Development of a Real-time Medical Imaging System Combined with Laser Speckle Contrast Imaging and Fluorescence Imaging (형광과 레이저 스펙클 대조도 이미징을 결합한 실시간 의료영상 시스템 개발)

  • Shim, Min Jae;Kim, Yikeun;Ko, Taek Yong;Choi, Jin Hyuk;Ahn, Yeh-Chan
    • Journal of Biomedical Engineering Research
    • /
    • v.42 no.3
    • /
    • pp.116-124
    • /
    • 2021
  • It is important to differentiate between the target tissue (or organ) and the rest of the tissue before incision during surgery. And when it is necessary to preserve the differentiated tissues, the blood vessels connected to the tissue must be preserved together. Various non-invasive medical imaging methods have been developed for this purpose. We aimed to develop a medical imaging system that can simultaneously apply fluorescence imaging using indocyanine green (ICG) and laser speckle contrast imaging (LSCI) using laser speckle patterns. We designed to collect images directed to the two cameras on a co-axial optical path and to compensate equal optical path length for two optical designs. The light source used for fluorescence and LSCI the same 785 nm wavelength. This system outputs real-time images and is designed to intuitively distinguish target tissues or blood vessels. This system outputs LSCI images up to 37 fps through parallel processing. Fluorescence for ICG and blood flow in animal models were observed throughout the experiment.

Visualization of Vortex Flow around Coolant Outlets Using PIV and LDV (PIV와 LDV를 이용한 냉각수 토출구 주위의 와류 가시화 연구)

  • Hong, Ji-Woo;Shin, Su-Yong;Ahn, Byoung-Kwon
    • Journal of the Korean Society of Visualization
    • /
    • v.19 no.3
    • /
    • pp.136-142
    • /
    • 2021
  • Submerged and semi-submerged vehicles expel cooling water through an outlet. In this process, induced noise and vibration by the flow around the outlet have been reported, and it may cause problems directly related to survivability of the navy vessels. The coolant outlet has a net-type structure and circular columns are mostly used. In this study, flow measurements using PIV and LDV were performed for different type outlets; conventional (flat plate with round bar) and improved (flat and flat plate) configurations. Experiments were conducted at a cavitation tunnel where pressure and steady flow rate conditions are ensured for sufficient time to measure the flow. The average velocity field of the outlets were measured and compared through LDV measurements, and instantaneous vorticities were evaluated through PIV measurements. The results show that the improved type of the outlet is advantageous in terms of flow stability compared to the conventional type of the outlet.

Introduction of River Space Survey and Output Data using Drone (드론을 활용한 하천공간조사 및 산출물 소개)

  • Kim, Tae-Jeong;Kim, Chang-Sung;Kim, Sung-Hoon;Lee, Sung-Ho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.229-229
    • /
    • 2020
  • 최근 광학이미지 및 레이저를 활용한 계측 기술이 발전됨에 따라서 수공학 분야의 지리정보시스템(Geographic Information System, GIS) 및 원격탐사(Remote Sensing, RS) 기술의 활용 분야가 증가하고 있다. 광범위한 하천공간의 조사결과를 가시화하고 품질 및 활용성 제고를 위하여 GIS 및 RS 기술과 같은 고도화된 조사기술 및 장비의 도입하고 많이 활용하고 있다. 우리나라의 하천은 지형학적 특성으로 하천연장이 길고 접근성이 매우 불리하다. 하천정비 사업을 통하여 하천에 근접하게 접근할 수 있는 조건이 있다 하더라도 교목이나 지형지물에 의하여 시야 확보가 어려운 조사구간이 많다. 하천공간조사를 위한 드론 활용의 장점은 차량 및 도보로 접근이 어려운 조사대상에 접근하여 다양한 각도로 촬영하여 조사 목적에 부합하는 성과물 획득이 가능하다. 한국수자원조사기술원은 하도특성(평면, 사행 및 종횡단 조사)을 사전에 하천기본계획 보고서에서 곡률반경과 만곡도, 유심편향축, 최심하상경사 및 평균하상경사 등을 수집하고 현장에서 드론을 활용하여 접근조사가 어려운 항목에 대하여 드론을 적극적으로 활용하여 조사하고 있다. 드론을 활용할 경우 인력 및 소요시간이 대폭 절감되며 조사목적에 부합하는 다양한 조사 성과물을 얻을 수 있은 장점이 있다. 최종적으로 촬영된 영상자료는 넓은 범위의 하천공간을 고해상도 수치 지도화가 가능해 하천특성을 정량적으로 평가할 수 있을 것으로 판단된다.

  • PDF

Grain Size Analysis Using Morphological Properties of Grains (입자의 형태적 특성을 활용한 퇴적물 입도분석)

  • Choi, Kwang Hee
    • Journal of The Geomorphological Association of Korea
    • /
    • v.27 no.2
    • /
    • pp.19-28
    • /
    • 2020
  • Grain size analysis is the most basic procedure for identifying the origin, transport and sedimentation processes of sediments, and is widely used in geomorphology and sedimentology. Traditionally, grain size was determined by a sieve-pippette method, but the use of automated analyzers is increasing in recent years. These analyzers have many advantages over traditional techniques, but the measurement results are not always the same. It is still difficult to solve the pretreatment problem such as incomplete diffusion and residual organic matter, and inappropriate results may be obtained. This study compared image-based grain size analysis and sieve analysis to verify its statistical reliability, and conducted experiments to enhance the measurement accuracy using shape parameters. The results showed that the image-based analysis overestimated the grain size of sand dunes by about 7% compared to the sieve analysis, but the two measurements were not statistically different. In addition, by using shape parameters, such as aspect ratio, sphericity, and convexity, improved statistics were obtained compared to the original data. Using the morphological properties of the individual grains is a complementary method to the incomplete pretreatment of the grain size analysis process, and at the same time, it will contribute to improving the accuracy and reliability of the results.

Analyses of the Setup Errors using on Board Imager (OBI) (On Board Imager (OBI)를 이용한 Setup Error 분석에 대한 연구)

  • Kim, Jong-Deok;Lee, Haeng-O;You, Jae-Man;Ji, Dong-Hwa;Song, Ju-Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.1-5
    • /
    • 2007
  • Purpose: The accuracy and advantages of OBI(On Board Imager) against the conventional method like film and EPID for the setup error correction were evaluated with the analysis of the accumulated data which were produced in the process of setup error correction using OBI. Materials and Methods: The results of setup error correction using OBI system were analyzed for the 130 patients who had been planned for 3 dimensional conformal radiation therapy during March 2006 and May 2006. Two kilo voltage images acquired in the orthogonal direction were fused and compared with reference setup images. The setup errors in the direction of vertical, lateral, longitudinal axis were recorded and calculated the distance from the isocenter. The corrected setup error were analyzed according to the lesion and the degree of shift variations. Results: There was no setup error in the 41.5% of total analyzed patients and setup errors between 1mm and 5mm were found in the 52.3%. 6.1% patients showed the more than 5mm shift and this error were verified as a difference of setup position and the movement of patient in a treatment room. Conclusion: The setup error analysis using OBI in this study verified that the conventional setup process in accordance with the laser and field light was not enough to get rid of the setup error. The KV images acquired using OBI provided good image quality for comparing with simulation images and much lower patients' exposure dose compared with conventional method of using EPID. These advantages of OBI system which were confirmed in this study proved the accuracy and priority of OBI system in the process of IGRT(Image Guided Radiation Therapy).

  • PDF

A study of facial soft tissue of Korean adults with normal occlusion using a three-dimensional laser scanner (3차원 레이저 스캐너를 이용한 한국 성인 정상교합자의 안면 연조직에 대한 연구)

  • Baik, Hyoung-Seon;Jeon, Jai-Min;Lee, Hwa-Jin
    • The korean journal of orthodontics
    • /
    • v.36 no.1 s.114
    • /
    • pp.14-29
    • /
    • 2006
  • Developments in computer technology have made possible the 3-dimensional (3-D) evaluation of hard and soft tissues in orthodontic diagnosis, treatment planning and post-treatment results. In this study, Korean adults with normal occlusion (male 30, female 30) were scanned by a 3-D laser scanner, then 3-D facial images formed by the Rapidform 2004 program (Inus Technology Inc., Seoul, Korea.). Reference planes in the facial soft tissue 3-D images were established and a 3-D coordinate system (X axis-left/right, Y axis-superior/inferior, Z axis-anterior/posterior) was established by using the soft tissue nasion as the zero point. Twenty-nine measurement points were established on the 3-D image and 43 linear measurements, 8 angular measurements, 29 linear distance ratios were obtained. The results are as follows; there were significant differences between males and females in the nasofrontal angle $(male:\;142^{\circ},\;female:\;147^{\circ})$ and transverse nasal prominence $(male:\;112^{\circ},\;female:\;116^{\circ})$ (p<0.05). The transverse upper lip prominence was $107^{\circ}$ in males, $106^{\circ}$ in females and the transverse mandibular prominence was $76^{\circ}$ in both males and females. Li-Me' was 0.4 times the length of Go-Me'(mandibular body length) and the mouth height was also 0.4 times the width of the mouth width. The linear distance ratio from the coronal reference plane of FT, Zy, Pn, ULPm, Li, Me' was -1/-1/1/0.5/0.5/-0.6 respectively. The 3-D facial model of Korean adults with normal occlusion were be constructed using coordinate values and linear measurement values. These data may be used as a reference in 3-D diagnosis and treatment planning for malocclusion and dentofacial deformity patients and applied for 3-D analysis of facial soft tissue changes before and after orthodontic treatment and orthognathic surgery.

On-line Image Guided Radiation Therapy using Cone-Beam CT (CBCT) (콘빔CT (CBCT)를 이용한 온라인 영상유도방사선치료 (On-line Image Guided Radiation Therapy))

  • Bak, Jin-O;Jeong, Kyoung-Keun;Keum, Ki-Chang;Park, Suk-Won
    • Radiation Oncology Journal
    • /
    • v.24 no.4
    • /
    • pp.294-299
    • /
    • 2006
  • $\underline{Purpose}$: Using cone beam CT, we can compare the position of the patients at the simulation and the treatment. In on-line image guided radiation therapy, one can utilize this compared data and correct the patient position before treatments. Using cone beam CT, we investigated the errors induced by setting up the patients when use only the markings on the patients' skin. $\underline{Materials\;and\;Methods}$: We obtained the data of three patients that received radiation therapy at the Department of Radiation Oncology in Chung-Ang University during August 2006 and October 2006. Just as normal radiation therapy, patients were aligned on the treatment couch after the simulation and treatment planning. Patients were aligned with lasers according to the marking on the skin that were marked at the simulation time and then cone beam CTs were obtained. Cone beam CTs were fused and compared with simulation CTs and the displacement vectors were calculated. Treatment couches were adjusted according to the displacement vector before treatments. After the treatment, positions were verified with kV X-ray (OBI system). $\underline{Results}$: In the case of head and neck patients, the average sizes of the setup error vectors, given by the cone beam CT, were 0.19 cm for the patient A and 0.18 cm for the patient B. The standard deviations were 0.15 cm and 0.21 cm, each. On the other hand, in the case of the pelvis patient, the average and the standard deviation were 0.37 cm and 0.1 cm. $\underline{Conclusion}$: Through the on-line IGRT using cone beam CT, we could correct the setup errors that could occur in the conventional radiotherapy. The importance of the on-line IGRT should be emphasized in the case of 3D conformal therapy and intensity-modulated radiotherapy, which have complex target shapes and steep dose gradients.

Measurement Technique for Soil Loss Estimation Using Laser Distance Meter in Sloped Upland (거리측정기를 이용한 경사지 밭의 토양유실량 평가)

  • Park, Chol-Soo;Jung, Yeong-Sang;Joo, Jin-Ho;Lee, Gye-Jun
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.38 no.3
    • /
    • pp.127-133
    • /
    • 2005
  • The measurement technique using laser distometer to estimate soil erosion on sloped upland was assessed for its possibility for application. This technique was practiced in lysimeter installed in Chuncheon and Pyeongchang in 2001. The lysimeter installed at Chuncheon has 12% slope, 10 m slope length, 2 m width, and soil texture was sandy loam, while the lysimeter installed at Pyeongchang showed 23% slope, 15 m slope length, 5 m width, and sandy loam soil. Change of surface soil height was monitored using laser distance meter before and after rainy season on same spots. The Investigated periods in Chuncheon and Pyeongchang were from 22 June to 22 September and from July to October, respectively. Precipitation in Chuncheon and Pyeongchang in this period was 892.2 and 931.9 mm, respectively. Rainfall over 60% of annual precipitation was concentrated on July and August in Chuncheon and September and October in Pyeongchang, respectively. By monitoring the change of surface soil height using laser distance meter before and after rainy season, eroded soil surface in up-down fallow field in Chuncheon was 0.874 cm, while eroded soil surface in slant furrow field in Pyeongchang was 1.127 cm, which correspond to 79.5 and $98.0MT\;ha^{-1}$. Soil erosion increased as furrow length increased. Amounts of estimated soil loss using laser distance meter was 0.98-1.18 times higher compared to the estimated values through Iysimeter experiment, which implies possibility for application to monitor soil loss particularly in up-down and slant furrowed field. However, in the lysimeter with contoured tillage, amount of estimated soil loss using laser distance meter was approximately a half compared to that from lysimeter experiment, which implies inadequacy of distance meter application in contour- tillage field. The great soil loss difference between distance meter and lysimeter might be caused by disruption of some of the contoured furrows in lysimeter. The measurement technique using distometer in this study could be useful to estimate soil loss especially in up-down and slant-tillage fields.

A Study on Depth Data Extraction for Object Based on Camera Calibration of Known Patterns (기지 패턴의 카메라 Calibration에 기반한 물체의 깊이 데이터 추출에 관한 연구)

  • 조현우;서경호;김태효
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2001.06a
    • /
    • pp.173-176
    • /
    • 2001
  • In this thesis, a new measurement system is implemented for depth data extraction based on the camera calibration of the known pattern. The relation between 3D world coordinate and 2D image coordinate is analyzed. A new camera calibration algorithm is established from the analysis and then, the internal variables and external variables of the CCD camera are obtained. Suppose that the measurement plane is horizontal plane, from the 2D plane equation and coordinate transformation equation the approximation values corresponding minimum values using Newton-Rabbson method is obtained and they are stored into the look-up table for real time processing . A slit laser light is projected onto the object, and a 2D image obtained on the x-z plane in the measurement system. A 3D shape image can be obtained as the 2D (x-z)images are continuously acquired, during the object is moving to the y direction. The 3D shape images are displayed on computer monitor by use of OpenGL software. In a measuremental result, we found that the resolution of pixels have $\pm$ 1% of error in depth data. It seems that the error components are due to the vibration of mechanic and optical system. We expect that the measurement system need some of mechanic stability and precision optical system in order to improve the system.

  • PDF

The Evaluation on Accuracy of LiDAR DEM by Plotting Map (도화원도를 이용한 LiDAR DEM의 정확도 평가)

  • 최윤수;한상득;위광재
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.20 no.2
    • /
    • pp.127-136
    • /
    • 2002
  • DEM(Digital Elevation Model) is used widely in image processing, water resources, construction, GIS, landscape architecture, telecommunication, military operations and other related areas. And it is used especially in producing ortho-photo based on specific DEM and developing 3D GIS database vividly. As LiDAR(Light and Detection And Ranging) system emerged recently, DEM could be developed in urban area more efficiently and more economically, compared to the conventional DEM Production. Traditional method using check points for elevation has tome limitations in structure's height accuracy by LiDAR, because it uses only terrain height. Accordingly after the downtown of Chungju city was selected as a test field in this paper and DEM and digital ortho images was produced by way of LiDar survey, the accuracy was evaluated through analytical plotting map. The result shows that in case of buildings in LiDAR DEM, the accuracy is 0.30 m in X, 0.62 m in Y and RMS is 1.17 m. The difference distribution between DEM and plotting map in range of $\pm$10 cm was 36.2% and $\pm$10 cm $\pm$20 cm was 43.53%. The accuracy of LiDAR in this study meets 1/5,000 which is the regulation for map of NGI(National Geography Institute) and LiDAR can be possibly used in many other applied area.