• Title/Summary/Keyword: 마이켈슨 간섭계

Search Result 38, Processing Time 0.031 seconds

Investigation of the Polarization Cross-Coupling in Fiber Coils Using White Light Michelson Interferometer (백색광 마이켈슨 간섭계를 이용한 광섬유 고리의 편광 교차결합 측정)

  • Jo, Min-Sik;Do, Jae-Chul
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.9 no.3
    • /
    • pp.109-115
    • /
    • 2006
  • The investigation of the polarization cross-coupling in fiber coils was made using white light Michelson interferometer. The white light interferometer has a light source of about 13nm spectral bandwidth and measurement resolution of less than -80dB. The measurement found that the 200m fiber coil has a polarization cross-coupling of about -64dB in average and -46dB in maximum.

Application of Optical Frequency Comb Generator for Biomedical Measurement (Optical Frequency Comb Generator의 생체 측정 응용)

  • Lee, Ho-Guen;Kim, Sheen-Ja;Hwang, Dae-Seok;Lee, Young-Woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.1
    • /
    • pp.441-444
    • /
    • 2005
  • 본 논문은 Optical Frequency Comb Generator(OFCG)fmf 이용 생체 조직의 빠른 측정을 달성하기 위한 이론적 해석을 수행하였다. 생체 조직의 고속 검출을 위해 두 개의 OFCG를 이용하여 마이켈슨 간섭계를 설계하고 수치해석을 행하였다. 수치해석 결과 기존의 기계적 방식의 마이켈슨 간섭계에 비해 수백배이상의 빠른 검출 및 해상도가 가능할 것으로 예상된다.

  • PDF

Application of Optical Frequency Comb Generator for Biomedical Measurement (Optical Frequency Comb Generator의 생체 측정 응용)

  • Lee, Ho-Guen;Kim, Sheen-Ja;Hwang, Dae-Seok;Lee, Young-Woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.1
    • /
    • pp.339-342
    • /
    • 2005
  • 본 논문은 Optical Frequency Comb Generator(OFCG)fmf 이용 생체 조직의 빠른 측정을 달성하기 위한 이론적 해석을 수행하였다. 생체 조직의 고속 검출을 위해 두 개의 OFCG를 이용하여 마이켈슨 간섭계를 설계하고 수치해석을 행하였다. 수치해석 결과 기존의 기계적 방식의 마이켈슨 간섭계에 비해 수백배이상의 빠른 검출 및 해상도가 가능할 것으로 예상된다.

  • PDF

A Study on the Interferometer Configuration for Improvement of Signal-to-Noise Ratio of Optical Coherence Tomography System (OCT 시스템의 SNR 향상을 위한 간섭계 개선에 관한 연구)

  • Yang, Sung-Kuk;Park, Yang-Ha;Chang, Won-Suk;Oh, Sang-Ki
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.126-131
    • /
    • 2004
  • As a noninvasive imaging method, optical coherence tomography system has been extensively studied because it has some advantages such as imaging of high resolution, low cost, and compact size configuration. In order to improve the SNR of OCT system, two types of interferometers were configured and then, we compared simulation with measurement of reference sample. In the OCT system is configured with Michelson interferometer, the contrast of cross-sectional image is reduced with low SNR detection which is due to loss of feedback interference signal from light source part. Also, in order to image measured data with real time, image processing program is constructed. From results of simulation, it is confirmed that improved Michelson interferometer is improved about 10[dB] with a 50 : 50 fiber coupler. And from the measurement of reference sample, about 5[dB] is improved with a 50 : 50 fiber coupler. It is confirmed that the OCT system is configured with the improved Michelson interferometer which has a good distinctive cross-sectional image due to higher contrast.

Establishment of nanometer length standardization using the monolithic x-ray interferometer (일체식 엑스선 간섭계를 이용한 나노미터 표준확립)

  • 김원경;정용환;박진원;김재완;엄천일;권대갑
    • Proceedings of the Korea Crystallographic Association Conference
    • /
    • 2002.11a
    • /
    • pp.35-35
    • /
    • 2002
  • 나노미터 표준을 확립하기 위하여 일체식 엑스선 간섭계에 광간섭계를 결합시킨 복합간섭계를 구성하였다. 복합간섭계는 광간섭계의 Zero crossing 지점부터 표준시편이 올려진 미소이동대의 이동거리를 변화된 위상값으로 읽고 그 변화량을 고분해능 변위 측정기인 엑스선 간섭계로 읽어들이는 구조로 구성된다. 본 연구에서는 미소이동대의 위치 변화와 관련된 광간섭계의 위상 안정도, 엑스선 간섭계 및 미소이동대의 위치 안정도 등이 나노미터 영역의 길이 측정에 매우 중요한 요인이 되므로, 미소이동대의 위치 변화시 정지상태에서의 위상 잠김 (phase locking) 안정도를 측정하였다. 마이켈슨 레이저간섭계의 한쪽 팔을 고정시키고 다른 한 팔은 미소이동대 위에 반사거울을 설치하여 미소이동대의 움직임을 측정하였다. 보다 안정된 위상잠김 상태를 확보하기 위하여 PID feedback loop controller를 사용하였다. 측정 결과 위상 변동폭이 0.022 degree 이하의 높은 위상잠김 안정도를 확보하였으며, 이를 길이단위로 환산하면 정지상태에서 약 0.02 nm 이하의 위치 안정도를 나타낸다.

  • PDF

A Study for Absolutely Distance Measurement System of Wavelength Variable Type by Using Pinciple of the Michelson Interometer (마이켈슨 간섭계의 원리를 이용한 파장변화형 절대 거리측정기의 기초 연구)

  • 김철한;신영록;양윤석;김한근;사공건
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.651-653
    • /
    • 2000
  • In this study, a distance-measurement system was proposed by using principle of the Michelson Interferometer and a fundamental research was carried out. In case of the rnichelson interferometer, relativity distance was measured by relativity-difference of two course of light. But wavelength of light source were changed in this system in order to use interference phenomenon of michelson interferometer in measuring absolutely distance. Wavelength of input signal were changed periodically and were interfered electrically. So absolute distance can be calculated by using $\Delta\lambda$ and measuring $\eta\Delta$ in electric interference. Nose by a external factor was small in this system because a absolutely distance was measured by phase difference. And a dispersion of noise was small in pulse-echo response because a error was occurred in range of phase difference of signal. Also very wide range can be measured by only single system because informations of distance were acquisited in wavelength level.

  • PDF

A study on optical coherence tomography system using optical fiber (광섬유를 이용한 광영상 단층촬영기에 관한연구)

  • 양승국;박양하;장원석;오상기;김현덕;김기문
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2004.04a
    • /
    • pp.5-9
    • /
    • 2004
  • In this paper, we studied the OCT(Optical Coherence Tomography) system which it has been extensively studied because of having some advantages such as high resolution cross-sectional images, low cost, and small size configuration. A basic principle of OCT system is Michelson interferometer. The characteristics of light source determine the resolution and the transmission depth. As a results, the light source have a commercial SLD with a central wavelength of 1,285 nm and FWHM(Full Width at Half Maximum) of 35.3 nm. The optical delay line part is necessary to equal of the optical path length with scattered light or reflected light from sample. In order to equal the optical path length, the stage which is attached to reference mirror is moved linearly by step motor And the interferometer is configured with the Michelson interferometer using single mod fiber, the scanner can be focused of the sample by using the reference arm. Also, the 2-dimensional cross-sectional images were measured with scanning the transverse direction of the sample by using step motor. After detecting the internal signal of lateral direction at a paint of sample, scanner is moved to obtain the cross-sectional image of 2-demensional by using step motor. Photodiode has been used which has high detection sensitivity, excellent noise characteristic, and dynamic range from 800 nm to 1,700 nm. It is detected mixed small signal between noise and interference signal with high frequency After filtering and amplifying this signal, only envelope curve of interference signal is detected. And then, cross-sectional image is shown through converting this signal into digitalized signal using A/D converter. The resolution of the OCT system is about 30$\mu\textrm{m}$ which corresponds to the theoretical resolution. Also, the cross-sectional image of ping-pong ball is measured. The OCT system is configured with Michelson interferometer which has a low contrast because of reducing the power of feedback interference light. Such a problem is overcomed by using the improved inteferometer. Also, in order to obtain the cross-sectional image within a short time, it is necessary to reduce the measurement time for improving the optical delay line.

  • PDF

A Study on the Instrument Measuring Microscopic Movements using a LASER Light Source (레이저 광원을 이용한 극미세 진동 특정장치에 관한 연구)

  • 강성철;지철근
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.8 no.4
    • /
    • pp.17-21
    • /
    • 1994
  • 레이저 광원을 사용하여 정현적으로 극미세 진동하는 압전소자에 부착된 거울을 대상으로 마이켈슨 간섭계로 부터의 간섭신호를 감지해 변위의 크기와 주파수를 측정할 수 있는 진동측정 방법과 장치를 제시한다. 약 80[nm]~1.2[$\mu\textrm{m}$] 범위의 진폭을 가진 물체의 변위와 주파수를 매우 높은 정밀도로 측정하고, 빔의 파장보다 큰 진동물의 간섭신호를 컴퓨터로 처리하여 진동형태의 개형을 구해다.

  • PDF

Development of Optic Balance Using Interference of Light (빛의 간섭 구조를 이용한 광 저울 개발)

  • Choi, Hoon;Park, Kyoung-Su;Lee, Jung-Ryul;Eom, Jin-Seob
    • Journal of Industrial Technology
    • /
    • v.24 no.A
    • /
    • pp.127-131
    • /
    • 2004
  • In this paper, we proposed an optical balance using a Michelson Interferometer structure. The frequency of the interference signal is changed nonlinearly related with a weight to be measured, and this frequency change is processed by a processor to give a measured weight. Several measurements were performed and the good results were obtained with the fluctuation of about 1g.

  • PDF