• Title/Summary/Keyword: 디퓨저 유동

Search Result 86, Processing Time 0.025 seconds

Analysis of Turbulent flow using Pressure Gradient Method (압력구배기법을 이용한 난류 유동장 해석)

  • 유근종
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.3 no.2
    • /
    • pp.1-9
    • /
    • 1999
  • Applicability of the pressure gradient method which is formulated based on pressure gradient is verified against turbulent flow analysis. In the pressure gradient method, pressure gradient instead of pressure itself is obtained using continuity constraint. Since correct pressure gradient is found only when mass conservation is satisfied, pressure gradient method can reflect physics of flow field properly The pressure gradient method is formulated with semi-staggered grid system which locates each primitive variables on the same grid point but evaluates pressure gradient in-between. This grid system ensures easy programming and reflection of correct physics in analysis. For verifying applicability of this method, the pressure gradient method is applied to turbulent flow analysis with low Reynolds number $\kappa$-$\varepsilon$ model. Turbulent flows include fully developed channel flow, backward-facing step flow, and conical diffuser flow. Prediction results show that the pressure gradient method can be applied to turbulent flow analysis. However, the pressure gradient method requires somewhat long computation time. Proper way to find optimum under-relaxation factor, $\gamma$, is also need to be developed.

  • PDF

The Flow Characteristics in a Vaneless Diffuser by PIV Measurements (PIV측정에 의한 깃 없는 디퓨저에서의 유동특성)

  • Yoon, Ji-In;Shin, You-Hwan;Lee, Yoon-Pyo;Kim, Kwang-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.2
    • /
    • pp.45-50
    • /
    • 2012
  • The flow characteristics in a vaneless diffuser with a backswept radial impeller have been experimentally investigated according to the variation of discharge flow rate. Particle image velocimetry(PIV) system was applied to measure velocity fields with several operating conditions and on some diffuser horizontal planes. Pressure transducers were installed on hub wall of the diffuser in order to analyze the pressure fluctuations and their corresponding velocity fields. The results show that the location of the main flow center moves from the hub to the shroud side as the flow rate decreases, and the reverse flow is locally generated on the hub side.

Computational Study of the Bleed-Pump Type Subsonic/Sonic Ejector Flows (추기 펌프형 아음속/음속 이젝터유동에 관한 수치해석적 연구)

  • Kim, Heuy-Dong;Kwon, Oh-Sik;Koo, Byoung-Soo;Choi, Bo-Gyu
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.485-490
    • /
    • 2000
  • This paper dipicts the computational results for the axisymmetric subsonic/sonic ejector systems with a second throat. The numerical simulations are based on a fully implicit finite volume scheme of the compressible Reynolds-Averaged Navier-Stokes equation in a domain that extends form the stagnation chamber to the ejector diffuser exit. In order to obtain practical design factors for subsonic/sonic ejector systems, the ejector throat area, the mixing section configuration, and the ejector throat length were changed in computations. For the subsonic/sonic ejector systems operating in the range of low operation pressure ratio, the effects of the design factors on the flow are discussed.

  • PDF

An Experimental Study of Sonic/Supersonic Ejector Flows (음속/초음속 이젝터 유동에 관한 실험적 연구)

  • Kim, Hui-Dong;Choe, Bo-Gyu;Gwon, O-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.5
    • /
    • pp.640-647
    • /
    • 2002
  • An experimental investigation or the sonic and supersonic air ejector systems has beer conducted to develop design and prediction programs for practical ejector system. Five different primary nozzles have been employed to operate the ejector systems in the ranges of low and moderate operating pressure ratios. The ejector operating pressure ratio for the secondary chamber pressure to be minimized has a strong influence of the ejector throat ratio. The pressure inside the ejector diffuser is not dependent on the primary nozzle configurations employed but only a function of the ejector operating pressure ratio. Experimental results show that a supersonic ejector system is more desirable for obtaining high vacuum pressure of the secondary chamber than a sonic ejector system.

A Study on Inflow Rate Variation for Shrouded Wind Turbine Rotors (쉬라우드가 장착된 풍력터빈 로터의 유입 유량 변동 특성 연구)

  • Ham, Hwi-Chan;Kim, Ho-Hyeon;Lee, Chae-Yeon
    • Proceeding of EDISON Challenge
    • /
    • 2015.03a
    • /
    • pp.563-568
    • /
    • 2015
  • 풍력터변의 성능을 높이기 위한 방법으로 최근 해외에서는 쉬라우드를 장착하여 유입 유량을 증진시키는 형상에 대한 새로운 아이디어가 제안되고 시범적으로 적용되고 있다. 본 연구에서는 쉬라우드가 장착된 수평축 풍력터빈에 대해서 EDISON CFD를 이용하여 쉬라우드 내부로 유입되는 질량 유량의 변동을 몇 가지 형상에 대해 수치적으로 비교 분석하였다. 유동장은 비압축성 난류유동으로 가정하였으며, 수치 해석 결과로부터 쉬라우드 주변의 순환의 세기를 형상 변동에 따라 도출하였다. 쉬라우드 형상으로는 캠버를 갖는 goe 417 에어포일을 두 개의 받음각(5도, 10도)에 대해서 수치해석을 수행하였으며, 브림을 갖는 디퓨저 형상(Wind-lens)에 대해서도 유입 유량 변동과 순환 세기에 대해 수치해석을 수행하고 결과를 상호 비교하였다. 본 연구를 통해 쉬라우드가 발생시키는 순환에 의한 유입 유량 증가 현상을 파악할 수 있었으며, 이로써 풍력터빈의 출력을 증대시킬 수 있음을 확인하였다.

  • PDF

Aerodynamic Design and Numerical Analysis on a Transonic Centrifugal Compressor (천음속 원심압축기의 공력설계 및 수치해석)

  • Choi, Jae-Ho
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.12 no.4
    • /
    • pp.56-62
    • /
    • 2008
  • This study presents the aerodynamic design and numerical analysis results on a transonic centrifugal compressor which is used for gas turbine systems. Mean-line analysis and quasi-3D analysis are used for the aerodynamic design, and Reynolds-averaged Navier-Stokes analysis is applied to flow analysis of the compressor. The aerodynamic parameters for a transonic compressor, such as pressure coefficient, swirl parameter, blade loading, are discussed, and flow characteristics in the impeller and diffuser are discussed.

Computations of the Bleed-Pump Type Subsonic/Sonic Ejector Flows (추기 펌프형 아음속/음속 이젝터유동에 관한 수치해석적 연구)

  • Choe, Bo-Gyu;Gu, Byeong-Su;Kim, Hui-Dong;Kim, Deok-Jul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.2
    • /
    • pp.269-276
    • /
    • 2001
  • This paper dipicts the computational results for the axisymmetric subsonic/sonic ejector systems with a second throat. The numerical simulations are based on a fully implicit finite volume scheme of the compressible Reynolds-Averaged Navier-Stokes equation in a domain that extends from the stagnation chamber to the ejector diffuser exit. In order to obtain practical design factors for subsonic/sonic ejector systems, the ejector throat area, the mixing section configuration, and the ejector throat length were changed in computations. For the subsonic/sonic ejector systems operating in the range of low operation pressure ratio, the effects of the design factors on the flow are discussed.

A Numerical Analysis of Pulse-Jet Cleaning Characteristics for Ceramic Filter System Design (세라믹필터 집진장치의 역세정 시스템 설계를 위한 유동해석)

  • 정재화;서석빈;김시문;안달홍;김종진
    • Journal of Energy Engineering
    • /
    • v.12 no.3
    • /
    • pp.197-206
    • /
    • 2003
  • A numerical analysis of the pulse-jet cleaning characteristics in a porous ceramic candle filter system was performed. To obtain the detailed velocity and pressure distribution during the cleaning process in a porous filter system, the axi-symmetric compressible Navier-Stokes equations including energy conservation equation were solved by using the FLUENT code which adopts FVM (Finite Volume Method). The effects of pulse cleaning nozzle diameter, nozzle tip position, permeability of a porous ceramic candle filter, diffuser throat diameter, and cleaning pressure on the cleaning flow characteristics were investigated extensively.

Study on the Gas-Liquid Mixing System by Using Ejector (이젝터를 사용하는 기-액 혼합시스템에 관한 연구)

  • Jin, Zhen-Hua;Kim, Pil-Hwan;Park, Gi-Tae;Chung, Han-Shik;Jeong, Hyo-Min
    • Journal of Power System Engineering
    • /
    • v.12 no.3
    • /
    • pp.5-11
    • /
    • 2008
  • 산업공정에서 널리 사용하는 반응기는 성질이 상이한 물질을 혼합하는 시스템으로서 본 연구에서는 이젝터(ejector)에 의한 반응기의 개발을 수행하였다. 액체-가스 이젝터는 구동유체에 의하여 기체가 흡입되면서 각종 유해가스를 제거하는 목적 또는 기체와 액체의 혼합 등 목적으로 사용된다. 본 실험에서 액체구동 가스혼합반응기의 실험 장치를 구축하고 이젝터 내부의 유동패턴과 기체용해도 자료를 도출하며 고효율 이젝터 설계를 위한 진공도 측정과 디퓨저 각도가 다른 이젝터의 실험 및 수치해석을 수행하였다. 이젝터의 성능은 흡입 측에서의 진공압력으로 평가되며 이 진공압력은 이젝터의 노즐 설계 및 유동조건에 의하여 결정되므로 이에 대한 기본적인 특성 도출이 선결되어야 한다. 순환유체의 유량이 70LPM, 80LPM 90LPM조건에서 두 가지 디퓨저에 대하여 비교실험을 수행하였다. 실험적 연구와 수치해석연구를 통하여 혼합성능과 이젝터의 내부유동특성에 대하여 고찰한 결과 디퓨저의 각도가 5.0도일 때 진공도가 더욱 높으며 구동액체의 유량이 작을 때는 진공도차이가 크지만 유량이 증가함에 따라 진공도 차이가 감소된다. 구동액체의 유량이 증가할수록 용존산소농도는 증가하며 디퓨저의 각도가 5.0도일 때는 용존산소 농도가 더 높게 나타나는 것을 확인할 수 있었다.

  • PDF

Computations of the Supersonic Ejector Flows with the Second Throat (2차목을 가지는 초음속 이젝터 유동에 관한 수치계산)

  • Choi, Bo-Gyu;Lee, Young-Ki;Kim, Heuy-Dong;Kim, Duck-Jool
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.8
    • /
    • pp.1128-1138
    • /
    • 2000
  • Pumping action in ejector systems is generally achieved through the mixing of a high-velocity and high-energy stream with a lower-velocity and lower-energy stream within a duct. The design and performance evaluation of the ejector systems has developed as a combination of scale-model experiments, empiricism and theoretical analyses applicable only to very simplified configurations, because of the generic complexity of the flow phenomena. In order to predict the detailed performance characteristics of such systems, the flow phenomena throughout the operating regimes of the ejector system should be fully understood. This paper presents the computational results for the two-dimensional supersonic ejector system with a second throat. The numerical simulations are based on a fully implicit finite volume scheme of the compressible Reynolds-averaged Navier-Stokes equation in a domain that extends from the stagnation chamber to the diffuser exit. For a wide range of the operating pressure ratio the flow field inside the ejector system is investigated in detail. The results show that the supersonic ejector systems have an optimal throat area for the operating pressure ratio to be minimized.