Image Comparison of Curved and Flat Panel Detectors for the Application of Digital Radiography Testing in Pipe Welds (배관 원둘레 이음 용접부의 디지털 방사선 투과 검사 적용을 위한 커브드 및 평면형 검출기의 영상 비교)

  • Yang, Jin-Wook;Cho, Kap-Ho;Nam, Mun-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.5
    • /
    • pp.585-594
    • /
    • 2022
  • The detector for digital radiography testing, which is currently mainly used, consists of a detector with a flat structure, making it impossible to fully adhere to the digital radiography testing of the test object with curvature. In this study, a curved panel detector capable of adhering to curvature was fabricated to improve the quality of the digital image during the digital radiography testing of piping welds at industrial sites, and digital radiography images using flat and curved panel detectors were obtained for 6in pipes with different nominal thickness. As a result of the experiment, it was confirmed that the flat panel detector does not fully adhere to the pipe, resulting in a gap between the outer part of the pipe and the detector, resulting in a difference in the unsharpness and diffusion of the digital image. On the other hand, it was confirmed that the curved panel detector minimizes the gap between the pipe outer part and the detector, so that digital image diffusion is less than that of the flat panel detector. The higher the confidence of the image, the lower the quality and error in reading, so it is believed that higher quality images can be obtained than conventional flat panel detectors when using detectors that can be closely attached to the inspection object.

Development of $14"{\times}8.5"$ active matrix flat-panel digital x-ray detector system and Imaging performance (평판 디지털 X-ray 검출기의 개발과 성능 평가에 관한 연구)

  • Park, Ji-Koon;Choi, Jang-Yong;Kang, Sang-Sik;Lee, Dong-Gil;Seok, Dae-Woo;Nam, Sang Hee
    • Journal of radiological science and technology
    • /
    • v.26 no.4
    • /
    • pp.39-46
    • /
    • 2003
  • Digital radiographic systems based on solid-state detectors, commonly referred to as flat-panel detectors, are gaining popularity in clinical practice. Large area, flat panel solid state detectors are being investigated for digital radiography. The purpose of this work was to evaluate the active matrix flat panel digital x-ray detectors in terms of their modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE). In this paper, development and evaluation of a selenium-based flat-panel digital x-ray detector are described. The prototype detector has a pixel pitch of $139\;{\mu}m$ and a total active imaging area of $14{\times}8.5\;inch^2$, giving a total 3.9 million pixels. This detector include a x-ray imaging layer of amorphous selenium as a photoconductor which is evaporated in vacuum state on a TFT flat panel, to make signals in proportion to incident x-ray. The film thickness was about $500\;{\mu}m$. To evaluate the imaging performance of the digital radiography(DR) system developed in our group, sensitivity, linearity, the modulation transfer function(MTF), noise power spectrum (NPS) and detective quantum efficiency(DQE) of detector was measured. The measured sensitivity was $4.16{\times}10^6\;ehp/pixel{\cdot}mR$ at the bias field of $10\;V/{\mu}m$ : The beam condition was 41.9\;KeV. Measured MTF at 2.5\;lp/mm was 52%, and the DQE at 1.5\;lp/mm was 75%. And the excellent linearity was showed where the coefficient of determination ($r^2$) is 0.9693.

  • PDF

Bacteriological Research for the Contamination of Digital Portable Radiography (디지털 이동방사선검사에서의 세균 오염도)

  • Shin, Seong-gyu;Lee, Hyo-Yeong
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.7-12
    • /
    • 2017
  • The study was performed to investigate the bacteriological contamination of portable digital radiography system and their detectors in a university hospital. CNS and VRE were detected in the samples collected from vinyl cover on detectors used for the infection control patients. On the other hand, no bacteria was detected in the samples collected from detectors with vinyl cover removed. In the series of imaging of patients from general wards, no bacteria was detected from the patient 1. However, CNS was detected from the patients 2 and 3, CNS and Enterococcus faecalis detected from the patient 4, CNS and Enterococcus casseliflavus detected from the patient 5, and CNS, Enterococcus casseliflavus, and Klebsiella pneumoniae all detected from the patient 6. CNS and Enterococcus faecium were detected in the controller handle of collimator. Also, CNS was detected from the handle of detector and exposure switch. In the treatment gloves of the radiological technologist after the imaging, CNS, Enterococcus gallinarum, and Klebsiella pneumoniae were detected. Therefore, it is recommended for DR portable to take images after sterilizing the detector after taking each image and to use disposable vinyl covers on detectors to remove after imaging. And treatment gloves must be changed after each imaging. Also, hospital infection via portables must be prevented by complete sterilization of the controller handles of collimator which are in frequent contact during imaging and infection education of employees.

Implementation of A9-Based Digital Portable Radiation Detector with the Algorithm of Temperature Compensation in Scintillator (Scintillator에 온도 보정 알고리즘을 적용한 A9기반의 디지털 휴대용 방사선 검출기 구현)

  • Lim, Ik-Chan;Park, Geo;Kim, Young-kil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.10
    • /
    • pp.1981-1989
    • /
    • 2017
  • In accordance with the global strengthening of security systems for the safety of the shipping and logistics industry, the development of core technologies within the field has become a key in the establishment of Korea's own national logistics security system. Further in line with these global developments, there is growing attention within Korea to the development of portable radiation detectors capable of detecting gamma ray nuclides. In addition, many parts are becoming localized. In this research, instead of Pulse Shaping Board, which is used in existing portable radiation detectors, we have implemented an Algorithm to discriminate nuclides and correct the temperature conversion efficiency of the scintillator. This paper aims to improve the performance of these devices through the implementation of a temperature conversional algorithm within the scintillator of the A9-based digital portable radiation detector.

Comparison Study of the Modulation Transfer Function of a Prototype a-Se based Flat Panel Detector with Conventional Speed Class 400 Film/screen System (비정질 셀레늄을 이용한 직접방식의 디지털 방사선 검출기와 X-ray film과의 MTF측정을 통한 영상 질(quality) 비교평가에 관한 연구)

  • Park, Jang-Yong;Park, Ji-Koon;Kang, Sang-Sik;Moon, Chi-Woong;Lee, Hyung-Won;Nam, Sang-Hee
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.40 no.3
    • /
    • pp.163-171
    • /
    • 2003
  • To evaluate the performance of the digital radiography(DR) system developed in our group, the modulation transfer function(MTF) was measured and compared with that of an analog X- ray detector, film/screen system. The DR system has an amorphous selenium(a-Se) layer vacuum-evaporated on a TFT flat panel detector. The speed class 400 film/screen (Fuji) system has been being used in the clinical field as analog X-ray detectors. Both the square wave and slit method were used to evaluate their MTF. The square method was applied to both film/screen and the DR system. The slit method, however, was applied to only DR system. The full-width half maximum resolution of film/screen was 357${\mu}{\textrm}{m}$(1.4 lp/mm at 50% spatial frequency), and the resolution of DR was limited to 200${\mu}{\textrm}{m}$(2.5 lp/mm at 30%). These results indicate the measured resolution limitations approximate to the pixel pitch, 139 ${\mu}{\textrm}{m}$ of TFT. The MTF of DR is higher than that of film/screen by the factor of 1.785. It is proved that our a-Se based DR system has potential usefulness in the clinical field.

Image Quality Evaluation of Digital X-ray Image and Film Image using Contrast Method (Contrast Method를 이용한 디지털 X선 영상과 필름 영상의 영상 질(Quality) 평가)

  • Park, Ji-Koon;Jung, Bong-Jae;Choi, Jang-Yong;Kang, Sang-Sik
    • Journal of radiological science and technology
    • /
    • v.34 no.1
    • /
    • pp.9-15
    • /
    • 2011
  • In this paper, an image quality evaluation of amorphous selenium based x-ray system was performed using modulation transfer function (MTF) measurement. MTF as a main factor of imaging quality evaluation was investigated by contrast method from acquired test pattern image. The MTF value was measured to 36.1% at 3.0 lp/mm which is twice as high as that in the film image. Compared with other studies, the results demonstrate that amorphous selenium based x-ray detector is clinically meaningful.

Development of Dual Energy Radiation Detector (이중 에너지 방사선 검출기 개발)

  • Yeo, Hwa-Yeon
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.3
    • /
    • pp.5-11
    • /
    • 2010
  • In this paper, we are suggested development of dual-mode detector for dual-energy digital radiography. Design of dual-energy radiography module for commercial BIS (Baggage Inspection System) is used in the spectrum of the X-ray generator and detector for dual-mode features and radiological characteristics were analyzed. BIS suggestl on the image detector module being used to target X-ray tube to simulate X-ray spectrum and simulated spectrum to offer through the new radiographic characteristics of the detector modules were investigated. Using X-ray experiments with an increase in the thickness of the copper filter low energy detector (LED) and high-energy detector (HED) as the difference between the output signal increases. HED, especially in the size of the output signal decreases with increasing thickness of the copper filter was found.

Development of Radiation Image Sensor using Heterojunction (이종접합을 이용한 방사선 영상 센서 개발)

  • Kim, Young-Bin;Yun, Min-Seok;Kim, Min-Woo;Jung, Suk-Hee;Kim, Yoon-Suk;Oh, Kyung-Min;Nam, Sang-Hee;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.3
    • /
    • pp.27-35
    • /
    • 2009
  • In this study, the basic research verifying possibility of applications as radiology image sensor in Digital Radiography was performed, the radiology image sensor was fabricated using double layer technique tio decrease dark current. High efficiency material in substitution for a-Se have been studied as a direct method of imaging detector in Digital Radiography to decrease dark current by using Hetero junction already used as solar cell, semiconductor. Particle-In-Binder method is used to fabricate radiology image sensor because it has a lot of advantages such as fabrication convenient, high yield, suitability for large area sensor. But high leakage current is one of main problem in PIB method. To make up for the weak points, double layer technique is used, and it is considered that high efficient digital radiation sensor can be fabricated with easy and convenient process. In this study, electrical properties such as leakage current, sensitivity is measured to evaluate double layer radiation sensor material.

  • PDF

Digital Position Measurement with MLPE of PET detector using a Small Number of Photosensors (적은 수의 광센서를 사용한 PET 검출기의 최대우도함수를 적용한 디지털 위치 측정)

  • Kang, Seunghun;Lee, Seung-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.2
    • /
    • pp.151-156
    • /
    • 2022
  • A detector using a small number of photosensors was designed, and the position of a scintillation pixel that interacted with gamma rays through a maximum likelihood position estimation(MLPE) was measured as a digital position. For this purpose, simulation was performed using DETECT2000, which can simulate the movement of light within the scintillator, and the accuracy of position measurement was evaluated. A detector was configured using a 6 × 6 scintillation pixel array and 4 photosensors, and a gamma ray event was generated at the center of each scintillation pixel to create a look-up table through the ratio of acquired light. The gamma-ray event generated at the new position was applied as the input value of the MLPE, and the positiion of the scintillation pixel was converted into a digital positiion after comparison with the look-up table. All scintillation pixels were evaluated, and as a result, a high accuracy of 99.1% was obtained. When this method is applied to the currently usesd system, it is concidered that the process of determining the position of the scintillation pixel will be simplified.

Structural Design of Digital Radiography Detector using Hybrid Method for the Improvement of Response Property by X-ray (X-ray 반응 특성 개선을 위한 Hybrid형 디지털 방사선 검출기의 구조 설계)

  • Kim, Kyo-Tae;Han, Moo-Jae;Kim, Jin-Seon;Heo, Ye-Ji;Oh, Kyung-Min;Park, Ji-Koon;Nam, Sang-Hee
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.6
    • /
    • pp.363-367
    • /
    • 2015
  • Digital radiography is divided into the direct method using photoconductor and indirect method using phosphor based on the principles in acquiring the image information, but both have different advantages and disadvantages. Therefore, this study conducted a preliminary research on the structure of the hybrid detector that combined phosphor and photoconductor to improve the sensitivity of X-ray. As a result, when the tube voltage was adjusted at 30ms of exposure time, the direct structure displayed an overall excellent sensitivity, but at the exposure time of 50ms or more, the hybrid structure displayed a better outcome. This seems to have enough research value considering that various clinical examinations usually include 50ms or more exposure time.