• Title/Summary/Keyword: 로켓 소음

Search Result 37, Processing Time 0.019 seconds

Ground Vibration Test for Korea Sounding Rocket - II PFM (과학로켓 2호(KSR-II) 준비행 모델의 지상 진동 시험)

  • 우성현;김홍배;문상무;이상설;문남진
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.546-551
    • /
    • 2001
  • Space Test Department at KARI(Korea Aerospace Research Institute) plans to carry out the GVT(Ground Vibration Test) for the KSR(Korea Sounding Rocket)-III FM(Flight Model) which is being developed by Space Technology R&D Division. KSR-III will be an intermediate to the launch vehicle capable of carrying satellites to their orbits. GVT offers very important information to predict the behavior of KSR in its operation, and to develop the flight control and aerodynamic analysis. For development of test facilities, testing and analysis methods which can be used for the future test, Space Test Department has performed the GVT with KSR-II PFM(Proto-Flight Model) at Satellite Integration & Test Center of KARl This paper discusses the procedures, techniques and the results of it. In this test, to simulate free-free condition, test object hung in the air by 4 bungee cords specially devised. The GVT was carried out using pure random excitation technique with MIMO(Multi-Input-Multi-Output) method with three electromagnetic shakers, and poly-reference parameter estimation was used to identify the modal parameters. As the result of the test, 11 mode shapes and modal parameters below 200㎐ were identified and compared with analytical results.

  • PDF

A Study on the Nonlinear Behavior of Check Valve System (체크밸브의 비선형거동에 관한 연구)

  • 박철희;홍성철;박창배
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1993.10a
    • /
    • pp.35-41
    • /
    • 1993
  • 산업사회가 발전함에 따라 거대한 플랜트(plant)를 포함하여, 원자력 발전소 와 로켓트 등과 같이 구조적 안전성과 정확한 성능의 확보가 극히 중요시되 는 설비들이 많이 등장하고 있다. 이들 설비를 구성하고 있는 파이프계 (piping system)는 강성 또는 연성재료 및 각종 valve등으로 구성되어 있기 때문에, 고온 고압 고속의 유체가 파이프 내부를 흐를 때 일으키는 진동현상 및 플랜트의 과도운전 상황에서의 일어나는 수격현상(water hammer 또는 steam hammer)과 이로 기인한 제반 진동문제는 안전성확보 측면에서 많은 관심이 고조되고 있다. 이와 관련되어 유체유발진동에 관한 많은 연구들이 수행되었으며, 파이프계에 장착된 밸브에 대한 연구는 Weaver등에 의하여 실험적, 이론적으로 수행되었다. 그들은 유동방정식에서 비정상 베르누이 방 정식을 사용하여 내부유동방정식을 간략하게 유도하였으나, jet flow에 의한 유체의 운동량변화를 고려하지 않고 해석되어 그 결과에 의문이 제기된다. 그러므로 본 연구에서는 체크밸브(check valve)가 부착된 파이프계에서 일어 나는 유체유발진동 및 안정성에 관한 이론적 연구를 수행하여, 파이프계의 설계에 필요한 파라미터의 영향을 파악하고자 한다. 원자력 발전소와 같이 구조적 안정성이 요구되는 플랜트를 국내 기술로 설계 시공하려는 국내 실 정에서 이로 인한 파이프계에 발생할 수 있는 유체유발진동과 안정성을 예 측할 수 있는 해석이론은 파이프계의 설계 및 운전조건의 선정에 있어서 그 의의가 크다고 할 수 있겠다.

  • PDF

LAUNCH ENVIRONMENTAL TEST FOR KITSAT-3 FM (우리별 3호 비행모델에 대한 발사환경시험)

  • 이상현;장영순;배정석;이동우;정연황;성단근
    • Journal of Astronomy and Space Sciences
    • /
    • v.16 no.1
    • /
    • pp.79-88
    • /
    • 1999
  • The satellite experiences the severe launch environment such as vibration, acceleration, shock, and acoustics induced by rocket. Therefore, the satellite should be designed and manufactured to endure such severe launch environments. In this paper, we describe the structure of the KITSAT-3 FM(Flight Model) and the processes and results of the launch environmental test to ensure the reliability during launch period.

  • PDF

Frequency Response of Turbulent Flow to Momentum Forcing in a Channel with Wall Blowing (질량분사가 있는 채널 내부 난류 유동의 외부교란에 대한 주파수 특성)

  • Na, Yang;Lee, Chang-Jin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.1
    • /
    • pp.64-72
    • /
    • 2010
  • Due to the interaction between main oxidizer flow and the wall injected flow resulting from the regression process, a specific time characteristics identified in the frequency spectrum of streamwise velocity is generated in the hybrid rocket motor. In order to understand the response of the turbulent flow to two different types of external momentum forcing, LES analysis was conducted without considering the combustion. It turns out that both concentrated and distributed forcings do not lead to the disastrous resonance phenomenon. Energy contents are enhanced due to the added momentum but the peak frequency was not modified in the turbulent flow near the end of the rocket motor. Natural frequency of the flow system should be taken into account to further pursue the instability issue by using external forcing.

Feasibility Study of a Corrugated Steel Protective Structure for Ammunition Test Facility (탄약시험장의 강재 방호구조물 적용성 분석 연구)

  • Han, Jae Duk;Kim, Donghee;Kim, Sungkon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.5
    • /
    • pp.671-679
    • /
    • 2022
  • Harmful factors such as shock waves and fragments are generated at domestic ammunition testing sites and military shell shooting training sites due to frequent shooting and explosion tests. As a result, complaints from local residents are rapidly increasing, and there is a high risk of damage to facilities and human life. The recently constructed ammunition test site built a test facility for firing artillery and rocket propulsion in a narrow area with a radius of 300 m due to site restrictions, but damage to the facility is accumulating because there is no adequate protective structure. Therefore, in this study, quantitative data on harmful factors such as noise, vibration, shock wave, and thermal effect generated between artillery firing and rocket propulsion tests were measured, and explosion pressure characteristics were analyzed to design a protective structure, and use Autodyn to protect performance. to perform verification.

Ground Vibration Test for Korea Sounding Rocket - III (KSR-III의 전기체 모달 시험)

  • 우성현;김영기;이동우;문남진;김홍배
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.441-447
    • /
    • 2002
  • KSR-III(Korea Sounding Rocket - III), which is being developed by Space Technology R&D Division of KARI(Korea Aerospace Research Institute) will be launched in late 2002. It is a three-stage, liquid propellant rocket which can reach 250 km altitude and will carry out observation of ozone layer and scientific experiments, such as microgravity experiment, and atmospheric measurement. KSR-III is believed to be an intermediate to the launch vehicle capable of carrying a satellite to its orbit. Space Test Department of KARI performed GVT(Ground Vibration Test) fer KSR-III EM at Rocket Test Building of KARI. GVT is very important for predicting the behavior of rocket in its operation, developing flight control program and performing aerodynamic analysis. This paper gives an introduction of rocket GVT configuration and information on test procedures, techniques and results of It. In this test. to simulate free-free condition, test object hung in the air laterally by 4 bungee cords specially devised. For the excitation of test object, pure random signal by two electromagnetic shakers was used and total 22 frequency response functions were achieved. Polyreference parameter estimation was performed to identify the modal parameters with MIMO(Multi-Input-Multi-Output) method. As the result of the test, low frequency mode shapes and modal parameters below 60Hz were identified

  • PDF

A Study of the Comparison Analysis for the Rocket Motor Impulse Noise by the Indoor Sizes (공간크기에 따른 로켓모타 충격소음의 비교분석에 관한 연구)

  • Song, Kee-Hyeok;Chung, Sung-Hak;Kang, WooRam;Lee, DukJu;Park, JongHo
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.3
    • /
    • pp.85-90
    • /
    • 2014
  • The purpose of this study is to analysis the 3 differential size of the interior space for impulse noise. To achieve this goal the 3 kinds (27, 35, $50m^3$) of interior space were performed comparing the impulse noise. Result of this study, the standard error of the mean peak sound pressure of value from 0.19 to 0.27dB and there was no significant difference (p<0.01). And B-duration is significant differences (P<0.01) range from 3.98 to 7.93ms. This is respectively less than 10ms. These findings are confirmed in accordance by the 3 differential space size of the indoor-impulse noise due to 0.3 dB or less, so there was no difference to the operational influence. And also below 100 Hz were found fundamental mode frequency analysis. Results were matched with calculated theoretical values.