• Title/Summary/Keyword: 마찰 감쇠기

Search Result 50, Processing Time 0.024 seconds

Equivalent Viscous Damping Ratio of a Friction Damper Installed in a SDOF Building (단자유도 건물에 설치된 마찰감쇠기의 등가점성감쇠비)

  • Seong, Ji-Young;Min, Kyung-Won
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.2
    • /
    • pp.199-208
    • /
    • 2010
  • A friction damper installed at a building shows nonlinear behavior since its stick and slip states are occurred repeatedly depending on the amplitude of external loadings to dissipate input energy. Friction damping is existed for the building with a friction damper. In additionally viscous one is inherently included. Therefore, the building installed in such combined damping is quite involved to find the analytical solution. In this study, first, displacement and acceleration characteristics are identified based on the exact solution for a single-degree-freedom building with a friction damper having both friction and viscous damping. Second, in free vibration, the equivalent viscous damping ratio is obtained by the energy dissipation. Third, numerical analysis is carried out to find response configuration with various friction force ratios. Fourth, corresponding equivalent viscous damping ratio is derived with the finding that the response reaches into steady-state for both friction and viscous damped structure. It is deduced using balance of input external energy and output dissipation energy for steady-state response. Finally, the equivalent viscous damping ratios of free or harmonic vibration are verified through nonlinear analysis.

Transonic Aeroelastic Analysis of a Airfoil with Friction Damping (마찰 감쇠를 고려한 에어포일의 천음속 공탄석 해석)

  • Yoo, Jae-Han;Lee, In
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.11
    • /
    • pp.1075-1080
    • /
    • 2010
  • For the aeroelastic analysis of a wing with friction damping, coupled time integration method was used to obtain time responses in the subsonic and transonic regions. To take into account aerodynamic nonlinearity induced by shock wave on the lifting surface, transonic small disturbance equation with in-phase periodic boundary condition was used for unsteady aerodynamic calculation. For 2-DOF airfoil system with displace-dependent friction dampers, the effects of normal load slope and Mach number on flutter boundary were investigated.

Optimal Design of Friction Dampers based on the Story Shear Force Distribution of a Building Structure (건축구조물의 층전단력 분포에 기초한 마찰감쇠기의 최적설계)

  • Lee, Sang-Hyun;Min, Kyung-Won;Park, Ji-Hun;Lee, Roo-Jee
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.6 s.46
    • /
    • pp.21-30
    • /
    • 2005
  • In this study, a seismic design methodology for friction dampers based on the story shear force distribution of an elastic building structure is proposed. First, using two normalization methods for the slip-load of a friction damper, numerical analyses of various single-degree-of-freedom systems are peformed. From those analyses, the effect of the slip-load and the brace stiffness was investigated and the optimal silliness ratio of the brace versus original structure was found. Second, from the numerical analysis for five multi-story building structures with different natural frequency and the number of story, reasonable decision method for the total number of installation floor, location of installation and distribution of the slip-loads are drawn. In addition, an empirical equation on the optimal number of installation floor is proposed. Finally, the superiority of the proposed method compared to the existing design method is verified from the numerical analysis using real earthquake data.

Seismic Retrofit Design Procedure Using a Friction Damper (마찰 감쇠기를 사용한 구조물의 보강 설계법 제안)

  • Moon, Ki-Hoon;Han, Sang-Whan;Jo, Han-Chul;Lee, Kang-Seok
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.15 no.6
    • /
    • pp.45-53
    • /
    • 2011
  • The purpose of this study was to propose a design procedure for a damped structure with a friction damper for an existing structure. The target displacement of the damped structure was determined using the maximum displacement of the existing structure. The displacement of the damped structures was predicted using a proposed equation for the inelastic displacement ratio. For this study, we conducted a nonlinear response history analysis using 80 earthquake ground motions to verify the validity of the proposed design procedure by comparing the responses of the damped and undamped structures. Based on the dynamic analysis results, it was concluded that the predicted displacement of the damped structure using the proposed design procedure matched well with the analysis results.

Numerical Study of Hybrid Base-isolator with Magnetorheological Damper and Friction Pendulum System (MR 감쇠기와 FPS를 이용한 하이브리드 면진장치의 수치해석적 연구)

  • Kim, Hyun-Su;Roschke, P.N.
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.2 s.42
    • /
    • pp.7-15
    • /
    • 2005
  • Numerical analysis model is proposed to predict the dynamic behavior of a single-degree-of-freedom structure that is equipped with hybrid base isolation system. Hybrid base isolation system is composed of friction pendulum systems (FPS) and a magnetorheological (MR) damper. A neuro-fuzzy model is used to represent dynamic behavior of the MR damper. Fuzzy model of the MR damper is trained by ANFIS (Adaptive Neuro-Fuzzy Inference System) using various displacement, velocity, and voltage combinations that are obtained from a series of performance tests. Modelling of the FPS is carried out with a nonlinear analytical equation that is derived in this study and neuro-fuzzy training. Fuzzy logic controller is employed to control the command voltage that is sent to MR damper. The dynamic responses of experimental structure subjected to various earthquake excitations are compared with numerically simulated results using neuro-fuzzy modeling method. Numerical simulation using neuro-fuzzy models of the MR damper and FPS predict response of the hybrid base isolation system very well.

Approximate solution for a building installed with a friction damper : revisited and new result (마찰감쇠기가 설치된 건물 응답의 근사해 : 재 고찰 및 새로운 결과)

  • Min, Kyung-Won;Seong, Ji-Young;Lee, Sung-Kyung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.850-854
    • /
    • 2009
  • Approximate analysis for a building installed with a friction damper is revisited to get insight of its dynamic behavior. Energy balance equation is used to have a closed analytical form solution of dynamic magnification factor (DMF) for the building with combined viscous and friction damping. It is found out that DMF is dependent on friction force ratio and resonance frequency. Linear transfer function from input external force to output building displacement is obtained by simplifying DMF equation. Root mean square of building displacement is derived under earthquake-like random excitation. Finally, design of friction damper is proposed by processing target control ratio, damping ratio factor, and friction force in sequence.

  • PDF

Development an Empirical Formula for the Friction Coefficient of a Circular Friction Damper (원형 마찰 감쇠기 특성의 실험식 개발)

  • Shin, Yong-Woo;Lee, Sang-Kwon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.6
    • /
    • pp.491-498
    • /
    • 2011
  • The structural vibration due to earthquake or outside impact causes serious problem for building safety. A dynamic model of a friction damper which can be constructed and installed easily is needed to reduce the vibration of the building. In this paper, the experimental equation of a circular friction damper is derived and designed for reduction of a earthquake vibration of a building. The developed experimental equation is defined to simply design the capacity on design of the circular friction damper based on the results of the performance test. Finally this experimental equation can be used for the design of a circular friction damper.

Response Reduction of a SDOF Structure based on Friction Force Ratio of MR Controller (MR제어기의 마찰력비에 따른 단자유도 구조물의 응답감소)

  • Seong, Ji-Young;Min, Kyung-Won
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.4
    • /
    • pp.435-443
    • /
    • 2010
  • This study presents key parameters for the structure installed with MR controller in reducing its responses. MR controller is regarded as Bingham model of which control forces are frictional and viscous ones. The parameters are identified as friction force ratios, $R_f$ and $R_h$ which are, respectively, ratio of MR controller friction force to static restoring force for free vibration and ratio of the friction force to amplitude of harmonic force. Structure-MR controller system shows nonlinear response behavior due to friction force. Energy balance strategy is adopted to transform the behavior to linear one with equivalent damping ratio. Finally, proposed equivalent linear process is compared to the nonlinear one, which turns out to give acceptably good results.