과 2004년의 대기오염물질배출량 분포를 비교하여 제시하였다. 결과는 아래와 같다. 첫 번째 오염물질별 배출량을 살펴보면 2004년이 1998년에 비해 질소산화물$(NO_x)$과 미세먼지(PM-10)은 증가하였고, 일산화탄소(CO)와 아황산가스$(SO_2)$는 감소하였다. 두 번째 오염원별 배출량을 살펴보면 1998년과 2004년 모두 모든 오염원에서 증가하는 경향을 보였으나 선 오염원의 배출량이 가장 뚜럿한 증가를 나타내었다. 이는 $SO_2$는 저황유 공급정책과 청정연료의 사용으로 인해 감소하였으며, $NO_x$와 PM-10 차량대수의 증가와 인구의 증가, 총에너지 수요의 증가가 원인으로 판단된다.

  • PDF

Development of ozone passive sampler with fluorescence intensity method (형광광도법을 이용한 오존 passive sampler의 개발)

  • 김한수;김선태;윤은영;김신도
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2001.11a
    • /
    • pp.245-246
    • /
    • 2001
  • 우리나라에서는 지금까지 대기 오염과 관련하여 환경기준 달성을 위한 정책수립에 있어서 대상물질은 주로 이산화황(SO$_2$)과 먼지(TSP) 등으로 경제개발과 산업발전과정 등에서 발생되는 오염물질이었다. 그러나 최근 몇 년사이 급격한 자동차의 증가로 인한 이산화질소(NO$_2$)와 휘발성유기화합물(VOCs)의 배출이 증가하고 있어 환경규제정책도 점차 변하고 있는 실정이다. 이러한 오염물질들이 대기중에서 태양복사에너지에 의해 광화학 반응을 일으켜 오존(ozone), PAN(peroxyacethyl nitrate), PBN(peroxy benzoyl nitrate), 아크로레인(carolein), 포름알데히드(HCHO, formaldehyde) 등 광화학 산화제를 생성하여 인체, 동ㆍ식물 및 재산상의 피해를 유발하고 있다. (중략)

  • PDF

A study on the Manufacture and Application of UV-Cured Multi-Function(Anti-Stain/Virus) Coating Compounds for PVC Tile (PVC 바닥상재용 광경화형 복합기능(내오염/항균)성 코팅액의 제조 및 응용에 관한 연구)

  • Yoon, Hyun-Jung;Park, Bo-Ram;Ha, Jin-Wook
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.05b
    • /
    • pp.953-956
    • /
    • 2010
  • 본 연구에서는 건축자재로 널리 사용되는 PVC바닥상재 표면에 내오염성과 항균성을 증가시키기 위한 광경화형 코팅액 개발에 관한 것이다. PVC 바닥상재용으로 사용되는 우레탄-아크릴 수지에 수용성 대전방지제와 항균제를 배합하여 오염 및 정전기로부터 보호하고 미생물에 의한 전염성질환을 예방할 수 있는 광경화형 내오염/항균 코팅액에 관한 실험을 수행하였다. 연구결과, 수지에 수용성대전방지제 15%와 항균제 1%를 혼합하여 제조한 코팅액을 Bar-coater No.12로 코팅한 표면이 전기저항($10^9\Omega/cm^2$), 내오염도(매직 Test, 먼지부착 Test) 및 부착력(100%) 양호, 항균성(99.99%)로 가장 좋은 물성을 보였다.

  • PDF