DOI QR코드

DOI QR Code

The Flow Characteristics in a Vaneless Diffuser by PIV Measurements

PIV측정에 의한 깃 없는 디퓨저에서의 유동특성

  • 윤지인 (한국과학기술연구원 에너지메카닉스연구센터) ;
  • 신유환 (한국과학기술연구원 에너지메카닉스연구센터) ;
  • 이윤표 (한국과학기술연구원 에너지메카닉스연구센터) ;
  • 김광호 (한국과학기술연구원 에너지메카닉스연구센터)
  • Received : 2011.09.23
  • Accepted : 2012.01.16
  • Published : 2012.04.01

Abstract

The flow characteristics in a vaneless diffuser with a backswept radial impeller have been experimentally investigated according to the variation of discharge flow rate. Particle image velocimetry(PIV) system was applied to measure velocity fields with several operating conditions and on some diffuser horizontal planes. Pressure transducers were installed on hub wall of the diffuser in order to analyze the pressure fluctuations and their corresponding velocity fields. The results show that the location of the main flow center moves from the hub to the shroud side as the flow rate decreases, and the reverse flow is locally generated on the hub side.

Keywords

References

  1. Pinarbasi, A., and Johnson, M. W., 1994, "Detailed Flow Measurements in a Centrifugal Compressor Vaneless Diffuser," Journal of Turbomachinery, Vol. 116, pp. 453-460. https://doi.org/10.1115/1.2929432
  2. Ubaldi, M., Zunino, P., and Ghiglione, A., 1998, "Detailed Flow Measurements within the Impeller and the Vaneless Diffuser of a Centrifugal Turbomachine," Experimental Thermal and Fluid Science, Vol. 17, pp. 147-155. https://doi.org/10.1016/S0894-1777(97)10060-7
  3. Akhras, A.-R., EI Hajem, M., Morel, R., and Champagne, J.-Y., 2001, "Internal Flow Investigation of a Centrifugal Pump at the Design Point," Journal of Visualization, Vol. 4, No. 1, pp. 91-98. https://doi.org/10.1007/BF03182459
  4. Paone, N., Riethmuller, M. L., and Van den Braembussche, R. A., 1989, "Experimental Investigation of the Flow in the Vaneless Diffuser of a Centrifugal Pump by Particle Image Displacement Velocimetry," Experiments in Fluids, Vol. 7, pp. 371-378. https://doi.org/10.1007/BF00193417
  5. Wernet, M. P., 2000, "Development of Digital Particle Imaging Velocimetry for use in Turbomachinery," Experiments in Fluids, Vol. 28, pp. 97-115. https://doi.org/10.1007/s003480050015
  6. Wernet, M. P., Bright, M. M., and Skoch, G. J., 2001, "An Investigation of Surge in a High-speed Centrifugal Compressor using Digital PIV," Journal of Turbomachinery, Vol. 123, pp. 418-428. https://doi.org/10.1115/1.1343465
  7. Pedersen, N., Larsen, P. S., and Jacobsen, C. B., 2003, "Flow in a Centrifugal Pump Impeller at Design and Off-design Conditions-part 1: Particle Image Velocimetry (PIV) and Laser Doppler Velocimetry (LDV) Measurements," Journal of Fluids Engineering, Vol. 125, pp. 61-72. https://doi.org/10.1115/1.1524585
  8. Wuibaut, G., Bois, G., Dupont, P., Caignaert, G., and Stanislas, M., 2002, "PIV Measurements in the Impeller and the Vaneless Diffuser of a Radial Flow Pump in Design and Off-design Operating Conditions," Journal of Fluids Engineering, Vol. 124, pp. 791-797. https://doi.org/10.1115/1.1486473
  9. Choi, Y. D., Nishino, K., Kurokawa, J., and Matsui, J., 2004, "PIV Measurements of Internal Flow Characteristics of Very Low Specific Speed Semi-open Impeller," Experiments in Fluids, Vol. 37, pp. 617-630. https://doi.org/10.1007/s00348-004-0838-7
  10. Dazin, A., Cavazzini, G., Pavesi, G., Dupont, P., Coudert, S., Ardizzon, G., Caignaert, G., and Bois, G., 2011, "High-speed Stereoscopic PIV Study of Rotating Instabilities in a Radial Vaneless Diffuser," Experiments in Fluids, Vol. 51, No. 1, pp. 83-93. https://doi.org/10.1007/s00348-010-1030-x
  11. Ljevar, S., de Lange, H. C., and van Steenhoven, A. A., 2006, "Two-dimensional Rotating Stall Analysis in a Wide Vaneless Diffuser," International Journal of Rotating Machincery Vol. 2006, pp. 1-11.