• Title/Summary/Keyword: 디지탈 신호처리

Search Result 100, Processing Time 0.026 seconds

The Development of Digital FHR Monitoring System Using PC and DSP (PC와 디지탈 신호 처리기를 이용한 디지탈 FHR 감시 장치의 개발)

  • Chung, Ji-H.;Kim, Sun-I.;Park, Moon-I.;Lee, Doo-S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1991 no.11
    • /
    • pp.79-82
    • /
    • 1991
  • Digital FHR monitoring system based on the personal computer combined wi th the digital signal processing (DSP) board was implemented. The DSP board acquires and digitally processes ultrasound fetal Doppler signal for digital rectification, envelope detection, autocorrealtion function calculation and its peak position detection. The personal computer interfaced with the DSP board is in charge of graphic display, hardcopy, data taransmission and on-line analysis of fetal heart rate change including on-line warning system, base-line estmation, acceleration, deceleration and variability. The advantages of PC-DSP based system can be summarized as follows: 1) Minimum hardware realization. 2) Increased flexibility. 3) Total care system.

  • PDF

A Study on the Error Correction Algorithm for Digital Audio Systems (디지탈 오디오 시스템에서의 오류정정 알고리듬에 관한 연구)

  • Jun, Kyong-Il;Kim, Nam-Wook;Kim, Yong-Deak
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.7
    • /
    • pp.90-97
    • /
    • 1989
  • In this paper, we have taken the formation of two-dimension codeword named doubly-encoded code using the Reed-Solomon code, C1(32, 28) with minimum distance 5 and C2(32, 26) with minimum distance 7 and we have had computer simulation of these error correcting processes using modeled R-DAT (Rotationary Digital Audio Tape). As the result, the error rate per symbol has been decreased about 0.05 and on these processes, the newly developed digital signal processing technology such as erro correction using Berlekamp-Massey algorithm in frequency domain have been proven.

  • PDF

A Digital Audio Respose System Based on the RELP Algorithm (RELP 방식을 이용한 디지털 음성 응답기)

  • 김상용;은종관
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.21 no.6
    • /
    • pp.7-16
    • /
    • 1984
  • This paper describes the overall procedure of the development of a digital audio response system. It has been developed specifically as an answering system to the inquiries of telephone numbers from subscribers. The system has been realized based on the residual excited linear prediction (RELP) algorithm that incorporates a pitch predictive loop. Its major advantage over other similar systems is that it produces high quality of synthetic speech, although its memory size is relatively small. The hardware which consists of a speech synthesizer, a controller and an I/O part has been constructed using 2900 series bit-slice microprocessors and an INTEL 8085 microprocessor. The system is capable of real time processing, reliable, and adaptable to other applications.

  • PDF

A Study on the Algorithm and Design of Ambulatory Cardiac Output Monitoring System (휴대용 심박출량 모니터링 시스템의 설계와 알고리듬 연구)

  • Song, C.G.;Byun, Y.H.;Kim, K.S.;Kim, N.G.;Lee, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2702-2703
    • /
    • 2002
  • 본 연구에서는 종래의 심박출량 및 일회 심박동량 측정장치를 휴대용 시스템으로 구현하기 위한 회로 설계방법을 연구하였다. 휴대용 시스템의 설계를 위한 아날로그 부분은 인체 안전을 위한 아이솔레이션 증폭기, 변복조기, 0.1Hz 고역통과 필터 및 잡음제거 회로로 구성되며, 연속 심박출량 모니터링 및 연산을 위한 디지탈 부분은 TMS32030C를 이용한 회로로 구성이 된다. 또한 기존의 방법에서의 문제점을 개선하기 위해 연속 심박출량 연산을 위한 새로운 알고리듬을 제안하였다. 제안된 방법은 앙상블 평균시에 기존의 심전도 R피이크 점을 기준으로 하지 않고, 임피던스 신호의 dZ/dt 최대점을 이용하는 방법을 적용하였다. 제안한 심박출량 신호처리 알고리듬을 이용하여 측정된 임피던스 신호를 분석한 결과 최대 25.5 %까지 개선됨을 확인하였다.

  • PDF

A Study on the Interline Flicker Reduction of Teletext by using KProgressive Scan (점진적 주사방식에 의한 문자 방송에서의 라인 떨림 감소에 관한 연구)

  • Kim, Jae-Sun;Song, Chul
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.17 no.9
    • /
    • pp.982-992
    • /
    • 1992
  • We developed the interface system between D-SCAN TV system and the Teletext system to reduce the effect of interline flick. At first, horizontal and vertical signal is separated from the composite signal. The stable vertical sync and horizontal sync is applied to the conventional Teletext system and the its output has R.G.B signal form and the output of the Teletext system. This signal is converted into composite signal and is switched at the video selector system in TV to process the signal by progressive method.

  • PDF

Authentication and signature protocol using SM in IC-card system (SM을 사용한 IC 카드의 인증 및 서명 프로토콜)

  • 도신호;하재철;박영호;문상재
    • Proceedings of the Korea Institutes of Information Security and Cryptology Conference
    • /
    • 1996.11a
    • /
    • pp.374-382
    • /
    • 1996
  • 본 논문에서는 SM을 사용한 IC 카드의 인증 및 서명 프로토콜을 제안한다. SM은 연산 처리 능력이 우수하고, 안전한 보조 장치로 단말 내부에 장착된다. 제안된 프로토콜은 K nigs의 인증 방식, NIST의 ASACS, 그리고 UEPS와 비교하여 안전하고, 8비트 IC 카드에서 적합하게 개선하였다. 따라서 SM을 주민용 IC 카드의 단말에 장착하여 인증 및 디지탈 서명을 구현하는 방안을 제안한다.

  • PDF

A Styudy on the vibration reduction of flexible bcam by Piezoelectric Ceramic (피에조 세라믹을 이용한 유연한 보의 진동저감에 관한 연구)

  • 박수홍
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.04a
    • /
    • pp.351-355
    • /
    • 1996
  • 유연한 보의 진동문제에 대해 Filtered-X LMS 알고리즘을 이용하여 제어계를 구성하고 디지탈 신호처리보드를 이용하 여 실시간 제어를 수행하였다. 제어 엑추에이터로는 피에조 세라믹을 사용하였고 정현파 및 백색잡음 형태의 외력으 로 Shaker를 이용하여 보를 가진하였다. 백색잡음가진 실험결과 1차 고유진동수에서 14dB의 진동저감을 할 수 있었 으며 관심 주파수영역내에서진동이 고르게 저감되었다.

  • PDF

A Study on the Active Vibration Control of Flexible Beam Using Filtered-X LMS Algorithm (Filtered-X LMS 알고리즘을 이용한 유연한 보의 능동진동 제어)

  • 홍진석;손동구;박수홍;오재웅
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.402-407
    • /
    • 1994
  • 유연한 구조물의 진동문제에 대해 Filtered-X LMS 알고리즘을 이용한 제어계를 구성하고 디지탈 신호처리보드를 이용하여 실시간 제어를 수행하였다. 엑추에이터는 피에조 세라믹을 사용하였고 정현파 및 잡색잡음 가진 형태의 외란을 가하였다. 실험결과 1차 고유주파수에서 7dB 이상의 진동저감을 할 수 있었으며 관심 주파수영역 내에서 진동이 고르게 저감되었다.

  • PDF

A Study on Computer-Assisted Automatic Spike Detection System in EEG Signal of Epileptic Patients (콤퓨터를 이용한 간질환자 뇌파의 극파 자동검출 방법에 관한 연구)

  • Park, Gwang-Seok;Min, Byeong-Gu;Lee, Chung-Ung
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.17 no.6
    • /
    • pp.28-32
    • /
    • 1980
  • A digital system has been designed for the detection of abnormal spikes appearing in the epileptic patient's electroencephalogram(EEG). The detection is based on the waveform characteristics of spikes, such as the large slope, the sharpness of the apex, and the time duration of the spike. After the patient's data are collected and processed suing a minicomputer and A/D converter, the computer algorithms recognize the spikes based on the parameters representing the above waveform characteristics.

  • PDF

A Digital Signal Processing System for Analysis of Skeletal Muscle EMG Signal (골격근의 근전도 신호 분석을 위하 디지탈 신호처리 시스템의 설계)

  • 전철완
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.2
    • /
    • pp.155-164
    • /
    • 1996
  • In the clinical environment, measurements of some characteristics of the skeletal muscle are currently used to assess the severity of a neuromuscular disease or in some cases to assist in making a diagnosis. But a quantitative method of evaluation has not yet been introduced satisfactorily. In this paper, the skeletal EMG(biceps muscle, masseter muscle) analysis has been processed both in the time and in the frequency domain by designing the digital signal processing system based on pentium PC and transputer (IMS 7805). The experiment have been performed in five normal subjects, and various parameters have been statistically tested and compare4 As a results, the effective parameters obtained for the evaluation of skeletal EMG electrical activity are turn analysis, MiTi, MiTa, IEMG, PDF in the time domain, and are mean frequency, median frequency, skewness, kurtosis, muscle fatigue slope in the frequency domain. The designed H/W and S/W in this study can be used effectively for the establishment of EMG data base and for clinical research.

  • PDF