• Title/Summary/Keyword: 마이크로 히터

Search Result 74, Processing Time 0.026 seconds

Surface Temperature Measurement in Microscale with Temperature Sensitive Fluorescence (온도 민감 형광을 이용한 마이크로 스케일 표면온도 측정)

  • Jung Woonseop;Kim Sungwook;Kim Ho-Young;Yoo Jung Yul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.2 s.245
    • /
    • pp.153-160
    • /
    • 2006
  • A technique for measuring surface temperature field in micro scale is newly proposed, which uses temperature-sensitive fluorescent (TSF) dye coated on the surface and is easily implemented with a fluorescence microscope and a CCD camera. The TSF dye is chosen among mixtures of various chemical compositions including rhodamine B as the fluorescent dye to be most sensitive to temperature change. In order to examine the effectiveness of this temperature measurement technique, numerical analysis and experiment on transient conduction heat transfer for two different substrate materials, i. e., silicon and glass, are performed. In the experiment, to accurately measure the temperature with high resolution temperature calibration curves were obtained with very fine spatial units. The experimental results agree qualitatively well with the numerical data in the silicon and glass substrate cases so that the present temperature measurement method proves to be quite reliable. In addition, it is noteworthy that the glass substrate is more appropriate to be used as thermally-insulating locally-heating heater in micro thermal devices. This fact is identified in the temperature measuring experiment on the locally-heating heaters made on the wafer of silicon and glass substrates. Accordingly, this technique is capable of accurate and non-intrusive high-resolution measurement of temperature field in microscale.

Thermo-Optically Tunable Filter Using Evanescent Field Coupling Between Side-Polished Polarization Maintaining Fiber and Polymer Planar Waveguide (측면 연마된 편광유지 광섬유와 폴리머 평면도파로 사이의 소산장 결합을 이용한 열 광학 가변 필터)

  • 윤대성;김광택
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.2
    • /
    • pp.33-38
    • /
    • 2004
  • We have demonstrated a tunable Inter based on an asymmetric directional coupler made of a side-polished polarization maintaining fiber coupled with a polymer planar waveguide. The thermo-optic effects of the polymer planar waveguide induced by a micro-strip heater placed on the top layer of the device leads to shift of resonance wavelength of the coupler. The fabricated device exhibited wide tunable range exceeding 230 nm with 720 ㎽ of applied electrical power.

Design and Fabrication of microheaters based oil polycrystalline 3C-SiC with large uniform-temperature area for high temperature (다결정 3C-SiC 기반으로 한 넓은 범위에서 균일한 온도 분포를 갖는 초고온용 마이크로 히터 설계 및 제작)

  • Jeong, Jae-Min;Chung, Gwiy-Sang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.214-215
    • /
    • 2009
  • This paper presents the fabrication and characteristics of microheaters, built on AlN(0.1 um)/3C-SiC(1 um) suspended membranes. Pt was used as microheater and temperature sensor materials. The results of simulated are shown that AlN/3C-SiC membrane has more large uniform-temperature area than $SiO_2$/3C-SiC membrane. Resistance of temperature sensor and power consumption of microheater were measured and calculated. Pt microheater generates the heat of about $550^{\circ}C$ at 340 mW and TCR of Pt temperature sensor is about 3188 ppm/$^{\circ}C$.

  • PDF

An Experimental Study on Direct Cooling Performance using Pool Boiling from Micro-Porous Coated Surface (마이크로다공성 코팅된 발열체에서의 풀비등 직접냉각 성능에 관한 실험적 연구)

  • Kim, Tae-Gyun;Lee, Kyu-Jung;Kim, Yong-Chan;Park, Chan-Sung
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1353-1358
    • /
    • 2004
  • An experimental study of pool boiling behavior on micro-porous enhanced square heater surfaces immersed in PF5060 is performed. The effects of heater orientation, Subcooling and substrate distance on the pool boiling heat transfer performance for the double heaters were investigated under increasing heat-flux conditions. The boiling performance of micro-porous coated surface was better than that of plain surface. The double heaters with upper substrate of 0.2cm substrate interval have lower boiling performances compared with the results for the double heaters with that of 0.5cm and 1.0cm substrate interval and without the substrate. In comparison to upper heater and below heater with orientation, the upper heater has lower superheat temperature than the below heater due to the bubble sweeping.

  • PDF

Design on ultra low power consumption microhotplates based on 3C-SiC for high temperatures (고온용 저전력소비형 3C-SiC 마이크로 히터의 설계)

  • Jeong, Jae-Min;Chung, Gwiy-Sang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.385-386
    • /
    • 2008
  • This paper reports the design of the ultra low power consumption microhotplates for high temperatures. The microhotplates consisting of a platinum-based heating element on AlN/poly 3C-SiC layers were designed. The microhotplate is a $600\times600{\mu}m^2$ square shaped membrane made of $1{\mu}m$ thick ploy 3C-SiC suspended by four legs. The microhotplate was compared with $Si_3N_4/SiO_2/Si_3N_4$(NON) structure microhotplate by COMSOL simulation system. Thermal uniformity, power consumption and thermal characterizations of microhotplates based on 3C-SiC thin film are better than microhotplates with NON structure.

  • PDF

Temperature Measurements in a Microfluidic Chip with Polydiacetylene Sensor (폴리다이아세틸렌을 이용한 미세유동칩 내의 온도 측정)

  • Jang, Young-Sik;Ryu, Sung-Min;Song, Si-Mon
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2696-2699
    • /
    • 2008
  • Microfluidic chips have been frequently utilized to perform biochemical analysis, like cell culture, because they reduce the consumptions of analytes and reagents and automate multi-step analysis processes. It is often critical to monitor temperature in a microchannel for the analyses in order to control a reaction condition of bio or chemical molecules. We propose a novel method to monitor temperature of a microchannel flow by using polydiacetylene (PDA), a conjugated polymer, that has a unique property to transform its color from visible blue to fluorescent red by thermal stress. We inject PDA sensor droplets generated by hydrodynamic instability into a microchannel with a microheater incorporated on the channel bottom. Also, we change the channel temperature by providing the different electric power to the microheater. The results show that the florescence intensity of PDA sensor droplets linearly increases in response to the flow temperature increase within a certain range.

  • PDF

Micro Heater Trimming using UV Laser (UV레이저를 이용한 마이크로 히터 트리밍)

  • Yoo, Seungryeol
    • Journal of the Semiconductor & Display Technology
    • /
    • v.16 no.3
    • /
    • pp.36-40
    • /
    • 2017
  • In this paper, a new method of laser trimming of thick film heater is studied. Various laser waves (IR, Green, UV) are used to ablation the heater and the process parameters are also presented. For given initial printed resisters, the cutting length should be prepared to obtain the target resister value in advance. Therefore, the cutting model is very important. The well-known model was tested and proven that it is valid only within a certain range of cutting length. A new model is proposed for a wide range of resister laser trimming. The cutting lengths and resister variation was obtained and formulated. To verify the presented method, the cutting lengths of each resister are calculated for various target resister value and laser trimming using UV is conducted.

  • PDF

Flexible Carbon/PDMS Composite for the Application of Sensor (신축성을 가진 Carbon/PDMS 복합체의 센서 응용 연구)

  • Lee, Junho;Park, Kyoung Ryeol;Mhin, Sungwook
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.28 no.4
    • /
    • pp.73-77
    • /
    • 2021
  • Flexible electrodes for wearable devices have been actively studied in not only achieving mechanical/electrical stability, but also providing various functionalities for extending its industrial application. In this study, a flexible carbon/PDMS composite is prepared by addition of carbon black (CB) as a conductive filler, and effect of CB with different contents on electrical properties of the composite was investigated for the application of flexible electrodes, temperature sensor and heater. With increase of CB contents, resistivity of the carbon/PDMS was increased, and excellent durability was observed, confirmed by repetitive stretching deformation test. Resistance increase of the carbon/PDMS with temperature reveals the property of positive temperature coefficient, which can be applied for temperature sensor. Also, joule heating on the carbon/PDMS was observed when electrical potential was applied, indicating the applicability of the carbon/PDMS for heater.

Development of having double-chamber in micro-bubble pump (두 개의 챔버를 갖는 마이크로 버블펌프의 개발)

  • 최종필;박대섭;반준호;김병희;장인배;김헌영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1186-1190
    • /
    • 2003
  • In this paper, a valveless bubble-actuated fluid micropump was has been developed and its performance was tested. The valveless micropump consists of the lower plate, the middle plate, the upper plate and a resistive heater. The lower plate includes the nozzle-diffuser elements and the double-chamber. Nozzle-diffuser elements and a double-chamber are fabricated on the silicon wafer by the DRIE(Deep Reactive Ion Etching) process. The lower plate also has inlet/outlet channels for fluid flow. The middle plate is made of glass and plays the role of the diaphragm. The chamber in the upper plate is filled with deionized water, and which contacts with the resistive heater. The resistive heater is patterned on a silicon substrate by Ti/Pt sputtering. Three plates and the resister heater are laminated by the aligner and bonded in the anodic bonder. Since the bubble is evaporated and condensed periodically in the chamber, the fluid flows from inlet to outlet with respect to the diffusion effect. In order to avoid backflow, the double chamber system is introduced. Analytical and experimental results show the validity of the developed double-chamber micropump.

  • PDF

Anisotropic Wet Etching of Single Crystal Silicon for Formation of Membrane Structure (멤브레인 구조 제작은 위한 단결정 실리콘의 이방성 습식 식각)

  • 조남인;강창민
    • Journal of the Semiconductor & Display Technology
    • /
    • v.2 no.4
    • /
    • pp.37-40
    • /
    • 2003
  • We have studied micro-machining technologies to fabricate parts and sensors used in the semiconductor equipment. The studies were based on the silicon integrated circuit processes, and composed of the anisotropic etching of single crystal silicon to fabricate a membrane structure for hot and cold junctions in the infrared absorber. KOH and TMAH were used as etching solutions for the anisotropic wet etching for membrane structure formation. The etching characteristic was observed for the each solution, and etching rate was measured depending upon the temperature and concentration of the etching solution. The different characteristics were observed according to pattern directions and etchant concentration. The pattern was made to incline $45^{\circ}$ on the primary flat, and optimum etching property was obtained in the case of 30 wt% and $90^{\circ}C$ of KOH etching solution for the formation of the membrane structure.

  • PDF