• Title/Summary/Keyword: 레이저 반사법

Search Result 56, Processing Time 0.026 seconds

Optical Analysis for the Estimation of Whole Blood Coagulation Time with Magnetic Particles (자성 철 가루를 이용한 혈액 응고시간 측정법의 광학적 해석)

  • Lee, Jaehyun;Choi, Hyoungsoon;Jang, Dongwoo;Nahm, Kie B.
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.6
    • /
    • pp.338-341
    • /
    • 2013
  • Prothrombin Time (PT) is used as a measure of blood coagulation time. An optical analysis of the signal generating mechanism is described here for the reflection-type arrangement. Thromboplastin added into serum or whole blood initiates the coagulation process. We added a sufficient amount of magnetic particles into the sample before adding thromboplastin and subjected the mixture to a rotating magnetic field. The laser light gets reflected in a periodically modulated fashion with respect to the magnetic field rotation. Analysis of this decaying modulation could produce a reasonable coagulation time. We also introduce a simulation model to explain the signal generating mechanism using LightTools.$^{TM}$

Noncontact 3-dimensional measurement using He-Ne laser and CCD camera (He-Ne 레이저와 CCD 카메라를 이용한 비접촉 3차원 측정)

  • Kim, Bong-chae;Jeon, Byung-cheol;Kim, Jae-do
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.11
    • /
    • pp.1862-1870
    • /
    • 1997
  • A fast and precise technique to measure 3-dimensional coordinates of an object is proposed. It is essential to take the 3-dimensional measurements of the object in design and inspection. Using this developed system a surface model of a complex shape can be constructed. 3-dimensional world coordinates are projected onto a camera plane by the perspective transformation, which plays an important role in this measurement system. According to the shape of the object two measuring methods are proposed. One is rotation of an object and the other is translation of measuring unit. Measuring speed depending on image processing time is obtained as 200 points per second. Measurement resolution i sexperimented by two parameters among others; the angle between the laser beam plane and the camera, and the distance between the camera and the object. As a result of these experiments, it was found that measurement resolution ranges from 0.3mm to 1.0mm. This constructed surface model could be used in manufacturing tools such as rapid prototyping machine.

Role of Liquid Vaporization in Liquid-Assisted Laser Cleaning (액막 보조 레이저 세척에서 액체 기화의 역할)

  • Lee, Joo-Chul;Jang, Deok-Suk;Kim, Dong-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.2
    • /
    • pp.188-196
    • /
    • 2003
  • Liquid-assisted cleaning technology utilizing a nanosecond laser pulse is effective for removing submicron particulates from a variety of solid substrates. In the technique, saturated vapor is condensed on a solid surface to form a thin liquid film and the film is evaporated explosively by laser heating. The present work studies the role of liquid-film evaporation in the cleaning process. First, optical interferometry is employed for in-situ monitoring the displacement of the laser-irradiated sample in the cleaning process. The experiments are performed for estimating the recoil force exerted on the target with and without liquid deposition. Secondly, time-resolved visualization and optical reflectance probing are also conducted for monitoring the phase-change kinetics and plume dynamics in vaporization of thin liquid layers. Discussions are made on the effect of liquid-film thickness and dynamics of plume and acoustic wave. The results confirm that cleaning force is generated when the bubble nuclei initially grow in the strongly superheated liquid.

Simulations for Internal Defect Inspection Using Laser Generated Ultrasonic Wave in Ablation Regime (어블레이션 영역 레이저 초음파의 시뮬레이션과 내부결함 검사)

  • Kim, Jin-Gyum;Choi, Sungho;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.3
    • /
    • pp.226-232
    • /
    • 2014
  • In the present study, the characteristics of laser ultrasound in the ablation regime are investigated using simulations and experiments. The laser ultrasonic technique has been recognized as a noncontact method in the field of nondestructive tests (NDTs). In hostile environments (such as hot temperatures), this method has various advantages over the conventional contact ultrasonic method. In particular, in the ablation regime, the laser ultrasonic technique is suitable for inspecting internal defects because of the high amplitude and directivity of the longitudinal wave. In this paper, a simulation model for laser ultrasound in the ablation regime was developed. This model was subsequently applied to a defective specimen using the B-scan method to locate defects. Finally, we performed an experimental test to verify the simulation results. Consequently, the simulation demonstrated good agreement with the experimental test.

Damage Measurement for Molybdenum Thin Film Using Reflection-Type Digital Holography (반사형 디지털 홀로그래피를 이용한 Molybdenum 박막의 손상 측정)

  • Kim, Kyeong-Suk;Jung, Hyun-Il;Shin, Ju-Yeop;Ma, Hye-Joon;Kwon, Ik-Hwan;Yang, Seung-Pill;Hong, Chung-Ki;Jung, Hyun-Chul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.2
    • /
    • pp.141-149
    • /
    • 2015
  • In the fabrication of electronic circuits used in electronic products, molybdenum thin films are deposited on semiconductors to prevent oxidation. During the deposition, the presence of a particle or dust at the interface between the thin film and substrate causes the decrease of adhesion, performance, and life cycle. In this study, a damage measurement targeting two kinds of glass substrate, with and without particles, was performed in order to measure the change in the molybdenum thin film deposition area in the presence of a particle. Clean and dirty molybdenum thin film specimens were fabricated and directly deposited on a substrate using the sputtering method, and a reflection-type digital holographic interferometer was configured for measuring the damage. Reflection-type digital holography has several advantages; e.g., the configuration of the interferometer is simple, the measurement range can be varied depending on the magnification of a microscopic lens, and the measuring time is short. The results confirm that reflection-type digital holography is useful for the measurement of the damage and defects of thin films.

Measurement of oxygen isotope ratio using tunable diode laser absorption spectroscopy (다이오드 레이저 흡수분광법을 이용한 산소 동위원소의 성분비 측정)

  • Park, Sang-Eon;Jung, Do-Young;Kim, Jae-Woo;Ko, Kwang-Hoon;Im, Kwon;Jung, Eui-Chang;Kim, Chul-Joong
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.1
    • /
    • pp.1-5
    • /
    • 2004
  • Tunable diode laser absorption spectroscopy was performed for analysis of the H$_2$$^{18}$ O/H$_2$$^{16}$ O isotope ratio of a water sample which was enriched by the membrane distillation method. In order to improve the signal-to-noise ratio, the wavelength modulation spectroscopic method was used with a lock-in amplifier. The fringe noise could be suppressed by using the FFT (Fast Fourier Transform) lowpass filter and the optimization of the modulation depth of the laser frequency. The maximum deviation of $\delta$-value was measured to be$\pm$4$\textperthousand$.

Development of a Surface Roughness Measurement Method Using Reflected Laser Beam Image and Its Application (레이저광 반사 화상을 이용한 표면 거칠기 측정법의 개발과 적용)

  • Yun, Yun-Feng-Shen;Kim, haa-young;An, jung-hwan;Chi, ei-jon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.11
    • /
    • pp.51-57
    • /
    • 2001
  • A light beam reflected from a machined surface generally containes information concerning about its surface roughness. This study examines and proposes a surface roughness measurement technique for on-machine measurement of machined surfaces. The technique is based on the measurement of a reflected laser beam pattern and the statistical analysis of its light intensity distribution. The surface roughness was found to be closely related to the standard deviation of the light intensity on the primary axis of the reflected pattern. An image acquisition device is made up of a laser diode, a half mirror, a screen, and a CCD camera. The exact image with the primary and secondary axes of a reflected laser beam pattern is calculated through such image processing algorithm as thresholding, edge detection, image rotation, segmentation, etc. A median filter and a surrounding light correction algorithm are improve the image quality and reduce the measuring error. Using the developed measuring device the effect of screen materials and workpiece and workpiece materials was investigated. Experimental results regarding to relatively high-quality surfaces machined by grinding, polishing, lapping processes have shown the measurement error is within 10% in the range of $0.1{mu}m~0.8{\mu}m R_q.$Therefore, the proposed method is thought to be effectively used when quick measurements is needed with workpieces fixed on the machine.

  • PDF

Long-term stabilization of optical feedback of a resonant external cavity coupled semiconductor laser (공진형 외부 캐비티 부착 반도체 레이저의 광피드백 장기 안정화)

  • 신철호
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.2
    • /
    • pp.96-99
    • /
    • 1998
  • In this study, a novel long term stabilization method of optical feedback for the resonant cavity coupled semiconductor lasers is proposed, and its utility was shown experimentally. The proposed method is realized by using the pahse discriminator of optical feedback with high gain. The phase discriminating signal was obtained by the polarization spectroscopic technique using reflection light from the external reflector, which is a confocal Fabry-Perot cavity. Experimental result shows that stable control state can be maintained up to 20 hours. The period can be increased by reducing size of the system and/or fixing position stably of optical parts used, which were arranged on an optical table by using magnetic bases in this experiment. The proposed long-term stabilization method of optical feedack of a resonant external cavity coupled semiconductor laser is very useful for the field of high sensitivity measurement, and for the use in the laboratory level in particular.

  • PDF

Analysis of Nanosecond Explosive Vaporization Process by Photothermal/Photoacoustic Methods (광열/광음 기법에 의한 나노초 폭발적 기화 과정 분석)

  • Park, Hee-K.;Grigoropoulos, Costas P.;Choi, Sun R.;Kim, Dong-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.6
    • /
    • pp.804-812
    • /
    • 2003
  • This paper introduces optical methods for in-situ measurement of surface temperature and pressure transient in thermal processes having nanosecond time scales. In the temperature measurement, a p -Si thin film whose refractive index is calibrated as a function of temperature is embedded beneath the sample surface and the photothermal reflectance is monitored for estimating the surface temperature. The pressure transients are measured using the photoacoustic optical deflection method. The experimental technique is used to analyze the nanosecond laser induced vaporization process that is central to numerous engineering and bio-medical applications. Based on the experimental results, discussions are made on the experimental technique and the physical mechanisms of laser-driven explosive vaporization phenomena.

나노입자와 표면증강라만분광학 (Surface Enhanced Raman Scattering: SIRS)을 활용한 탄소재료, 고분자 자기조립박막 및 생체분자 연구

  • 주상우
    • Polymer Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.228-233
    • /
    • 2004
  • 본 기고부분에서는 레이저 라만 분광법을 이용하여 나노입자에 흡착된 자기조립박막의 구조를 밝히고 응용성을 모색하는 일을 소개하고자 한다 Au 나노입자는 최근 재료과학과 의학 및 생물학에서 그 쓰임의 폭이 넓어지고 있다. 나노입자가 처음 사용된 예들 중에 가장 잘 알려진 것은 고대 로마 시대의 Lycurgus 컵에 기인한다고 한다. 컵 안에 함유된 미량의 은이나 금 나노입자에 의해서 반사했을 때와 투과할 때의 빛깔이 다르게 보이며 이러한 성질은 중세건축물의 스탠드 글라스에 이용되어 왔다. 근대적인 의미에서 Au 콜로이드의 수용액이 작은 미세입자가 분산되어 있다고 생각한 사람은 전기화학의 창시자라 할 수 있는 영국의 Faraday라 할 수 있다.(중략)

  • PDF