• Title/Summary/Keyword: 레이저 세척

Search Result 11, Processing Time 0.035 seconds

Cleaning of Nip Hard Disk Substrate Using Near-Infrared and Ultraviolet Irradiation of Nd:Yag Laser Pulses (Nd:YAG 레이저의 근적외선과 자외선 펄스를 이용한 NiP 하드디스크 기층의 세척)

  • 김동식
    • Proceedings of the Korean Society of Laser Processing Conference
    • /
    • 2000.11a
    • /
    • pp.23-26
    • /
    • 2000
  • This paper introduces a cleaning process for removing submicron-sized particles from NiP hard disk substrates by the liquid-assisted laser cleaning technique. Measurements of cleaning performance and time-resolved optical diagnostics are performed to analyze the physical mechanism of contaminant removal. The results reveal that nanosecond laser pulses are effective for removing the contaminants regardless of the wavelength and that a thermal mechanism involving explosive vaporization of liquid dominates the cleaning process.

  • PDF

Cleaning of NiP Hard Disk Substrate Using Near-Infrared and Ultraviolet Irradiation of Nd:YAG Laser Pulses (Nd:YAG 레이저의 근적외선과 자외선 펄스를 이용한 NiP 하드디스크 기층의 세척)

  • ;C. P. Grigoropoulos
    • Laser Solutions
    • /
    • v.4 no.2
    • /
    • pp.39-45
    • /
    • 2001
  • This paper introduces a cleaning process for removing submicron-sized particles from NiP hard disk substrates by the liquid-assisted laser cleaning technique. Measurements of cleaning Performance and time-resolved optical diagnostics are Performed to analyze the physical mechanism of contaminant removal. The results reveal that nanosecond laser pulses are effective for removing the contaminants regardless of the wavelength and that a thermal mechanism involving explosive vaporization of liquid dominates the cleaning process.

  • PDF

Role of Liquid Vaporization in Liquid-Assisted Laser Cleaning (액막 보조 레이저 세척에서 액체 기화의 역할)

  • Lee, Joo-Chul;Jang, Deok-Suk;Kim, Dong-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.2
    • /
    • pp.188-196
    • /
    • 2003
  • Liquid-assisted cleaning technology utilizing a nanosecond laser pulse is effective for removing submicron particulates from a variety of solid substrates. In the technique, saturated vapor is condensed on a solid surface to form a thin liquid film and the film is evaporated explosively by laser heating. The present work studies the role of liquid-film evaporation in the cleaning process. First, optical interferometry is employed for in-situ monitoring the displacement of the laser-irradiated sample in the cleaning process. The experiments are performed for estimating the recoil force exerted on the target with and without liquid deposition. Secondly, time-resolved visualization and optical reflectance probing are also conducted for monitoring the phase-change kinetics and plume dynamics in vaporization of thin liquid layers. Discussions are made on the effect of liquid-film thickness and dynamics of plume and acoustic wave. The results confirm that cleaning force is generated when the bubble nuclei initially grow in the strongly superheated liquid.

SEM EVALUATION AND SHEAR BOND STRENGTH OF ER : YAG LASER IRRADIATION ON ENAMEL SURFACE (Er : YAG 레이저 조사가 법랑질 표면 변화와 전단강도에 미치는 영향)

  • Lim, Hyoung-Soo;Lee, Chang-Seop;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.3
    • /
    • pp.374-382
    • /
    • 2001
  • The purpose of this study was to investigate the surface morphology and measure shear bond strength of Er : YAG lased enamel. To determine the most effective energy density of laser for improving bonding strength of human enamel, 24 specimen were lased from 30mJ to 150mJ at 1Hz used focused, defocused beam. After irradiation, the lased specimen were observed scanning electron microscope. To determine the resin shear bond strength of Er : YAG lased enamel, the 90 specimen were divided into 3 groups. The Control group was etched with 37% phosphoric acid for 15seconds and rinsed. Group 1 was only laser irradiaton(60mJ, 10Hz), Group 2 was irradiated as Group 1 regimen, followed 37% phosphoric acid etching. The following results were obtained: 1. In both focused and defocused Er : YAG lased enamel surface are similar to acid-etched enamel more than 60mJ in SEM evaluation. 2. The more increased laser energy, the more observed fissuring surface. 3. The highest mean shear bond strength value was observed in control group with the statistical significance(p<0.05) between all the other groups and the shear bond strength in group 1 was the lowest with significant difference among the other groups.

  • PDF

Conservation of Removing Surface Contaminants on Silla monument at Jungsung-ri using Nd:YAG Laser Cleaning System (Nd/YAG레이저를 이용한 포항중성리신라비 표면오염물 제거와 보존처리)

  • Lee, Tae Jong;Kim, Sa Dug;Lee, Joo Wan;Oh, Jung Hyeon;Lee, Myeong Seong
    • Korean Journal of Heritage: History & Science
    • /
    • v.44 no.4
    • /
    • pp.142-153
    • /
    • 2011
  • 'Silla Monument Stone in Jungseong-ri, Pohang' was discovered in Pohang City, Gyeongsangbuk Province of Korea in 2009. The monument stone with irregular shape has dimensions of maximum height of 105cm, width of 47.6~49.6cm, thickness of 13.8~14.7cm and weight of 115kg. The results of monument stone was found to be granitite. Conservation treatment procedure was carried out in the order of production of Weathering map, cleaning of surface pollutants, consolidation using ethyl silicate. Black pollutant(crust) that covered more than 60% of the surface was analyzed first in order to remove the pollutants on the surface of the monumental stone by cleaning of surface pollutants using laser. The purpose on analysis was not only to verify the pollutants on the stone but also to carry out preliminary cleaning by securing rocks with same pollutant as the monumental stone. As the results of analysis using p-XRF(PMI. INNOV-X, USA) on the site, high level of Mn and Fe were detected, and the analysis of small section that had been fallen off with SEM/EDX for the purpose of quantitative analysis also detected high level of Mn. The Similar contaminants on Stone secured in the manner described above were made into 10 samples ($5cm{\times}5cm$) and was subjected to preliminary cleaning by Nd-YAG Laser(Laser&Physics, Korea). The results of surface observation through portable microscope during cleaning revealed that the power of 460mJ, wavelength of 1064nm and irradiation frequency of 1,800~2,300 per $25cm^2$ were most effective. Evaluation on the preservative treatment was made through confirmation of the extent of removal through color-difference meter measurement and component analysis prior to and following removal of the pollutants. As the result of color-difference meter measurement increase in the brightness was evidenced by the increase in the brightness ($L^*$)value from 33 to 49, and it was possible to ascertain the reduction in the pollutants as the content of Mn was reduced by about 80% from $50,000{\pm}5,000ppm$ to $10,000{\pm}2,000pmm$ from the result of component analysis.

EFFECT OF ETCHING TIME ON ENAMEL SURFACE ROUGHNESS: CONFOCAL LASER SCANNING MICROSCOPIC STUDY (공초점 레이저주사현미경을 이용한 산부식 시간에 따른 법랑질 표면 양상에 관한 연구)

  • Kam, Dong-Hoon;Kim, Jung-Wook;Jang, Ki-Taeg;Lee, Sang-Hoon;Kim, Chong-Chul;Hahn, Se-Hyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.1
    • /
    • pp.41-46
    • /
    • 2003
  • In order to evaluate the sufficient etching time for successful bonding and also minimizing unnecessary mineral loss, the enamel surface roughness analysis was performed using confocal laser scanning microscopy. Sixty extracted sound human molar teeth were imbedded in the center of acrylic cylinder using self-curing clear resin exposing buccal surface, and then polished with series of SiC paper(220, 500, 800, 1000, 2000, 4000 grit). Each specimen was randomly assigned to six groups(N=10). 37% phosphoric acid was applied to the polished tooth surface for 10, 20, 30, 40, 50, 60 seconds respectively and washed with copious water. After the surface roughness analysis, five roughness parameters(Sa, Sq, Sz, Sdr, Ra) were statistically analysed by ANOVA and Duncan post hoc test. We found that the all five parameters had higher roughness value in 30 seconds etching time, especially parameter Sz showed the lowest value in 10 seconds etching time and the highest value in 30 seconds etching time compared with the other etching times(p<0.05).

  • PDF

Evaluation of titanium surface properties by $Nd:YVO_4$ laser irradiation: pilot study ($Nd:YVO_4$ 레이저 조사에 따른 티타늄의 표면특성 평가: 예비 연구)

  • Kim, Ae-Ra;Park, Ji-Yoon;Kim, Yeon;Jun, Sei-Won;Seo, Yoon-Jeong;Park, Sang-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.3
    • /
    • pp.167-174
    • /
    • 2013
  • Purpose: This study was conducted to evaluate the roughness and surface alternations of three differently blasted titanium discs treated by $Nd:YVO_4$ Laser irradiation in different conditions. Materials and methods: Thirty commercially pure titanium discs were prepared and divided into three groups. Each group was consisted of 10 samples and blasted by $ZrO_2$ (zirconium dioxide), $Al_2O_3$ (aluminum oxide), and RBM (resorbable blasted media). All the samples were degreased by ultrasonic cleaner afterward. Nine different conditions were established by changing scanning speed (100, 300, 500 mm/s) and repetition rate (5, 15, 35 kHz) of $Nd:YVO_4$ Laser (Laser Pro D-20, Laserval $Korea^{(R)}$, Seoul, South Korea). After laser irradiation, a scanning electron microscope, X-ray diffraction analysis, energy dispersive X-ray spectroscopic analysis, and surface roughness analysis were used to assess the roughness and surface alternations of the samples. Results: According to a scanning electron microscope (SEM), titanium discs treated with laser irradiation showed characteristic patterns in contrast to the control which showed irregular patterns. According to the X-ray diffraction analysis, only $Al_2O_3$ group showed its own peak. The oxidation tendency and surface roughness of titanium were similar to the control in the energy dispersive X-ray spectroscopic analysis. The surface roughness was inversely proportional to the scanning speed, whereas proportional to the repetition rate of $Nd:YVO_4$. Conclusion: The surface microstructures and roughness of the test discs were modified by the radiation of $Nd:YVO_4$ laser. Therefore, laser irradiation could be considered one of the methods to modify implant surfaces for the enhancement of osseointegration.

AN EVALUATION OF CHEMICAL DEGRADATION OF LIGHT-CURED RESTORATIVE COMPOSITES (광중합 복합레진의 화학적 분해 평가)

  • Yang, Kuy-Ho;Kim, Hun-Ju;Choi, Nam-Ki
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.3
    • /
    • pp.530-539
    • /
    • 2003
  • The aim of this study was to evaluate the resistance to degradation of four commercial composite resins in an alkaline solution. The brands studied were Charisma, Filtek P 60, Palpique Estelite, and Spectrum. Preweighed discs of each brand were exposed to 0.1N NaOH solution at $60^{\circ}C$. After 2 weeks they were removed, neutralized with HCl, washed with water and dried. Resistance to degradation was evaluated on the basis of following parameters: (a) mass loss(%) - determined from pre-and post-exposed specimen weights; (b) Si loss(ppm) - obtained from ICP-AE analysis of solution exposed to specimens; and (c) degradation depth(${\mu}m$) - measured SEM and CLSM from polished circular sections of exposed specimens. The results were as follows: 1. The sequence of mass loss was in descending order by Palpique Estelite, Filtek P 60, Charisma, and Spectrum. 2. The sequence of the degree of degradation layer depth was in descending order by Filtek P 60, Charisma, Palpique Estelita, and Spectrum. 3. The sequence of the Si loss was in descending order by Chrisma, Spectrum, Palpique Estelite, and Filtek P 60. 4. The correlation coefficient between mass loss and degradation layer depth was relatively high(r=0.704, p<0.05). 5. When observed with SEM, destruction of bonding was observed between resin matrix and filler. 6. When observed with CLSM, degradation layer depth of composite resin surface was observed.

  • PDF

Analysis of Hydraulic Characteristics According to Operation of Movable Weir (가동보 운영에 따른 수리학적 특성 분석)

  • Seo, Il Won;Park, Sung Won;Kim, Tae-Won
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.101-101
    • /
    • 2011
  • 현재 국내에서 시행되고 있는 '4대강 살리기 사업'은 하천에서 발생하는 홍수 및 가뭄재해방지를 위한 다양한 공학적 노력을 시도하고 있다. 특히 안정적인 수위 및 유량확보와 홍수방지를 위한 보(weir)가 4대강 유역에 16개 설치되고 있다. 이러한 보 구간에는 고정보와 가동보가 복합적으로 설치되고 있으며 가동보는 그 형상과 운영방식에 따라 다양한 설계방안이 적용되었다. '4대강 살리기 사업' 중 낙동강 23공구의 강정보 공사 구간에는 원호형태의 측면 형상을 갖는 라이징 섹터게이트(Rising sector gate)가 적용되었다. 라이징 섹터게이트는 구조물의 높이가 낮고 수문의 개폐장치가 수문피어 구조물 내에 설치되어 경관이 우수하며, 구조가 간단하여 비체와 수류의 안정성이 뛰어나기 때문에 4개의 공사구간에 적용되었다. 따라서 본 연구에서는 강정보의 가동보 구간 2문 중 1문을 1/100 축척으로 제작하여 가변경사 개수로에 설치하고, 홍수 빈도별 상류 유량 조건과 하류단 수위조건으로 케이스를 정하여 실험을 수행하였다. 본 실험에서 사용한 개수로 장치는 너비 0.6 m, 높이 0.8 m, 그리고 길이 15.0 m(측정가능 구간, 헤드탱크와 테일게이트 부제외)의 개수로 실험장치이다. 측부는 모두 강화유리로 되어 육안관찰 및 계측 시 용이하게 제작되었으며, 순환식 유량 공급장치를 구축하여 수로의 하부에 설치된 유량탱크로부터 계속적으로 순환하도록 설계되었다. 또한 수로 하단으로부터 상단방향으로 약 33 m 지점에 전동 유압식 Jack screw 2기가 설치되어 경사도를 조절할 수 있도록 제작되었다. 유량조절용 판넬의 제어기판에는 디지털 경사계가 설치되어 있기 때문에 보다 정확한 경사도의 조절이 가능하다. 보 모형의 총연장은 53 cm이며 폭은 45 cm이다. 섹터게이트의 게이트부분은 직경 15 cm로 설계하였다. 문주부분을 포함한 모든 모형은 아크릴로 제작하며 레이저의 주사를 방해하지 않으며 투과율을 최대로 할 수 있도록 고강도의 아크릴을 가장 얇게 하여 중공형태를 채택하였다. 실험조건은 우선 보의 운영방안에 따라 게이트의 4가지 개방도를 설정하였고, 특히 평수위조건에서는 보의 상류부에 퇴적된 퇴적물의 세척을 위한 flushing 운영개방도 포함되어 있다. 홍수시에 대한 유량조건은 2년 빈도에 해당하는 유량을 수문의 비율과 상사법칙에 따라 설정하였으며 하류단 수위조건도 동일한 조건에 대한 값을 채택하여 적용하였다. 유동장의 해석을 위해서는 비접촉식 계측방법인 PIV(Particle Image Velocimetry) 시스템을 채택하여 2차원(x-z 방향) laser sheet를 생성하고 주입된 particle에서 반사된 변위(displacement) 정보를 상호상관(cross-correlation)기법으로 유동장을 계산하였다. 또한 수리모형과 동일한 지형격자를 구축하여 3차원 CFD 프로그램인 FLOW-3D로 계산하여 결과를 비교하였다. 특히 flushing 운영방안에 대한 게이트부의 개방도를 세가지(30, 45, $60^{\circ}$)로 구분하여 모의하였고, 적절한 개방도를 제안하고자 하였다. 실험결과는 우선 4가지 운영방안에 대한 가동보 주변에서의 유속장을 파악하였고, 최대유속의 발생위치의 변화를 확인할 수 있었다. 그리고 이에 따른 보의 바닥에서 최대유속이 발생할 경우, 하상보호공 위치와 거리 등에 대해서 분석하였다. 이를 통해 가동보 운영에 따른 다양한 유속구조를 파악할 수 있게 되며 구조적 안정성 확보를 위한 검증자료로 활용될 수 있을 것으로 예상된다. 향후, 가동보 운영방안 중 수세효과(flushing effect)에 대한 효과분석을 위해 게이트부 상류구간에 적절한 입경과 비중의 퇴적물질을 설치하는 연구와 상류부에서의 유입유사농도 및 시간변화에 따른 퇴적에 관한 연구를 수행할 계획이다.

  • PDF

HISTOLOGIC FEATURE AND INFILTRATION OF ADHESIVE RESIN ACCORDING TO PRETREATMENT ON PROXIMAL EARLY CARIES LESION (평활면 초기 우식병소의 표면처리에 따른 조직상 및 접착제의 침투 양상 비교)

  • Kim, In-Young;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.1
    • /
    • pp.30-37
    • /
    • 2009
  • Early enamel caries is commonly remineralized by the patient‘s improved oral hygiene or fluoridation, however the result is clinically unreliable. As an alternative, we tried to seal the lesions with low-viscosity light-curing resin. The aim of the present study was to search the proper methods of the adequate pretreatment prior to applying adhesive resin on natural proximal caries lesions. Thirty nine extracted deciduous molar teeth showing proximal early caries lesion were used for this study. They were divided into 5 groups : Group 1; only carefully cleaned with water, group 2; etched with 15% HCl for 15s, group 3; etched with 35% phosphoric acid for 15s, group 4; etched with 35% phosphoric acid for 30s, and group 5; cleaned with 0.5% NaOCl. Following results were obtained by evaluating with SEM and CLSM after applied with adhesive resin. 1. As a result of SEM evaluation, group 2 showed clearly removed surface layer, group 3,4 showed partially removed surface layer irregularly, group 5 showed slightly removed surface layer. 2. Group 2 showed the deepest infiltration depth, followed by group 4, group 3, group 5, group 1 and besides group 5, other groups showed significantly deep infiltration depth. (p < 0.01) In conclusion, the best methods of the adequate pretreatment on natural proximal caries lesion for deep infiltration of adhesive resin was to etch with 15% HCl for 15s.

  • PDF