• Title/Summary/Keyword: 레이저레이다

Search Result 73, Processing Time 0.042 seconds

Image Quality Evaluation for the Railway Abrasion Measurement with a High Resolution (고해상도 레일 마모도 측정을 위한 영상 평가)

  • Ahn, Sung-Hyuk;Kim, Man-Cheol
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.6
    • /
    • pp.887-894
    • /
    • 2009
  • There is no standard rule for the test of the railway abrasion measurement system composed of the line laser and the camera. This paper is proposed of the method to estimate the performance of the railway abrasion measurement system. The performance estimation is achieved by the quantitative analysis parameters such as MTF, NPS and DQE.

Design for Automotive Dual Beam Laser Rader (듀얼빔을 응용한 차량용 레이저레이다 설계)

  • Lee, Sung-Ki;Kim, Hyung-Moo;You, Kang-Soo;Lee, Kwang-Jae;Kwak, Hoon-Sung
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2005.11a
    • /
    • pp.599-602
    • /
    • 2005
  • 본 논문에서는 기존 단극성 원 빔 레이저 방식의 단점을 개선하기 위하여 듀얼 빔을 응용한 차량용 레이저 레이더 시스템을 설계하엿다. 양극성 m-시퀀스를 두 개의 레이저 파장에 할당함으로써 2차원 OOC(orthogonal optical codes)와 유사한 특성을 갖도록 하고 수신부에서 두 개의 단극성 신호를 차동구조를 이용하여 양극성 신호로 합성하는 방법을 이용, SNR 개선 방안을 제시한다. 시뮬레이션 결과, 제안한 듀얼 빔 방식이 기존의 원 빔 단극성 신호방식의 레이져 레이더 시스템에 비해 3dB의 SNR 개선이 가능함을 확인하였다.

  • PDF

Comparison on Autogenous Weldability of Stainless Steel using High Energy Heat Source (고에너지 열원에 따른 스테인리스강의 제살용접특성 비교)

  • Kim, Jong-Do;Lee, Chang-Je;Song, Moo-Keun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.8
    • /
    • pp.1076-1082
    • /
    • 2012
  • Today the welding for LNG carrier is known to be possible using arc and plasma arc welding process. But because of the lower energy density, arc welding is inevitable to multi-pass welding for thick plate and has a limit of welding speed compared to laser which is high energy density heat source. When thick plate is welded, weld defect by multi-pass welding and heat-affected zone by high heat-input were formed. Therefore one-pass welding by key-hole has been considered to work out the problems. It is possible for Laser, electron beam, plasma process to do key-hole welding. Nowadays, plasma process has been used for welding membrane of cargo tank for LNG carrier instead of arc process. Recently, many studies have examined to apply laser process to welding of membrane. In this paper, weldability, microstructure and mechanical properties of stainless steel for LNG carrier welded by fiber laser were compared to those by plasma. As a result, although the laser welding has several times faster speed, similar properties and smaller weld and heat affected zone were obtained. Consequently, this study proves the superiority of fiber laser welding for LNG carrier.

Tensile Bond Strength of Composite Resin Treated with Er:YAG Laser (Er:YAG 레이저를 활용한 와동형성시 컴포짓 결합강도)

  • Shin, Min;Ji, Young-Duk;Rhu, Sung-Ho;Cho, Jin-Hyoung
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.2
    • /
    • pp.269-276
    • /
    • 2005
  • This in vitro study evaluated the influence of a flowable composite resin on the tensile bond strength of resin to enamel and dentin treated with Er:YAG laser and diamond bur. 96 Buccal enamel and mid-coronal dentin were laser-irradiated using an Er:YAG laser and treated with diamond bur. Each groups(48) were divided two small groups depends on acid-etching procedure. Light-cure flowable resin(Metafil Flo) and self-cure resin(Clearfil FII New Bond) were used in this study. After surface etching with 37% phosphoric acid and the application of an adhesive system, specimens were prepared with a hybrid composite resin. After 24hours storage in distilled water at 37$^{\circ}C$, all samples were submitted to the tensile bond strength evaluation, using a universal testing machine(Z020, Zwick, Germany). The obtained results were as follows: 1. TBS of acid-etching group were higher than those of non-etching group in both enamel and dentin treated with Er:YAG laser and diamond bur. Laser 'conditioning' was clearly less effective than acid-etching. Moreover, acid etching lased enamel and dentin significantly improved the microTBS of M-Flo. 2. In enamel, TBS of laser-irradiated group were lower than those of bur-prepared group. However, in flowable resin subgroup, there were not differed those between two groups in dentin. 3. In laser-treated group, TBS of flowable composite resin were higher than those of self-curing resin in dentin, however, there was no difference in enamel. From this study, we can conclude that the self- and light-cure composite resin bonded significantly less effective to lased than to bur-cut enamel and dentin, and that acid-etch procedure remains mandatory even after laser ablation. We suggest that Er:YAG laser was useful for preparing dentin cavity with flowable resin filling.

Development of Operation Software for High Repetition rate Satellite Laser Ranging (고반복율 인공위성 레이저추적을 위한 운영 소프트웨어 개발)

  • Sung, Ki-Pyoung;Choi, Eun-Jung;Lim, Hyung-Chul;Jung, Chan-Gyu;Kim, In-Yeong;Choi, Jae-Seung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.12
    • /
    • pp.1103-1111
    • /
    • 2016
  • Korea Astronomy and Space Science Institute (KASI) has been operating SLR (Satellite Laser Ranging) system with 2kHz repetition rate for satellite precise orbit and spin determination as well as space geodesy. But the SLR system was improved to be capable of laser ranging with high repetition rate, up to 10kHz by developing new operation software and novel range gate generator, called HSLR-10. The HSLR-10 will contribute to the accurate spin rate determination of geodetic satellites and geodetic research due to its largest repetition rate in the world. In this study, the development methodology and configuration of operation software are addressed, and its validation results are also presented.

거리계측을 위한 펄스구동 레이저의 구조 설계 및 제작

  • Kim, Jeong-Ho;Im, Ju-Yeong;Im, Jeong-Un;Han, Su-Uk;Park, Jang-Ho;Sin, Seung-Hak;Kim, Jong-Seop;Kim, Yun-Hyeon;Im, Yeong-Eun;Park, Jong-Bok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.332.1-332.1
    • /
    • 2014
  • 정보통신 기술의 발전으로 지능형 자동차와 같은 미래형 고부가 가치 자동차 산업은 지속적인 성장이 기대된다. 그리고, 안전과 직결되는 차간 거리 계측은 다양한 종류의 센서에 의해 측정이 되고 있으며, 운전자 및 탑승자의 생명을 보호하고 있다. 다양한 차간 거리센서 중에서도 전방의 물체 인식 및 넓은 영역, 장거리에 대한 센싱은 레이저를 이용하여 구현할 수 있다. 본 논문은 자동차 뿐만 아니라, 지능형 자율 주행시 전방의 물체 인식 및 거리 계측 센서로 적용이 가능한 반도체 레이저의 설계 및 제작에 관해 소개한다. 반도체 레이저는 물질에 따라 각각 다른 파장대역의 광을 조사하고 있으며 이 레이저 빔은 물체에 맞고 부딪히면 반사되어 되돌아 오는 특성을 가지고 있다. 따라서, 펄스 구동에 의해 단위 펄스당 출사되는 레이저는 전방 물체에 부딪혀 되돌아 오는 시간을 구하게 되면 레이저 광원에서 물체까지의 거리를 구할 수가 있게 된다. 여기서 펄스 레이저의 출력은 물체 감지가 가능한 거리의 정보를 가지고 있으며, 펄스로 구동될 때 반복 주파수 및 펄스 폭은 각각 거리계측 시간과 분해능을 결정하는 주요 요소가 된다. 따라서, 장거리 물체의 계측과 물체 식별 능력을 높이기 위해서는 반도체 레이저의 출력을 높이고 펄스폭을 줄여서 분해능을 향상하는 것이 필요하다. 또한, 물체 인식 또는 계측 시간을 빠르게 하기 위해서는 고속 주파수로 동작하게 되면 가능해 질 것이다. 본 논문은 1,550 nm 대역의 반도체 레이저를 제작하여 펄스 구동으로 출력과 펄스폭을 측정하였다. 또한, 보다 높은 전류에서 칩 단면의 열화를 방지하기 위한 기술을 적용하여 설계 및 제작된 레이저의 특성을 측정하여 향후, 지능형 자동차의 레이저 레이다(LIDAR)와 같은 응용분야에 많이 활용될 수 있을 것으로 기대한다.

  • PDF

Development of Raman Laser Radar System for Aerosol and Water Vapor Measurements (에어로졸, 수증기 측정 라만 레이저 레이다 시스템 개발)

  • Park, Chan-Bong;Lee, Young-Woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.158-161
    • /
    • 2012
  • Raman Laser Radar system for the measurements of aerosol and water vapor concentration is developed. As a transmitting system, Nd:YAG laser with 3rd harmonic Generator and beam expander are used. The wavelength of transmitting laser is 355 nm. The receiving system is consists of 500 mm telescope, 3-channel Raman spectrometer, PMT, and signal processing module. The wavelengths of received signals are 355 nm. 387 nm, and 408 nm 이다. The measurable altitude of this system is about 3~4 km with spatial resolution of 100~200 m.

  • PDF

A Study on the Synthetic Aperture Radar Processor using AOD/CCD (AOD/CCD를 이용한 합성개구면 레이다 처리기에 관한 연구)

  • 박기환;이영훈;이영국;은재정;박한규
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.10
    • /
    • pp.1957-1964
    • /
    • 1994
  • In this thesis, a Synthetic Aperture Rarar Processor that is possible real-time handling is implemented using CW(Continuose Wave) laser as a light source, CCD(charge Coupled Device) as a time integrator, and AOD(Acousto-Optic Device) as the space integrator. One of the advantages of the proposed system is that it does not require driving circuits of the light source. To implement the system, the linear frequency modulation(chirp) technique has been used for radar signal. The received data for the unit target was processed using 7.80 board and accompanying electronic circuits. In order to reduce the smear effect of the focused chirp signal which occurs Bragg diffrection angle of the AOD has been utilized to make sharp pulses of the laser source, and the pulse made synchronized with the chirp signal. Experiment and analysis results of the data and images detected from CCD of the proposed SAR system demonstrated that detection effect is degrated as the unit target distance increases, and the resolving power is improved as the bandwidth of the chirp signal increases. Also, as the pulse width of the light source decreases, the smear effect has been reduced. The experimental results assured that the proposed system in this papre can be used as a real time SAR processor.

  • PDF