• Title/Summary/Keyword: 랩온어칩

Search Result 19, Processing Time 0.025 seconds

Thermal Design of PCR Chip for LOC (랩온어칩을 위한 중합효소 연쇄반응 칩의 열설계)

  • Kim, Deok-Jong;Kim, Jae-Yun;Park, Sang-Jin;Heo, Pil-U;Yun, Ui-Su
    • 연구논문집
    • /
    • s.33
    • /
    • pp.17-25
    • /
    • 2003
  • In this work, thermal design of a PCR chip for LOC is systematically conducted. From the numerical simulation of a PCR chip based on the finite volume method, how to control the average temperature of a PCR chip and the temperature difference between the denaturation zone and the annealing zone is presented. The average temperature is shown to be controlled by adjusting heat input and a cooler as well as a heater is shown to be necessary to obtain three individual temperature zones for polymerase chain reaction. To reduce the time required, a heat sink for the cooler is not included in the calculation domain for the PCR chip and heat sink design is conducted separately by using a compact modeling method, the porous medium approach.

  • PDF

Study on flow behavior of polymer solutions in microchannels (미세구조 내에서의 사출성형 흐름에 관한 연구)

  • Kim Dong-Hak;Xu Guojun;Koelling Kurt W.;Lee L.James
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.3
    • /
    • pp.471-475
    • /
    • 2006
  • Filling the microchannels is very important in designing micro-injection molding, microdevices, etc. In this paper, flow dynamics was studied in injection molding with microchannels. A transparent PMMA mold was designed and the flow dynamics was observed. The experiment was performed using poly (ethylene oxide) (PEO) and polyacrylamide (PA) aqueous solutions. The transignt dynamic flow and flow competition between the base plate and the microchannels were observed. The flow observation was used to explain previous filling length results in microchannels during micro-injection molding.

  • PDF

A Consideration on the Process Technology and Application of MEMS to prepare for upcoming MEMS-based technological paradigm (MEMS 기반의 새로운 기술적 패러다임에 대비한 공정 기술 분석 및 적용에 대한 고찰)

  • Ko, Yun-Seok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.7
    • /
    • pp.979-986
    • /
    • 2013
  • Recently, in the electric, electronic, robotic, and medical industries, a great attention has been paid to the development of MEMS-based smart devices with a compact size and highly intelligency. The MEMS technology is very effective in designing into a compact size and lightweight by combining into one the complex electrical, mechanical, chemical, and biological features which are required by smart devices, and at the same time, in bulk batch manufacturing. Therefore, this study, to prepare for upcoming new MEMS-based technological paradigm, analyzes MEMS processes and then considers its Applications.

One-Touch Type Immunosenging Lab-on-a-chip for Portable Point-of-care System (휴대용 POC 시스템을 위한 원터치형 면역 센싱 랩온어칩)

  • Park, Sin-Wook;Kang, Tae-Ho;Lee, Jun-Hwang;Yoon, Hyun-C.;Yang, Sang-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.8
    • /
    • pp.1424-1429
    • /
    • 2007
  • This paper presents a simple and reliable one-touch type multi-immunosensing lab-on-a-chip (LOC) detecting antibodies as multi-disease markers using electrochemical method suitable for a portable point-of-care system (POCS). The multi-stacked LOC consists of a PDMS space layer for liquids loading, a PDMS valve layer with 50 im in height for the membrane, a PDMS channel layer for the fluid paths, and a glass layer for multi electrodes. For the disposable immunoassay which needs sequential flow control of sample and buffer liquids according to the designed strategies, reliable and easy-controlled on-chip operation mechanisms without any electric power are necessary. The driving forces of sequential liquids transfer are the capillary attraction force and the pneumatic pressure generated by air bladder push. These passive fluid transport mechanisms are suitable for single-use LOC module. Prior to the application of detection of the antibody as a disease marker, the model experiments were performed with anti-DNP antibody and anti-biotin antibody as target analytes. The flow test results demonstrate that we can control the fluid flow easily by using the capillary stop valve and the PDMS check valves. By the model tests, we confirmed that the proposed LOC is easily applicable to the bioanalytic immunosensors using bioelectrocatalysis.

A Study on the MHD Micropump with Mixing Function (혼합 기능을 갖는 마이크로 펌프의 연구)

  • Choi, Bum-Kyoo;Kang, Ho-Jin;Kim, Min-Sock
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.6
    • /
    • pp.579-586
    • /
    • 2010
  • With the development of micrototal analysis systems (${\mu}TAS$), which is a result of enhancement of MEMS technology, rapid progress has been achieved in medical and biological research. The study of lab-on-a-chip (LOC) devices, which are types of ${\mu}TAS$ and which integrate the functions of mixing and analyzing tiny amounts of samples and reagents on one chip, has actively progressed. An LOC comprises microfluidic components such as micromixers and micropumps. Because the flow in a microfluidic system is generally laminar, it is very difficult to efficiently mix and feed fluid reagents. This paper presents the design and the method of fabrication of an MHD micropump for mixing fluids. By using this micropump, fluids are simultaneously mixed and pumped; this is achieved by coupling the Lorentz force and force exerted by an electric charge moving in an electric field.

Energy Harvesting from Reverse Electrodialysis in Ion-Selective Membrane Formed with Self-Assembled Nanoparticles (미세유체칩 내 자기조립화된 나노입자로 이루어진 이온교환막을 이용한 역전기투석 에너지 발전)

  • Choi, Eunpyo;Kwon, Kilsung;Kim, Daejoong;Park, Jungyul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.5
    • /
    • pp.437-441
    • /
    • 2014
  • This paper presents a novel microplatform for high power generation based on reverse electrodialysis. The ideal cation-selective membrane for power generation was realized using geometrically controlled in situ self-assembled nanoparticles. Our proposed membranes can be constructed through a simple and cost-effective process that uses microdroplet control with nanoparticles in a microchannel. Another advantage of our system is that the maximum power and energy conversion efficiency can be improved by changing the geometry of the microchannel and proper selection of the nanoparticle size and material. This proposed platform can be used to supply power sources to other microdevices and contribute to a fundamental understanding of ion transport behavior and the power generation mechanism.

A Simulation of Advanced Multi-dimensional Isotachophoretic Protein Separation for Optimal Lab-on-a-chip Design (최적화된 Lab-on-a-chip 설계를 위한 향상된 다차원 프로틴 등속영동 시뮬레이션)

  • Cho, Mi-Gyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.7
    • /
    • pp.1475-1482
    • /
    • 2009
  • In this paper, a computer simulation is developed for isotachophoretic protein separation in a serpentine micro channel for optimal lab on a chip design using 2D Finite Element Method. This 2D ITP model is composed of 5 components such as hydrochloric acid as Leader, caproic acid as terminator, acetic acid and benzoic acid as two proteins, and histindine as background electrolyte. The computer model is based on mass conservation equation for 5 components, charge conservation equation for electric potential, and electro neutrality condition for pH calculation. For the validation of the 2D spatial ITP model, the results are compared with the Simul5 developed by Bohuslav Gas Group. The simulation results are in a good agreement in a ID planar channel. This proves the precision of our model. The 2Dproteinseparation is conducted in a 2D curved channel for Lab on a chip design and dispersions of proteins are revealed during the electrophoretic process in a curved shape.

Diagnostic Methods of Respiratory Virus Infections and Infection Control (호흡기 바이러스 감염의 진단법과 감염관리)

  • Park, Chang-Eun
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.53 no.1
    • /
    • pp.11-18
    • /
    • 2021
  • Respiratory viruses (RVs) cause infections in hospital environments through direct contact with infected visitors. In infection control, it causes major problems of acquired infections in hospitals by respiratory viruses. The surveillance data derived from clinical laboratories are often used to properly allocate medical resources to hospitals and communities for treatment, consumables, and diagnostic product purchases in the institutions and public health sectors that provide health care. An early diagnosis is essential in infection with respiratory viruses, and methods that can be used in diagnostic methods using respiratory samples include virus culture, molecular diagnosis, and analysis. A microchip provides a new strategy for developing a more diverse and powerful technology called point-of-care testing. The importance of the respiratory system should be applied strictly to the infection control guidelines to ensure the occupational health and safety of health care workers. Evidence of clinical efficacy, including this study, is challenging the long-standing paradigm for infection propagation. Additional assistance will be needed for frequent tests to detect respiratory viruses in inpatients who have begun to show new respiratory symptoms indicating infections requiring efforts to control the infection.

Electrical and Fluidic Characterization of Microelectrofluidic Bench Fabricated Using UV-curable Polymer (UV경화성 폴리머를 이용한 미소유체 통합접속 벤치 개발 및 전기/유체적 특성평가)

  • Youn, Se-Chan;Jin, Young-Hyun;Cho, Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.5
    • /
    • pp.475-479
    • /
    • 2012
  • We present a novel polymer fabrication process involving direct UV patterning of a hyperbranched polymer, AEO3000. Compared to PDMS, which is the most widely used polymer in bioMEMS devices, the present polymer has advantages with regard to electrode integration and fast fabrication. We designed a four-chip microelectrofluidic bench having three electrical pads and two fluidic I/O ports. We integrated a microfluidic mixer and a cell separator on the bench to characterize the interconnection performance and sample manipulation. Electrical and fluidic characterization of the microfluidic bench was performed. The measured electrical contact resistance was $0.75{\pm}0.44{\Omega}$, which is small enough for electrical applications, and the pressure drop was 8.3 kPa, which was 39.3% of the value in the tubing method. By performing yeast mixing and a separation test in the integrated module on the bench, we successfully showed that the interconnected chips could be used for bio-sample manipulation.