• Title/Summary/Keyword: 마찰형 감쇠장치

Search Result 9, Processing Time 0.025 seconds

Probability Distribution of Displacement Response of Structures with Friction dampers Excited by Earthquake Loads Generated Using Kanai-Tajimi Filter (Kanai-Tajimi 필터 인공지진 가진된 마찰형 감쇠를 갖는 구조물의 변위 응답 확률분포)

  • Youn, Kyung-Jo;Park, Ji-Hun;Min, Kyung-Won;Lee, Sang-Hyun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.5
    • /
    • pp.623-628
    • /
    • 2007
  • The accurate peak response estimation of a seismically excited structure with frictional damping system(FDS) is very difficult since the structure with FDS shows nonlinear behavior dependent on the structural period, loading characteristics, and relative magnitude between the frictional force and the excitation load. Previous studies have estimated that by replacing a nonlinear system with an equivalent linear one or by employing the response spectrum obtained based on nonlinear time history and statistical analysis. In the case that an earthquake load is defined with probabilistic characteristics, the corresponding response of the structure with FDS has probabilistic distribution. In this study, nonlinear time history analyses were performed for the structure with FDS subjected to artificial earthquake loads generated using Kanai-Tajimi filter. An equation for the probability density function (PDF) of the displacement response is proposed by adapting the PDF of the normal distribution. Finally, coefficients of the proposed PDF are obtained by regression analysis of the statistical distribution of the time history responses. Finally the correlation between PDFs and statistical response distribution is presented.

Shaking Table Test of a Full Scale 3 Story Steel Frame with Friction Dampers (마찰형 감쇠장치가 설치된 실물크기 3층 철골프레임의 진동대 실험)

  • Bae, Chun-Hee;Kim, Yeon-Whan;Lee, Sang-Hyun;Park, Young-Pil
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.9
    • /
    • pp.862-873
    • /
    • 2007
  • Energy dissipation devices can be considered as an alternative for the seismic performance enhancement of existing structures based on the strengthened seismic design code. In this study, seismic response mitigation effects of friction dampers are investigated through the shaking table test of a full scale 3 story building structure. Frist, the bilinear force-displacement relationship of a structure-brace-friction damper system and the effect of brace-friction damper on the increase of frequency and damping ratio are identified. Second, frequency, displacement, and torque dependent characteristics of the friction damper are investigated by using harmonic load excitation tests. Finally, the shaking table tests are performed for a full scale 3 story steel frame. System identification results using random signal excitation indicated that brace-friction damper increased structural damping ratio and frequency, and El Centro earthquake test showed that brace-friction damper reduced the peak displacement and acceleration significantly. In particular, it was observed that the damping effect due to friction damper becomed obvious when the structure was excited by more intensive load causing frequent slippage of the friction dampers.

Analysis of Performance Tests and Friction Characteristics of a Friction Type Isolator Considering Train Load Conditions (열차 하중조건을 고려한 마찰형 방진장치 성능시험 및 마찰특성 분석)

  • Koh, Yong-Sung;Lee, Chan-Young;Ji, Yong-Soo;Kim, Jae-Wang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.694-702
    • /
    • 2017
  • In the case of an elevated railway station, structure borne noise and vibration due to structural limitations allow the load and vibration from railway vehicles to be directly transmitted to the station structure, resulting in an increase in the number of civil complaints from customers and staff of the station. The floating slab track system, which is well known as one of the solutions for reducing the noise and vibration from elevated railway stations, usually contains rubber mounts or rubber pads under the railway slab which act as a damper. These types of device have the disadvantage that is difficult to predetermine the exact stiffness and damping ratio under the nonlinear loads resulting from train services. In this study, an isolator with a friction type of wedge is introduced, which can be applied to floating slab track systems and to be designed with precisely the required stiffness. Furthermore, a comparative analysis of the stiffness between the designed and experimental values is carried out, while the damping ratio, which is closely related to the friction wedge blocks, is deduced according to the train load condition. The performance tests of the isolator were conducted in accordance with the DIN 45673-7 standard which includes both static and dynamic load tests. The load conditions for the performance tests are designed to conform to the DIN standard related to the weight of the train and rail track, in order to perform vertical and horizontal load tests, so as to ensure the secure structural safety of the railway. Also, by checking the change aspect of the friction coefficients of the friction elements according to the loading rate, the vibration reduction performance of the friction type isolator with variable loading rate conditions is examined.

Experimental Evaluation for Structural Performance of Hybrid Damper Combining Steel Slit and Rotational Friction Damper (강재 슬릿과 회전 마찰형 감쇠 장치를 결합한 복합 감쇠 장치의 실험적 구조 성능 평가)

  • Kim, Yu-Seong;Kang, Joo-Won;Park, Byung-Tae;Lee, Joon-Ho
    • Journal of Korean Association for Spatial Structures
    • /
    • v.19 no.3
    • /
    • pp.101-109
    • /
    • 2019
  • In order to develop the compatible damping device in various vibration source, a hybrid wall-type damper combining slit and friction damper in parallel was developed. Cyclic loading tests and two-story RC reinforced frame tests were performed for structural performance verification. As a result of the 5-cyclic loading test according to KBC-2016 and low displacement cyclic fatigue test, The hybrid wall type damper increased its strength and the ductility was the same as that of the slit damper. In addition, As a result of the two-layer frame test, the reinforced frame had about twice the strength of the unreinforced frame, and the story drift ratio was satisfied to Life Safety Level.

Vertical Vibration Isolator for Reducing Structural Vibration (구조물의 진동저감을 위한 수직형 면진장치)

  • Choi, Sanghyun;Baek, Joon-Ho;Lee, You In
    • Journal of the Society of Disaster Information
    • /
    • v.8 no.2
    • /
    • pp.197-203
    • /
    • 2012
  • In these days, the design of a structure for reducing or eliminating noise and vibration is getting more important, as the social demands for reducing environmental pollution rise. In this paper, the basic concept and performance verification test results of the recently developed vertical vibration isolator are presented. The isolator attenuates vibration using the damping action from the friction plane made of PTFE and provides the restoring force from the polyurethane springs arranged in vertical and horizontal directions. The performance verification tests consist of a test for identifying performance change during load rate variation and a test for confirming the force-displacement relationship assumption in vibration force range.

Seismic Response Control of Structures Using Decentralized Response-Dependent MR Dampers (분산제어식 응답의존형 MR 감쇠기를 이용한 구조물의 지진응답제어)

  • Youn, Kyung-Jo;Min, Kyung-Won;Lee, Sang-Hyun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.6
    • /
    • pp.761-767
    • /
    • 2007
  • In centralized control system, complicated control systems including sensors, power supply and dampers should be required to satisfy the target response of large-scale structures. The practical applications of the centralized control system, however, is very difficult due to high order finite element model of structures, uncertainty of models, and limitations of the excitation system. In this study, the decentralized response-dependent MR damper of which magnetic field is automatically modulated according to the displacement or velocity transferred to the damper without any sensing and computing systems. this decentralized response-dependent MR damper are investigated according to the ranges of relative magnitude between the control force of MR damper and the story shear force of structures by nonlinear time history analysis. Finally, its performance is compared with centralized LQR algorithm which is used in general centralized control theory for a three story building structure.

활동형 지진격리 시스템을 적용한 지진격리 교량의 비선형 유한요소해석(S/W:ABAQUS, H/W:CrayC94)

  • 음성우
    • Computational Structural Engineering
    • /
    • v.11 no.1
    • /
    • pp.38-45
    • /
    • 1998
  • 최근 국내외에서 활발히 개발되고 있는 지진격리 시스템은 원자력 발전소, 교량, 중요한 공공건물 등의 지진피해를 최소화하기 이하여 널리 적용되고 있다. 그리고 다른 방법에 비하여 경제성 및 효율성이 우수하기 때문에 관련 연구 및 응용이 활발히 진행되고 있다. 이에 따라 국내외에서 격리시스템의 비선형성과 구조물의 불연속성을 고려한 지진격리 구조물의 해석을 통한 거동을 규명하는 연구가 과거 수년간 활발히 진행되어 왔다. 당사(금호건설)는 상부하중 지지능력과 감쇠능력이 우수한 지진격리장치를 개발하였으며 지진격리장치를 설치한 교량의 지진해석을 수행하여 본 지진격리 시스템의 이론적 성능을 파악하였다. 본 수치해석은 CrayC94에 탑재된 비선형 해석에 뛰어난 것으로 알려진 ABAQU를 이용하였다. 본 지진격리 시스템은 적층고무받침(Laminated Rubber Bearing)과 PTFE 미끄럼받침으로 구성되어 있으며, 적층고무받침은 주로 복원력을 제공하며 PTFE 미끄럼받침은 상부하중을 지지하며 마찰감쇠를 제공하여 에너지를 소산하는 역할을 한다. 본 수치해석에서는 선형스프링과 마찰요소를 이용하여 각각을 모형화하였다. 개발된 지진격리 시스템이 주로 사용될 상판자중이 무거운 다경간 연속 PC Box Girder교를 모델교량으로 선택하여 해석을 수행하였으며 수치해석에 사용된 격리시스템의 사전에 수행된 동특성 실험결과를 활용하였다. 이러한 해석을 통하여 이론적 효율성을 파악할 수 있었다.

  • PDF

A Behavior Test on a Frictional-Wedge-Type Vibration Isolation Device for Vibration Reduction of a Railway Track (열차 진동 저감을 위한 마찰쐐기형 방진장치의 거동 시험)

  • Lee, Chanyoung;Choi, Sanghyun;Lee, Yooin;Kwon, Segon;Koh, Yongsung;Ji, Yongsoo
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.1
    • /
    • pp.45-54
    • /
    • 2015
  • In the case of railway facilities in cities such as a railway station or a bridge, the significance of design for reducing vibration and noise is getting more significant. The vibration control solution is in need especially for an elevated railway station to block vibration of a train and secondary noise effectively. Even though a vertical vibration isolation device is able to be applied effectively to railway facilities such as elevated railway stations which transfer vibration directly from a train to a structure, the development of the vertical device is much slower than a horizontal vibration isolation device. In this paper, a vibration isolation device using wedge type friction material which is currently developing to reduce train-induced vibration effectively is introduced and test results for verification of dynamic performance is also presented. The vibration test on a concrete structure equipped with the developed vibration isolation device is conducted through which the isolation performance and dynamic properties are verified and needs for improving the performance of the device is identified.

TheSimulation of the Characteristics of the Levitation Force in Superconductor using 2D Slab model (2차원 Slab모델을 이용한 초전도체 부상력 특성의 시뮬레이션)

  • 유제환;임윤철
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1997.10a
    • /
    • pp.167-172
    • /
    • 1997
  • 초전도체를 기계요소중 하나인 베어링에 응용하기 위한 연구는 임계온도가 액체질소의 비등점(77K)보다 높은 산화물 고온 초전도체가 발견된 이후 시작되었으며, 특히 최근에는 $10^4A/cm^2$이상의 임계전류밀도를 갖는 덩어리형 고온 초전도체가 용융공정을 통해 개발되어, 큰 부하지지력을 갖고 10$^{-8}$ 이하의 마찰계수를 갖는 초전도 마그네틱 베어링으로서 플라이휠 같은 에너지 저장장치에 적용시키는 연구가 국내외적으로 진행되고 있다. 고온 초전도체를 사용한 반발식 수동형 미그네틱 베어링은 Meissner effect뿐 아니라 Fluxpinning effect에 의해 자체적으로 외란에 대한 위치안정성을 가지며, 히스테리시스 손실에 의한 에너지 소산을 통해 외란에 대해 강한 감쇠능력을 가진다는 장점을 가지고 있으며, 대중량을 지지할 수 있다. 이러한 초전도체의 특성에 관한 정량적 수치해석은 초전도 베어링의 설계에 필수적이나 아직 국내에서는 그러한 시도가 없었다. 이러한 여건을 고려하여 본 연구에서는 초전도체와 자석간의 부상력 변화를 2차원 Slab모델로 수치해석하여 히스테리시스라는 주요한 특성을 고찰하고자 한다.

  • PDF