• Title/Summary/Keyword: 레이저 스캐닝 미러

Search Result 7, Processing Time 0.022 seconds

Design of 3D Printer Based on SLA Using LSU and Test of Scanning Mechanism (LSU를 이용한 SLA 방식의 3D프린터 설계 및 스캐닝 기구부 동작 테스트)

  • Jang, Min;Oh, Am-Suk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.6
    • /
    • pp.1225-1230
    • /
    • 2017
  • 3D printers have been growing mainly in industrial use, but the recent growth of the personal 3D printer market advanced through economic effects and cost reduction due to technological development. However, current 3D personal printers are very low in customer satisfaction on the limitations of molding speed, size, and precision. In this paper, we propose SLA 3D printer using LSU to overcome the technical limitation of personal 3D printer. In order to verify the operation of the scanning mechanism which is responsible for core functions, the movement of molding board using stepping motor and laser output test was conducted. These tests ensure that the laser was operating and control well was confirmed that a certain point is output to the X-axis by means of a laser module and a polygon mirror. 3D printers which are proposed to improve the accuracy and manufacturing speed is expected to replace the traditional low-budget 3D printer.

The Test of Mechanism Operation for 3D Printer Using Polygon Mirror (폴리곤 미러를 이용한 3D 프린터 기구부 동작 테스트)

  • Kwon, Dong-hyun;Heo, Sung-uk;Lim, Ji-yong;Oh, Am-suk;Kim, Wan-sik
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.735-737
    • /
    • 2016
  • In this paper, we conducted a test of the 3D printer injection method and LSU (Laser Scanning Unit) feature a fusion of the polygon mirror scanning system that is the core mechanism operation for 3D printers for office laser printers SLA system. These tests ensure that the laser was operating and control well was confirmed that a certain point is output to the X-axis by means of a laser module and a polygon mirror. And confirmed after the F-theta lens is incident on the fixed laser power of the beam, and correction according to the correction beam on the mirror reflection was confirmed jineunji the focus according to the Z-axis upper plate.

  • PDF

Fabrication and driving experiment of 2.4mm size mirror for optical pick-up head (광기록 장치의 픽업헤드용 2.4mm 크기의 미러의 제작과 구동실험)

  • Park, Keun-Woo;Kim, Yong-Kweon
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2266-2268
    • /
    • 2000
  • 본 논문에서는 스캐닝 미러의 일종으로, 광저장 장치의 픽업헤드용으로 미세회전을 하면서 레이저 빔을 편향시키는 용도로 사용되는 미러를 제작하고 구동실험을 하였다. 제작된 미러의 크기는 $2400{\times}2400{\times}64{\mu}m^3$이고, 빔 스프링은 $500{\times}9.6{\times}64{\mu}m^3$이다. 니켈 전해 도금으로 29${\mu}m$ 높이의 구동 전극을 제작하였고(세가지 모델: 공기통로가 없는 전극, 공기통로와 간격이 각각 200${\mu}m$인 전극, 공기통로와 간격이 각각 100${\mu}m$인 전극), 미러판과 전극을 조립하여(미러판과 전극 사이의 간격은 각각 29${\mu}m$, 26${\mu}m$, 26${\mu}m$) 구동실험을 하였다. 공진 주파수의 계산간은 576Hz, 측정값은 3개의 미러에서 모두 568Hz이었다. 전극과 미러판의 간격이 최대 접근거리 18${\mu}m$가 되도록 미세 회전을 시켰을 때, 공기통로가 없는 전극에서는 공진 주파수가 524Hz, 공기통로가 200${\mu}m$인 전극에서는 544Hz로 각각 감쇠되었고, 공기통로가 100${\mu}m$인 전극에서는 그대로 568Hz이었다.

  • PDF

Position Control of Laser Scanning Mirror Using Piezoelectric Actuator (압전작동기를 이용한 레이져 스케닝 미러의 위치제어)

  • 지학래;김재환;최승복
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.442-445
    • /
    • 1995
  • This paper presents the position tracking control of a laser scanning mirror system in which piezoelectic actuator is incorporated. Using the shear mode of the piezoelectric actuator,angular oscillation of a laser scanning mirror is derived. Torsion bar is rhen designed and attached to the piezoelctric actuator in order to magnify the amplitude generated by the actuator. Finite element modeling and analysis are essntial for designing the piezoelectic actuator. The torsional resonance mode of the piezoelectric actuator is found from the model analysis of the actuator and the mechanical shear is matched with the driving frequency. Transfer function between the electrical excitation and the mechanical shear deformation at resonance frequency is found form the response of the actuator calculated by the finite element analysis and the governing equation of the system is derived from d'Alembert's principle. Tracking control performance for desired trajectory which is, in fact, sinusoidal curve is presented in order to demonstrate the validity of the proposed system.

  • PDF

A Study on 3D Printer Using Polygon Mirror (폴리곤 미러를 이용한 3D 프린터에 관한 연구)

  • Kwon, Dong-hyun;Heo, Sung-uk;Lim, Ji-yong;Oh, Am-suk;Kim, Wan-sik
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.142-144
    • /
    • 2016
  • Recent promising technologies of the manufacturing sector interest, and the interest in 3D printing that is expected to cause a huge ripple effect rapidly, and various types of products advertised in accordance with the falling price of 3D printers is spreading. However, the personal 3D printers that are currently being advertised is used for Injection output of the simple type that does not require a high processing precision in accordance with the limitation of technical performance, and consumer satisfaction is very low. In this paper, we propose a 3D printer, 3D precision to overcome existing limitations in the way the printer's high SLA 3D printer that combines injection method and the LSU (Laser Scanning Unit) in the office laser printer polygon mirror scanning method. 3D printers which are proposed to improve the accuracy and manufacturing speed is expected to replace the existing entry-level 3D printer.

  • PDF

Nondestructive Diagnosis of NPP Piping System Using Ultrasonic Wave Imaging Technique Based on a Pulsed Laser Scanning System (펄스 레이저 스캐닝 기반 초음파 영상화 기술을 활용한 원전 배관 비파괴 진단)

  • Kim, Hyun-Uk;Lee, Chang-Gil;Park, Seung-Hee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.1
    • /
    • pp.166-173
    • /
    • 2014
  • A noncontact nondestructive testing (NDT) method is proposed to detect the damage of pipeline structures and to identify the location of the damage. To achieve this goal, a scanning laser source actuation technique is utilized to generate a guided wave and scans a specific area to find damage location more precisely. The ND: YAG pulsed laser is used to generate Lamb wave and a piezoelectric sensor is installed to measure the structural responses. The measured responses are analyzed using three dimensional Fourier transformation (3DFT). The damage-sensitive features are extracted by wavenumber filtering based on the 3D FT. Then, flaw imaging techniques of a pipeline structures is conducted using the damage-sensitive features. Finally, the pipes with notches are investigated to verify the effectiveness and the robustness of the proposed NDT approach.

Design of Electromagnetically Driven Micro Scanning Mirror for Laser Animation System (레이저 디스플레이를 위한 전자력 구동 스캐닝 미러의 설계)

  • Lee, Kyoung-Gun;Jang, Yun-Ho;Yoo, Byung-Wook;Jin, Joo-Young;Lim, Yong-Geun;Kim, Yong-Kweon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.3
    • /
    • pp.578-585
    • /
    • 2009
  • In this paper, we present the design of an electromagnetic scanning mirror with torsional springs. The scanning mirror consisting of torsional springs and electromagnetic coils was designed for the applications of laser animation systems. We analyzed and optimized three types of torsional springs, namely, straight beam springs (SBS), classic serpentine springs (CSS), and rotated serpentine springs (RSS). The torsional springs were analyzed in terms of electrical resistance, fabrication error tolerance, and resonance mode separation of each type using analytical formula or numerical analysis. The RSS has advantages over the others as follows: 1) A low resistance of conductors, 2) wide resonance mode separation, 3) strong fabrication error tolerance, 4) a small footprint. The double-layer coils were chosen instead of single-layer coils with respect to electromagnetic forces. It resulted in lower power consumption. The geometry of the scanning mirror was optimized by calculations; RSS turn was 12 and the width of double-layer coil was $100{\mu}m$, respectively. When the static rotational angle is 5 degrees, the power consumption of the mirror plate was calculated to be 9.35 mW since the resistance of the coil part and a current is $122{\Omega}$ and 8.75 mA, respectively. The power consumption of full device including the mirror plate and torsional springs was calculated to be 9.63 mW.