• Title/Summary/Keyword: 레이저 반사법

Search Result 56, Processing Time 0.024 seconds

Laser Speckle Imaging Using Adaptive Windowing Method (적응 윈도우 기법을 사용한 레이저 스펙클 영상의 처리)

  • Jin, Ho-Young;Shin, Hyun-Chool
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.47 no.1
    • /
    • pp.97-102
    • /
    • 2010
  • A laser speckle is a random pattern that has a granular appearance produced by reflected light when a coherent laser illuminates an irregular course surface. Most important property of laser speckle is detecting micro-vascular. Speckle image needs image processing to detect micro-vascular. This paper proposes a new image processing method for laser speckle, adaptive window method that adaptively processes laser speckle images in the spatial. Conventional fixed window based LASCA has shortcoming in that it uses the same window size regardless of target areas. Inherently laser speckle contains undesired noise. Thus a large window is helpful for removing the noise but it results in low resolution of image. Otherwise a small window may detect micro vascular but it has limits in noise removal. To overcome this trade-off, we newly introduce the concept of adaptive window method to conventional laser speckle image analysis. We have compared conventional LASCA and its variants with the proposed method in terms of image quality and processing complexity.

Optical bistability in the Fabry-Perot etalon which contains $As_2S_3$ space layer (비정질 $As_2S_3$를 중간층으로 Fabry-Perot 에탈론에서의 광쌍안정에 관한 연구)

  • 김강호;김석원;한성홍
    • Korean Journal of Optics and Photonics
    • /
    • v.8 no.6
    • /
    • pp.466-470
    • /
    • 1997
  • We fabricated the asymmetric Fabry-Perot etalon which contains amorphous $As_2S_3$ as a spacer layer by using the method of optical multilayer coating and observed the optical bistability with the polarization. Optical thickness of the spacer layer is 2$\lambda$ at $Ar^+$ ($\lambda $=514.5 nm) laser wavelength. Optical bistability was observed at the intensities between 80~100 mW and the experiment shows us that the trends of bistable loop of the reflected and the transmitted lights are quite different depending on the state of polarization. This phenomena can be explained as the phase differences of each polarizations are different in the nonlinear Fabry-Perot etalon.

  • PDF

Three-dimensional Geometrical Scanning System Using Two Line Lasers (2-라인 레이저를 사용한 3차원 형상 복원기술 개발)

  • Heo, Sang-Hu;Lee, Chung Ghiu
    • Korean Journal of Optics and Photonics
    • /
    • v.27 no.5
    • /
    • pp.165-173
    • /
    • 2016
  • In this paper, we propose a three-dimensional (3D) scanning system based on two line lasers. This system uses two line lasers with different wavelengths as light sources. 532-nm and 630-nm line lasers can compensate for missing scan data generated by geometrical occlusion. It also can classify two laser planes by using the red and green channels. For automatic registration of scanning data, we control a stepping motor and divide the motor's rotational degree of freedom into micro-steps. To this end, we design a control printed circuit board for the laser and stepping motor, and use an image processing board. To compute a 3D point cloud, we obtain 200 and 400 images with laser lines and segment lines on the images at different degrees of rotation. The segmented lines are thinned for one-to-one matching of an image pixel with a 3D point.

Mid-infrared Cavity Ringdown Spectrometer Using Difference - frequency Generation (차주파수 생성을 이용한 중적외선 공동 광자감쇠 분광장치)

  • 이동훈;윤일선;이용훈;김봉수
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.02a
    • /
    • pp.204-205
    • /
    • 2003
  • 미량기체의 흡수스펙트럼을 높은 감도로 측정하는 공동 광자감쇠 분광법(cavity ringdown spectroscopy; CRDS)을 나노초 레이저 펄스의 차주파수 생성(difference-frequency generation; DFG)을 광원으로 이용하여 파장 3 ~ 4 $\mu\textrm{m}$ 영역에서 구현하였다. CRDS는 고반사율 거울로 이루어진 광학적 공동에 단일 파장의 빛을 가두었다가 그 에너지의 시간적 감소율을 측정하여 공동 속 기체의 흡수율을 알아내는 방법이다. (중략)

  • PDF

Mode Behavior of Circular Vertical-Cavity Surface-Emitting Laser (원형 수직 캐비티 표면 광방출 레이저의 모드특성)

  • Ho, Kwang-Chun
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.1
    • /
    • pp.51-56
    • /
    • 2012
  • The resonance properties of circular vertical-cavity surface-emitting lasers (VCSELs) are studied by using a newly developed equivalent network approach. Optical parameters, such as the stop-band or the reflectivity of periodic Bragg mirrors and the resonance wavelength, are explored for the design of these structures. To evaluate the differential quantum efficiency and the threshold current density, a transverse resonance condition of circular modal transmission-line theory is also utilized. This approach dramatically reduces the computational time as well as gives an explicit insight to explore the optical characteristics of circular VCSELs.

DEVELOPMENT OF HIGH SENSITIVE MODEL OF CARIES ACTIVITY TEST FOR EARLY DIAGNOSIS OF DENTAL CARIES (치아우식증의 조기진단을 위한 고감도 우식활성검사 모형개발)

  • Lee, Sang-Ho;Lee, Chang-Seop
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.1
    • /
    • pp.169-179
    • /
    • 2000
  • The purpose of this study is to develop the system which convert the optical difference of teeth texture between intact enamel and incipient caries lesion into shade difference by laser fluorescence and to develop new and simple caries activity test using laser fluorescence. The experimental design of this study consists of three parts. In first part, a new method for the in vitro assessment of changes in initial enamel caries lesion of Bovine teeth using laser fluorescence is tested. In second part, in vivo assessment undertaken. Number of teeth which showed incipient carious lesion on buccal surface examined by laser fluorescence was compared with the caries activity test of $Cariescreen^{(R)}$ test and other oral environmental test of dDfFtT. In third part, new caries activity test measured by laser fluorescence was developed on the basis of above results and evaluated the sensitivity, specificity, and diagnostic power. Optical density measured by laser fluorescence was increased as increasing the depth of incipient carious lesion and showed high correlation$(\gamma=0.7015)$ with lesion depth. Optical density showed direct proportion to lesion depth. Linear equation was obtained between the optical density and the lesion depth by regression analysis. The result of caries activity test with laser fluorescence showed high correlation with those of $Cariescreen^{(R)}$ test and dDfFtT examination. Caries activity test with laser fluorescence showed 48% of sensitivity, 52% of specificity, and 45% of diagnostic power on the basis of dDfFtT examination, and also showed 48% of sensitivity, 51% of specificity, and 36% of diagnostic power on the basis of $Cariescreen^{(R)}$ test. In regard above result, caries activity test with laser fluorescence considered to be reliable for caries activity test compared with other oral environmental test. and it was also considered to be practical because it would be simple, inexpensive, and time saving method.

  • PDF

Cantilever deflection measurement system for AFM with PSD (PSD를 이요한 AFM용 미세 탐촉자의 변위측정장치)

  • 김홍준;장경영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.31-35
    • /
    • 2000
  • A cantilever deflection measurement system for AFM(atomic force microscope) was constructed by the laser deflection method using LEP type PSD. Design process including sensitivity analysis was presented and the performance of the system was demonstrated by several experiments using a sample specimen with 50nm-step on the surface. The measured displacement-amplification-factor showed good agreement with the expected one with about 8% deviation. The step height measurement data were compared to what were acquired by commercial AFM, and the result showed that there were about 5nm-deviation between the two data. These results satisfies our expectation in the stage of system design.

  • PDF

Method for Measuring Mechanical Behaviors of Thin Films at High Temperature (고온에서 박막의 기계적 거동 측정 방법)

  • Lim, Sang-Chai;Joo, Jae-Hwang;Kang, Ki-Ju
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.1
    • /
    • pp.102-108
    • /
    • 2003
  • Recently, the authors have developed a new material test system fur thin film at the high temperature. It is so compact and precise with sub micron resolution that it seems to be a useful tool fur research of the oxide film growth, its mechanical behavior and failure mechanism. To this end. in this paper three methologies are described for in-situ monitoring of the displacement & strain and the temperature, the oxide thickness. These are the Laser Speckle analysis with digital image correlation technique, the two-color infra-red thermometer and the laser reflection interferometry respectively. The calibration results and some issues which should be addressed for practical application are presented.

단일 이온 빔 증착법을 이용한 $MgF_2$$ZrO_2$ 박막의 제조

  • 강종석;강성건;김홍락;김동수;김광일
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.150-150
    • /
    • 1999
  • 재료의 광학적 특성을 변화시키기 위한 표면 코팅의 사용을 잘 알려져 있다. 그리고 이러한 광학 코팅은 우리가 주위에서 볼 수 있는 렌즈에서부터 레이저반사경 다 나아가 다양한 광학 필터에 이르기까지 빛의 간섭을 이용한 광학 박막의 코팅은 폭넓게 이용되고 있다. 그러한 응용가운데 불필요한 표면 반사를 방지함으로써 전체 투과율을 강화시키기 위한 무반사(Anti-Reflection) 코팅은 오늘날 광대역 무반사 특성 등 다양한 광학적 요구에 따라 하나 또는 그 이상의 층을 형성함으로써 극적으로 성취할 수 있다. 본 실험은 기존 많이 활용되는 증발법 그리고 스퍼터링 방법과는 달리 고진공하에서 증착 변수를 효과적으로 제어, 박막을 형성할 수 있는 자체 제작된 단일 IBS(Ion Beam Sputtering) 시스템을 이용하여 우수한 광학적 특성을 갖는 광학 재료로써 무반사용 다층박막 형성하기 앞서 MgF2, ZrO2 (yttria stabilized zirconia) 단층 박막을 제조하였으며, 각 증착 변수에 따른 결정학적 및 광학적 특성을 관찰하였다. 본 실험에 사용된 제조 장비로 Kaufman type 2.5inch의 이온 건이 장착된 Ion Beam sputtering 시스템으로 초기 진공도는 5$\times$10-6orr이며, 이온 빔의 전류 밀도는 Fareday cup을 이용했다. 6inch 크기의 ZrO2(yttria stabilized zirconia), MgF2 타겟트를 이용하여 Si(100), glass 기판위에 박막을 성장시켰다. 각 타겟트에 대한 증착변수로 이온 에너지, 기판온도, Ar 가스량을 변화시키면서 박막을 제조하였다. 제조된 박막의 광학적 특성으로 가시 영역에서 투과율의 변화는 자외/가시광선 분광 분석기 (UV/VIS specrophotometer)를 이용하여 측정했다. 그리고 박막의 조성 및 결정학적 구조는 AES EDS와 XRD로 확인하였다. 이온 빔 전압 500V, 빔 저류 55mA일 때 온도는 상온에서 30$0^{\circ}C$까지 승온 후 MgF2 박막의 XRD분석결과 우세한 결정성을 관찰할 수 없었으며, 이 때의 광 투과도는 가시영역에서 80~90%의 값으로 측정되었다. 추후 증착된 막의 결정성을 위해 열처리를 실시하고, 각 증착조건에 대한 결과는 학회 발표시 보고한다.

  • PDF

Measurement of Absorption and Scattering Coefficients of Biological Tissues by Time-Resolved Reflectance Method (시간 분해 반사율에 의한 생체조직의 흡수계수와 산란계수 측정)

  • Jeon, Kye-Jin;Park, Seung-Han;Kim, Ung;Yoon, Gil-Won
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.4
    • /
    • pp.499-505
    • /
    • 1997
  • A non-invasive technique to measure absorption and scattering coefficients was investigated The reflected backscattered light from the surface of phantom and biological tissue was obtained by using a time-correlated single photon counting system in pico-second time domain. The absorption and scattering coefficients were acquired by the time of peak and asymptotic behavior of the time-resolved reflectance curve and agreed well the ones that is obtained with deconvolution method It was found that the approximation method was good for biological medium to calculate optical properties due to its convenience and accuracy.

  • PDF