• Title/Summary/Keyword: 리클로저

Search Result 13, Processing Time 0.028 seconds

A Study on Basic Technology for the Experimental Making of Miniaturized Electrical Power Distribution Line (소형화된 배전선로의 실험적 제작을 위한 기초 연구)

  • Oh, Se-Pil;Choi, Seong-Cheol;Kim, Young-Min;Kang, Ha-Na;Ko, Yun-Seok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.6
    • /
    • pp.1107-1114
    • /
    • 2017
  • In this paper, a miniaturized distribution line was experimentally made. The smart grid distribution system was modeled by analyzing the distribution system, and a miniaturized micro three phase distribution system recloser was designed. The micro recloser was designed as a sensor part, a main part and a relay part, and the main part was designed to cut off the fault current by determining the fault from the input current based on the DSP. Finally, based on the results of the modeling, the micro three phase power distribution line and the micro three phase recloser were experimentally fabricated, and the basic making technology of the miniaturized micro smart grid was obtained through the making process.

Efficient Processing of Transitive Closure Queries in Ontology using Graph Labeling (온톨로지에서의 그래프 레이블링을 이용한 효율적인 트랜지티브 클로저 질의 처리)

  • Kim Jongnam;Jung Junwon;Min Kyeung-Sub;Kim Hyoung-Joo
    • Journal of KIISE:Databases
    • /
    • v.32 no.5
    • /
    • pp.526-535
    • /
    • 2005
  • Ontology is a methodology on describing specific concepts and their relationships, and it is being considered important more and more as semantic web and variety of knowledge management systems are being highlighted. Ontology uses the relationships among concerts to represent some concrete semantics of specific concept. When we want to get some useful information from ontology, we severely have to process the transitive relationships because most of relationships among concepts represent transitivity. Technically, it causes recursive calls to process such transitive closure queries with heavy costs. This paper describes the efficient technique for processing transitive closure queries in ontology. To the purpose of it, we examine some approaches of current systems for transitive closure queries, and propose a technique by graph labeling scheme. Basically, we assume large size of ontology, and then we show that our approach gives relative efficiency in processing of transitive closure, queries.

Development of Overcurrent Relaying IED based on IEC61850 (IEC61850 기반 과전류 계전 IED 개발)

  • Kim, Hae-Nu-Ri;Park, Dong-Ho;Rim, Seong-Jeong;Lee, Seung-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.27-28
    • /
    • 2006
  • 최근 변전소 자동화 시스템에서 가장 큰 관심사는 종래의 인간의 개입을 최소화 할 수 있는 통합화, 자동화, 원격 감시화이다. 즉 변전소를 구성하는 장비들은 서로 다른 구조와 통신방식에서 벗어나 IEC61850 표준규격에서 제안하는 객체 모델링 및 통신프로토콜을 이용한 마이크로프로세서 기반의 IED를 개발하여 상호운용성을 확보하는 것이다. 본 연구에서는 IEC61850기반의 간단한 과전류 계전 IED(OCR)를 개발하고 그 구현방법을 설명하였다. 구현을 위해 상용보드인 MVME5100에 실시간 운영체제인 VxWorks를 포팅하여 MMS(Manufacturing Message Specification), SMV(Sampled multicast value) GOOSE(Generic object oriented substation event) 통신모듈을 탑재하였고 과전류 계전 요소들을 논리장치 및 논리노드로 구현하였다. 또한 전력계통 시뮬레이터인 Hypersim을 이용하여 IEC61850기반의 리클로저, 액츄에이터, 병합장치를 구현하고 과전류 계전 IED의 성능을 검증하였다.

  • PDF

A Study on the Effective Coordination Scheme of Recloser for the Conventional Distribution System Interconnected Dispersed Generation (배전계통에 분산전원 연계시 기존 배전 계통측의 효과적인 리클로저 보호협조 연구)

  • Jung, Seung-Bock;Kim, Jae-Chul;Moon, Jong-Fil;Yun, Sang-Yun;Choi, Joon-Ho;Bae, Joo-Chun
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.533-535
    • /
    • 2002
  • In Korea, power requirement has been increasing. But the large generation unit is hardly installed because of economic and environment problem. Therefore, the concern of dispersed generation system(DGS) is growing. The power distribution system is generally operated with radial type. The protection system is composed of one directive source. But power distribution system inserted DGS changes it to two directive source system. Therefore, the insertion of DGS has the problem of protection coordination. In this paper, we argue fault current affected by interconnected DGS. We analyze fault current flow affected by DGS placement. Then, we find protective coordination problem. Consequently, we study advance point for protection scheme of power system interconnected DGS.

  • PDF

A study of the directional recloser and sectionalizer protective coordination at 22.9[kV] distribution system with new renewable energy generation (신재생에너지원이 연계된 22.9[kV] 배전계통의 양방향 리클로저와 섹셔널라이저 보호협조 방안)

  • Lee, Yeon-Hwa;Choi, Joon-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.525-526
    • /
    • 2007
  • Recently, there has been growing interest in utilizing distributed generation (DG). However, an insertion of DG to existing distribution system can cause several problems such as voltage variations, harmonics, protective coordination, increasing fault current etc,. The typical protection system of the existing distribution system is designed for radial network. But penetration of DG to distribution system changes existing unidirectional power flow to bidirectional power flow. Therefore, investigation to cover whole field of distribution system must be accomplished such as changing of protection devices rating by increasing fault current, reevaluation of protective coordination. This paper presents that PSCAD/EMTDC simulations was accomplished to analyze effect of DG on the distribution protective coordination. In addition, directional recloser-sectionalizer coordination are evaluates distribution system with DG by using PSCAD/EMTDC simulation.

  • PDF

A Study on the Optimal Method for Malfunction of Protection Devices in Distribution Systems Interconnected with Photovoltaic Systems (태양광발전이 연계된 배전계통에서 보호협조기기의 오동작에 대한 최적 방안에 관한 연구)

  • Rho, Dae-Seok;Kim, Chan-Hyeok;Shin, Chang-Hoon;Jeong, Won-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.6
    • /
    • pp.1599-1606
    • /
    • 2008
  • Recently, new dispersed generation systems such as photovoltaic, wind power, fuel cell etc. are energetically interconnected and operated in the distribution systems, as one of the national projects for alternative energy with the provision against oil crisis. The technical guidelines on the interconnection of dispersed generation systems have been established and conducted positively. However, protection devices (Re-closer) in primary feeder of distribution system interconnected with photovoltaic generation may cause problems with mis-operation, and then many customers could have problems like an interruption. So, this paper presents the optimal method to minimize the impact of interruption, using both the symmetric method and MATLAB/SIMULINK. And, also this paper shows the effectiveness of proposed method by simulating at the real distribution systems.

Pimecrolimus ($Elidel^{(R)}$, SDZ ASM1981) (엘리델$^{(R)}$(피메크로리무스)크림 $1\%$ 전임상 약리학 성상 및 피부 선택성)

  • 한국임상약학회
    • Korean Journal of Clinical Pharmacy
    • /
    • v.13 no.2
    • /
    • pp.97-105
    • /
    • 2003
  • 아스코마이신(ascomycin)의 macrolactam 유도체인 피메크로리무스(pimecrolimus; 엘리델 [Elidel], SDZ ASM 981; Novartis Pharma AG, 바젤, 스위스)는 세포선택성을 지닌 염증성 사이토카인(cytokines) 억제제로서 아토피피부염, 알레르기성 접촉피부염, 자극성 접촉피부염 및 판형 건선 등 염증성 피부질환의 치료제로 개발되었다. T세포와 비만세포의 염증성 사이토카인 생산 분비를 억제하고 사전 형성된 염증성 매개물질의 비만 세포 분비를 저해한다. 국소 투여된 피메크로리무스는 알레르기성 접촉피부염(allergic contact dermatitis [ACD]) 돼지 모델에서 고역가 코르티코스테로이드 클로베타졸-17-propionate(corticosteroid clobetasol-17-propionate)와 동등한 효과를 나타낸다. 하지만 피메크로리무스는 클로베타졸과는 달리 피부 위축을 일으키지 않는다. 경구 투여시 피메크로리무스는 마우스와 랫트 ACD 치료에 있어서 타크로림무스(tacrolimus [FK 506])와 동등한 혹은 더 우수한 효과를 나타낸다. 또한 피메크로리무스는 아토피피부염 급성 징후 유사 모델인 저마그네슘 혈증 탈모 랫트(hypomagnesemic hairless rat)의 피부 염증과 소양증을 효과적으로 감소시킨다. 피메크로리무스는 랫트에서 다음과 같은 측면의 전신 면역반응 손상 효과가 타크로리무스 와 비교하여 낮게 평가된다: (1)국소 이식편대 숙주 반응, (2)양(sheep) 적혈구에 대한 항체 형성, (3)신장이식. 시험관내 평가시 돼지 피부를 통한 피메크로리무스 투과 속도가 타크로리무스보다 10배 낮게 측정되므로 생체에서 경피 흡수가 더 적게 될 것으로 판단된다. 상기 자료로 판단컨대 피메크로 리무스는 피부에 대한 항염증 활성이 높을 뿐 아니라 전신 면역반응 손상 부작용이 낮은것으로 사료된다.

  • PDF

Algorithm for stable operation of D/L under connected to distributed generation systems (분산전원 계통 연계시 안정운전을 위한 알고리즘)

  • Kim, Yeong-Min;Kim, Jong-Man;Shin, Baek-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2008.09a
    • /
    • pp.263-265
    • /
    • 2008
  • 분산전원의 배전계통과 연계 시 역 조류, 전압변동, 고조파, 보호협조, 고장전류증가 등의 문제를 일으킬 수 있으므로 배전선로의 안정운전을 위해서는 배전선로의 원활한 보호협조를 통한 적절한 안정운전 방안이 필요하다. 따라서 본 연구에서는 분산형 전원이 연계된 배전계통에서의 리클로저와 변전소 릴레이와의 보호협조 측면에서 악영향을 끼치지 않는 분산형 전원의 연결을 OFFDAS 프로그램에 의하여 검토하여 더 효과적이고 용이한 방법으로 안정 운전할 수 있는 연계방안을 제시하고자 한다.

  • PDF

Reliability Assessment for Distribution System interconnected with New Energy Sources (신재생에너지전원이 도입된 배전계통에서의 신뢰도평가에 관한 연구)

  • Kim, Chan-Hyeok;Rho, Dae-Seok
    • Proceedings of the KAIS Fall Conference
    • /
    • 2007.11a
    • /
    • pp.152-154
    • /
    • 2007
  • 본 논문에서는 기존의 해석적인 수법에서 여러 신뢰도 지표가 주로 수용가의 수와 지형적인 영향만을 고려한 단점을 보완하기 위하여, 어느 특정지역의 수용가가 실제로 정전되는 경우를 상정하여 수용가의 정전비용을 계산하여, 이에 의한 영향을 신뢰도 지표 속에 나타내도록 하였다. 즉, 정전비용에 따른 수용가의 중요도를 고려하기 위하여, 수용가의 정전비용 특성을 이용한 새로운 신뢰도 평가지수를 정의하여, 양적인 면에서 뿐만 아니라 질적인 면에서도 가장 경제적으로 신뢰도를 향상시킬 수 있는 특정 계통이나 지역, 설비 등을 선택할 수 있는 새로운 신뢰도 평가수법을 제안하였다. 또한, 배전계통에 신재생에너지전원(이하 분산형전원)이 도입된 경우를 상정하여 상기의 신뢰도지수를 산정하는 수법을 제안하였으며, 사고구간을 줄이는 리클로우져와 섹셔널라이저의 동작을 포함한 배전계통의 보호협조 시스템도 고려한 신뢰도지수 산정법도 제안하였다.

  • PDF

A Simulation Program for Protection Coordination in the Power Distribution System with Distributed Generators (분산전원 연계 배전계통의 보호협조 정정 프로그램 개발)

  • Kim, Sang-Ok;Seo, In-Yong;Lee, Heung-Ho;Rho, Dae-Seok
    • Journal of the Korea Society for Simulation
    • /
    • v.22 no.1
    • /
    • pp.1-8
    • /
    • 2013
  • A higher penetration of renewable energy sources and adoption of renewable portfolio standard(RPS), the penetration of distributed generators(DGs) into power distribution network is becoming a threat for the safe operation of distribution network. The ground fault current of DGs can cause parasitic trip and mal-trip of protective device in the power distribution network. KEPRI has developed a simulation program for current setting of protective devices in DGs connected distribution network. In this study, we analyzed fault currents of a sample network in two cases, i.e. case 1 is for no DG connection, case 2 for a DG connection. We performed protection coordination for relays installed in the network and analyzed the contribution of a DG.