• Title/Summary/Keyword: 룸

Search Result 445, Processing Time 0.029 seconds

Online face-to-face instructional design model for Software Education using Virtual Classroom (버추얼 클래스룸을 활용한 소프트웨어교육 온라인 대면 교수 설계 모형)

  • Seo, SeongChae;Kim, Chul
    • Journal of The Korean Association of Information Education
    • /
    • v.26 no.1
    • /
    • pp.75-84
    • /
    • 2022
  • Currently, education is being conducted through face-to-face classes and instructional design using blended learning, an integrated online and offline model that utilizes online characteristics. As the paradigm of education has changed from face-to-face classes to non-face-to-face classes since COVID-19, teaching methods to respond to changes are required in the educational field. In this paper, as a instructional design model using online, we proposed a instructional design model that conducts online classes in non-real time and then conducts online face-to-face classes using virtual classrooms in real time. In addition, a teaching strategy that can apply the online face-to-face teaching design model using the proposed virtual class room to software classes was presented. The proposed instructional design model will be able to prepare for a paradigm shift in education with a teaching design that can accommodate the characteristics of face-to-face education online.

Development of virtual reality contents for vocational education Research on Semiconductor production line Clean Room Tour (직업교육을 위한 가상현실 콘텐츠 구현 반도체 생산라인 클린룸 투어 VR 중심으로)

  • Lee, Sun-Min
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.1
    • /
    • pp.191-197
    • /
    • 2023
  • The purpose of the study was to provide an educational environment for designing and producing virtual reality practice contents that can be used in semiconductor production lines and clean rooms. Through this process, the user can acquire practical knowledge through experiences close to reality, such as experiencing the main semiconductor solar cell manufacturing facilities as well as procedural knowledge before and after entering the clean room.. In particular, it provides users with an immersion experience close to reality by creating an environment for experiential content necessary for semiconductor and solar cell manufacturing processes and clean room entrance procedure experiential content, which is expected to improve education immersion, realism, cost, efficiency, and education satisfaction. Depending on the characteristics of Dangerous, Impossible, Counter-productive etc, immersive content makes learners immersed in the learning content, induces proactive/active learning, and embodies the learning content, resulting in positive results in the field of improving educational effectiveness.

Evaluation of Noise Reduction Performance of HVAC System for Ships (선박용 HVAC 시스템의 소음저감성능 평가)

  • Kim, Sang-Ryul;kim, Hyun-Sil;Kim, Jae-Seung;Kim, Bong-Ki;Lee, Sung-Hyun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.8
    • /
    • pp.497-503
    • /
    • 2010
  • In this paper, evaluation of noise reduction performance of HVAC system for ships by means of HVAC mock-up system is presented. Test is done for six different types of HVAC elements including room unit, silencer, etc. It is found that when diameter of silencer is small and air flow is large, flow noise degrades insertion loss. However, as diameter of silencer becomes larger, the effect of flow noise becomes smaller, and insertion loss up to 25 dB is measured. It is observed that insertion loss of diffuser type room unit is usually between zero and 10 dB, whereas that of the nozzle type room unit can be down to - 15 dB. In addition, it is shown that changing duct arrangement can reduce cabin noise by up to 2 dB, and providing same air flow to each room unit is crucial for generating less noise.

HEMP Analysis and Shielding Effectiveness (HEMP 분석과 방호 효율성)

  • Lee, Sun Yui;Kim, Jin Young;Park, Woo Chul
    • Journal of Satellite, Information and Communications
    • /
    • v.8 no.3
    • /
    • pp.20-24
    • /
    • 2013
  • In this paper, we introduce a concept of HEMP systems and analyze a shielding effectiveness by varying placements of the antenna elements. Maxwell's equations for the high frequency of the EMP is represented in the LOS. In order to investigate the effects of electromagnetic attenuations, a shielding room was constructed and employed to obtain measured data. Shielding effects were measured by changing frequency and the distance of receiving antenna. Each measured value was compared to U.S. standard and measuring method was simplified. shielding effects were measured by three different conditions of shielding room. Find the difference between forward measurement and reverse measurement and factors which affects the measurement in shielding room.

Characteristics of Particle Deposition onto the Cleanroom Wall Panel with Electrostatic Voltages (정전압에 따른 클린룸 벽체에서의 입자침착 특성)

  • Noh, Kwang-Chul;Son, Young-Tae;Kim, Jong-Jun;Oh, Myung-Do
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.12
    • /
    • pp.1033-1038
    • /
    • 2006
  • We carried out the experiments on particle deposition onto the cleanroom wall panels. And then we investigated the particle deposition characteristic coefficients for electrostatic voltages and particle size. It was found that there is little difference in characteristics of the particle deposition between the steel panel and the anti-static coating panel. In case of that the particle size is under $1.0{\mu}m$, the particle deposition characteristic coefficient becomes larger as the electrostatic voltage induced to the cleanroom wall panel is increasing. Where in case of that the particle size is over $3.0{\mu}m$, the particle deposition characteristic coefficients do not show any differences with the electrostatic voltages. It is due to that the electrostatic force is the major particle transport mechanism for submicron particles, while the gravitational settling is the major particle transport mechanism for overmicron particles when the electro-static voltages are induced to the cleanroom wall panel.

Experiment for Duct Development to Cool Components in Vehicle Engine Room (차량 엔진룸내 부품 냉각용 덕트 개발을 위한 실험)

  • Lee, Suk Young
    • Journal of Energy Engineering
    • /
    • v.27 no.4
    • /
    • pp.98-102
    • /
    • 2018
  • In order to improve the durability of components in the vehicle engine room, an experiment to improve the air cooling effect of components by installing a cooling duct using intake air aiming at four components, such as generator, battery, ECU and power steel oil, Respectively, experimental results show that the overall component temperature has been reduced, and the reduced temperature difference is in the order of generator, ECU, power steel oil and battery. In order to improve the temperature difference due to these components, it is necessary to optimize the design through the flow analysis in the duct in the future.

An Experimental Study on the Automobile Engine Room Fire Using the Extinguishing Agents (소화약제를 이용한 자동차 엔진룸 화재 실험에 관한 연구)

  • Han, Yong-Taek;Kim, Dong-Ho;Kwon, Sung-Pil
    • Fire Science and Engineering
    • /
    • v.28 no.4
    • /
    • pp.1-7
    • /
    • 2014
  • Several complex devices and equipments are installed in the car's engine room, including various kind of oils or other flammable materials. So re-ignition is very likely to take place in it. In addition, it is restrictive for the driver or the occupant to open the bonnet and to spray the fire extinguisher in the engine room due to the high possibility of explosion. Therefore, a fire extinguishing system, which can detect a fire and inject the fire extinguishing agent to extinguish it, and fire extinguishing agents including HFC-227ea, which can stand the high temperature within the engine room and hold the viscosity sufficient to keep it in the kind of foam, were developed and tested. And the suffocation effect and the cooling effect come from the fire extinguishing principle of the foam fire extinguishing agent and the inhibiter catalyst effect come from the one of HFC-227ea was led simultaneously, and fire extinguishing agents without the secondary damage caused by residuals after the fire extinguishment like a case of the powder fire extinguishing agent, were developed. And experiments using a vehicle collision after the discharge is complete, foreign material can be removed without extinguishing the advantage that experimental results obtained.

New trend of dental education: flipped learning for dental classes using Google classroom platform (치의학 교육의 새로운 트렌드 : 구글 클래스룸을 이용한 플립드 러닝(Flipped learning)의 적용 및 평가)

  • Kong, Jun-Hyeong;Moon, Ho-Jin;Park, Jung-Chul
    • Journal of Digital Contents Society
    • /
    • v.17 no.5
    • /
    • pp.317-327
    • /
    • 2016
  • Flipped learning is a new learning technique which can maximize the learning effect by mixing two or more different learning environments including online & offline, and recently introduced system: 'Google classroom' is the optimized internet platform for flipped learning. This study tried to apply flipped learning to regular course 2nd grade dental students(n=70) and evaluated the satisfaction of students. The subjects of periodontology and operative dentistry were chosen to evaluate flipped learning model for regular course 2nd grade dental students(n=70). Each class consisted of six classes, and three times of them were performed in conventional classes and the other three times were in flipped learning method by using Google classroom. Evaluation of satisfaction progressed at the end of class. In this study, application of flipped learning in the dental college classes showed high efficiency in terms of degree of understanding, self-directed learning and motivation. Collectively, it was shown that flipped learning using Google classroom can be a reliable platform in dental classes.

Analysis of Temperature Distributions in Spray Coating Room (스프레이 코팅 룸의 온도분포 해석)

  • Kim, Nam Woong;Kim, Sung-Yong;Kim, Kug Weon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.11
    • /
    • pp.7667-7671
    • /
    • 2015
  • Recently, Zinc coating is often used with environment friendly features and high performance. Generally The coating temperature is one of main factors for determining coating thickness and coating ability, so the optimal coating temperature is strongly required. In this paper, the thermo-flow simulation considering the air flow inside the coating rooms for analyzing the temperature distributions of Zinc spray coating room was performed. Two spray coating rooms, preheating room and drying room were all modeled by SolidWorks program and the temperature distributions were analyzed by Flow simulation program. The analysis results were verified with the measured data by thermal image camera. The characteristics of temperature distributions of the first spray room and the second spray room were understood and the results showed that the temperatures of two spray coating room were low compared with the target temperature $25^{\circ}C$. To the exclusion of heater addition, the simulation with all the same conditions exclusive the exhaust fan was performed, which showed that the temperatures of the first and the second spray rooms increased by $6.2^{\circ}C$ and $5.8^{\circ}C$. This analysis can be applicable for designing a new spray coating room for improving performance.

A Study on Flow Distribution in a Clean Room with Multiple Exits (다수의 출구를 가지는 크린룸 내부의 기류분포에 관한 연구)

  • Lee, Jae-Heon;Lee, Sie-Un;Kim, Sukhyun
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.17 no.4
    • /
    • pp.418-425
    • /
    • 1988
  • Since conventional computer program is workable only with velocity boundary condition, in practical fluid passage such as clean room which usually have wide inlets and outlets, it is not easy to measure velocity itself because of its vector property. Furthermore a certain assumption of velocity at boundaries may lead to physically unreasonable results. From this motivation, we have developed a computer program to predict whole flow field imposed on pressure-based boundary condition which can be measured by relatively simple method. The only additional velocity boundary condition that should be imposed on to make the problem unique, are no slip condition at all walls and zero cross stream velocity at inlet. The result of present study was compared with that by Bernoulli equation being used practically. They were coincident well each other within 5%, therefore the validity of the present method is proved. In the present work, the flow field in a clean room subject to pressure-based boundary conditions at an inlet and two exits was predicted numerically. The pressure difference between the inlet and the left exit which keeps relatively low pressure among two exits is fixed as 150[Pa] and the pressure at the right exit is varied from zero to 150[Pa] by the increment of 25[Pa]. For each cases the flow characteristics in the clean room, the velocity profile at the inlet, and the flow rate through the two exits was predicted. The flow rate through the right exit imposed on relatively higher pressure than the left exit decreased linearly according to the increase of pressure of the right exit. When the pressure of the right exit is increased enough to cause back flow at the exit, the flow rate is rapidly decreased.

  • PDF